HomeMy WebLinkAboutENERGY EFFICIENCY CODEI
-FORM 405'-'1s0
FLORIDA ENERGY EFFICIENCY
CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Antetomaso Residence
Builder Name:
SCANNED
Street: Lot 1174 SCANNED
Permit Office: St. Lucie County
City, State, Zip: Jensen Beach, FL , r
Permit Number:
Owner. 8� Luelp PAlt��s
Jurisdiction:
Design Location: FL, Fort Pierce IF
1. New construction or existing New (From Plans)
9. Wall Types (1460.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.0 1460.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1674.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1674.00 ft2
6. Conditioned floor area above grade (ft2) 1674
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(194.4 sqft.) Description I Area
a. Sup: RoomslnBlock1, Ret: RoomslnBlockl, AH: 6 34.6
a. U-Factor: Sgl, U=0.29 194.40 ft2
SHGC: SHGC=0.30 I
b. U-Factor. WA ft2
12. Cooling systems
kBtu/hr Efficiency
�I
SHGC:
a. Central Unit
36.0 SEER:15.00
c. U-Factor: N/A i ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
67.8 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 1.463 ft.
Area Weighted Average SHGC: 0.300
14. Hot water systems
8. Floor Types (1674.0 sqft.) Insulation Area
a. Electric
Cap:
a. Slab -On -Grade Edge Insulation R=0.0 1674.00 ft2
b. Conservation features
EF: 0!920
b. N/A R= ft2
Add -on Dedicated HeatPump:COP=3.5
c. N/A R= ft2
15. Credits
CF, Pstat
Total Proposed Modified Loads: 15.37
Glass/Floor Area: 0.116
I
PASS
Total Standard Reference Loads: 22.85
4'r"V
I hereby that the d
Review
ST.g?-
certify plans and spj cification cove
of the plans and
0�'4UE
this calculation are in compliance with the Florida Energy
specifications covered by this
_ O�
Code.
calculation indicates compliance
/
PREPARED BY: �� a'l�L %l2 �`�s
with the Florida Energy Code.
Before construction is completed
F+ rnr, . °• .:.: "'°:•���
r -'
DATE:
this building will be inspected for
0 �k a
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
5,S
COD,
with the Florida Energy Code.
�` �`
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: 1,-3 u - 4-4 '
DATE:
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
8/20/26141:30 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5
ENERGY PERFORMANCE
LEVEL (EPL)
DISPLAY
CARD
ESTIMATED ENERGY
PERFORMANCE INDEX* = 67
The lower the EnergyPerformance
Index, the more efficient the home.
Lot 1174, Jensen Beach, FL,
1. New construction or existing New (From
Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior R=4.0 1460.00 ft2
b. N/A R= ft2
3. Number of units, if multiple family 1
c. N/A R= ft2
4. Number of Bedrooms 2
d. N/A R= ft2
10. Ceiling Types Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented) R=30.0 1674.00 ft2
6. Conditioned floor area (ft2) 1674
b. N/A R= ft2
7. Windows" Description
Area c. N/A R= ft z
11. Ducts R ft
a. U-Factor: Sgl, U=0.29
194.40 ft2 a. Sup: RoomslnBlockl, Ret: RoomslnBlockl, AH: 6 34.6
SHGC: SHGC=0.30
b. U-Factor: N/A
ft2
SHGC:
12. Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A
ft2 a. Central Unit 36.0 SEER:15.00
SHGC:
d. U-Factor: N/A
ft2 13. Heating systems kBtu/hr Efficiency
SHGC:
a. Electric Strip Heat 67.8 COP:1.00
Area Weighted Average Overhang Depth:
1.463 ft.
Area Weighted Average SHGC:
0.300
8. Floor Types Insulation
Area 14. Hot water systems Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1674.00
ft2 a. Electric EF: 0.92
b. N/A R=
ft2
b. Conservation features
c. N/A R=
ft2
Add -on Dedicated HeatPump:COP=3.5
15. Credits CF, Pstat
I certify that this home has complied with the
Construction through the above energy savir
in this home before final inspection. Otherwi
based on installed Code compliant features.
