413 NETTLES BLVD, JENSEN BEACH, FL, 34957
I. New construction or existing
New (From Plans)
2. Single family or multiple family
Single-family
3. Number of units, if multiple family
1
4. Number of Bedrooms
3
5. Is this a worst case?
Yes
6. Conditioned floor area (ft2)
1799
7. Windows— Description
Area
a. U-Factor: Sgl. U=0.65
266.00 W.
SHGC: SHGC=0.25
b. U-Factor: N/A
ft2
SHGC:
C. U-Factor. NIA
ft2
SHGC:
d. U-Factor; NIA
ft2
SHGC:
Area Weighted Average Overhang Depth:
1.627 ft.
Area Weighted Average SHGC:
0.250
8. Floor Types
Insulation
Area
a. Raised Floor
R=19.0
1799.00 ft2
b. N/A
R=
ft2
c. NIA
R=
ft2
9. Wall Types
Insulation
Area
a. Concrete Block - Ext insul, Exterior
R=4.1
2261.30 ft2
b. Frame - Wood, Exterior
R=11.0
88.33 ft2
c. NIA
R=
ft2
d. NIA
R=
ft2
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
1799.00 ft2
b. NIA
R=
ft2
c. N/A
R=
ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AI -I: Main
6 175
12. Cooling systems
kBtu/hr
Efficiency
a. Central Unit
36.0 SEER:16.00
13. Heating systems
kStu/hr
Efficiency
a. Electric Strip Heat
27.0
COP:1.00
14. Hot water systems
a. Electric Cap: 1 gallons
EF: 0.92
b. Conservation features
None
15. Credits CF
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card Will be completed
based on installed Code compliant features.
Builder Signature: f, yk �-,µ� Date: /,'
Address of New Home: y' 13 City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9/23/2016 3:50 PM EnergyGaugeg) USA - FIeRes2014 - Section R405.4.1 Compliant So 11 as
ltra F-a
FORM R405-2014 !
TABLE 402.4.1.1
AIR BARRIER AND INSUi LATlON INSPECTION COMPONENT CRITERIA
Project Name: GULINO RESIDENCE Builder Name: SHORELINE CONSTRUCTION
Street: 413 NETTLES BLVD
Permit Office: SAINT LUCIE COUNTY
City, State, Zip: JENSEN BEACH, FL, 34957 Permit Number: 1608-0589
Owner: EMANUALE D AND KATHLEEN J GULINO Jurisdiction: SAINT LUCIE COUNTY
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA !
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be: sealed.
Windows, skylights and doors
The space betweenlwindow/door jambs and framing and skylights and
i
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.!
The air barrier shall; be installed at any exposed edge of insulation.
Crawl Space walls
Where provided In lieu of floor insulation, insulation shall be permanently
attached to the crawl lspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
9/23/2016 3:50 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
CiOOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit
None
SEER: 16
36 kBtuthr
1080 cfm
0.8
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
; EF Cap
Use
SetPnt
Conservation
1
Electric
Tankless
Main
6.92 1 gal
60 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert #
Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None
None
ft,
DUCTS
/
— Supply---
— Return —
Air
CFM 25 CFM25
HVAC #
#
Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1
Attic
6 175 W
Attic
18,ft2 Default Leakage
Main
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Cooling Jan
Heating �?C� Jan
Venting Jan
Feb
Feb
Mar
Mar
E
Apr
Apr f
Ma Jun Jul
May 4 Jun 4 Jul
Auge
f AuSep
f
Oct
Oct
Nov
Nov
] Dec
f X] Dec
[[ ]1
Feb
Mar
[X]
Apr [
may. [ Jun [ Jul
[ Aug
Se [X]
Oct
Nov
[ j Dee
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8 9
10
11
12
Cooling (WD)
AM
PM
78
78
78
78
78
78
78 78 78
78
78
78 78
78
78
78
78 78
78
78 78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78 78 78
78
78 78
78
78
78
78 78 78
78
78 78
78
78
78
Heating (WD)
AM
PM
68
68
68
68
68
68
68 68 68
68
68
68 68
6B
68
68
68 68
68
68 68
68
68
68
Heating (WEH)
AM
PM
68
68
68
68
68
68
68 68 68
68 68 68
68
68
68 68
68
68
68
68
68
68
68
68
9/23/2016 3:50 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2014
WALLS
Adjacent
I Cavity
Space
Width
Height
Sheathing Framing Solar
_
Belau
_ 1
N=>SW Exterior
Concrete Block - Ext Insul
Main
4.1
50 8
10
441.7 ft2
0
0 0.3
0
2
E=>NW Exterior
Concrete Block - Ext Insul
Main
4.1
79 8
10
697.8 ft2
0
0 0.3
0
3
S=>NE Exterior
Concrete Block - Ext Insul
Main
4.1
44 8
10
388.7 ft2
0
0 0.3
0
_ 4
W=>SE Exterior
Concrete Block - Ext Insul
Main
4.1
83 8
10
733.2 ft2
0
0 0.3
0
_ 5
E=>NW Exterior
Frame - Wood
Main
11
4 8
10
35.3 ft2
0.23 0.3
0
_ 6
S=>NE Exterior
Frame - Wood
Main
11
6 8
10
53.0 W
0.23 0.3
0
DOORS
# Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft in
1 S=>NE Insulated Main
None
.4
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/
Wall
Overhang
V
# Omt ID
Frame Panes NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1 N=>SW 1
Metal Low-E Single
Yes
0.65
0.25
36.0 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
None
