HomeMy WebLinkAboutHVAC LOADSRhvac Residential '8 Light Commercial HVAC Loads; l , Elite_ 1oftware'Development, Inc. Residential Energy Calc's Antetomaso Residence P..ort Saint Lucie, FL 34983.. Pa e 2 Project Report Geneal Pro ect Lnformation. Project Title: Antetomaso Residence Designed By: QEA Associates Project Date: Wednesday, August t 20, 2014 Client Name: Antetomaso Client Address: Lot 1174 Nettles Is�and Client City: Jensen Beach, Florida Company Name: Residential Energy Calc's .mi n.Rata. n Reference City: Fort Pierce, Florida Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 78 59% 50% 75 61 �Ctieck'�Fi • ores ;, _ ` Total Building Supply CFM: 1,'199 CFM Per Square ft.: 0.717 Square ft. of Room Area: 1,674 Square ft. Per Ton: 567 Volume (ft3) of Cond. Space: 16,I lffBLoatls' Total Heating Required Including Ventilation Air: 33,029 Btuh 33.029 MBH Total Sensible Gain: 27,106 Btuh 76 % Total Latent Gain: 8,338 Btuh 24 % Total Cooling Required Including Ventilation Air: 35,444 Btuh •2.95 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. I I i I i C:1... 1Antetomaso Residence.rh9 Wednesday, August 20, 2014, 11:13 AM Rhvac Residential & Light Commercial HVAC Loads , torte somvare uevekopmenz,' in Residential Energy Calcs Antetomaso Residence Pori: Saint Lucie FL .34983 Page 3 Miscellaneous Report Winter: 42 39.4 80% n/a 70 n/a Summer: 90 78 59% 50% 75 61.09 -77 Duct'Sizin "Inputs.:: Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside,Air`Data •' Winter Summer Infiltration Specified: 0.380 AC/hr 0.200 AC/hr 106 CFM 56 CFM Infiltration Actual: 0.344 AC/hr I 0.118 AC/hr Above Grade Volume: X 16,740 Cu.ft. X 16,740 Cu.ft. 5,760 Cu.ft./hr 1,980 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 96 CFM 33 CFM Total Building Ventilation: 45 CFM 45 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.380 AC/hr (106 CFM), Construction: Average Summer Infiltration Specified: 0.200 AC/hr (56 CFM), Construction: Average 1 Supply Attic 16B 0.12 6 452 No 1 Return Attic 16B 0.12 6 167 No C:\ ...\Antetomaso Residence.rh9 Wednesday, August 20, 2014, 11:13 AM Rhvac Residential &Light Commercial HVAC Loads Residential EriergyCalcs� 1 _ a*Elite Software�Development Inc r irk Antetomaso Resitlence: ,. , k Pa" e'4; Load Preview Report Net I ft.' Sen Lat Net Sen Sys Sys Act Duct Scope Ton lion Area Gain Gain Gain Loss CFM CFM CFM Size Building 12 95 567 1,674 27106 8,338 i 35 444 33,029 411 1,199 1,199, _ System 1 _ 2 951 567 1 674 27106 8,338 35,444 } 33,029 • 411 ®I 1,199 12x17 ..._ __. _ _ __ ___ .._ _ _ ...... Ventilation -- 742 _ 1 868 2 610 1 385 Duct Latent 1,602' 1 602 , ----- - - -... ----- - --- - -- Zone 1 -- - - -- - --- -- 74( 26,72 . --- - . 1,233 318 1,644 33,4 11 1,199 12 I -Foyer er 1,100. 5; 6 45 1- _ _ 2-Master Bedroom 3-Walk In Closet 1 -- 272 72 4288 314 _4'8158' 661 47 4,949 361 5,699 836' -4 i 74% 11; 195 14 - 2-6 1-4 4-Master Bath 140 2 424 111 2 535 2 539 33 m 110 2-4 5-Living _._. _ 480 _.. : 4,696 - -.... 