Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEi FORM R405-2017 I FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: GLOECKNER ADDITION Builder Name: Street: 32 GN WAY �`�'°` Permit Office: LUCIE COUNTY City, State, Zip: FTS PIERCE, FL, Permit Number:ST. Owner: DAVID GLOECKNER l3d� Jurisdiction: ST. LUCIE,COUNTY Design Location: FL, Fort Pierce St LOOP Parr"fa County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types (424.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Adjacent R=11.0 280.00 ft2 b. Concrete Block - Ext Insul, Exterior R=4.1 144.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 0(0) d. N/A R= ft2 10. Ceiling Types (304.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 304.00 ft 2 6. Conditioned floor area above grade (ft2) 304 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(15.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 60 a. U-Factor: Dbl, U=0.65 15.00 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 47.0 SEER:18.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 47.0 HSPF:9.80 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems -None required a. Cap: N/A 8. Floor Types (304.0 sqft.) Insulation Area • EF: 0.000 a. Slab -On -Grade Edge Insulation R=0.0 304.00 ft2 b. Conservation features b. N/A R= ft2 c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 8.86 Glass/Floor Area: 0.049 PASS Total Baseline Loads: 11.48 I I hereby certify that the plans and specifications covered by Review of the plans and Srq?� this calculation are in compliance with the Florida Energy specifications covered by this O�114E �y _ ; O �o Code. calculation indicates compliance vj �ii'� = s��,o�` with the Florida Energy Code. ti m„�•;' :;_ �;�,;;:•�"��;, O PREPA D BY: Before construction is completed DATE: this building will be inspected for I hereby that thisbuilding, de is in liance ecC s p0mr, atu s. certi as Y certify 9. with the Florida Energy Code. - com PilLaitu COD WE OWNER/AGENT: BUILDING OFFICIAL: DATE: Z Y _'XUWt- ` A DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/11/2018 1:26 PM EnergyGauge® USA Section R405.4.1ICompliant Software Page 1 of 4 I FORM R405-2017 INPUT SUMMAR I CHECKLIST REPORT I PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: GLOECKNER ADDITION Bedrooms` 0 User Conditioneld Area: 304 DAVID GLOECKNER Total Stories: 1 1 Worst Case: No Rotate Angle: 0 ST. LUCIE COUNTY Cross Ventilation: ST. LUCIE COUNTY Whole House Fan: Single-family Addition Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address 32 SOVEREIGN WAY St. Lucie FT. PIERCE, FL, CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI I 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 304 2432 I SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 ADDITION 304 2432 Yes II 1 1 Yes Yes Yes FLOORS I # Floor Type Space Perimeter I R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio ADDITION 75 ft I 0 304 ft2 ---- 1 0 0 ROOF I / V # Roof Gable Roof Type Materials Area Area Color Solar SA Emitt Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 329 ft2 0 ftl Light 0.6 No 