PROJECT INFORMATION 5-27--
t� SCAMW Total Life Safety Corporation 1045 NE ndustrial Boulevard Jensen B ach, Florida 34957 (772) 600.4650 Job Name Sedona - 6 Unit I Building 1-Story Multiplex Location Port St. Lucie, R System 1-Living Area Contract Data File Sedona.wxf ~� U V� 1 O R 2 ? OECD n kA Computer by Hydratec Inc. Revision: 50.51.1 Total Life Safety Corporation Page. 1 - Sedona - 6 Unit Multiplex Date 12/11/2017 HYDRAULIC DESIGN INFORMATION SHEET Name - Sedona - 6 unit Multiplex Date.'- 1.2/11/2017 Location - Port St. Lucie, Florida Building - 1-Story Multiplex System No. - 1-Living Area Contractor - Total Life Safety Corporation Contract No. - Calculated By - A. Gonzalez Drawing No. - FP-1 Construction: (X) Combustible ( ) Non -Combustible Ceiling Height Varies OCCUPANCY - Residential S Type of Calculation: ( )NFPA 13 Residential (X)NFPA 13R ( )NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16' x 16' ( ) Deluge ( ) PreAction E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - 0 Gpm Make Victaulic Model V2732 I Elevation at Highest Outlet - 10'-4"Feet Size 1/2" K-Factor 4.9 G Note: Temperature Rating 155 N Calculation Gpm Required 26.317 Psi Required 23.482 Base of Riser Summary C-Factor Used: Overhead 150 Underground N/A W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 11/14/2017 Rated Cap. Cap. T Time of Test - 9:25 a.m. @ Psi Elev. E Static (Psi) - 71 psi Elev. R Residual (Psi) - 65 psi Other Well Flow (Gpm) - 1,250 gpm Proof Flow Gpm S Elevation - P Location: Edwards Road & S. 25th Street P L Source of Information: Fort Pierce Utilities Authority Y Computer Programs by Hydratec Inc. Revision: 50.51.1 WaterSupply'Curve.0 Total Life Safety Corporation Page 2 Sedona - 6 Unit Multiplex, i Date 12/11/2017 30 28 26 p 24 R 22 E 20 S 18 S 16 U 14 R12 E 10 8 6 4 2 D1 10 20 30 40 50 60 FLOW (NA1.85) 70 80 Demand: D1 - Elevation 3.609 D2 - System Flow : 26.4 D2 - System Pressure 18.824 Hose ( Demand ) D3 - System Demand : 26.4 Safety Margin ;M4 Computer Programs by Hydratec Inc. Revision: 50.51.1 Fittings Used Summary Total Life Safety Corporation Page 3 Sedona - 6 Unit Multiplex Date 12/11/2017 Fitting Legend Abbrev. Name '/ % 1 1% 1% 2 2% 3 3%z 4 5 6 8 10 12 14 16 18 20 24 Ball B Ball Milw BB-SC1o0 2.25 2 2.5 2.25 10 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. it Computer Programs by Hydratec Inc. Revision: 50.51.1 a:, ' Pressure /. Flow Summary - STANDARD Total Life,Safety Corporation Sedona - 6 Unit Multiplex Page Date 4 12/11/2017 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actua Actual Reg. 1 9.333 4.9 7.0 na 12.96 0.05 256 7.0 .2 9.333 4.9 7.512 na 13.44 0.05 256 7.0 1A 10.333 7.21 na 2A 10.333 7.72 na 100 10.333 11.25 na TOR 10.333 11.46 na BOR 1.0 18.82 na The maximum velocity is 8.9 and it occurs in the pipe nodes 2A and 100 Computer Programs by Hydratec Inc. Revision: 50.51.1 Final Calculations - Hazen -Williams Total Life Safety Corporation Page. 5 Sedona - 6 Unit Multiplex Date 12/11/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. licit or Ftng's Pe Pv ****"** Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn . *P-1 1 12.96 1.101 2E 7.65 3.500 7.000 K Factor = 4.90 ' to 150.0 T 9.563 17.212 -0.433 1A 12.96 0.0305 0.0 20.712 0.632 Vel = 4.37 0.0 ' 12.96 7.199 K Factor = 4.83 *P-2 2 13.44 1.101 2E 7.65 2.333 7.518 K Factor = 4.90 to 150.0 T 9.563 17.212 -0.433 2A 13.44 0.0326 0.0 19.545 0.637 Vel = 4.53 0.0 13.44 7.722 K Factor = 4.84 *P-3 1A 12.96 1.101 2E 7.65 9.500 7.199 to 150.0 0.0 7.650 0.0 2A 12.96 0.0305 0.0 