2 N=>SW 1
Metal Low-E Single
Yes
0.65
0.25
30.0 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
None
3 N=>SW 1
Metal Low-E Single
Yes
0.65
0.25
33.3 ft2
5 ft 0 in
1 ft 4 in
Drapes/blinds
None
4 E=>NW 2
Metal Low-E Single
Yes
0.65
0.25
9.0 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
None
5 S=>NE 3
Metal Low-E Single
Yes
0.65
0.25
32.0 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
None
6 S=>NE 3
Metal Low-E Single
Yes
0.65
0.25
6.7 ft2
6 ft 0 in
1 ft 4 in
Drapes/blinds
None
7 S=>NE 3
Metal Low-E Single
Yes
0.65
0.25
30.0 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
None
8 W=>SE 4
Metal Low-E Single
Yes
0.65
0.25
8:0 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
None
9 W=>SE 4
Metal Low-E Single
Yes
0.65
0.25
6.0 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
None
10 W=>SE 4
Metal Low-E Single
Yes
0.65
0.25
9.0 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
None
11 W=>SE 4
Metal Lo%v-E Single
Yes
0.65
0.25
30.0 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
None
12 W=>SE 4
Metal Low-E Single
Yes
0.65
0.25
36.0 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
None
INFILTRATION
#
Scope Method SLA
CFM'50
ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000254
1199.3
65.84 123.83
.1855
5
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat None
COPA
27 kBtufhr
1
sys#1
9/23/2016 3:60 PM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405.2014
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
GULINO RESIDENCE
User
EMANUALE D AND KATHLE
1
SHORELINE CONSTRUCTIO
SAINT LUCIE COUNTY
SAINT LUCIE COUNTY
Single-family
New (From Plans)
Bedrooms: 3
Conditioned Area: 1799
Total Stories: 1
Worst Case: Yes
Rotate Angle: 225
Cross Ventilation:
Whole House Fan:
Address Type:
Lot #
Block/SubDNgsion:
PlatBook:
Street:
County.
City, State, Zip:
Street Address
413 NETTLES BLVD
St. Lucie
JENSEN BEACH,
FL, 34957
CLIMATE
v Design Location TMY Site
IECC Design Temp
Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO BEACH MUNI 2 39 90
70
75 299
62 Low
BLOCKS
Number
Name Area
Volume
1
Blockl 1799
14392
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms
Infif ID Finished Cooled Heated
1
Main 1799
14392 Yes 0
3
1 Yes
Yes Yes
FLOORS
#
Floor Type Space
R-Value
Area
Tile Wood Carpet
1 Raised Floor Main �_ �_
1799 ft2
19
1 0 0
ROOF
/
V/ #
Type Materials
Roof Gable Roof
Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip Metal
1949 ft2 0 ft2 White
0.3
No 0.9
No 0 22.6
ATTIC
/
v #
Type Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic Vented 300 1799 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under At@C (Vented)
Main 30 Blown
1799 ft2 0.11
Wood
9/23/2016 3:50 PM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING
Florida Department of Business and Professional Regulation - Residential
CONSTRUCTION
Performance Method
Project Name: GULINO RESIDENCE
Builder Name: SHORELINE CONSTRUCTION
Street: 413 NETTLES BLVD
Permit Office: SAINT LUCIE COUNTY
City, State, Zip: JENSEN BEACH, FL, 34957
Permit Number: 1608-0589
Owner. EMANUALE D AND KATHLEEN J GULINO
Jurisdiction: SAINT LUCIE COUNTY
Design Location: FL, Fort Pierce
County.: St. Lucie (Florida Climate
Zone 2
I. New construction or existing New (From Plans)
9. Wall Types (2349.7 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 2261.30 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Exterior
c. N/A
R=11.0 88.33 ft2
4. Number of Bedrooms 3
d. NIA
R= ft2
R= ft2
5. Is this a worst case? YeJ
10. Ceiling Types (1799.0 sgfL)
Insulation Area
a. Under Attic (Vented)
R=30.0 1799.00 ft2
6. Conditioned floor area above grade (ft2) 1799
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(266.0 sqft.) Description Area
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Main
R 02
6 175
a. U-Factor: S91, U=0.65 266.00 ft2
SHGC: SHGC=0.25
b. U-Factor: N%A ft2
12. Coding systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
36.0 SEER:16.00
c, U-Factor: N/A ft2
SHGC:
d. U-Factor. N/A ft2
13. Heating systems
kBtu/hr Efficiency
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 1.627 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
6. Floor Types (1799.0 sgft.) Insulation Area
a. Electric Tankless
Cap: 1 gallons
a. Raised Floor R=19.0 1799.00 ft2
b. Conservation features
EF: 0.920
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
CF
Glass/Floor Area: 0.148 Total Proposed Modified Loads: 64.58
® ASS
1�/-� �7
Total Baseline
Loads: 73.84
I hereby certify that the plans and specifications covered by
Review of the plans and
t �t1E ST�7
this calculation are in compliance with the Florida Energy
specifications covered by this
v0,''"a�0�
Code.
