Mobile Home Inspection Report StLuwiprflllnt'
All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this
completed Inspection Report and copies of both sides of the Title to the home.
All used Mobile homes must be Wind Zone II certified.
Owner: %ZYNS—C V& 60flP Date: _
(Print or type) I -
Address: 62 7 c� V
m
Year /Manufacturer 1991 P,hr�c�Jl,Ac�ioryo
Width i Length f 60 Single _
C = In Compliance N = Not in Compliance
P/&ACE
p 9io
s1i4P /!&
SPANISH LAKES
-F—L IRWAY5 M HP_
31�3�A FLf�J`!/�7?�7j 9
3.Z J5HUD Plate # FL� I �! ! 0
Double Wind Zone =
Fire Safety / Electrical
1. Smoke Detector: Installed V : Missing
2. Electrical System Checked: Exposed Wiring Other
G 3. Distribution Panel: Missing Loose Main Missing Breaker Missing
Unplugged Opening Other
C 4. Electrical Fixtures: Missing Installed Improperly
Improperly Wired Loose Wire
GFCI receptacles not where required
G5. Electrical Ground: Chassis Main Panel Gas Pipe
Revised 3/9/05
Page 1 of 3
File Copy
Construction
C 1. Exit Doors Operable: Front
Back
2. Exit Door Locks: Missing
Inoperable
C 3. Egress windows: Missing
Inoperable
4. Windows: Broken Glass
Inoperable
C 5. Screens: Missing Damaged
Other
_ 6. Floor System: Joist Decking Area Damaged
7. Interior Paneling: Missing Loose Damaged
C 8. Rodent Proofing: Bottom Board Pipe openings Other
9. Leaks Apparent: Ceiling Doors Floor Roof
C 10. Vertical tie -down straps: Missing Short Damaged
_C 11. Structural modifications since manufactured: YES_ NO_y'
C_ 12. Walls: Structurally Unsound Loose Weather tight
Plumbing
1. Trap: Missing Not connected Other
C 2. Plumbing fixtures: Missing Not installed Not Vented
C 3. Relief Valve: Missing Inoperable Other
G 4. Drain Waste and Venting Piping: Missing Not supported
Clean outs Use of fittings Not capped
C 1. Heating Appliances: Missin
Heating and Air Conditioning
Not Connected Other.
C 2. Deleted Heating/AC system: Not installed Other.
C 3. Thermostat: Missing Inoperable
C 4. Air registers: Missing Inoperable
C 5. Ducts: Not sealed Missing Collapsed
Page 2 of 3
File C®Py
C 6. Gas furnace Water heater vent: Missing
r7. Return Air: To Furnace To A/C
C 8. Range: Vent Hood
Loose
From rooms
9. Gas Valve: Accessible Installed improperly
10. Gas lines: Not capped Not supported Kinked
Notbonded
Summary
1. Is subject structure found to be fifty (50%) or more damaged or deteriorated?
2. Will a remodeling permit be required? YES NO
YES NO_J[_
The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent
than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be
limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232
IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO
BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY,
A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS
MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT.
NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE-
LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN
SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED.
A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX
THEIR SEAL.
Date inspected:
Inspected By: VWOOD I. ,
Phone Number: (Ii/�� )N5-73aj
License # 3 � 3 Jy
Page 3 of 3 Flle Copy
ft - - ___ _. I ..
YEng
STEVEN G. WOOD, P•E-
n LICENSE 34398
960S��rJ1 LUCIE, DR
pMmSCIE, FL