17.150 0.523 Vel = 4.37 2A 13.44 1.101 2E 7.65 13.833 7.722 to 150.0 T 9.563 17.212 0.0 100 26.4 0.1137 0.0 31.045 3.530 Vel = 8.90 0.0 26.40 11.252 K Factor = 7.87 *P-4 100 26.40 1.598 E 5.828 5.500 11.252 to 150.0 0.0 5.828 0.0 TOR 26.4 0.0185 0.0 11.328 0.210 Vel = 4.22 TOR 0.0 1.61 Fsp 0.0 9.330 11.462 to 120.0 Ball 2.5 2.500 7.042 * * Fixed Loss = 3 BOR 26.4 0.0270 0.0 11.830 0.320 Vel = 4.16 0.0 26.40 18.824 K Factor = 6.08 Computer Programs by Hydratec Inc. Revision: 50.51.1 V279 K4o9 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Residential Pendent, Recessed Pendent and Specific Application (Flat, Sloped & Beamed Ceilings) V2730 QUICK RESPONSE V2732 QUICK RESPONSE; These Model V27 residential sprinklers are designed to meet the equirements of NFPA 13, 13D k�,w and 13R for residential use in a variety of room sizes, depending upon available operating pres- sure and room configuration. Models V2730 and V2732 are UL Li ted for use under smooth flat F - horizontal ceilings, sloped ceilings up to and Including 8/12 (33.71) pitch, and beamed ceilings. y The design incorporates stateof- the -art, heat responsive; frangibl glass bulb design (quick ' response) for prompt, precise operation. The die cast frame is more streamlined and attractive than tradillorial sand cast frames. It is cast With a hex -shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various finishes to meet many design requirements. PENDENT RECESSED (V2730) PENDENT (V2732) SPRINKLER OPERATION: The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambien temperature rises causing the liquid in the bulb to expand. When the ambient tem- perature reache the rated temperature of the sprinkler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. COVERAGE: Residential sprat coverage up to 400sq.ft./37.2sq.m room sizes per NFPA 13. . These sprinkler meet the.requirements of UL 1626 that became effective September 25, 2004. TECHNICAL SPECIFICATIONS: Models: V2730, 2732 Accessories Style: Pendent nd Recessed Installation Wrench: Pendent Open End: V27 Nominal Orifice Size: 7/,6%12mm 0 Recessed: V27-2 r K-Factor: Sprinkler Finishes: • V273 —4.9 Imp./7.1 S.I A for a Plain brass room sizes p to 16/4.9 m. 0 Chrome plated �E� I • V273 —4.9 Imp./7.1 S.I A for • White painted`* J room sizes 1810 2075.5 and 6.1 m. • Custom painted" Nominal Thread Size:1h NPT/15 mm For escutcheons, cabinets and other accessories Max. Working Pressure: 175 psi/1200kPa refer to separate sheet. Factory Hydrostatic Test: A For K-Factor when pressure is measured in 100% ®500psi/3450kPa Bar, multiply S.I. units by 10.0. Min. Operating Oressure: 7psi/48kPa Teflon is a registered trademark of Dupont Co. Temperature Rating: See chart on page 2 *• UL Listed for corrosion resistance. `\ NOTE: Weather resistant recessed escutcheons Material Specifi cations available upon request. v273z Pendent Deflector: Bronze per UNS C51000 or Bulb: Glass with klycerin solution. V2730 Bulb Nominal Diameter: Quick ~ esponse: 3.0mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze Per UNS C65100 Exaggerated for Clarity Seal: Teflon' tape Frame: Die cast brass 65-30 JOB/OWNER CONTRACTORI ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com ictauliC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_D I 40.41_1 FIRE PROTECTION PRODUCTS — AUTOMATIC SPRINKLERS V27, K4.9 Residential Pendent, Recessed Pendent and Specific Application (Flat, Sloped & Beamed Ceilings) V2730 QUICK RESPONSE V2732 QUICK RESPONSE APPROVALS/LISTINGS * Listings and approval as of printing. A For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. t MEA N62-99-E. § CSFM #7690-0531:112 5. 