527 _- .._ 5,223 ,.. , 5,0561 - - a 661, 2 . 14 .._ 2-6 6-Dining 120 ' 3 745 795 • 4,540, . 2,888 i 381 170 • 2-5 7-Ntchen 130 � 2,981 7821 3,763 , 3,449 - 45!® 1361 2-5 8-Laundry 5 T6 1 911: ^2966, 1134 — 15, - 1-- -- 9-Bath 2 _ r - 60 _ 1 854 _-1,055! 127 1 981 . � 2 541 : 33' ®... 1-5 _.- __. 10-Bedroom 2 196 1,955, 5111 2,466 2,505 33 � -84 89 1-6 11-Walk In Closet 2 48 468 • 95 563 1 559 - i C:1... 1Antetomaso Residence.rh9 i Wednesday, August 20, 2014, 11:13 AM Duct Size Preview Room or Source Minimuml Maximuml Rough.1 Designj SPI Ductl Ductl Htg CIg Act. Duct Duct Name Velocity Velocity Factor L/100 Loss Velocity Length Flow Flow Flow Size System 1 i Supply Runouts 1 Zone 1 1-Foyer Built In 450 750 -- 001 01 _ 576.3 45 2-Master Bedroom Built-in _. 450 - 750! - - 001 � -- 01 - - -- 496.8' 74�'® 2-66 -- 3-Walk In Closet 1 ---. ..-.--- Built In 450 - 750 - 0 01 01 �— - 163.6 - 11 ®...._ _195 14 1-4 4_Master Bath - Built-in 450T_ 0 01 01-�33 M 110 _-2-4 5-Living � _ Built-in - - 45.0 -750 750 - ._ .._ 01 01 544 - _ 6-DiningBuilt-in 450 750 _0 _ 001 01 6248 38 ® 170 2-5 7-Kitchen Built-in 450 750 0.01 0.1 ' 497.4 46 5' 136 _ 2-5 8-Laundry . Built In 450 750 ` 0 01 ; 0.1 637.8; 15, 87 1-5 ..... _. .. - -- ...._ 9-Bath 2 ...._.... _. _ Built-in .__ 45.0 . 750' _ _._. 0 01 01 __. _ .._.. 618.71 .. ---.M 33 .. _.. _ . , 84 . 1-5 10-Bedroom 2 Built-in 450 750 0 01 01 453 1 33 11-Walk In Closet Built -In 450 750 001 ` 01 Other Ducts in System 1 _ _ Supply Main Trunk Built -In 650! 900 0.003, 0.1' 846.7 411' 1,199 12x17 Summary System1 _ - --- --------- ------ - --I I� --- ---, -- -- - -- — - ------- Heating Flow 411 Cooling Flow. 1199 C:\ ...\Antetomaso Residence.rh9 Wednesday, August 20, 2014, 11:13 AM Rhvac • Residential'& Light -Commercial HVAC Loads Elite Software Development, Inc. Residential Energy Calds Antetomaso Residence Port Saint Lucie, FL 34983 3 ^ ; Page: 6 Total BuildinO Summary Loads, = Com` onen4 Area p Sen Lat S'en Total Description Quart Loss Gain Gain Gain 1A-cb-o: Glazing -Single pane, operable window, clear, 220.5 6,665 0 8,409 8,409 . metal frame with break, u-value 1.08, SHGC I0.75 11 D: Door -Wood - Solid Core 42 458 0 426 426 13A-4ocs: Wall -Block, board insulation only, R-4 board 1467.5 5,872 0 3,210 3,210 insulation, open core, siding finish 16C-30: Roof/Ceiling-Under Attic with Insulation onAftic 1674 1,501 0 2,142 2,142 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 173 6,576 0 0 0 insulation below floor, any floor cover, passiLe, heavy moist soil Subtotals for structure: 21,072 0 14,187 14,187 People: 10 2,000 2,300 4,300 Equipment: 1,500 3,300 4,800 Lighting: 0 0 0 Ductwork: 7,618 1,602 6,033 7,635 Infiltration: Winter CFM: 96, Summer CFM: 331 2,954 1,369 544 1,913 Ventilation: Winter CFM: 45, Summer CFM: 45 1,385 1,868 742 2,610 Total Building Load Totals: I 33,029 8,338 27,106 35,444 FCheck Fi uses�MNP .ti .. 