HomeMy WebLinkAboutPRODUCT REVIEW AFFIDAVITf '
Planning and Dfehf �menftf Department
Building and Regulations Division
Product Review Affidavit
Building Permit # 920165065
Owners name Stephens Barrios Applicant Stephens Barrios
CO
On ARM13 ; IL
%AUG 2 2.201��
�T�qED •ARG�
Product
Opening Design
Product Rated
Manufacturer
Model .
Product Approval
Glass
Method of Attachment
Pressures
Design Pressure
Number
Number
Type
Fixed Glass
46.1 / -61.7
90 / -90
Old Castle Building
FG-5100
FL-17688.4 R2
Impact
3/8" DIA -16 Elco Const Products drill flex screw to 1/4" min
Envelope
Rated
thk ASTM A-36 Steel @ 41/2" o.c. Max.
Swing Type Door
46.1 / -61.7
70 / -80
Old Castle Building
MSD-375
FL-17693.1
Impact
1/4" dia. -20 FH Elco Drill Flex self drilling screws
Envelope
Rated
Swing Type Door
46.1 / -61.3
70 / -70
Ceco Door Products
Windstorm
FL-10723-115
N/A
Door attached to frame w/ 3 butt hinges
sin le 3070
Swing Type Door
46.1 / -61.7
70 / -70
Ceco Door Products
Windstorm
FL-10723-115
N/A
3/8" DIA -16 Elco Const Products drill flex screw to 1/4" min
Frame
single 3070
thk ASTM A-36 Steel @ 6" from ends and 21" o.c. max
intermediate spaces
Swing Type Door
46.1 / -61.7
70 / -70
Ceco Door Products
Windstorm
FL-10723-115
N/A
Doors attached to frame w/ 3 butt hinges
— - - — - - - - -- -
—
Pair 3070—
—
Swing Type Door
46.1 / -61.7
70 / -70
Ceco Door Products
Windstorm
FL-10723-115
N/A
3/8" DIA - 36 Elco Const Products drill flex screw to 1/4" min
Frame
Pair 3070
thk ASTM A-36 Steel @ 6" from ends and 21" o.c. max
intermediate spaces. 4 at head min. 6" max from CL of head,
6" max from each hinge jamb.
Roofing
18.7 / -116.3
107.4 / -117.8
MBCI
24 GA
FL-11817.2
N/A
HW-2124 2" Sliding clip at each purlin, attach w/ (2) 1/4"-14 x
Double-Lok
1" Driller w/ hex washer head and sealing washer.
Metal Siding
46.1 / -61.7
72.5 / -77
MBCI
26 GA PBR
FL-11719.5-R2
N/A
1/4-14 X 11/4 Long Life Self driller w/ washer
Bahama Shutters
46.1 / -61.7
62 / -75
American Shutter Sys
Extruded
FL-2683-114
N/A
2" x 3" x 3/16" thick Alum angles @ 12" o.c., all sides. Attach
Assoc.
Bertha
to building with (2) 1/4-14 X 11/4 Long Life Self driller and
Bahama
I
I lattach
to louver w/ (3) #10 x 11/2" SMS
I have reviewed the above components or cladding and I have approved their use in this structure. These products prg ide ade uate resistance to the
wind loads and forces specified by the current code provisions.
Name: Harold Daniel Hotter III R.A. Signature:
Design Professional: Architect Cert. No.: AR98913 Date: 08-22-17