0.9 No 20 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 i 304 ft2 N N i CEILING i # Ceiling Type Space R-Value; Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) ADDITION 20 1 Blown 304 ft2 0.11 Wood 6/11/2018 1:26 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 i FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT IWALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N 2 N Exterior Concrete Block - Ext Insu#DDITION 4.1 18 8 144.0 ft2 0 0 0.6 Garage Frame - Wood ADDITION 11 35 8 280.0 ft2 0.23 0.6 0 0 (WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes I Overhang NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Double Yes O�I65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1470 ft2 1470 ft2 I 40 ft 8 ft 11 INFILTRATION I # Scope Method SLA CFM 50I ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 283.7 I 15.58 29.29 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/Existing/c None I HSPF:9.8 47 kBtu/hr 1 sys#1 COOLING SYSTEM I # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Existing/confirme None I SEER: 18 47 kBtu/hr 1410 cfm 0.75 1 sys#1 SOLAR HOT WATER SYSTEM i FSEC Cert # Company Name I Collector Storage System Model # Collector Model # Area Volume FEF I ft2 DUCTS i # ---- Supply — Location R-Value Area ---- Return -- Air CFM 25 CFM25 HVAC # Location Area Type Handler TOT OUT QN RLF Heat Cool Leakage 1 Attic 6 60 ft2 Attic 15 ft2 Default Leakage Attic (Default) (Default) 1 1 6/11/2018 1:26 PM EnergyGauge® USA Section R4051I .1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES i Programable Thermostat: Y Ceiling Fans: Co In Jan Heating f X� Jan Feb Feb [ ] Mar [X] Mar [ [ ] Apr ]Apr [ [ ] Ma [X1 Jun ] Ma" ] Jun [X Jul [ Jul Au Au rl Se Sep rj [ ] Oct [ ]Oct 1 Nov Nov HX Dec Dec H Ventin [ Jan Feb X Mar [X] A r [ ] Ma ]]] Jun E [ ]]] Jul Aug Se [ Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78, 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 I MASS Mass Type Area I Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 ADDITION Name: Test Rater Rating Compant: Test Rater I Date: U —` 1—tz 6/11/2018 1:26 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 77 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. I 0 13. Cooling system: Capacity 47.0 a) Split system SEER 18.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 304 d) Room unit/PTAC EER e) Other 7. Windows, type and area I a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 47.0 c) Area 7c. 1510 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9.80 9. Floor type, insulation level: I a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. I 15. Water heating system c) Concrete, raised (R-value) 9c. I a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.11 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1061. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 20.0 b) Cross ventilation No b) Single assembly 11 b. I c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No I e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed de compliant features. Builder Signature: i Date: 2 1 Address of New Home: 32 SOVEREIGN WAY City/FL Zip: FT. PIERCE, FL I 6/11/2018 1:29:42 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 I * wrightsoft® Project Summaryl Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., Fr.. FL 34946 Phone: 772-466-6799 Fax 772-466-67 For. GLOECKNER R 32 SOVEREIGN Notes: Weather. Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 30487 Btuh Ducts 6623 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 37110 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 He a"Cooling Area (fF) 2624 2624 Volume (fi? 23616 23616 Airchanges/hour 0.32 0.16 Equiv AVF (cfm) 126 63 Heating Equipment Summary Make York Trade EXISTING EQUIPMENT Model YZHO4811 AHRI ref Email: FT. PIERCE, FL Pierce, FL, US Efficiency 9.8 HSPF Heating Input Heating output 48000 Btuh @ 47°I Temperature rise 28 OF Actual airflow 1567 cfm Airflowfactor 0.042 cfm/Btuh Static pressure 0.08 in H2O Space thermostat Capacity balance point = 35 OF Backup: Input =11 kW, Output = 37941 Btuh,100 AFUE Calculations approved byACCAto wrightsoft` PjghtSdte@Unversa1201818.0.16RSU08101 ...oamerls\WrigttsoftHVAC1GLOECKNERADDITION.rup Calc=MJ8 Front Do Job: Date: Apr 16, 2018 By: Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 gr/Ib Sensible Cooling Equipment Load Sizing Structure 33249 Btuh Ducts 4603 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturers data n Rate/swin multiplier 0.95 EquipmenI sensible load 35960 Btuh Latent Cooling Equipment Load Sizing Structure 3831 Btuh Ducts 3868 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 7699 Btuh Equipment Total Load (Sen+Lat) 43659 Btuh Req. total capacity at 0.70 SHR 4.3 ton Cooling Equipment Summary Make York Trade EXISTING EQUIPMENT Cond YZH04811 Coil AVY48D AHRI ref Efficiency Sensible cooling Latent cooling Total cooling Actual airflow Air flow factor Static pressure Load sensible heat ratio all N 12.3 EER,18 SEER 32900 Btuh 14100 Btuh 47000 Btuh 1567 cfrn 0.041 cfm/Btuh 0.08 in H2O 0.83 of Manual J 8th Ed. 2018-Jtr}11 13:2320 Page 1 -�- wrightsoft° Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS(, 40L.COM Job: Date: Apr 16, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Entire House 181.0 ft 9.0 It d 2624.0 ft2 EXISTING HOUSE 164.0 it 9.0 ft heaVcool 1.0 x 2344.0 It 2344.0 ft2 Ty Construction number U-value (BtuhAt-°F) Or HTM (Btuhlfl� Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 W - 13A4ois m 1A-clom 1A-clom IA-clom 1A-dom_-__- 13A-4ocs 1A-clom 11D0__-_`_-__ 13A4ocs _1A�lom 13A-4ocs 1A-clom IA-clom 1A-c'lorn 16X1Mad s_ 0:143 1.270 1.270 1.270 _-1.270 0.143 1.270 . 0.390 0.143 1.270 0.143 1.270 1.270 1.270 _0091 0.408 ne ne ne ne -ne_ se se _se_ sw - sw nw nw nw _nw _-__ __ _ -4A0 35.56 35.56 35.56 -_35.56 4.00 35.56 _ 10.92 4.00 _,-35.56 4.00 35.56 35.56 35.56 __2.55 1.59 _-- 2.55 70.43 70.43 70.43 ._,_70.43 2.55 70.95 _ 1131. 2.55 _ 0.95 2.55 70A3 70.43 _ 7Q43 . 128 :- 486 9 15 18 -1R 495 75 _ 21 153 , 15. 495 12 15 90 _ A 909 _ _ 2624 ,_ 425 0 0 0 _ 0_ 399 0 _ _21_ 138 _____.__ 0 378 0 0 _ _0_ __-_909 _ 2624 181 ____-1701 320 533 640 685 1598 2667 _ __-_229 553 __._.