HomeMy WebLinkAboutREVISIONOFFICE USE ONLY: swwgu
DATE FILED:y =_ k��M V PERMIT # 1 9L 6 - 09 � b
REVISION FEE: �. 0 RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-56
(772) 462-1553 HIE
APPLICATION FOR BUILDING PERMIT REVISIONS
ISION
PROJECT INFORMATION
LOCATION/SITE
�14 y�1 korne� \ Aal< C\e pe-f sSd Woe, F(
i
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
a° —!•AI 5 -V Co .'
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: Q&— 0 ST. LUCIE CO CERT. #:
BUSINESS NAME: Sl \or-01A .>Z '
QUALIFIERS NAME: \ �a d u3.1-eg
ADDRESS: 1gi-13 Sw G\-er�al e -,-+ t
CITY: ?&rA S1 Wu-c.., STATE: 1=1 ZIP: IM167
PHONE (DAYTIME): `l-la aQw 9565 FAX:
OWNER/BUILDER INFORMATION:
NAME: _
ADDRESS:
CITY:
STATE:
PHONE (DAYTIME:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE:
PHONE (DAYTIME):
SLCCC: 9123109
Revised 06130/17
ZIP:
FAX:
ZIP:
FAX:
Rry ECLC. [11 . . . . .
MAY, 31,1, 2019
Permitting Department
St. Lucie County, FL
Business & Professional Regulation
rAMM
BCIS Home I Log In I user Registration I Hot Topics Submit Surcharge j stats & Facts i Publications Contact Us ! BCIS Site Map Links I Search
F eProduct Approval
IUSER: Public User
8`rPa�svd:p
Protlu[t Approval Menu > Product or ADolication Search > Application List > Application Detail
FL # FL18355-R4
Application Type Revision
Code Version REVIEWED FOR
Application Status Approved
Comments
CODE COMPLIANCE Archived ❑ ST■ LUCIE COUNW
Product Manufacturer TAMKO Building Products, Inc. BOCC
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri—eden@tamko.com
Authorized Signature Kerri Eden
kerri_eden@tamko.comFILE COP
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext2305
kerri—eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/18/2021
Validated By Locke Bowden P.E.
O Validation Checklist -Hardcopy Received
Certificate of Independence FL18355 R4 COI TBP15001'-4 2017 FBC Eval Report Shingles final pdf
Referenced Standard and Year (of Standard) Standard Year
ASTM D 3161 2016
ASTM D 3462 2010
ASTMD D 7158 2011
TAS 100 1995
Equivalence of Product Standards
Certified By Approved Testing Lab
FL18355 R4 Equiv UL letter for standards for FBC 2017 pdf
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
09/25/2017
Date Validated
09/27/2017
Date Pending FBC Approval
10/08/2017
Date Approved
12/12/2017
Summaryof Products
FL #
Model, Number or Name
Description
18355.1
Glass -Seal, Elite Glass -Seal,
ASTM D 3462 asphalt shingles and hip and ridge shingles
Heritage, Heritage Premium,
Heritage Woodgate, Heritage
Vintage, Hip and Ridge, and Vintage
Hip and Ridge Shingles
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FLIS355 R4 II TBP15001.4 2017 FBC Eval Report Shinoles
final.f
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL18355 R4 AE TBP15001.4 2017 FBC Eval Reoort Shingles
final. Ddf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(I),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
®� ® _
Credit Card
Safe
CREEK
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer: TAMKO BUILDING PRODUCTS
220 West 4`" Street
Joplin, MO 64801
(417) 624-6644
Manufacturing Plants: Joplin, MO
Phillipsburg, KS
Frederick, MD
Dallas, TX
Tuscaloosa, AL
Quality Assurance: UL LLC (QUA9625)
SCOPE
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813)480-3421
FLORIDA BUILDING CODE, 6TH EDITION (2017)
Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1
Properties: Physical properties, Wind Resistance, Wind Driven Rain
REFERENCES
Issued September 25, 2017
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
TAP-043-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-051-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-054-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-114-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-117-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-130-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-131-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-165-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-280-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-303-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-307-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-314-02-01 Rev 2
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-315-02-01
ASTM D 6381
2008(2013)e1