40.41 RATINGS All glass bulbs are rated for temperatures from—67°F/-55°C to those shown in table below. Ordinary C i 68 38 Red Intermediate E I 79 66 Yellow VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. �Ctaulicr 40.412 REV_D FIRE PROTECTION PRODUCTS — AUTOMATIC SPRINKLERS 40.41 V271 I04.9 Residential Pendent, Recessed Pendent and Specific Application (Flat, Sloped & Beamed Ceilings) V2730 QUICK RESPONSE V2732 QUICK RESPONSE ORDERING INFORMATION Please specify I the following when ordering: Number Sprinkler Model Style Temperature Raafting K-Factor Thread Size Quantity Sprinkler Finish Escutcheon Fin'sh Number Wrench Model www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. m 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. Aulidta REV_D 40.413 FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS V27y K4o9 Residential Pendent, Recessed Pendent and Specific Application (Flat, Sloped & Beamed Ceilings) V2730 QUICK RESPONSE V2732 QUICK RESPONSE A WARNING 40.41 M 3 • Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. • Installation rules, especially those governing obstruction, must be strictly followed. • Painting, plating, or any re -coating of sprinklers (other than that sup- plied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler _ systems. In addition, the authority having jurisdiction may have addi- tional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. AVAILABLE WRENCHES Sprinkler Type .. V2730, V2732 — Pendent I V27 i V27-2 V2730, V2732 — RecessedPendent i — V27-2 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. �CtalJh 40.41_4 REV D FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 40.41 V271 K4.9 Residential Pendent, Recessed Pendent and Specific Application (Flat, Sloped & Beamed Ceilings) V2730 QUICK RESPONSE V2732 QUICK RESPONSE DIMENSIONS 2>✓e 1 (61 mm) 15/e 1 (42 mm) - ►I15%z' (29 mm) Standard Pendent-V2730 IW Adjustment Recessed - V2730 (drawing not to scale) 2%'/60 mm Max. Hole 2%51 mm Min. Hole 116% W1 1 44 mm 2W (61 mm) 1s%• 1 (42 mm) 15A2 (29 mm) �— Standard Pendent-V2732 W Adjustment Recessed - V2732 (drawing not to scale) 23a' (60 mm) Max. Hole �)II 2' (51 mm) Min. Hole 'Ve 7A ailingTile (lgmm) F Surface 11916 (44 mr 21sAe _ i:) mm (75 mm) MAXIMUM EXTENSION II MAXIMUM EXTENSION 1 1 1xe 30mm Mat" Typica`Ceiling Tile (27mm) Mat" �— �— IMe/ _T 131re 30 mm t (30 mm) Finished Surface MAXIMUM RECESS MAXIMUM RECESS Typical Ceiling Tile — Finished Surface Typical Tile — Finished Surface www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2012 VIC AULIC COMPANY. ALL RIGHTS RESERVED. �Ci.�oiUll Cr REV_D 40.41_5 FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS V277 K4.9 Residential Pendent, Recessed Pendent and Specific Application (Flat, Sloped & Beamed Ceilings) V2730 QUICK RESPONSE V2732 QUICK RESPONSE ; 1 40.41 DIMENSIONS AND ROOM SIZE Victaulic V2730 and V2732 K4.9A Sprinkler - Residential Pendent and Recessed Pendent r4 I V2730 12 X 12 ' 12 I 13 7.0 13 ! 7.0 1 'A to 4 Inch or 8.0 3.7 X 3.7 3.7 49.2- I 48.5 i 49.2 48.5 '/+ recessed 2.4 V2730 14X14 14 13 I 7.0 i 15 9.4 1'Ato4Inch or 8.0 I 4.3 X 4.3 , 4.3 , 49.2 48.5 ! 56.6 64.5 ' /+recessed 2.4 } -' ' V2730 16X 16 16 13 7.0 !- 15 9.4 1Meto4Inch or 8.0 I 4.9 X 4.9 ; 4.9 49.2 48.5 i 56.8 ; 65.0 1/+ recessed 2A Horizontal V2732 12 X 12 ! 12 13 ! 7.0 13 J ZO 1 % to 4 Inch or '8.0 and Beamed 3.7 X 3.7 3.7 49.2 ! 48.5 49.2 48.5 '/+recessed 2.4 Ceilings Up to .. ..