01 r F<rj Total Building Supply CFM: 1,199 CFM Per Square ft.: 0.717 Square ft. of Room Area: 1,674 Square ft. Per Ton: 567 Volume (W) of Cond. Space: 16,740 Bwldin w Total Heating Required Including Ventilation Air: 33,029 Btuh 33.029 MBH Total Sensible Gain: 27,106 Btuh 76 % Total Latent Gain: 8,338 Btuh 24 % Total Cooling Required Including Ventilation Air: 35,444 Btuh 2.95 Tons (Based On Sensible + Latent) RNotes r Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. I I I C:1... Wntetomaso Residence.rh9 I Wednesday, August 20, 2014, 11:13 AM i Rhvac Residential 8 Light Commercial HVAC_ Loads Elite;Software Development, Inc. Residential Energy Calds Antetomaso Residence- Port Saint Lucie, FL 34983 ' Page 8 [Detailed Room Loads- Room 1 - Fo er (Average Load Procedure) General' _ Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 10.0 ft. System Number: 1 Room Width: 10.0 ft, Zone Number: 1 Area: 100.0 sq.ft. Supply Air: 79 CFM Ceiling Height: 10.0 ftI. Supply Air Changes: 4.7 AC/hr Volume:. 1,000.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 I Actual Winter Vent.: 5 CFM Runout Air: 79 CFM Percent of Supply.: 6 % Runout Duct Size: 5 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 576 ft./min. Percent of Supply: 4 % Runout Air Velocity: 576 ft./min. Actual Winter Infil.: 11 CFM Actual Loss: 0.273 in.wg./100 ft. Actual Summer Infil.: 4 CFM 1tern Area -U- Htg Sen Clg Lat Sen Descriptign Quanti .. Value HTM Loss HTM Gain Gain S -Wall-13A4ocs 10 X 10 100 0.143 4.0 400 2.2 0 219 E -Wall-13A4ocs 10 X 10 6� 0.143 4.0 244 2.2 0 133 E-Door-11 D 3 X 7 21 0.390 10.9 229 10.1 0 213 E -GIs-IA-cb-o shgc-0.75 100%S 1i 1.080 30.2 544 32.0 0 576 (2) UP-Ceil-16C-30 10 X 10 100 0.032 0.9 90 1.3 0 128 Floor-22A- h 20 ft..Per. 20 1.358 38.0 760 0.0 0 0 Subtotals for Structure: 1 2,267 0 1,269 Infil.: Win.: 11.1, Sum.: 3.8 200 1.710 342 0.315 158 63 Ductwork: 827_ 395 _ Room Totals: _ i i _ 3,436 158 1,727 C:\ ...\Antetomaso Residence.rh9 j Wednesday, August 20, 2014, 11:13 AM ;Rhvac - Residential;8 Light Commercial HVAC Loads; • Elite Software Development, Inc.' ` Re'sidential`Ene'rgy;Calc's,. Residence Port 9 aint Lucie, FL 34983 t .. �_ ., Pa a 9_ Detailed Room Loads - Room 2 -; Master Bedroom (Average Load Procedure) . General Calculation Mode: Htg. & clg. ! Occurrences: 1 Room Length: 17.0 ft. System Number: 1 Room Width: 16.0 ft. zone Number: 1 Area: 272.0 sq.ft. Supply Air: 195 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 4.3 AC/hr Volume: 2,720.