PRI Construction Materials Technologies (TST5878)
TAP-317-02-01
TAS 100
1995
UL LLC (TST9628)
02NK9507
ASTM D 3161
2016
UL LLC (TST9628)
04NK24366
ASTM D 3462
2010A
UL LLC (TST9628)
05NK28006
ASTM D 6381
2008(2013)e1
UL 2390
ASTM D 7158
2011
UL LLC (TST9628)
06NK03898
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
08CA59132
ASTM D 3161
2016
UL LLC (TST9628)
09NK07896
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
10CA50498
ASTM D 3462
2010A
UL LLC (TST9628)
1 OCA64882
ASTM D 3161
2016
UL LLC (TST9628)
11NK14014
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
12CA24551
ASTM D 3161
2016
UL LLC (TST9628)
4786110543
ASTM D 6381
2008(2013)e1
UL LLC (TST9628)
4787043752
ASTM D 3161
2016
UL LLC (TST9628)
4787148748
ASTM D 7158
2011
ASTM D 3161
2016
ASTM D 3462
2010A
CREEK Technical Services LLC (ANE11669)
TBP15001.3
Calculations
2017
TBP15001.4 FL18355-R4 Page 1 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes, throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Elite Glass -Seal®
12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick, Joplin &
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462.
Glass -Seal
12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick &
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462.
Glass -Seal
12-1/4" x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass
(Joplin
mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Heritage®
13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
Dallas, F Brick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Joplin, Phillipsburg &
complying with ASTM D 3462.
Tuscaloosa)
Heritage® Premium
13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg &
complying with ASTM D 3462.
Tuscaloosa)
Heritage® Premium
12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Frederick)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage® Vintage®
17-1/2" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Phillipsburg)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage® Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas & Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
Heritage® Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick & Joplin) shingle surfaced with mineral granules complying with ASTM D 3462.
Vintage® Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg) surfaced with mineral granules complying with ASTM D 3462.
TBP15001.4 FL18355-R4 Page 2-of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
INSTALLATION
Elite Glass -Seal®
(Frederick, Joplin &
Tuscaloosa)
Glass -Seal
(Frederick, Joplin (Non-
HVHZ) & Tuscaloosa)
Nailing
Area
Nailing
Area
Basic Wind Speed (Vu,t): Max. 194 mph
Basic Wind Speed (Vasa): Max. 150 mph
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Deck (HVHZ):
In accordance with FBC requirements;
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck (Non-HVHZ):
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
Underlayment:
In accordance with FBC requirements.
Min. slope:
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation (HVHZ):
Installed with 5-1/8 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ):
Installed with 5-1/8-inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
—in
Butt Edge
Figure 1. Elite Glass -Seal & Glass -Seal
4 Nail Pattern (Non-HVHZ only)
NAILS
Butt Edge
Figure 2. Elite Glass -Seal & Glass -Seal
6 Nail Pattern
-7ff
5-1 /8"
6-7/8"
5-1 /81,
TBP15001.4 FL18355-R4 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Heritage®
(Dallas, Frederick, Joplin,
Phillipsburg & Tuscaloosa)
Heritage® Premium
(Dallas, Frederick
Phillipsburg & Tuscaloosa)
Heritage® Woodgate
(Dallas & Frederick)
6-118"
Basic Wind Speed (Vwt):
Basic Wind Speed (Vasd):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5-5/8 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5-5/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
FASTENERS NAIL ZONE
COMMON
BOND
EXPOSURE 6-6/8"
1" �-- 12-112" 12-318" - 1 I -1"
Figure 3. Heritage®, Heritage® Premium, and Heritage® Woodgate (Dallas)
4 Nail Pattern (non-HVHZ only)
NAIL ZONE
1 " �-7-1/2'LH4- 7-1/2"-H4- 7-1 2"-1100-7-1/2"-►I �---1"
Figure 4. Heritage® & Heritage® Premium
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEKTAMKO BUILDING PRODUCTS
j� Asphalt Shingles
TECHNICAL SERVICES, LLC
NAIL ZONE!
