Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEI -FORM 405'-'1s0 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Antetomaso Residence Builder Name: SCANNED Street: Lot 1174 SCANNED Permit Office: St. Lucie County City, State, Zip: Jensen Beach, FL , r Permit Number: Owner. 8� Luelp PAlt��s Jurisdiction: Design Location: FL, Fort Pierce IF 1. New construction or existing New (From Plans) 9. Wall Types (1460.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.0 1460.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1674.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1674.00 ft2 6. Conditioned floor area above grade (ft2) 1674 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(194.4 sqft.) Description I Area a. Sup: RoomslnBlock1, Ret: RoomslnBlockl, AH: 6 34.6 a. U-Factor: Sgl, U=0.29 194.40 ft2 SHGC: SHGC=0.30 I b. U-Factor. WA ft2 12. Cooling systems kBtu/hr Efficiency �I SHGC: a. Central Unit 36.0 SEER:15.00 c. U-Factor: N/A i ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 67.8 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.463 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems 8. Floor Types (1674.0 sqft.) Insulation Area a. Electric Cap: a. Slab -On -Grade Edge Insulation R=0.0 1674.00 ft2 b. Conservation features EF: 0!920 b. N/A R= ft2 Add -on Dedicated HeatPump:COP=3.5 c. N/A R= ft2 15. Credits CF, Pstat Total Proposed Modified Loads: 15.37 Glass/Floor Area: 0.116 I PASS Total Standard Reference Loads: 22.85 4'r"V I hereby that the d Review ST.g?- certify plans and spj cification cove of the plans and 0�'4UE this calculation are in compliance with the Florida Energy specifications covered by this _ O� Code. calculation indicates compliance / PREPARED BY: �� a'l�L %l2 �`�s with the Florida Energy Code. Before construction is completed F+ rnr, . °• .:.: "'°:•��� r -' DATE: this building will be inspected for 0 �k a compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. 5,S COD, with the Florida Energy Code. �` �` OWNER/AGENT: BUILDING OFFICIAL: DATE: 1,-3 u - 4-4 ' DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 8/20/26141:30 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 67 The lower the EnergyPerformance Index, the more efficient the home. Lot 1174, Jensen Beach, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.0 1460.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1674.00 ft2 6. Conditioned floor area (ft2) 1674 b. N/A R= ft2 7. Windows" Description Area c. N/A R= ft z 11. Ducts R ft a. U-Factor: Sgl, U=0.29 194.40 ft2 a. Sup: RoomslnBlockl, Ret: RoomslnBlockl, AH: 6 34.6 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 36.0 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 67.8 COP:1.00 Area Weighted Average Overhang Depth: 1.463 ft. Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1674.00 ft2 a. Electric EF: 0.92 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 Add -on Dedicated HeatPump:COP=3.5 15. Credits CF, Pstat I certify that this home has complied with the Construction through the above energy savir in this home before final inspection. Otherwi based on installed Code compliant features. ✓ Builder Signature: 1-�-�"/ 71 )14 lorida Energy Efficiency Code for Building features which will be installed (or exceeded) ;, a new EPL Display Card will be completed Date: F-.SF-- ( y Address of New Home: (('-i4 N �s f5f L, �Cj City/FL Zip: �- s 3ygs7 ;tHE Sr 4 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain ;a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software I PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Antetomaso Residence Bedrooms: 2 FLProp201.0 Conditioned Area: 1674 (Total Stories: 1 1 Worst Case: No Rotate Angle: 0 St. Lucie County Cross Ventilation: Whole House Fan: Single-family I New (From Plans) I Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address Lot 1174 St. Lucie Jensen Beach, FL, CLIMATE / V Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE_CO_INi L 2 39 90 70 75 722 62 Low Ii BLOCKS Number Name Area (Volume 1 Blockl 1674 116740 SPACES I Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 RoomslnBlockl I 1674 16740 Yes 2 2 1 Yes Yes Yes �I FLOORS # Floor Type Space I Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio RoomslnBlockl 1674 ft 0 1674 ft2 0 0 1 ROOF # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip I Metal 1I813 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation I Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1674 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) RoomslnBlockl 30 1674 ft2 0.11 Wood 8/20/2014 1:30 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 w WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space Ft Area - e Fraction Ahsor Cara 1 N Exterior Concrete Block - Int InS6l00mSInBloc 4 42 10 420 ft2 0 0.75 0 2 S Exterior Concrete Block - Int InSEl00msInBloc 4 32 10 320 ft2 0 0.75 0 3 E Exterior Concrete Block - Int InsE1o6msInBIoc 4 32 10 320 ft2 0 0.75 0 4 W Exterior Concrete Block - Int InsRoolmslnBloc 4 40 10 400 ft2 0 0.75 0 I. DOORS # Ornt Door Type Splace Storms U-Value eightln Area In Ft In Ft 1 E Wood RoomslnBloc None 0.460000 3 7 21 ft2 2 E Wood RoomslnBloc None I 0.460000 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall I Overhang v # Ornt ID Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Tinted) Yes 0.29 0.3 N 15 ft2 1 ft 0 in 0 ft0 in HERS 2006 None 2 N 1 Metal Single (Tinted) Yes 0.29 0.3 N 13.5 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 3 i S 2 Metal Single (Tinted) Yes 0.29 0.3 N 108 ft2 1 ft0 in 0 ft0 in HERS 2006 None 4 S 2 Metal Single (Tinted) i s 0.29 0.3 N 15 ft2 1 ft0 in 0 ft0 in HERS 2006 None 5 E 3 Metal Single (Tinted) Yes 0.29 0.3 N 18 ft2 6 ft 0 in 0 ft 0 in HERS 2006 None 6 W 4 Metal Single (Tinted) Yes 0.29 0.3 N 18 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 7 W 4 Metal Single (Tinted) Yes 0.29 0.3 N 6.899999 1 ft 0 in 0 ft 0 in HERS 2006 None INFILTRATION # Scope Method SLA I CFM 50 ELA EgLA ACH ACH 50 1 BySpaces Proposed SLA 0.000360 I 1580.7 86.780 163.20 0.2628 5.6657 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP: 1 67.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 15 36 kBtu/hr 1080 cfrn 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Exterior 0.92 40 gal 50 gal 120 deg Add -on HeatPump:COP=3.5 8/20/2014 1:30 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---Supply -- — ,Return — Air Percent HVAC # # Location R-Value Area Locatii on Area Leakage Type Handler CFM 25 Leakage ON RLF Heat Cool 1 RoomslnBloc 6 34.6 ft2 RoomslnBloc 8.65 ft2 DSE=0.88 RoomslnBl 0.0 cfm 0.00 % 0.00 0.60 1 1 TEMPERATURES Programabl(eXXjThermostat: Ceiling Fans: Heating [X] Jan jY Feb ] EX] Mar Apr IMa May Jun Jun Xi Jul Aug Sep Occtt F r � Nov Nov 0 Dec Dec Venting [X Jan [X] Feb Lx� [Xj Mar ln� l�� X� Thermostat Schedule: HERS 2006 Reference I Hours Schedule Type 1 2 31 4 5 6 7 8 9 10 11 12 Cooling (WD) PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 1 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 1 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 .68 68 68 68 68 68 68 66 66 8/20/2014 1:30 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: Lot 1174 PERMIT #: Jensen Beach, FL, MANDATORY REQUIREMENTS SUMMARYi_ See individual code sections for full details. COMPONENT SECTION i SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage 'report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the! load. Ducts 403.2.2 All ducts,! air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed inj accordance with Section 503.2.7.2 of this code. 403.3.3 1 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) for shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 5Q3.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 8/20/2014 1:30 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5