-__ .-.-__.._ _.:_..._...._.. ;- - _.. .__ -.. 2/12(9.5°) i V2732 14X14 14 17 12.0 � 17 1 12.0 I 1'Ato4inch or 8.0 Pitch i 4.3 X 4.3 ! 4.3 i 64.3 j 83.0 1 64.3 1 83.0 i 1/+ recessed 2A V2732 16X 16 4 16 17 12.0 17 12.0 i 1 '/a to 4 Inch or 8.0 4.9 X 4.9 4.9 64.3 83.0 64.3 83.0 I '/+ recessed 2A V2732 18 X 18 18 I 17 12.0 17 ! 12.0 1 'A to 4 Inch or 8.0 5.5 X 5.5 ! 5.5 64.3 ! 83.0 64.3 i 83.0 1/ recessed 2.4 V2732 20 X 20 20 20 16.7 1 20 ! 16.7 1 '/a to 4 Inch or 8.0 6.1 X 6.1 ! 12 X 12 6.1 12 ! 75.7 ! i.. 13 114.9 7.0 75.7 15 114.9 I 9.4 3/+ recessed 1 % to 41nch or 2.4 8.0 _ V2730 3.7 X 3.7 I 3.7 49.2 j 48.5 j 56.8 65.0 '/+ recessed 2.4 V2730 14 X 14 4.3 X 4.3 , 14 4.3 13 49.2 .` 7.0 48.5 15 56.8 I 9.4 65.0 ! 1'/a to 4 Inch or '/+ recessed 8.0 2.4 V2730 16X 16 16 i 13 ! 7.0 i 15 9.4 1 % to 4 Inch or 8.0 4.9 X 4.9 4.9 1 49.2 I 48.5 156.8' 1 65.0 '/+ recessed 2.4 Sloped Ceilings! V2732 12 X 12 12 I 17 12.0 i 19 1 15.0 1 IA to 4 Inch or 8.0 up to 4/12 i 3.7 X 3.7 1 3.7 64.3 83.0 i 71.9 L 103.0 ! 1/+ recessed 2.4 (itch°) Pilch If ! V2732 14 X 14 14 j 17 12.0 1 1 19 ! 15.0 1 %to 4Inch or 8.0 4.3 X 4.3 4.3 i 64.3 I 83.0 71.9 I 103.0 i 1/ recessed 2A V2732 16X 16 16 1 17 12.0 19 15.0 1'/ato4Inch or 8.0 4.9 X 4.9 ! 4.9 64.3 i 83.0 ! 71.9 103.0 1/ recessed 2A V2732 18X18 18 17 12.0 19 j 15.0 i 1Meto4inch or 8.0 5.5 X 5.5 5.5 64.3 83.0 71.9 103.0 '/ recessed 2.4 V2732 20 X 20 20 20 16.7 21 18.4 ; 1 1/5to 4 inch or 8.0 6.1 X61 i 12 X 12 I 6.1 12 i 75.7 , _.. 15 i 1149 9.4 795 20 j 1270 16.7 '/.recessed 1 % to 41nch or 24 8.0 V2730 3.7 X 3.7 i 3.7 56.8 { 65.0 75.7 1..-14_ 114.9 '/+recessed 2.4 V2730 14X14 i 14 -- 15 9.4 20 16.7 !. 1'Ato4Inch or 8.0 4.3 X 4.3 ; 4.3 56.8 65.0 75.7 114.9 1/4recessed 2A V2730 16X 16 16 _.....d.._....._ 15 .. 9.4 20 16.7 i - 1 %to 4 inch or 8.0 4.9 X 4.9 4.9 56.8 65.0_ 75.7 I 114.9 ; 3/+ recessed 2A I V2732 Sloped Ceilings; 12 X 12 j 12 17 12.0 23 22.0 1 %to 4 Inch or 8.0 up to 8/12 3.7 X 3.7 3.7 64.3 j 83.0 1 87.1 152.0 /+ recessed 2.4 (33.7°) i V2732 14 X 14 ! 14 17 12.0 23 ! 22.0 i 1 % to 4 Inch or 8.0 Pitch # 4.3 X 4.3 4.3 64.3 83.0 '• 87.1 152.0 1 1/ recessed 2A V2732 16X 16 i 16 17 12.0 23 ; 22.0 i 1 '/a to 4 Inch or 8.0 4.9 X 4.9 4.9 64.3 83.0 8Z7 152.0 ; '/+ recessed 2.4 i V2732 18 X 18 I 18 17 12.0 I 23 22.0 1 3/5to 4 Inch or 8.0 5.5 X 5.5 ' 5.5 64.3 83.0 87.1 152.0 1/+ recessed 2A V2732 20 X 20 20 1 26 28.2 1 1/a to 4 Inch or 8.0 6.1 X 6.1 6.1 ! 98.4 194.0 1/+ recessed 2.4 Notes: A For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. For systems designed to NFPA 13, the number of design sprinklers is to be the four most demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the flow rates provided In the table for NFPA 13D and 13R systems and the maximum allowable coverage area or a minimum discharge of 0.1 gpmlfL2 over the design area of the four most demanding sprinklers for the actual coverage areas being protected by four sprinklers. #Where sprinklers are Installed on sloped ceilings up to 8112 pitch In NFPA 13D 2010 the Flat Horizontal Ceiling flows may be used for certain configurations. Refer to NFPA TIA 1028R for allowable Installation criteria using Horizontal Ceiling Flows. - VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. A-c-ta-ulicr 40.41_6 REV D FFIIRE PROTECTION PRODUCTS —AUTOMATIC SPRINKLERS 1 K4.9 Residential Pendent, Recessed Pendent and Specific Application (Flat, Sloped & Beamed Ceilings) V2730 QUICK RESPONSE V2732 QUICK RESPONSE NOMINAL WETTING PATTERNS Model V2730 K4.9 Residential Pendent and Recessed Pendent 13GPM/49.2 LPIM — 12' x 1273.6 x 3.6m coverage area 2,gm.