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 j Actual Winter Vent.: 8 CFM Runout Air: 98 CFM Percent of Supply.: 4 % Runout Duct Size: 6 in. Actual Summer Vent.: 7 CFM Runout Air Velocity: 497 ft./min. Percent of Supply: 4 % Runout Air Velocity: 497 ft./min. Actual Winter Infil.: 18 CFM Actual Loss: 0.158 in.wg./100 ft. Actual Summer Infil.: 6 CFM -U- Htg Sen Clg Laf Sen ei ; tiom 0111fArea oil@, Quanti Value HTM Loss HTM Gain Gain S -Wall-13A-4ocs 16 X 10 124 0.143 4.0 496 2.2 0 271 W -Wall-13A-4ocs 17 X 10 170 0.143 4.0 681 2.2 0 372 S -GIs-1A-cb-o shgc-0.75 100%S 36 1.080 30.2 1,088 32.0 0 1,152 (2) UP-Ceil-16C-30 17 X 16 272 0.032 0.9 244 1.3 0 348 Floor-22A- h 33 ft..Per. 33 1.358 38.0 1,255 0.0 0 0 Subtotals for Structure: i 3,764 0 2,143 Infil.: Win.: 18.3, Sum.: 6.3 330 1.706 563 0.315 261 104 Ductwork: 1 1,372 981 People: 200 lat/per, 230 sen/per: 12 400 460 Eguipment_ _ _ 0 _ 600 Room Totals: I I I i 5,699 661 4,288 C:\ ...1Antetomaso Residence.rh9 Wednesday, August 20, 2014, 11:13 AM Residential8 Ught Gommerc�al HVAC Loads} Elite Software Development, Inc. IRhvac Residentiaf l=nergy Calds Antetom_ aso Residence P60 Sain"f Lucie' FL:4983 : �' �:< -Pa "e'10 Detailed Room Loads - Room 3 , Walk InCloset 1 (Average Load Procedure) General _ Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 6.0 ft. Zone Number: 1 Area: 72.0 sq.ft. Supply Air: 14 CFM Ceiling Height: 10..0 A. Supply Air Changes: 1.2 AC/hr Volume: 720.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 I Actual Winter Vent.: 1 CFM Runout Air: 14 CFM Percent of Supply.: 8 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 164 ft./min. Percent of Supply: 4 % Runout Air Velocity: 164 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.032 1n.wg./100 ft. Actual Summer Infil.: 1 CFM Area -U- Htg Sen Clg Lat Sen ffie cri,ptiom Quantit Value . HTM Loss HTM Gain Gain W -Wall-13A-4ocs 6 X 10 60 0.143 4.0 240 2.2 0 131 UP-Ceil-16C-30 12 X 6 72 0.032 0.9 65 1.3 0 92 Floor-22A-ph 6 ft.. Per. ;6 1.358 38.0 228 0.0 0 0 Subtotals for Structure: I 533 0 223 Infil.: Win.: 3.3, Sum.: 1.1 60 1.700 102 0.317 47 19 Ductwork: 201 72 Room Totals: i I I 836 47 314 C:\ ...Wntetomaso Residence.rh9 I Wednesday, August 20, 2014, 11:13 AM Rhvac - Resid®ntial 8< Light Commercial HVAC Loads` .; Elite Software Development, Inc. Residential Energy Calc's ; -' _ 3 z �. Antetomaso.Residence Port Saint Lucie, FL 34983 . ,, Pa a 11 Detailed:Room Loads -Room 4 ; Master Bath (Average Load Procedure) Genera„ Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 14.0 ft. System Number: 1 Room Width: 10.0 ft. Zone Number: 1 Area: 140.0 sq.ft. Supply Air: 110 CFM Ceiling Height: 10.0 A. Supply Air Changes: 4.7 AC/hr Volume: ' 1,400.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 I Actual Winter Vent.: 4 CFM Runout Air. 55 CFM Percent of Supply.: 3 % Runout Duct Size: 4 in. Actual Summer Vent.: 4 CFM Runout Air Velocity: 632 ft./min. Percent of Supply: 4 % Runout Air Velocity: 632 ft./min. Actual Winter Infil.: 8 CFM Actual Loss: 0.449 1n.wg./100 ft. Actual Summer Infil.: 3 CFM �P�siption Quantit Value _ HTM Loss HTM Gain Gain W -Wall-13A-flocs 14 X 10 122 0.143 4.0 488 2.2 0 267 W -GIs-1A-cb-o shgc-0.75 20%S 118 1.080 30.2 544 76.6 0 1,379 UP-Ceil-16C-30 14 X 10 140 0.032 0.9 125 1.3 0 179 Floor-22A-ph 14 ft..Per. 14 1.358 38.0 532 0.0 0 0 Subtotals for Structure: 1,689 0 1,825 Infil.: Win.: 7.8, Sum.: 2.7 140 1.707 239 0.314 111 44 Ductwork: 611 555 Room Totals: i i I i i I i I I 2,539 111 2,424 C:1... 