calculation indicates compliance
with the Florida Energy Coder:
PREPARED BY,'
Before construction is completed
..�
DATE: -
this building will be inspected for
compliance with Section 553,908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
QQD W
OWNER/AGENT:
BUILDING OFFICIAL.
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and an envelope leakage
test report In accordance with R402.4.1.2.
9/23/2016 3:50 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
;-`wrightsoft® Project Summary Job:
a e: Jun 15, 2016
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Email: QUICKCALCS@AOL.COM
Project• •
For. GULINO RESIDENCE, SHORELINE CONSTRUCTION
LOT 413, NETTLES ISLAND, FL
Notes:
D- .n Information
Weather: Fort Pierce, FL, US
Winter Design
Conditions
Summer Design Conditions
Outside db
42 OF
Outside db
90 OF
Inside db
70 OF
Inside db
75 OF
Design TD
28 OF
Design TD
15 OF
Daily range
L
Relative humidity
50 %
Moisture difference
61 gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure
20895 Btuh
Structure
17952 Btuh
Ducts
5665 Btuh
Ducts
8142 Btuh
Central vent (0 cfm)
0 Btuh
Central vent (0 cfm)
0 Btuh
Humidification
0 Btuh
Blower
0 Btuh
Piping
0 Btuh
Equipment load
26560 Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
24789 Btuh
Method
Simplified'
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
4395 Btuh
Ducts
2213 Btuh
Heating Cooling
Central vent (0 cfm)
0 Btuh
Area (ft2)
1799 1799
Equipment latent load
6608 Btuh
Volume (ft3)
15045 15045
Air changes/hour
0.38 0.20
Equipment total load
31397 Btuh
Equiv. AVF (cfm)
95 50
Req. total capacity at 0.70 SHR
3.0 ton
Heating Equipment Summary
Cooling Equipment Summary
Make
Make Rheem
Trade
Trade RHEEM; RUUD
Model
Cond RA1636AJ 1
AHRI ref
Coil RH1T3621MTAN
AHRI ref 7942208
Efficiency
100 EFF
Efficiency 13.0 EER, 16 SEER
Heating input
7.2 kW
Sensible cooling
25200 Btuh
Heating output
24503 Btuh
Latent cooling
10800 Btuh
Temperature nse
19 OF
Total cooling
36000 Btuh
Actual air flow
1200 cfm
Actual air flow
1200 cfm
Air flow factor
0.045 cfm/Btuh
Air flow factor
0.046 cfm/Btuh
Static pressure
1.00 in H2O
Static pressure
1.00 in H2O
Space thermostat
Load sensible heat ratio
0.80
Bol Haf/c values have been manually overridden
J 8th E
Calculations approved byACCA to meet all requirements of Manual .
AN+ wrig(titsoft-
2015
9
,-,�Q16• 5
I
5
f�,
Right -Suite® Universal 15.0.18 RSU08101
e�
age 1
...Wocuments\Wrightsoft WVAC\GULINO RESIDENCE.rup Caic = MJ8 Front
Door faces: N
wrightsofV Duct System Summary
Entire House
QUICK CALCS, INC.