__533. 1515 415 533 _ 3200 ____2316 ____ _4160 _ _,_ b012 1081 634 1056 1268 1357 1016 5321 .__, ___238 ' 351 _ VI54 963 822 1056 6339 _ ___j166 3899 _ -.-_ 0 - -__ 486 9 15 18 _ 19 495 75 _____21 0 --.-0. 495 12 15 90 --1081 634 1056 1268 - 135.7 1016 5321 ,_-_238 0 _0 963 822 1056 _ 6339 3483 ---4-25 0 0 0 _-0 399 0 ___ 21 0 -------o 378 0 0 - _0. _--_-522 2344 ---164-0- 1701 320 533 640 685 1598 2667 __ _229 0 1515 415 533 3200 3716 - ___ W L-G. WI - {---c� (L-G� C^_ _ ---522 Y- 2344, .2344 _1,49 6 c) AED excursion I 0 -343 Envelope loss(gain I 26611 27631 23625 24960 12 a) Infiltration b) Room ventilation 3876 0 1038 01 3512 0 941 0 13 Internal gains: Ooc upants @ 230 Applianceslother I 6 ` 1380 3200 4 920 2000 Subtotal (lines 6 to 13) I 30487 33249 27137 28821 14 15 Less exlemalload Lesstransfer Redistribution Subtotal Duct loads I I 22% 14% 0 0 0 30487 6623 0 0 0 33249 4603 22% 14% 0 0 0 27137 5895 0 0 0 28821 3990 Total room load Air required (dm) I 37110 1567 37853 1567 33032 1395 32811 1358 ACCAto -0 AMAr-- =!Mt!tsoft" I 2018-Ju r11 13:23:20 �^ - Right SuteOUniversal 201818.0.16 RSU08101 Page 1 oarnerts\WrigttsoftHVAC1GLOECKNERADDITION.rup Calc=MJ8 FrortDoorfaces: N I Job: -�- wrightsoft Right-M Worksheet Entire House I Date: Apr 16, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area NEW SEWING 10.0 it 9.0 ft heat/cool 15.0 x 10.0 It 150.0 ft2 NEW BATH 0 ft 9.0 It heaU000l 10.0 x 6.0 ft 60.0 f6 Ty Construclion number U-value (Btuh/ft;°F-) Or HTM (Btuhlit2) Area or perimeter (ft) Load (Btuh) Area (ftr or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 -- -- 13A-4as - -- - 1A-Llom 1A--lom 1Aclom IA-dom--_-_- 13AAocs IA-c1om 11DO 13A-4ocs _ - - 13A-40cs 1A-;1om IA-:1om 1A_clom__ 12GOsrv_----,,-- 16X19-Oad -- 0.143 1.270 1.270 1.270 _- 1.270 0.143 1.270 0.390 0.143 1.270 0.143 1.270 1.270 1270_nw. _-_ - 0A91 0.408 0.989 ne ne ne ne -ne se se se 8e -sv✓ nw nw nw -_- - - - - - 4.00 35.56 35.56 35.56 35.56 4.00 35.56 _ 10.92 4.00 ,35.56 4.00 35.56 35.56 ---35.56 -- _-2.55 1.59 - - 27.69 - 2.55 70.43 70.43 7OA3 _70.43 2.55 70.95 11.31 2.55 --70.95. 2.55 70A3 70.43 -.70.43 -__.1.28 1.49 - _- 0.00 - ---- 0 0 0 0 -_--_Q 0 0 0 90 - ----- --15 0 0 0 -0- - ---_- 90 150 .- - ---150 --- -0 0 0 0 _-- -0 0 0 0 75 - ---0 0 0 0 -- --_0-.--- 90- 150 - - ----1 - --- 0 0 0 0 -----0 0 0 0 300 -- - 533 0 0 0 0 ---- _-229 238 - - 2n -- - - 0 0 0 0 .-_ 0 0 0 0 191 --. 1064 0 0 0 --- 0-_-_-__ _--- 115 223 -- --0 - - - 0 0 0 0 _- -_ 0 0 0 0 0 -- - -.0 0 0 0 0 .---144 60 -- - -60 - --- -0 0 0 0 __-_- 0 0 0 0 0 --- 0 0 0 0 _ _-0_--------� ----J44 60 - - -0 - --0 0 0 0 -- -----0 0 0 0 0 - ---0- 0 0 0 _-- -_367 95 -- - -0 - - p 0 0 0 -----0, 0 0 0 0 --- -0 0 0 0 ------0 89 -- �N �--G W - W P--- C 6 c) AED excursion I 352 -3 Emelope loss(gain I 1578 1945 462 271 12 a) Infiltration b) Room %entilation I 214 0 57 0 0 0 0 0 13 Internal gains; Oo:upants@ 230 Appliances/other 2 I 460 1200 0 0 0 Subtotal (lines 6to 13) I 1792 3663 462 271 14 15 Less extemalload Less transfer Redistribution Subtotal Ductloads I 2`2% 14% 0 0 0 1792 389 0 0 0 3663 507 22% 14% 0 0 0 462 100 0 0 0 271 37 Total room load Air required (dm) I 2181 92 4170 1731 562 24 308 13 all C wrigF�tsoTt` Right-SUte®Urrversa12018 18.0.16 RSU08101 '��p`...oarnerts\WrigttsoftWAC\GLOECKNERADDITION.rup Calc=MJ8 FrortDo 2018-Jun-11 13:2320 Page 2 wrightsoft° Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone: 772-466-6799 Fax. 772. 