1Antetomaso Residence.rh9 I Wednesday, August 20, 2014, 11:13 AM Rhgac Residential &'Light Commercial HVAC Loads-7 Elite Software Development, Inc. Residenttal'Ene� Calc's ntetomaso Reside nce'. Port Saint Lucie FL 34983 Pa a 12'. Detailed Room Loads - Room 5 ,; Living (Average Load Procedure) General` _._ . r Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 30.0 ft. System Number: 1 Room Width: 16.0 ft. Zone Number: 1 Area: 480.0 sq.ft. Supply Air: 214 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 2.7 AC/hr Volume: 4,800.0 cu.ft. Req. Vent. Gig: 0 CFM Number of Registers: 2 Actual Winter Vent.: 7 CFM Runout Air: 107 CFM Percent of Supply.: 3 % Runout Duct Size: 6 in. Actual Summer Vent.: 8 CFM Runout Air Velocity: 544 eft./min. Percent of Supply: 4 % Runout Air Velocity: 544 ft./min. Actual Winter Infil:: 9 CFM Actual Loss: 0.189 lin.wg./100 ft. Actual Summer Infil.: 3 CFM Area -U- Htg Sen C•Ig Lat Sen ���.!.IItem pescgi tion Quant, Vatue. fiTM Loss HTM Gain Gain S -Wall-13A4ocs 16 X 10 88 0.143 4.0 352 2.2 0 193 S -GIs-1A-cb-o shgc-0.75 100%S 72 1.080 30.2. 2,176 32.0 0 2,304 (4) 1 UP-Ceil-16C-30 30 X 16 480 0.032 0.9 430 1.3 0 614 Floor-22A- h 16 ft.. Per. i16 _ _ 38.0 _608 0.0 0 0 _ Subtotals for Structure: -T __-1.358 3,566 0 3,111 Infil.: Win.: 8.9, Sum.: 3.1 160 1.706 273 0.313 127 50 Ductwork: 1,217 1,075 People: 200 lat/per, 230 sen/per: 2 400 460 Room Totals: i i I i 5,056 527 4,696 C:\ ...\Antetomaso Residence.rh9 IWednesday, August 20, 2014, 11:13 AM Rhvac -Residential & Light,Commercial HVAC Loads Elite;Software Development, Inc.' Re4ldential Energy Calc's �_ __ Antetomaso R• .. esidence Poit Sair±t Lucie, FL 34983 .. ; .. . , .. .., Pa a 13' I.Detailed Room Loads -- Room 6 - Dinin , (Average Load Procedure) uGeneral Calculation Mode: Htg. & clg. I Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 10.0 ft. Zone Number: 1 Area: 120.0 sq.ft. Supply Air: 170 CFM Ceiling Height: 10.0 ft. Supply -Air Changes: 8.5 AC/hr Volume: 1,200.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 1 - Actual Winter Vent.: 4 CFM Runout Air: 85 ICFM Percent of Supply.: 2 % Runout Duct Size: 5 in. Actual Summer Vent.: 6 CFM Runout Air Velocity: 625 ft./min. Percent of Supply: 4 % Runout Air Velocity: 625 ft./min. Actual Winter Infil.: 7 CFM Actual Loss: 0.321 in.wg./100 ft. Actual Summer Infil.: 2 CFM item area -U- Htg Sen Clg Lat Sen` ®rescr ption Quanti. Value HTM Loss HTM S l 0 REain Gaim.. S -Wall-13A-flocs 12 X 10 84 0.143 4.0 336 2.2 0 184 S -GIs-lA-cb-o shgc-0.75 100%S 1.080 30.2 1,088 32.0 0 1,152 (2) I36 UP-Ceil-16C-3012 X 10 1120 0.032 0.9 108 1.3 0 154 Floor-22A--ph 12 ft.. Per. _112 _ 1._3_5_8 3_8_.0 456 0.0 0 0 Subtotals for Structure: 1,988 0 1,490 Infil.: Win.: 6.7, Sum.: 2.3 20 1.708 205 0.317 95 38 Ductwork: 695 857 