Loading...
HomeMy WebLinkAboutCERTTIFICATION FOR DESIGN LOAD CALCULATIONSBY 77, Planning & Development Services Department 0 Building & Code Regulations, Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: RESIDENCE FOR SHORELINE RV Project Address: LOT 783 NETTLES BLVD Permit #: INSTRUCTIONS FOR USE: Occupancy Type: I R Construction Type: V • This certification must be completed, signed, and sealed bpi the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building o Any non-residential structure. * Note: Form not required for interior renovations provided hat no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. 1. DESIGN CODE: Florida Building Code 2010 Edition with 2010 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _ Partially Enclosed Open 3. Risk Category: _ I X II III IV Exposure Category: _ B C X D 4. Design Wind Velocity 165 mph 128 ASD N/A LRFD End Zone Width: 5 It S. Mean Roof Height: 15 ft Roof Pitch: 6 :12 I Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, bas 28.1 28.1 28.1 Zone 1: -44.7 Zone 2: -77.7 Zone 3: _115.0 Zone 7. Design Loads: Floor: 40 PSF Roof/Dead: 7 F Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF F 8. Were Shear Walls Considered For Structure? _X_Yes on 10sgft @ 15'MRH, clearly label on all plan openings): 48.8 Zone 5: 48.8 Garage: N/A -52.9 -65.3 N/A Roof/Live: 20 Balcony:. N/A PSF ce: N/A PSF Railings: N/A PLF / CONCENTRATED of Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: 4/25/2014 Signatu6,Date, and Seal SUX:UV Form # UZU-12 Kevised 3/15/12 (JS) Paul Welch P.E. 29945 / 5115 Print Name Cert # & Co. Cert Auth. Paul Welch Inc. 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL Company Name & Address