6796 Email: QUICKCALCS@,AOL.COM Job: Date: Apr 16, 2018 By: 1 2 3 4 5 Room name I Exposed wall Room height Room dimensions Room area NEWSTUDIO 7.0 ft 9.0 ft heaftol 10.0 x 7.0 ft 70.0 fP Ty Construction number U-value (Bhrh/R{°F) Or HTM (BtuhAt� Area (M or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A�ocs - 1Aclom 1Aclom 1Aclom 1A 1om:_.- _ 13A-4ocs 1Aclom _11DO 13A-flocs:--'� - A- _c1om_._-.- 13A-4ocs 1A-clom IA-clom IA-clom -lfc 16x19.Oad 22A7tpl 0.143 1.270 1.270 1270 __- 1.27.0 0.143 1270 0.390 0.143 _- 1.270 0.143 1.270 1.270 1270 _- 0091, 0.408 0.989 ne ne ne ne -ne- se se se- sw_ -sw- nw nw nw nw __ _ - _ - 4.00 35.56 35.56 35.66 -- 35.56 4.00 35.56 10.9211.31 4.00 --35.56 4.00 35.56 35.56 -_35.56 _ 2.55 1.59 -27.69 - 2.55 70.43 70.43 70.43 .-_70.40L 2.55 70.95 2.55 -w70.95 2.55 70.43 70.43 70.43 ____ 1.28 1.49 - -0.00 0 0 0 0 0. 0 0 0 63 _ ._�_-0. 0 0 0 _ - 0 _-_153 70 _ 70. ---0- 0 0 0 -0_ 0 0 0 -` 0 0 0 0 ----0 0 0 0 -- --0 0 0 0 -_-.-0 0 0 ---- _ W f--C _ --_____0 0 0 0 0 --_---9 0 0 0 0 W -------0 0. 0 0 0 - _-_ �_ P__ C .F_ 153; 70 7 __-.- _`_ 390 111 _ 194. _ _ _ _ 196 104 0 __ 6 c) AED excursion I -6 Envelope losstgain I 947 455 12 a) Infiltration b) Room ventilation I 150 0 40 0 13 Internal gain. Oo upants@ 230 Applianosslother 0 0 0 Subtofal(lines 6to13) I 1097 495 14 15 Less extemalload Less transfer Redistribution Subblal Dud loads 22% 14% 0 0 0 1097 238 0 0 0 495 69 Total room load Air required (dm) I 1335 56 W3 231 1 T melt all reauirements of -rid- wrfigF�tsoTtd A& Right-SUteO Universal 2018 18.0.16 RS U08101 me oartsAWrigWoftHVAC\GLOECKNERADDITION.rup Calc=MJ8 FrortDo 2018-JuF11 13:23:20 Page 3 - wrightsoft® Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: For: GLOECKNER RESIDE 32 SOVEREIGN WAY External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Email: QUICKCALCS@,AOL.COM PIERCE, FL Heating 0.08 in H2O 0 in H2O 0.08 in H2O /0.040 in H2O 0.077 in/100ft 1567 cfm 104 ft Job: Date: Apr 16, 2018 By: Cooling 0.08 in H2O 0 in H2O 0.08 in H2O 0.040 / 0.040 in H2O 0.077 i n/100ft 1567 cfm Design Design Htg Clg Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mat Ln (ft) Ln (ft) Trunk EXISTING HOUSE-G h 32811 1395 1358 0 0 Ox 0 VIFx 0 0 NEW BATH h 562 24 13 0.077 4.0 Ox 0 VIFx 14.0 90.0 NEW SEWING -A c 4170 92 173 0.122 8.0 Ox 0 VIFx 10.8 55.0 NEW STUDIO h 1335 56 23 0.102 6.0 Ox 0 VIFx 8.5 70.0 Grille Htg Clg TEL Design Meloc Diam H x W Stud/Joist Duct Name Size (in) (cfrn) (cfm) (ft) FRI (fpm) (in) (in) Opening (in) Mat Trunk rb1 Ox 0 1567 1567 0 0 0 0 Ox 0 VIFx - - wrightsoft® ��,.�•��..��,R��..,��,,.� Right-Sute®Ur9versa1201818.0.16F ...oamertMWrightsoftHVAC\GLOECKNERADDITION.np Calc=MJ8 Door faces: N 2018-Jrrr11 13:23:20 Page 1