People: 200 [at/per, 230 sen/per: 2 400 460 Equipment: 300 900 Room Totals: I I i I I I 2,888 795 3,745 C:\ ...Wntetomaso Residence.rh9 I Wednesday, August 20, 2014, 11:13 AM Rhvac - Residential & Light'CommerciaLHVA_C Loads Elite Software Development, Inc.' Residential Energy Calds Antetomaso Residence Port'Saint Lucie, FL 34983 Page 14 Detailed Room Loads - Room 7i Kitchen, (Average Load Procedure) GemerafMINE IIIIIIIIIIIIII Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.0 ft. System Number: 1 Room Width: 10.0 ft. Zone Number: 1 Area: 130.0 sq.ft. Supply Air: 136 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 6.3 AC/hr Volume: 1,300.0 �cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 I Actual Winter Vent.: 5 CFM Runout Air: 68 ICFM Percent of Supply.: 4 % Runout Duct Size: 5 in. Actual Summer Vent.: 5 CFM Runout Air Velocity- 497 ft./min. Percent of Supply: 4 % Runout Air Velocity: 497 ft./min. Actual Winter Infil.: 13 CFM Actual Loss: 0.2041 in.wg./100 ft. Actual Summer Infil.: 4 CFM ;Item Area -U- Htg Sen Clg Lat Sen 0escNA55 Quanti Value HTM Loss HTM Gain Gain S -Wall-13A-4ocs 13 X 10 118 0.143 4.0 472 2.2 0 258 E -Wall-13A-4ocs 10 X 10 100 0.143 4.0 400 2.2 0 219 S -GIs-1A-cb-o shgc-0.75 100%S 112 1.080 30.2 363 32.0 0 384 UP-Ceil-16C-30 13 X 10 130 0.032 0.9 116 1.3 0 166 Floor_22A-ph 23 ft_Per._ _ 23 1_358 38.0 875 0.0 0 0 Subtotals for Structure: I 2,226 0 1,027 Infil.: Win.: 12.8, Sum.: 4.4 230 1.709 393 0.313 182 72 Ductwork: I 830 682 Equipment: I 600 1,200 Room Totals: I i I I I 3,449 782 2,981 C:\....\Antetomaso Residence.rh9 I Wednesday, August 20, 2014, 11:13 AM Rhvac - Residential & Light Commercial_HVAC Loads, Elite Software Development, Inc. Residential Energy Calc's Antetomaso Residence Port'Saint Lucie, FL 34983 Page 15 Detailed Room Loads - Room 8 - Laund (Average Load Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 8.0 ft. System Number: 1 Room Width: 7.0 h. Zone Number: 1 Area: 56.0 'sq.ft. Supply Air: 87 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 9.3 AC/hr Volume: 560.0 �cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: I 87 CFM Percent of Supply.: 2 % Runout Duct Size: 5 1 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 638' ft./min. Percent of Supply: 4 % Runout Air Velocity: 6381 ft./min. Actual Winter Infil.: 4 CFM Actual Loss: 0.334I in.wg./100 ft. Actual Summer Infil.: 1 CFM A rod'` si' }; ) :< y h' ¢ aArea� ;�,� V _ 2Htg� ` Sent s Clg t� A3 tjSen Descnptlon 4� s.: , �`Quantl " _�UaluexTM ? 