317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Emall: QUICKCALCSQaAOL.COM
r-roject intormation
For: GULINO RESIDENCE, SHORELINE CONSTRUCTION
LOT 413, NETTLES ISLAND, FL
Extemal static pressure
Pressurelosses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
1.00 in H2O
0 in H2O
1.00 in H2O
0.500 / 0.500 in H2O
1.000 in/100ft
1200 cfm
Job:
Date: Jun 15, 2016
By:
Cooling
1.00 in H2O
0 in H2O
1.00 in H2O
0.500 / 0.500 in H2O
1.000 in/100ft
1200 cfm
212 ft
Supply Branch Detail Table
Name
Design
(13tuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH ROOM
c 830
34
38
1.000
4.0
Ox 0
VIFx
16.3
115.0
St3
BEDROOM 2
h 1824
82
75
1.000
5.0
Ox 0
VIFx
19.4
115.0
St3
BEDROOM 3
h 2074
94
75
1.000
5.0
Ox0
VIFx
18.0
115.0
st3
FOYER
h 1644
74
56
1.000
4.0
Ox0
VIFx
35.9
155.0
sty
INSTA H W
h 1363
62
37
1.000
4.0
Ox 0
VIFx
36.6
175.0
st5
KITCHEN
c 2868
77
132
1.000
6.0
Ox0
VIFx
30:8
155.0
st5
LAUNDRY
c 1506
27
69
1.000
4.0
Ox 0
VIFx
12.5
115.0
stl
LIVING
h 3546
160
124
1.000
6.0
Ox0
VIFx
26.2
135.0
st4
LIVINc-A
h 3546
160
124
1.000
6.0
Ox 0
VIFx
29.0
135.0
st4
M BATH
h 489
22
21
1.000
4.0
OxO
VIFx
15.8
115.0
st1
M wic
h 1041
47
19
1.000
4.0
Ox0
VIFx
30.5
115.0
stl
MASTER BEDROOM
c 2985
90
137
1.000
6.0
Ox 0
VIFx
18.0
115.0
stl
MASTER BEDROOM -A
c 2985
90
137
1.000
6.0
Ox 0
VIFx
19.2
115.0
stl
POWDER
h 1161
52
31
1.000
4.0
OxO
VIFx
37.0
155.0'
st5
$'IAIRSDOWN
c 2079
58
96
11.000
5.0
Ox0
VIFx
17.1
115.0
st3
WIC 2
h 1163
53
22
1.000
4.0
Ox 0
VIFx
31.1
135.0
st7
WIC 3
h 381
17
7
1.000
4.0
Ox 0
VIFx
28.4
135.0
st7
8old/Itadc values have been manually overridden
1 wri htsoft' 2016-Jun-15 00:38:41
li 9 Right-Sulte® Universal 2016 15.0.18 RSLI08101 Page 1
..IDocuments%Wrightsott HVACIGULINO RESIDENCE.rup Cale = MJ8 Front Door faces: N
Name
Trunk
Type
Htg
(cfm)
Clg
(cfm)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
st5
Peak AVF
265
256
1 i000
760
8.0
0 x 0
VinlFlx
st4
st4
Peak AVF
586
503
1.000
746
12.0
0 x 0
VinlFlx
st2
st2
Peak AVF
586
503
1.000
746
12.0
0 x 0
VinlFlx
st7
PeakAVF
70
30
1.000
800
4.0
0 x 0
VinlFlx
st3
st3
Peak AVF
338
313
1.000
765
9.0
0 x 0
VinlFix
st1
Peak AVF
276
384
1 1.000
869
9.0
0 x 0
VINFlx
Return Branch Detail Table
Name
Grill
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Mad
Trunk
rb1
Ox 0
1200
1200
0
0
0
0
Ox 0
VIFx
2015,1un•15 00:38:41
°cwrightsoft° Right -Suite® Universal 2015 15.0.18 RSu08101 Page 2
A06K ...%Documents%Wrightsoft WAC%GULINO RESIDENCE.rup Calc = MJ8 Front Door faces: N
oil
O
t�i S
(� C
CIL
m
Z
n,
m °—'
CD
.00
m�
p O
II �
3
�
a ch
a�
O
0
Z
W A
W
N
O
' O
WAWN�
Ti'fI 0
�
.'�'i ��� �
�
�
� �
�_
�
7 3
m�•��p7j
jNNNNN N->•-.NNN NiN-CNN-+
ID
k am
12
�
Ono 00 O. O
57
�
�
iR�
co�0�oop0pp0p��p0p��g0g��g0q��g0q��g0g��00g0�g0�g0�00y0�0y0�0g0�g0�0
2"'idKi252525252'i25�'ii`8v`'2S2`i�i�'i''u�a2S�'a252`��i
��
T
WCD W m CD 7 7 7
pAp OONND IOI��D NWN pAp OAO OD OAo ONND pA WONt�DA
VV(O(pp ON�D7 OD OND OND 89288
N�8imc0 30000NO00000005000
x
O
�a:
n
00-��WWWWWN�AAANNW(V 6�N AAN
88 zj:l&,88sa 8:49Egg ssa
N
A
99 ' 8 V a rnNVT a O� N tN
�N,�000OOOWNAtD OO FJ �O�Oc000�
W
v
w
00
O
�C77 000
�j
w
ON
01
4�
�tO AOD fD �AfO�VVN��ODAAt)D.OD OVI V•Wi+
WNtO ANA
�
^Q��
T
CD
d
N�000
�
�O
�
�AWONWNmNO�A�W00.CNJ1��
O
OV
Cri
OO bt)OA
c
O
A p G7
O A o w:t o c O O �V 0 0 0 O O O O N N N M A
O
J
O
o`o"0000000N0000000Nomoo�
rx
Q
x V
�W
W�000
�
O•�•1
fD
O�OOD Co00000(AOOOOOOOOt�00D��0�
�
��
O�
V
V 000
00
OA
W
IT
OOOWA O O O 0 to O O O O O O:A: RAC. C0
H
S
N
O
z
+ aightso" Right-M Worksheet Job:
Entire House Date: Jun 15, 2016
QUICK CALCS, INC.