NERS_ COMMON BOND
t
6-1l8° EXPOSURE 5 519"
VLA�7-1/2'+7-112'41*q-M+.112+7-1/2� �-V
Figure 5. Heritage® Woodgate
6 Nail Pattern
M Common Bond
1 + 39-3/8" 0 1 -
Figure 6. Heritage®, Heritage® Premium, & Heritage® Woodgate
Alternate 6 Nail Pattern
PAINT
LINE,
7-7I8" .T �-_- -- - -- — -- -- — -- - - - --- ---- - - -- - - -.. - - f -NAI L .ZO N E
6-1I8" EDGE OF
BOND
BOND
E7CPOSURE
ACCEPTABLE
FASTENER LOCATION
DO NOT FASTEN
ALONG' EDGE OF
COMMON"BOND
PREFERRED
FASTENER
LOCATION
Figure 7. Heritage® (Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above
TBP15001.4 FL18355-R4 Page 5 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Heritage@ Premium Basic Wind Speed (V„u):
(Frederick) Basic Wind Speed Wwd):
Deck (HVHZ):
5'12"1
1 "—►I
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12. .
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or T Nail Pattern" detailed below.
NAIL ZONE/
COMMON BOND
-- 12" --►� 11 —� k_1 "
Figure 8. HeritageO Premium (Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZONE/
FASTENERS COMMON BOND
5112" EXPOSURE 5"
1 n� �9112' 9"--+-3" 9112"
Figure 9. Heritage@ Premium (Frederick)
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 6 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Heritage® Woodgate Basic Wind Speed (V„it):
(Frederick) Basic Wind Speed (Vasd):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
ZONE/
AON BOND
ERS
IT
EXPOSURE 5"
i
1�- 11'- --►�---12-3/8"--- - 11" -� �-1"
Figure 10. Heritage® Woodgate (Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZON EJ
COMMON BOND
NERS
EXPOSURE 5"
1"� � 9-112"-�-3'�9�318"�3'+�1� 9-1/2" —►I �j"
Figure 11. Heritage® Woodgate (Frederick)
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 7 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Heritage® Vintage® Basic Wind Speed (V it):
(Phillipsburg) Basic Wind Speed (Vasd):
Deck (HVHZ):
Deck (Non-HVHZ)
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "5 Nail
Pattern" or "6 Nail Pattern" detailed below.
Figure 12. Heritage® Vintage®
5 Nail Pattern (non-HVHZ only)
TFSnetxes
161M'
Figure 13. Heritage® Vintage°
6 Nail Pattern
cposure
Notch
Expmu7!
Notdt
17-1/7'
TBP15001.4 FL18355-R4 Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Hip & Ridge Basic Wind Speed (Vut):
(Frederick & Joplin) Basic Wind Speed (Vasa):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5-1/8 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Directions of prevailing wind
5-1/8" exposure
Figure 1
,, 1 f 7
Fastener
r L5-5✓8"
Figure 2
a- 1/0 eapuuuru
Figure 14. Hip & Ridge (Frederick & Joplin)
TBP15001.4 FL18355-R4 Page 9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Vintage® Hip & Ridge Basic Wind Speed (Vu,t):
(Phillipsburg) Basic Wind Speed (Vasd):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5 inch exposure in accordance with the FBC
and manufacturer's published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
Start
here —
exposure
Figure 1
1� 1"
, Fastener
r �5-1/2"
Figure 2
o.. exposure
II-Igure u
Figure 15. Vintage® Hip & Ridge (Phillipsburg)
TBP15001.4 FL18355-R4 Page 10 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6t' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
R. p
• • RAF
`�.�P••.��C E N,9 •• ��,�i
No 74021
�:• STATE OF IQ
nn
CERTIFICATION OF INDEPENDENCE
2017.09.25
11:31:41
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE11669
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBP15001.4 FL18355-R4 Page 11 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.