4x.. uLoss HTM ;,,Gam. s4 :Gam:: E -Wall-13A-flocs 7 X 10 149 0.143 4.0 196 2.2 0 107 E-Door-11 D 3 X 7 121 0.390 10.9 229 10.1 0 213 UP-Ceil-16C-30 8 X 7 j 56 0.032 0.9 50 1.3 0 72 Floor-22A-ph 7 ft..Per. 7 1.358 38.0 266 0.0 0 0 Subtotals for Structure: 741 0 392 Infil.: Win.: 3.9, Sum.: 1.3 170 1.714 120 0.314 55 22 Ductwork: 273 437 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: i 600 600 Room Totals: I I 1,134 1,055 1,911 C:\ ...Wntetomaso Residence.rh9 Wednesday, August 20, 2014, 11:13 AM Rhvac - Residential & Light CommercialHVAC Loads. EnergyCaic's Port Saint Lucie, FL 34983 Elite:Software Development, Inc.,Residential Antetomaso Residence Page 16 Detailed Room Loads - Room 9- Bath 2 (Average Load Procedure) General Calculation Mode: Htg. & clg. , Occurrences: 1 Room Length: 10.0 ft. System Number: 1 Room Width: 6.0 A. Zone Number: 1 Area: 60.0 sq.ft. Supply Air: 84 CFM Ceiling Height: 10.0 ,ft. Supply Air Changes: 8.4 AC/hr Volume: 600.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 4 CFM Runout Air: 84 CFM Percent of Supply.: 4 % Runout Duct Size: 51 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 619 ; ft./min. Percent of Supply: 4 % Runout Air Velocity: 619 ft./min. Actual Winter Infil.: 9 CFM Actual Loss: 0.315I in.wg./100 ft. Actual Summer Infil.: 3 CFM Item Area -U= Htg Sen Clg Lat Sen_. ©escription Quantit Value HTM Loss HTM Gain_ Gain E -Wall-13A4ocs 6 X 10 46.5 0.143 4.0 186 2.2 0 102 N -Wall-13A-4ocs 10 X 10 100 0.143 4.0 400 2.2 0 219 E -GIs-1A-cb-o shgc-0.75 27%S 13.5 1.080 30.2 408 72.7 0 982 U P-Ceil-1 6C-30 10 X 6 i 60 0.032 0.9 54 1.3 0 77 Floor-22A_ph 16 ft..Per_ _ _ 16 _1.358 38.0 608 0.0 0 0 Subtotals for Structure: 1,656 0 1,380 Infil.: Win.: 8.9, Sum.: 3.1 160 1.706 273 0.313 127 50 Ductwork: 612 424 Room Totals: I i i I I i I 2,541 127 1,854 Q\ ...\Antetomaso Residence.rh9 Wednesday, August 20, 2014, 11:13 AM Rhvac - Residential 8 Light Commercial HVA_C Loads Elite Software Development, Inc.' 'Residential Energy £ales Antetomaso Residence Port Saint Lucie, FL 34983 Pa a 17 Detailed Room Loads - Room 10 - Bedroom 2 (Average Load Procedure) Y-: d4 <�G�.,}'1 Lt '.t General .. �: .. ���., ,,��.:�_� � �.�,. Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 14.0 ft. System Number: 1 Room Width: 14.0 -ft. Zone Number: 1 Area: 196.0 sq.ft. Supply Air: 89 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 2.7 AC/hr Volume: 1,960.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 ; Actual Winter Vent.: 4 CFM Runout Air: 89' CFM Percent of Supply.: 4 % Runout Duct Size: 6 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 453 ft./min. Percent of Supply: 4 % Runout Air Velocity: 453 ft./min. Actual Winter Infil.: 8 CFM Actual Loss: 0.132 in.wg./100 ft. Actual Summer Infil.: 3 CFM #k�Area� 7 l�J Htg Sen t .t `� Clg�WL' �" } .. i Value Ps " Lossr a HTMamRa 9.:�G2ua. 3 . :���< , ,. ,, �,Gau- N -Wall-13A4ocs 14 X 10 ;125 0.143 4.0 501 2.2 0 273 N -GIs-1A-cb-o shgc-0.75 100%S 15 1.080 30.2 454 32.0 0 480 UP-Ceil-16C-30 14 X 14 196 0.032 0.9 176 1.3 0 251 Floor-22A-ph 14 ft.. Per. 14 1.358 38.0 532 0.0 0 0 Subtotals for Structure: 1,663 0 1,004 Infil.: Win.: 7.8, Sum.: 2.7 ! 140 1.707 239 0.314 111 44 Ductwork: 603 447 _People: 200 lat/per, 230 sen/per: 2 400 460 Room Totals: 2,505 511 1,955 C:\ ...