Loading...
HomeMy WebLinkAboutLETTER PLAN EXAMINER REVIEWJUL 10 2018 06/29/18 City of Port St. Lucie Building Department Plan Review Div. A R C H I T E C T S Design Groupl�c. RE: Oakland Lake (Lot 66) 1452 Model, Permit #1806-0414 [PLANS EXAMINER REVIEW] PAGE 4 OF EIGHT OF THE SUBMITTEI�DRAWINGS NOTE NUMBERONE, SPECIFIES PRIOR TO DRYWALL INSULATION ON ALL FRAMING MEMBERS 2' FOOT FROM THE FINISH FLOOR WILL BE SPRAYED AND TREATED WITH BORATE TERMITE TREATED SPRAYED.;THE REST OF THE PLANS SPECIFY CLEAN COMPACTED .TERMITE TREATED FILL. PLEASE CORRECT DRAWINGS TO SHOW ACTUAL CONDITIONS'TO BE INSTALLED. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. See revised sheet 4 PLANS SHOW LAP SIDING AND STUCCO DETAILS. PLEASE REMOVE FROM THE PLANS ANY INFORMATION NOT PERTAINING TO THE NEW STRUCTURE. SEE SECTION 107.2.4 OF THE 2017 FLORIDA BUILDING CODE. See revised sheet WA1 & WA4 PLANS SHOW A BALCONY DETAIL NO BALCONY IS SHOWN ON THE ELEVATION PAGES OR THE FLOOR PLAN. PLEASE REMOVE FROM THE PLANS ANY INFORMATION NOT PERTAINING TO THE NEW STRUCTURE. SEE SECTION 107.2.4 OF THE 2017 FLORIDA BUILDING CODE. See revised sheet WA3 THE TOTAL MODIFIED LOAD.ON THE ENERGY CAL MUST BE LOWER OR EQUAL.TO THE TOTAL BASE LINE LOADS. SEE SECTION R405.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION FIFTH: EDITION. tey�sed 2.vr+pavcadGS PRODUCT APPROVAL/NOA NUMBER 14039 — R-2 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. See revised sheet 8 1 PRODUCT APPROVAL/NOA NUMBER 140M —. R-2 IS THE.REVISION NUMBER FOR THE PRODUCT. PLEASE AORRECT PRODUCT APPROVAL NUMBER ON (PLANS TO REFLECTTHE SITE SPECIFIC PRODUCT APPROVAL UMBER. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. See revised sheet 8 1441 N. Ronald Reagan Blvd. • Longwood, FL 32750 • Phone: (407) 774-6018 • Fax: (407) 774-4078 i 'AA0003325 www.abdesiiznvrouD.com ARCHITECTS eDesign ouphc. fj. PRODUCT APPROVAL/NOA NUMBER 5891— R-5 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. See revised sheet 8 PRODUCT APPROVAL/NOA NUMBER 5891— R-5 IS THE REVISION NUMBER FOR THE PRODUCT. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS TO REFLECT THE SITE SPECIFIC PRODUCT APPROVAL NUMBER. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE See revised sheet 8 PRODUCT APPROVAL/NOA NUMBER 5219.3 — R-3 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF.THE 2017 FLORIDA BUILDING CODE. See revised sheet 8 PRODUCT APPROVAL/NOA NUMBER 15216 — R-2 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. See revised sheet'8 PRODUCT APPROVAL/NOA NUMBER 15216 — R-2 IS THE REVISION NUMBER FOR THE. PRODUCT. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS TO REFLECT THE SITE SPECIFIC PRODUCT APPROVAL NUMBER. SEE.CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING_ CODE See revised sheet 8 PRODUCT APPROVAL/NOA NUMBER 18355 — R-3 IS OUTDATED.. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. See revised sheet 8 PRODUCT APPROVAL/NOA NUMBER 18355 _ R-3 IS THE REVISION NUMBER FOR -THE PRODUCT. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS TO REFLECT THE SITE SPECIFIC PRODUCT APPROVAL NUMBER. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE See revised sheet 8 PRODUCT REVIEW AFFIDAVIT IS INCOMPLETE ON PAGE 8 OF 8. MULTIPLE N/A'S IN SECTIONS OF THE REVIEW AFFIDAVIT THAT NEEDS TO BE COMPLETED FOR REVIEW. SEE SECTION 107 OF THE:2017 FLORIDA BUILDING CODE. %=ep,-% Y('v%wA -Ito vvuAr- + a '�dO�.V�•�' " 1441 N. Ronald Reagan Blvd. • Longwood, FL 32750 • Phone: (407) 7.74-6018 • Fax: (407) 774-4078 % AA0003325 www.andeciunpmnn rnm .~ ` eDespirn ° PLEASE FURNISH DESIGN CRITERIA INCLUDING BUT NOT LIMITED TOVNNDVVOAD,.DESIGN PRE3SURES, EXPOSURE CATEGORY, RISK CATEGORY AND DESIGN CODES IN ACCORDANCE WITH SECTION O1OFTHE ^ FLORIDA RESIDENTIAL CODE. � See Information provided onsheet [36&GN Should you have any questions regarding this letter, do not hesitate to call me. jV FIbr d lijk rhi937-23