____ ._.._ ..__.. . _ _. 1 ...._.__._ ._._ _._ .......-.._'i a 2.1m g q•• ___._ _ _ r __ 1.2mt • 0,8m . IAm tam oAm21 . tl �. i I oAm oAm 4 �OFROOM Y Model V2732 K4.9 Residential Pendent and Recessed Pendent 13 GPM/49.2 LPM —12' x 1273.6 x 3.6m coverage area 2A m [.,...,. ttml 6' 0,9mi 2,;_ is 4. oe m; .i IAm 1.1m OAm i r, I m f 0,3m, �OF�ROOM a CA. .._. ._._... ..._.. _ ,..__... ...... www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2012 VICT ULIC COMPANY. ALL RIGHTS RESERVED. REV_D 40.41 AitauliC' 40.41_7 FIRE PROTECTION PRODUCTS — AUTOMATIC SPRINKLERS 40.41 V277 K4•9 Residential Pendent, Recessed Pendent and Specific Application (Flat, Sloped & Beamed Ceilings) V2730 QUICK RESPONSE V2732 QUICK RESPONSE NOMINAL WETTING PATTERNS Model V2730 K4.9 Residential Pendent and Recessed Pendent 13GPM/49.2 LPM —14' x 1474.3 x 4.3m coverage area um LI m, �JI , l 1.9 m --. VM 4 i 0,9 Obmi IA. tam CA. 1 a. IAm ., 1" - ... 0'3 m r fL OFROOM -. Model V2732 K4.9 Residential Pendent and Recessed Pendent 17 GPM/64.3 LPM —18' x 1875.5 x 5.5m coverage area i SI 1 lbmJ' _._. I 1 _ - I , I i I I 4'r 1.2mJ 4J __ 3 t •'IA, ]Am IA. Iim OAm _ _. f IA. 0,3m1 �: -�� um OF'ROOM i VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. Aic—ta—uhcr 40.41_8 REV_D FIRE PROTECTION PRODUCTS -AUTOMATIC SPRINKLERS 40.41 V271 K4e9 Residential Pendent, Recessed Pendent and Specific Application (Flat, Sloped & Beamed Ceilings) V2730 QUICK RESPONSE V2732 QUICK RESPONSE NOMINAL WETTING PATTERNS Model V2730 K4.1 Residential Pendent and Recessed Pendent I 13GPM/49.2 LPM —16' x 1674.9 x 4.9m coverage area 2Ami0. - j1 0,9 obm 6]4m lam um cam 1 - 1,F lam0,3m •'"Oam fEOFROOM , Model V2732 l K4.9 Residential Pendent and Recessed Pendent 20GPM/75.7 LIPM — 20' x 2076.1 x 6.1m coverage area a g ZIM ,gym - r �,' 5 s , w : JJi O,eml 6,2,4W3.0. ]Am lam Ilm Q6m ,- �OF,ROOM a` NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate wall -wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance and should not be used as minimumi sprinkler spacing rules for installation. Sprinkler location shall be in accordance with the obstruction rules for residential sprinklers in NFPA 13 (2002 or later revision). Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patteri s are symmetrical to waterway. ' www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2012 VIC IAULIC COMPANY. ALL RIGHTS RESERVED. A—taUII[:° REV_D 40.41_9 FIRE PROTECTION PRODUCTS —AUTOMATIC SPRINKLERS 40.41, V277 K4"9 Residential Pendent, Recessed Pendent and Specific Application (Flat, Sloped & Beamed Ceilings) V2730 QUICK RESPONSE V2732 QUICK RESPONSE BEAMED CEILINGS Installation Guidelines The Victaulic Model V2730 and V2732 Residential Pendent Sprinklers are UL Listed for use in beamed ceilings in residential occupancies. These sprinklers can be installed in or adjacent to non- combustible, combustible, solid or hollow -core beams with solid surfaces per the following guide- lines. See the Room Size section on page 4 for specific flow/pressure requirements for hydraulic design. . Primary Beams: The main longitudinal beams attached directly to a smooth flat horizontal ceiling of any height. Secondary Beams: The beams running perpendicular to the primary beams, attached directly to a smooth flat horizontal ceiling of any height. Beam Cross Section: The maximum allowable beam depth is 14". The secondary beam depth can- not be greater than the primary beam depth. The width is unlimited. The cross section