317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Emil: QUICKCALCScQrAOL.COM
1
Room name
WSTA H W
2
E)posed wall
11.0 ft
3
Room height
8.0 ft heat/cod
4
5
Room dimensions
Room area
8.0 x &0 ft
24.0 ft2
Ty
Construction
number
U-value
(Btuh/ftMF)
Or
HTM
(Btuh/ft2)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Area
or perimeter
load
Heat
I Cod
Gross
NIP/S
Heat
Cod
Gross
WP/S
Heat
Cool
6
%t
!`-(G'
13A-4ocs
2 glazing, cir low-e
2 glazing, clr love
0.143
0.650
0.650
n
n
n
4.00
18.20
18.20
2.55
14.99
14.99
0
0
0
0
0
0
0
0
0
0
0
0
y/
t---G
11
13A-4ocs
2 glazing, cir lowe
13A4ocs
2 glazing, clr lowe
M flocs
0.143
0.650
0.148
0.650
0.143
ne
ne
a
a
se
4.00
18.20
4.00
18.20
4.00
255
26.88
2.55
33.77
255
0
0
24
0
0
0
0
24
0
0
0
0
96
0
0
0
0
61
0
0
W
t-G
W
134-4ocs
2 glazing, cir lowe
2 glazing, clr lowe
2 glazing, clr love
11DO
0.143
0.650
0.650
0.650
0.390
s
s
s
s
s
4.00
18.20
18.20
18.20
10.92
2.55
14.99
14.99
14.99
11.31
64
0
0
0
32
32
0
0
0
32
128
0
0
0
349
81
0
0
0
362
13Pr4ocs
2 glazing, clr lowe
2 glazing, cir lowe
2 glazing, cir lowe
2 glazing, cir lowe
0.143
0.650
0.650
0.650
0.650
w
w
w
w
w
4.00
18.20
18.20
18.20
18.20
255
33.77
33.77
33.77
33.77
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
C
2 glazing, cir lowe
2 olazinp, cir lowe
16&30md
0.650
0.650
0.032
w
w
-
18.20
18.20
0.90
33.77
33.77
1.68
0
0
0
0
0
0
0
0
0
0
0
0
F
22AA0
0.989
-
27.69
0.00
24
11
305
0
F
224-tpl
0.989
-
27.69
0.00
0
A
0
0
6
c)AED excursion
-9
Envelope loss/gain
878
495
12
a) infiltration
123
35
b) Room ventilation
0
0
13
Interval gains: Occupants @ 230
0
0
Appliances/other
0
Subtotal (lines 6 to 13)
1001
530
Less extemal load
0
0
Less transfer
0
0
Redistribution
71
23
14
Subtotal
1072
553
15
Duct loads
27%
45%
291
251
Total room load
I
1 1363
837
Air required (cfm)
62
37
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrilghtsof - 2016Jun-15 00:38:35
.49& Right -Suite® Universal 2016 15.0_18 RSLI08101 page 10
...\Documents\Wrightsoft WACWULINO RESIDENCE.rup Calc = MJS Front Door faces: N
+'w`r�ightsoft- Right-JO Worksheet Job:
Entire House Date: Jun 15, 2016
By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Email: QUICKCALCS@AOL.COM
1
Room name
HALLWAY
STAIRS DOWN
2
Exposed wall
0 ft
8.0 It
3
Room height
8.0 ft heat/cool
15.4 ft heat/000l
4
5
Room dimensions
Room area
5.0 x 18.0 ft
90.0 It,
11.1 x 8.0 ft
88.7 ft'
Ty
Construction
U-value
Or
HTM
Area (ft')
Load
Area (ft')
Load
number
(Btuh/ft2-'F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
I Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
%J
13A-0ocs
2 glazing, cir lowe
2 glazing, cir lowe
0.143
0.650
0.650
n
n
n
4.00
18.20
18.20
255
%99
14.99
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
IE--�C`
11
vN
t-G
13A-4ocs
2 glazing, cir lowe
0.143
0.650
ne
ne
4,00
18.20
255
26.88
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
VIJ
t-C
13A4ocs
2 glazing, cir lowe
13A flocs
0.143
0.650
0.143
a
a
se
4.00
18.20
4.00
255
33.77
2.55
0
0
0
0
0
0
0:
0
0
0
0
0
129
0
0
129
0
0
516
0
0
328
0
0
W
13A-4ocs
2 glazing, cir lowe
2 glazing, clr low-e
2 glazing, clr lowe
11D0
0.143
0.650
0.650
0.650
0.390
s
s
s
s
s
4.00
18.20
18.20
18.20
10.92
2:55
14.99
14.99
14.99
11.31
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
13A-0ocs
2 glazing, cir lowe
Q143
0.650
w
w
4.00
18.20
2.55
33.77
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2 glazing, cir low-e
2 glazing, cir lowe
2 glazing, clr lowe
0.650
0.650
0.650
w
w
w
18.20
18.20
18.20
33.77
33.77
33.77
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2 glazing, clr lowe
2 glazinq, cir lowe
16B-90md
0.650
0.650
0.032
w
w
-
18.20
18.20
0.90
33.77
33.77
1.68
0
0
90
0
0
90
0
0
81
0
0
151
0
0
88
0
0
88
0
0
79
0
0
148
C
F
22A4p1
0.989
-
27.69
0.00
0
0
0
0
0
0
0
0
F
22A-tpl
0.989
-
27.69
0.00
0
0
0
0
80
8
222
0
6
c)AED excursion
-3
-24
Envelope loss/gain
81
149
816
452
12
a) Infiltration
0
0
179
51
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
900
Subtotal (lines 6 to 13)
81
149
995
1402
Less edemal load
0
0
0
0
Less transfer
0
0
0
0
14
Redistribution
Subtotal
-81
0
-149
0
15
1010
28
1430
15
Duct loads
27%
45%
0
0
27%
450/0
274
6Q
Total room load
Air required (cfm)
0
0
0
0
1284
58
2079
96
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
A4- wrightsoft- 2016Jun-15 00:38:35
.P, Right -Suite® Universal 2015 15.0.18 RSU08101 Page 9
\Documents\Wrightson HVAC\GULINO RESIDENCE.rup Calc = M.18 Front Door faces: N
xa
m
05
o
m
0
m
C
V
0
O
C
7
P�
C
�iHI
�
�
�
Q'�
�1
.m.