✓ Builder Signature: 1-�-�"/ 71 )14
lorida Energy Efficiency Code for Building
features which will be installed (or exceeded)
;, a new EPL Display Card will be completed
Date: F-.SF-- ( y
Address of New Home: (('-i4 N �s f5f L, �Cj City/FL Zip: �- s
3ygs7
;tHE Sr
4
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain ;a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
I PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Antetomaso Residence Bedrooms: 2
FLProp201.0 Conditioned Area: 1674
(Total Stories: 1
1 Worst Case: No
Rotate Angle: 0
St. Lucie County Cross Ventilation:
Whole House Fan:
Single-family I
New (From Plans)
I
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
Lot 1174
St. Lucie
Jensen Beach,
FL,
CLIMATE
/
V Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL ST LUCIE_CO_INi L 2 39 90
70
75 722
62 Low
Ii BLOCKS
Number
Name
Area (Volume
1
Blockl
1674 116740
SPACES
I
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
RoomslnBlockl
I
1674 16740 Yes 2
2
1 Yes
Yes Yes
�I FLOORS
#
Floor Type
Space I Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio RoomslnBlockl 1674 ft 0
1674 ft2
0 0 1
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip
I
Metal 1I813 ft2 0 ft2 Medium
0.96
No 0.9
No 0 22.6
ATTIC
V #
Type
Ventilation I Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300
1674 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac
Truss Type
1
Under Attic (Vented)
RoomslnBlockl 30 1674 ft2
0.11
Wood
8/20/2014 1:30 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
w WALLS
Adjacent Cavity Width Height Sheathing Framing Solar
Below
Space Ft
Area -
e Fraction Ahsor
Cara
1 N
Exterior Concrete Block - Int InS6l00mSInBloc 4 42 10
420 ft2
0 0.75
0
2 S
Exterior Concrete Block - Int InSEl00msInBloc 4 32 10
320 ft2
0 0.75
0
3 E
Exterior Concrete Block - Int InsE1o6msInBIoc 4 32 10
320 ft2
0 0.75
0
4 W
Exterior Concrete Block - Int InsRoolmslnBloc 4 40 10
400 ft2
0 0.75
0
I. DOORS
#
Ornt Door Type Splace Storms
U-Value
eightln
Area
In
Ft In
Ft
1
E Wood RoomslnBloc None
0.460000 3
7
21 ft2
2
E Wood RoomslnBloc None
I
0.460000 3
7
21 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall I
Overhang
v #
Ornt ID Frame Panes NFRC U-Factor SHGC Storms
Area Depth Separation Int Shade
Screening
1
N 1 Metal Single (Tinted) Yes 0.29 0.3 N
15 ft2 1 ft 0 in 0 ft0 in
HERS 2006
None
2
N 1 Metal Single (Tinted) Yes 0.29 0.3 N
13.5 ft2 1 ft 0 in 0 ft 0 in
HERS 2006
None
3
i
S 2 Metal Single (Tinted) Yes 0.29 0.3 N
108 ft2 1 ft0 in 0 ft0 in
HERS 2006
None
4
S 2 Metal Single (Tinted) i s 0.29 0.3 N
15 ft2 1 ft0 in 0 ft0 in
HERS 2006
None
5
E 3 Metal Single (Tinted) Yes 0.29 0.3 N
18 ft2 6 ft 0 in 0 ft 0 in
HERS 2006
None
6
W 4 Metal Single (Tinted) Yes 0.29 0.3 N
18 ft2 1 ft 0 in 0 ft 0 in
HERS 2006
None
7
W 4 Metal Single (Tinted) Yes 0.29 0.3 N
6.899999 1 ft 0 in 0 ft 0 in
HERS 2006
None
INFILTRATION
# Scope
Method SLA I CFM 50 ELA EgLA ACH ACH 50
1 BySpaces Proposed SLA 0.000360 I 1580.7 86.780 163.20 0.2628
5.6657
HEATING SYSTEM
#
System Type Subtype Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat None COP: 1
67.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit None SEER: 15
36 kBtu/hr 1080 cfrn
0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubTpe Location EF Cap
Use SetPnt
Conservation
1
Electric None Exterior 0.92 40 gal 50 gal 120 deg Add -on HeatPump:COP=3.5
8/20/2014 1:30 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System
Model # Collector Model # Area
Volume
FEF
None
None
ft2
DUCTS
---Supply --
— ,Return —
Air
Percent
HVAC #
#
Location R-Value Area
Locatii on Area
Leakage Type
Handler
CFM 25
Leakage
ON
RLF
Heat Cool
1 RoomslnBloc
6 34.6 ft2
RoomslnBloc 8.65 ft2
DSE=0.88
RoomslnBl 0.0 cfm
0.00 %
0.00
0.60
1 1
TEMPERATURES
Programabl(eXXjThermostat:
Ceiling Fans:
Heating [X] Jan
jY
Feb
]
EX] Mar
Apr IMa May
Jun
Jun Xi Jul
Aug
Sep
Occtt F r �
Nov
Nov
0 Dec
Dec
Venting [X Jan
[X] Feb
Lx�
[Xj Mar
ln�
l��
X�
Thermostat Schedule: HERS 2006 Reference
I
Hours
Schedule Type
1
2
31 4
5 6
7
8
9
10
11
12
Cooling (WD)
PM
80
80
78 78
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
1
78 78
78 78
78
78
78
78
78
78
PM
78
78
78 78
78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
1
66 66
66 68
68
68
68
68
68
68
PM
68
68
68 68
68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66 66
66 68
68
68
68
68
68
68
PM
68
68
68 .68
68 68
68
68
68
68
66
66
8/20/2014 1:30 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: Lot 1174 PERMIT #:
Jensen Beach, FL,
MANDATORY REQUIREMENTS SUMMARYi_ See individual code sections for full details.
COMPONENT
SECTION
i
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage 'report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the! load.
Ducts
403.2.2
All ducts,! air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed inj accordance with Section 503.2.7.2 of this code.
403.3.3
1
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) for shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 5Q3.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
8/20/2014 1:30 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5