can vary between rectangular and circular. Beam Spacing: • Primary Beams: The distance from the wall to the center of the nearest primary beam must be at least 34" and not more than 3k the Listed sprinkler spacing. • Secondary Beams: The beam pockets created by the primary beams cannot exceed 20 ft. in length. If the primary beams exceed 20 ft., then a secondary beam must be placed such that the pocket created does not exceed 20 ft. When a secondary beam is placed for this reason, then the secondary beam must be of a depth equal to the primary beams. When the primary beams are less than 20 ft., secondary beams are not required, but may be placed at any distance from the wall and at any center to center distance between beams. Lintels: Are required over doorways exiting the compartment. The minimum lintel height is 8 inches or at least the depth of the primary beams, whichever is greater. Soffit and Beam combinations: Soffits may be installed around the room perimeter. The beams would then be placed within the soffited area. There is no limitation for the size of the soffit as long as the water distribution is not impaired per the obstruction rules in NFPA 13 for Residential sprin- klers. Beam pockets would then be measured from the face of the soffit. The sprinkler coverage area shall be spaced off the walls. Sprinkler Location: The sprinklers must be located below the underside of the beams, not in the beam pockets. The deflector shall be within 13b6 and 11146" off the bottom of the primary beam. The horizontal distance between the centerline of the sprinkler and the edge of the primary beam cannot be more than 2". VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. ® 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 40.41_10 ✓ctaulid REV_D FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 40.41 V277 K4.9 Residential Pendent, Recessed Pendent and Specific Application (Flat, Sloped & Beamed Ceilings) V2730 QUICK RESPONSE V2732 QUICK RESPONSE A --CAUTION', • A structural engineer must be consulted before drilling into beams to install drops. If drilling into the bgam is not allowed, then the drop may be installed adjacent to the primary beam per the dimensions above. 1-11/16" (42,8 mm) Max. 1-3/16"" (30,2 mm) Min. POSITIONING UNDER BEAMS 1-11/16" (4an � �n �Nj J�� 1-3/16- (30,2 n I- Vfctaulic Maximum 1/2 Residential Pendent Sprinkler Beam width � SIN V2730, V2732 Plus 2Inches dent Sprinkler SIN V2730, V2732 www.victaulic.com Ac—taU�iC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_D 40.41_11 FIRE PROTECTION PRODUCTS — AUTOMATIC SPRINKLERS 40.41 " Residential Pendent, Recessed Pendent and Specific Application (Flat, Sloped & Beamed Ceilings) V2730 QUICK RESPONSE V2732 QUICK RESPONSE BEAMED CEILING ARRANGEMENTS PRIMARY BEAM SPANS UP TO 20'- 076.1 m FIGURE 3A All dimensions are measured to wall faces and to centerlines of beams. A = Distance from wall to nearest primary beam: Minimum: 3' - 471.0 m; Maximum: No more than tk listed sprinkler spacing. B = Spacing between primary beams: 20'- 07/6.1 m maximum C = Beam depth: 14/356 mm maximum. D = Beam span: 20'- 07/6.1 m maximum. COMBINATIONS OF PRIMARY AND SECONDARY BEAMS FIGURE 3C Calling Prime Bet Se All dimensions are measured to wall faces and to centerlines of beams. A = Distance from wall to nearest primary beam: Minimum: 3' - 471.0 m; Maximum: No more than 'i listed sprinkler spacing. B = Spacing between primary beams: 20'- 076.1 m maximum C = Beam depth: 149356 mm maximum. Note: Secondary beam depth cannot