�
1�l'71''L� T
T�i Ci 4)4)4) rar r�
1
�
Z1�71 Z1P
gull
.y.m
�
�3g'
O
��° �aI
NNNNNN�-�NNN�+NON+NNE
nnmcororo 99M 5��9'°°�'nn�'
co
o
0
00 000 0 000 0 0 00
o
W
�
A i f1 961 6 O F 6 A
[if
7
tD
PC
0o� 5o5��OpC�y0�g0�g0�oGpG�po�0009o�0 p0�0
id2� �N'N'2525 2S7S�i' �i8i 92Sg �i'w 8,�258i 2S8 i52i6
o�
�'
� �iiiffifwmmmm�mm��»>
�
VV OOD OD,O�D QD OD ODA OQJ G/ODA AOD A,O�DA 00 W;A'
ED. 8800'808088'88("D88a8888U8
x
�
00--�WWWWWWNsAAAN�VWN OiN A?[J
ERzassER'*8S
O
0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 0 0 0 0 0 0 0 c,
O W
O O
co
_
G
e
Ao'00000a000000�'i00000000
?�
x
xw
o
0�
V0+
-0+0�000
�
OOi
A
WO(LI00000000 OOONO0000000
�
�
v
QQ
V
N 0 0 0
N
O O
O W
��pp
8
N
OOpp
O O V O O O O O O O O O O O A o o O O O O0 O
u
O
NoCnOo00o 00oo000 Too 0o 000
3�
cn O
cox
o
_
o
WO Nc0o Oo00A000 ocD To 000 o00
N
X
O Q
x
x' N
Wj
W!C2n 000
!O2
.Rt
O N OO O CD O OOO O O Oo000000
�j
G
log
NN
00
�Npf N�
IOtOOOOOOO
C
0
0
0
n
nW
b
O
r
O
O
F.
0_
�C O1 Q
eo ..
M u
z
CT A W N
�g�
�'
MC
-+NNNNNN��N N.N--�N->•N-+NN-+
�i
HtX
m f
O
�C
��
co�5o�ogo�go�opo�yo�go�o'yo�Qgo�osooyo�0¢0�0p0�0o
Y�
f F`<e` Fim wVl f/!fO mfpmm� 773
0
V V O OD GD Oo W OD W A O OD OD W A A Oo A• OD A OD OD A
seset3 88Net38888888008
'
�2
OO:+IJW W41W WNW?AANN��VQJNAA[J
8
v
88-49rvdS8sa9-19ss88a
- fOo�000000�oocnoa�i00000000
3�.
o 0
8
oo000000ooinot000000000
_
•
2
x w O
�O
m 3
pppp ��pp
NA
t��p
(D (000
A
OCh
+
N A .a
W+O OOOOOO�OC C OA00000000
j
Sd
"
�Cp
�1
V
CVTI-N+
Wtl1V00
W
O
OOD
O
V
OOOOO OOO ON OOCO OW00000000
N
��11 Op
" o (��1 O o O o O O O O O O O A m O O'A O O O O O
x
G O
� �
o
i
no$l0000000000a�oo�00000
�
C m
x WO
x0
AA
NOiOO
OW
O
(�a N77 V
CJ10 A'OOOOOOOOOO@;0OO 1.000Oo
C
xSR
iC>
" 9 8 0 01..
