HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM'46510 [DI
FLORIDA ENERGY EFFICIENCY Oea ftW/BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: LOT 783 NETTLES ISLAND BLVD
Builder Name:
Street: LOT 783 NETTLES ISLAND BLVD.
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (1350.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0 1350.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1143.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1143.00 ft2
6. Conditioned floor area above grade (ft2) 1143
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(163.0 sgft.) Description Area
a. Sup: RoomslnBlock1, Ret: RoomslnBlock1, AH: 6 228.6
a. U-Factor: Sgl, U=0.29 163.00 ft2
SHGC: SHGC=0.29
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
28.0 SEER:14.00
c. U-Factor: N/A j ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A I ft2
a. Electric Strip Heat
28.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 1.184 ft.
Area Weighted Average SHGC: 0.290
14. Hot water systems
a. Electric Tankless
Cap: 1 gallons
8. Floor Types (1143.0 sgft.) Insulation Area
EF: 0.990
a. Slab -On -Grade Edge Insulation R=0.0 1143.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= I ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.143. Total Proposed Modified Loads: 22.37
PASS
Total Standard Reference Loads: 29.55
hereby KnLcovTreVdy
STAT
I certify that the plans and specifi cati
Review of the plans and
AZT
this calculation are in compliance with the Florida Energy
specifications covered by this
�y�
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Qt`yr�&'fi4C Chni1GY 64%s
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
t
# �`
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
CIO 161
OWNER/AGENT: -'E`"''�' �` �-
BUILDING OFFICIAL:
DATE: Lt - z 1 ' t `t
DATE:
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
3/21/2014 8:16 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGi PERFORMANCE INDEX* = 76
The lower the EnergyPerformance Index, the more efficient the home.
LOT 783 N
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows** Description
a. U-Factor: Sgl, U=0.29
SHGC: SHGC=0.29
b. U-Factor: N/A
SHGC:
c. U-Factor: N/A
SHGC:
d. U-Factor: NIA
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
New (From Plans)
Single-family
1
2
No
1143
Area
163.00 ft2
ft2l
Insulation
R=0.0
R=
R=
ft2l
I
ft2
1.184 ft.
0.290
Area
1143.00 W
ft?
ft2
I
ISLAND BLVD., FT. PIERCE, FL,
9. Wall Types
Insulation
Area
a. Concrete Block - Int Insul, Exterior
R=5.0
1350.00 ft2
b. N/A
R=
ft2
c. N/A
R=
ft2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0'
1143.00 ft2
b. N/A
R=
ft2
c. N/A
R=
ft2
11. Ducts
R ft2
a. Sup: RoomslnBlockl, Ret: RoomslnBlockl, AH:
6 228.6
12. Cooling systems
kBtu/hr
Efficiency
a. Central Unit
28.0 SEER:14.00
13. Heating systems
kBtu/hr
Efficiency
a. Electric Strip Heat
28.0
COP:1.00
14. Hot water systems
Cap: 1 gallons
a. Electric
EF: 0.91
b. Conservation features
None
15. Credits CF, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: �,,.,�„�( -(7-- }k�� I Date: y Z V_,y
Address of New Home: 7 9- 3 !mot �f (�5 vej City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
E
PROJECT
i
Title:
LOT 783 NETTLES ISLAND Bedrooms:; 2
Address Type:
Street Address
Building Type:
FLProp2010
Conditioned Area: 1143
Lot #
Owner:
Total Stories: 1
Block/SubDivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
LOT 783 NETTLES ISL
Permit Office:
ST. LUCIE COUNTY
Cross;Ventilation:
County:
ST. LUCIE
Jurisdiction:
Whole House Fan:
City, State, Zip:
FT. PIERCE,
Family Type:
Single-family
/
FL,
New/Existing:
New (From Plans)
Comment:
/
/ CLIMATE
/
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
v Design Location
TMY Site i Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture Range
FL, Fort Pierce FL—ST—LUCIE CO — INTL 2 39 90
70
75 722
62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1143 10287
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
RoomslnBlock1
/1143 10287 Yes 2
2
1 Yes
Yes Yes
/ FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge In s/latio RoomslnBlockl 143 ft 0
1143 ft2
0 0 1
/
ROOF
/
Roof Gable Roof
Solar
SA Emitt
Emitt Deck Pitch
�/ #
Type
Materials Area Area Color
Absor.