be greater than the primary beam. D = Secondary Beam Spacing: Secondary beams may be spaced at any distance, unless primary beam spans exceed 20'- 076.1 m. PRIMARY BEAM SPANS GREATER THAN 20'- 076.1 m FIGURE 3B All dimensions are measured to wall faces and to centerlines of beams. A = Distance from wall to nearest primary beam: Minimum: 3' - 47/1.0 m; Maximum: No more thank listed sprinkler spacing. ` B = Spacing between primary beams: 20 - 076.1 m maximum C = Beam depth: 147356 mm maximum. D = Secondary Beam Spacing: 20'- 07/6.1 m) maximum spacing Secondary beams are to be equal in depth to primary beams and are required so that the primary beam pockets do not exceed 20'- 076.1 m. BEAM AND SOFFIT ARRANGEMENTS FIGURE 3D Face of Soffit Bottom of Soffit D = Use the dimensions shown in Figures 3A, 3B, and 3C, except that measurements are taken from the face of the soffit instead of from the wall surface. - NOTE: The sprinkler area of coverage is to be measured from the wall. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. �CtaUI1Cr 40.4112 REV_D V277 K409 Residential Pendent, Recessed Pendent and Specific Application (Flat, Sloped & Beamed Ceilings) V2730 QUICK RESPONSE V2732 QUICK RESPONSE WARRANTY Refer to the section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change pr duct specifications, designs and standard equipment without notice and without incurring obligatio s. For complete contact information, visit www.victaulic.com 40.41 3533 REV D UPDATED 03/2012 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 40.41 1 ✓ctaulid Fire Protection Products BLAZEMASTER CPVC Fire Sprinkler Submittal Sheet General Description TYCO CPVC Pipe and Fittings pro- duced by Tyco Fire Protection Prod- ucts (fFPP) are designed exclusively for use in wet pipe automatic fire sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC compound That is a specially developed thermo- plastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TYCO CPVC Pipe and Fittings are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapt- ers are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. Ism The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- -taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions, Page i of 2 Tech. Data Sizes 3/41nch thru Maximum 1 175 psi Approvals UL and C-UL FM Approved (Refer to in! dated June, information.) Material Pipe' ASTM F442, Fittings: ASTM F438 ASTM F439 ASTM F197( Color Orange & Fittings lical Inch orkin9 Pressure lation Handbook IH 1900 3 for exact listing/approval Source R 13.5 ,. 40) �. 80 I APRIL 2016 Worldwide wwwtyco-fire.com Contacts instailation TYCO CPVC Pipe and Fittings are to be to be installed in accordance with Installation Handbook IH 1900 dated April 2016. TFP1915 TFP1915 Page 2 of 2 Care and Maintenance TYCO CPVC Pipe and Fittings are to be maintained and serviced in accordance with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible forthe inspec- tion, testing, and maintenance of their fire protection system and de -vices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authority having juris- diction. Contact the installing contrac- tor or product manufacturer with any questions. Automatic sprinkler systems should be Inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Ling For GLOBAL HEADQUARTERS 11400 ty s and conditions, visit Parkway, Lansdale, PA 19446 1 Telephone +1 215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights BLAZEMASTER is a trademark of The Lubrizol Corporation. tqc® Fire Protection Products