O A
V
O O N O O O O O O O O O O N N O O 0 0 0 0 0
A
C
A
n
n
m
9
b
9
Fi-
L
N
0
Ol
0000000000000C'O IA 00000�00
1r� fry r
w
�
W 1�
O
O W
2
Ox
0
m C)i x
0000000000000ffi000000�00
c
p
�
a
p
O
N
OOOOOo00oo000 ��t00000�00
O
A
OOO OOOOO 00000 G000O OOR 00
N
1�
010
00
?
00'70O
00
10-D
CD
Uo
x
pj
O O O O O O O O O O 0 0 0 N O O O O O O N O O
c
p
a
0 0 0 o O 0 0 0 o 0 0 0 o N 0 0 0 0 0 ONO O
O
O O
v E
CD N
N
Ogg `u4`$tc3`Iz1180030i$iz;1` rzrz`4`i:lz888
a
NVliNA CJ9NN-`�—i-N9 IC9€3;79 Fg 00
2�
pppp pppppppC�pp pp pp�Q�
ONN ON SNS ON NN070N NNN Ras 8d
�n3
•7 CD CC �aD V'CD��`C7 CO NYO �cO aC1 CG aC1 aD CCC NN
2
�-�
O
ccc��marNmwa�mm3333333� �
��
ooc000000000000000c0000
��
Do
m7 Tm
O O b b O
C
T
2
vo 0 0 000 00000o
0' 0' 0' 0' 0' 0' 0'_
�uco pv � � TXa.
�'
c
`�
5�
O
m
I
T
E
oE
CO �•-
rno rn rn olrnrn wrno�o>w•IJ
NN rC-4 NNN;'rNNNNNNrcl
-�
z
z�
m
w
z
7
cn
v
CD ww
m
rn ccnn
tlt A
W
N
p�
C,
U1
W��mNS5 >
qA
C
m cFi
a m m_m_m m Om rn �o �^'co W� In arc
o
B(a(adZ�,
o
Bc
��
�+$
��oppt�0pp0001f01f0000ac0p0oU0f000a0y0�00a_00,0_p
�p
F F F F F F F N N N N N CD
N N > > > > > >
pVp��V �O�pp Oo tON�)NWN ONNO OND OO pA O,NW>O�o70NO Ap pA ONO OA CO pA OD ONo pA
s�
5N�
OO�VVVVV V(JI +(O f0 f0 C71 ClIV (l1 OD Uf fO (O Of
_
o
oo�00000000000000`�'00000
�'r.
b o
ooZA0000000000CD, 00000000
o
74
x o�
-+
=
x
V =
O
NN
N
Op
A WOO
s
OOVD
�Np
W
N
OO s 0 0 0 0 000000 O O 00A O O O.C,Sr
.:
Y
pp
t
NWA00
pppp
(D
00
N
ON
pNy
V
Gf
N
OOt CD 0000000000000W. 00000
f
O
OO NOO OOO O&oOo0o 00000000
'�
O O
�'v
V
O O N O O O O O O N O O o 0 0 O 0 0 0 0 O 0 0
N
O
x 6z
�v
os
� i°noo
iS
o�
can
00e800001$090000000000000
..
��
�2fi
o�iu�ioo
SQ
�o
om
�
�
00�0000250�0000000000000
V
1
C _
O
m :
Z ul
T O
O
v
m
0
m
m
R
;aa
m
Z
v1A
W
N
v7
�• O
19
av
v
TTCi��
��
5vg1 QAWN-
37
S.
�-
5
S W
_
P
33
g
3
CC
a �753
NNNNNN�+NNN�+N-+N�NN�
�¢+�f pG�fpQ�(0 fG t0 tyG_�OtpC�f0 tp07 �f0 fyC �Cp��,fyO _
�C)
3
N_P�-
NAZ9,92" � t� c� �J, e e
��
oSo5�QpQgo�o9o�go�po�po?oocgo�/cooc000Oco
o�
�'FFFFFFFW0(AWW=m0to632»>
VV OOD CD OOW OD 00 ;P OOD OD OD AAWAOOA W07 A,
vj
OO�VVVVVVv1 +f0 (D CO v1 vl V��C11.tO CD vI
_-
___ __
NNt�t1111
W
7.
OD OD
N
OOODOOWOOOOOOO OO OOOp .A OO otga
��
O O
j ((�� p�p
O`O WOO OOO OOD OOOOOOOA 00 OOpt
SV .Z7
%
WW
pppp
O�
�jp1 t�
+W�DOO
N
CD
A
O+
1��p v1 cpn
_ OO(TOOWOOOOOOOOOOO�OOO�N
x
�
x
(V710
Oppppp� �
WVVOO
�j
06
Ot3V
��pp pNNp�� aa
00�0000 Ov10000000 VIOOOVfO
N
O
aa aa
v10 vf000000000000000�'00 OOtJ
y
�'
C G
�il
e
'ot'n00000000-000000&ooCob
'D
N
W C
•
x
m
p�
v7
O
:1�
is000
co
o^v'
pp��
Pi.