Tested
Tested Insul. (deg)
1
Hip / Composition shingles 1238 ft2 0 ft2 Medium
0.96
No 0.9
No 0 22.6
/
ATTIC
V
/
#
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 1143 ft2
N N
/
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac
Truss Type
1
Under Attic (Vented)
RoomslnBlockl 30 1143 ft2
0.11
Wood
3/21/2014/8:16 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
i �
WALLS
-
V
Adjacent
Cavity Width
Space
Height Sheathing Framing Solar
Below
it Omt
TO I
Type t3-Value Ft In Ft
In Area R-Afallie
Fraction A
1 N
Exterior Concrete Block - Int Ins5IoomsInBIoc 5 48 9
432 ft2
0 0.75
0
2 S
Exterior Concrete Block - Int InS5l00mslnBlac 5 66 9
594 ft2
0 0.75
0
3 E
Exterior Concrete
Block - Int InSEdoomslnBIoc 5 14 9
126 ft2
0 0.75
0
4 W
Exterior Concrete Block - Int Ins6loomsinBloc 5 22 9
198 ft2
0 0.75
0
(DOORS
#
Omt
Door Type Space Storms
U-Value Width
Height
Area
Ft In
Ft' In
1
E
Wood RoomslnBloc I None
0.460000 3
7
21 ftz
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Ir
Overhang
#
Ornt ID Frame
Panes NFRC U-FactoSHGC Storms
Area Depth Separation
Int Shade
Screening
1
W 4 Metal
Single (Tinted) Yes 0.29 0.29 N
9 ft' 1 ft 0 in 0 ft 0 in
HERS 2006
None
2
N 1 Metal
Single (Tinted) Yes 0.29 0.29 N
10 ft' 1 ft 0 in 0 ft 0 in
HERS 2006
None
3
S 2 Metal
Single (Tinted) Yes 0.29 0.29 N
15 ft2 1 ft 0 in 0 ft 0 in
HERS 2006
None
4
S 2 Metal
Single (Tinted) Yes 0.29 0.29 N
81 ft' 1 It 0 in 0 ft 0 in
HERS 2006
None.
5
S 2 Metal
Single (Tinted) Yes 0.29 0.29 N
18 ft2 1 ft 0' in 0 ft 0 in
HERS 2006
None
6
E 3 Metal
Single (Tinted) Yes 0.29 0.29 N
6 ft2 6 ft 0 in 0 ft 0 in
HERS 2006
None
7
W 4 Metal
Single (Tinted) Yes 0.29 0.29 N
15 ft2 1 ft 0 in 0 ft 0 in
HERS 2006
None
8
W 4 Metal
Single (Tinted) Yes 0.29 0.29 N
9 ft2 1 ft 0 in 0 It 0 in
HERS 2006
None
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA ACH ACH 50
i
1 BySpaces Proposed SLA 0.000360 1079.3 59.253 111.43 0.2628 6.2952
HEATING SYSTEM
#
System Type
Subtype I Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat None COP: 1
28 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit
None SEER: 14
28 kBtu/hr 840 cfm
0.75 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType Location EF Cap,
Use SetPnt
Conservation
1
Electric
Tankless RoomslnBlocI0I9108 1 gal, 50 gal 120 deg
None
3/21/2014 8:16 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model #
Collector Model
# Area
Volume
FEF
None
None
ft2
DUCTS
— Supply
—
— Return --
Air
Percent
HVAC #
# Location R-Value Area
Location Area Leakage Type
Handler
CFM 25
Leakage
QN RLF
Heat Cool
1 RoomslnBloc 6
228.6 ft
RoomslnBloc 57.15 ft DSE=0.88
RoomslnBl 0.0 cfm
0.00 %
0.00
0.60
1 1
TEMPERATURES
i
Programable Y
Ceiling Fans: I
an
Heating X] Jan
f X� Feb
f X1 Mar
Ri Apr rxxi May Apr May KIJun
Jul
RXI
Aug
rxxi
rx� Sep
RjOct
Nov
Nov
Dec
XX DecVenting
[X Jan
[X Feb
[X MarJun
Jul
Aug
Sep
X�
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3 4 5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78 78 '78
78
78
78
80
80
80
80
PM
80
80
78 78 8
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78 78 8
78
78
78
78
78
78
78
PM
78
78
78 78 7�8
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66 66 66
68
68
68
68
68
68
68
PM
68
68
68 68 68
68
68
68
68
68
66
66
Heating (WEH)
PM
68
68
68 68
ft
68
68
68
68
68
66
66
3/21/2014 8:16 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
FORM' 405A 0
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: LOT 783 NETTLES ISLAND BLVD. PERMIT #:
FT. PIERCE, FL,
MANDATORY REQUIREMENTS SUMMARY - See indivl dual code sections for full details.
COMPONENT
SECTION
SUMMARY �IOF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC 1rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft_ Testing or visual inspection required. Fireplaces:
gasketed doors& outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where I �forced-air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
l
403.3.3
i
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate'at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce�.heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
.minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
3/21/2014 8:16 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5