\Antetomaso Residence.rh9 i Wednesday, August 20, 2014, 11:13 AM Rh, Commerclial ,HVAC Loadsz Elite,Soflware'Development, Residential Energy Cald' . Y Antetomaso Residence Port'Sainf Lucie, FL 34983:' 'Page 18, Detailed Room Loads - Room 11 -1Walk In Closet 2 (Average Load Procedure) General,Ili 1 Calculation Mode: Htg. & clg. I Occurrences: 1 Room Length: 8.0 ft. System Number: 1 Room Width: 6.0 ft. Zone Number: 1 Area: 48.0 sq.ft';. Supply Air: 21 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 2.7 AC/hr Volume: 480.0 cu.ft: Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 21 CFM. Percent of Supply.: 10 % Runout Duct Size: 4 in. I Actual Summer Vent.: 1 CFM Runout Air Velocity: 244 ft./min. Percent of Supply: 4 % Runout Air Velocity: 244 ft./min. Actual Winter Infil.: 7 CFM Actual Loss: 0.069 in.wg./100 ft. Actual Summer Infil.: 2 CFM Item Area -U- Htg Sen C•Ig Lat an Descri tion Ouanti Value HTM Loss HTM Gain Gain N -Wall-13A-4ocs 6 X 10 60 i 0.143 4.0 240 2.2 0 131 W -Wall-13A-4ocs 6'X 10 60 0.143 4.0 240 2.2 0 131 U P-Ceil-1 6C-30 8 X 6 48 0.032 0.9 43 1.3 0 61 Floor-22A-ph 12 ft..Per. 12 1.358 38.0 456 0.0 0 0 Subtotals for Structure: 979 0 323 Infil.: Win.: 6.7; Sum.: 2.3 120 1.708 205 0.317 95 38 Ductwork: 375 107 Room Totals: I I I I 1,559 95 468 I I I i �I I ; lC:\ ...\Antetomaso Residencle.rh9 Wednesday, August 20, 2014, 11:13 AM Rhvac Residential' Light Gommerc�al HYAC Loads " Re9idntial Energy,Calc's Ehte.Software Development, Inc. Antetomaso Residence,. Port'taint Lucie, FL :34983 r :Pa a 19 S stem, T Room -Load Summa ---Zone 1--- 1 Foyer 100 3,436 45 1-5 576 1,727 158 79 79 2 Master Bedroom 272 5,699 74 2-6 497 4,288 661 195 195 3 Walk In Closet 1 72 836 11 1-4 164 314 47 14 14 4 Master Bath 140 2,539 33 2-4 632 2,424 111 110 110 5 Living 480 5,056 66 2-6 544 4,696 527 214 214 6 Dining 120 2,888 38 2-5 625 3,745 795 170 170 7 Kitchen 130 3,449 45 2-5 497 2,981 782 136 136 8 Laundry 56 1,134 15 1-5 638 1,911 1,055 87 87 9 Bath 2 60 2,541 1 33 1-5 619 1,854 127 84 84 10 Bedroom 2 196 2,505 ! 33 1-6 453 1,955 511 89 89 11 Walk In Closet 2 48 1,559 20 1-4 244 468 95 21 21 Ventilation 1,385 742 1,868 Duct Latent 1,602 System 1 total 1,674 33,029 411 27,106 8,338 1,199 1,199 System 1 Main Trunk Size: 12xl7 in. Velocity: 847 ft./min Loss per 100 ft.: 0.103 in.wg g Coolmg+Sensible/Latent ". �i n t FSens�blety L'atent Total' N `xhxSplit����tBtuh"_y� Tons. tuh �ti Btuh`' „ti <w Net Required: 2.95 76% / 24% 27,106 8,338 35,444 Actual: 3.02 770/./ 23% 27,800 8,400 36,200 Equ` rnentData ; . Heating System Cooling System Type: Electric Resistance Standard Air Conditioner Model: RXBHWA10J OR EQUIVALENT RAPM036JEZ OR EQUIVALENT Indoor Model: RHSLHM3617JA OR EQUIVALENT Brand: RHEEM Description: Central Air and Heat CENTRAL AIR 15 SEER Efficiency: 0% 15 SEER Sound: 0 0 Capacity: 35,600 Btuh 36,200 Btuh Sensible Capacity: n/a 27,800 Btuh Latent Capacity: n/a i I i i 8,400 Btuh C:\ ...\Antetomaso Residence.rh9 Wednesday, August 20, 2014, 1:37 PM