W ' 9
-A O W 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O O
°�°
14-CD(DC>
ICICD109
161
�N�p"tOW OD
R
OOvf00000000000000N00000
m
c
0
0
r
0
0
n
0
K
v
z
wrightsoft' Right-.1® Worksheet Job:
Entire House Date: Jun 15, zols
By:
QUICK CALCs, INC.
317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Email: QUICKCALCS@AOL.COM
1
Room name
FOYER
POWDER
2
Evosed wall
13.0 ft
12.0 ft
3
Room height
8.1 ft heat/cool
8.1 ft heat/cool
4
5
Room dimensions
Room area
7.0 x 6.0 ft
42.0 ft2
6,0 x 6.0 ft
36.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh/ft2-*F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
NIP/S
Heat
Cod
Gross
WP/S
Heat
Cool
6
13A-4ocs
2 glazing, cir low-e
2 glazing, cir low-e
0.143
0.650
0.650
n
n
n
4.00
18.20
18.20
2.55
14.99
14.99
' 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
VN
t-G
13A4ocs
2 glazing, cir low-e
0.143
0,650
ne
no
4.00
18.20
2.55
26.88
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1W
�C
13A4=
2 glazing, cir low-e
13A4ocs
0.143
0.650
0,143
a
a
se
4.00
18.20
4.00
2.55
33.77
Z55
49
9
0
40
0
0
159
164
0
101
304
0
0
0
0
0
0
0
0
0
0
0
0
0
W
13A-4ocs
2 glazing, cir low-e
0.143
0,650
s
s
4.00
18.20
Z55
14.99
57
0
30
0
118
0
75
0
49
0
49
0
195
0
124
0
2 glazing, clr low-e
2 glazing, cir low-e
11DO
0.650
0.650
0.390
s
s
s
18.20
18.20
10.92
14.99
14.99
11.31
0
7
20
0
7
20
0
124
223
0
102
231
0
0
0
0
0
0
0
0
0
0
0
0
13A-4ocs
2 glazing, cir low-e
0.143
0.650
w
w
4.00
18.20
2.55
33.77
0
0
0
0
0
0
0
0
49
4
45
0
179
73
114
135
2 glazing, clr low-e
2 glazing, clr low-e
2 glazing, clr low-e
0.650
0.650
0,650
w
w
w
18.20
18.20
18.20
33.77
33.77
33.77
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2 glazing, clr low-e
2 plazinp, cir low-e
161330md
0.650
0.650
0.032
w
w
-
18.20
18.20
0.90
33.77
33.77
1.68
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
C
F
22A tpi
0.989
-
27.69
0.00
42
13
360
0
36
12
332
0
F
22A tpi
0.989
-
27.69
0.00
0
0
0
0
0
0
0
0
6
c)AED excursion
-14
46
Envelope loss/gain
1147
798
778
418
12
a) infiltration
147
41
135
38
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (litres 6 to 13)
1294
840
914
456
Less odemal load
0
0
0
0
Less transfer
0
0
0
0
14
Redistribution
Subtotal
0
1294
0
840
0
914
0
456
15
Duct loads
27%
45%
351
381
27%
45%
248
207
room load
Air required (cfm)
1644
74
1220
56
--
7�Total
1161
52
663
31
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft- RI ht-Suite® Universal 2015 15.0.18 RSU08101 2016-Jun-15 00:38:35
9 g
C.4�P....\Documents\Wrightsoft HVAC\GULINO RESIDENCE.rup Calc = MJ8 Front Door faces: N Page 3
4 CCCU�
CD OD
i m
N CA
OIA
W
N
O
�• O7
CnAWN�
� ����
�
S
vm
�
v
TmnV T r X
MTWM
BIN
ppppA i�em
+
^
_
I
a-+N
� 003 i
0m
N-�NN�/! m_ rc m_
� n
0
g� 0 0 a o 0 O'C)
£'
691 b 1 116V
a
oe0�Q0Q0�90�g0?Q0�Q0�g0�050?q0?y0�Q0�00¢0t000Q0�Q0�0
��
VV.O WOD ODW OD ODA O'OD CD OD•A AODA OD A00 ODA
N
�
x�
V
00-+W�WWWWN �A .,A�. A�JN�NOJN AAN
0
0
0ffi0o00con4z '00oo000000000
��
fDx
PD
o
� x
e
orn0000000�00000o0000000
..
x C>m
�O (J000000 000.000000000(3
�
�
��
fh WW00
00
O-�
OD
OOOOO OAOOV 0000000000000
0
0
orna00000000000000o00000
B
o
N
C
o
O N o o 0 0 0 0 0 0 0 0 0 o T 0 0 0 0 0 0 0 O
X c z
=
S
W
O�
00
00&00
y
W
N
CD
N
O
CC7npp��
as 000 COO co (Doe,c's OOO 000.00
v
�
O O
O O V O O
V
o 0
O 0)A
O
O o 0 0 0 0 0 0 0 0 0 00 0i 0 0 0 0 0 0 0 O
■G',7
Cf