HomeMy WebLinkAboutCORRECTION LISTUti/l U CORRECTION LIST Code No. I DESCRIPTION Section -2- \ i NOTE: Entries to this Plan Review Record that require a field check or Inspection of the Installation must be coordinated with the Inspection phase (R109) of the project. BUILDING PLANNING (Chapter 3) DESIGN CRITERIA [Table R301.2(1)j W Two-family dwelling separation (R302.3) Floor live load (Table R301.5) psf Dwelling unit penetrations (R302.4) Roof live load (Table R301.6) 1 psf Dwelling/garage opening/penetration protec- Ground snow load VYTpsf tion (R302.5) Basic wind speed mph Wind exposure category (R301.2.1.4) Dwelling/garage fire separation (R302.6) High wind design criteria applicable'/ Under -stair protection (R302.7) (R301.2.1.1) 1/ Wall and ceiling finishes (R302.9) Seismic design category (SDC) [Figure R301.2(2)] SDC C&D provisions (R301.2.2) Weathering Frost line depth Termite area Decay area i Winter design temperature Ice barrier underlayment required Flood hazards FIRE-RESI TANT CONSTRUCTION (R302) Exterior walls (R302.1, Table R302.1) Townhouse separation (R302.2) Continuity and structural independence I(R302.2.1, R302.2.4) Parapets and construction (R302.2.2, R302.2.3) ROOM PLANNING REQUIREMENTS (R303 through R305) _Flame spread index (R302.9.1) �Smoke-developed index /Testing (R302.9.2) (R302.9.3, R302.9.4) 1/ Insulation (R302.10) d/ Flame spread/smoke-developed / (R302.10.1, R302.10.2) y Cellulose loose -fill and exposed attic insulation (R302.10.3, R302.10.4) Testing (R302.10.5) ireblocking (R302.11) raftstopping (R302.12) �!/ Combustible insulation clearance (R302.13) Use Area ft2 Width ,Average ceilin t Minimum ceilincit Natural* light Natural ventilation* Living 120 7'-0" 7'-0" 5'=0" 8% floor area 4% floor area Dining 70 7'-0" T-0" 5'-0" 8% floor area 4% floor area Kitchen N.A. N.A. 7'-0" 5'-0" 8% floor area 40)o floor area Bedroom 70 7'-0" T-0" T-0" 8% floor area 4% floor area Bathroom N.A. N.A 7'-0" 5'-0" 3 square feet 11/2 square feet See Sections R303.1 & R303.3 for mechanical ventilation and artificial light t 6'-8" min. at plumbing fixtures and for non -habitable basements. Required heating (R303.8) SANITATION (R306 and R307) Water closet Lavatory Tub or shower Kitchen area with sink Sanitary sewer (Chapter 30) Private disposal (Appendix 1) GLAZING ( 08) Wj/�-Identification (R308.1) /oLouvered windows or jalousies (R308.2) !/ Human impact loads/hazardous locations (R308.3, R308.4) Skylights and sloped glazing (R308.6) -3- BUILDING PLANNING (cont'd.) GARAGES AND CARPORTS (R309) Floor surface noncombustible; sloped floor (R309.1) Carport: open two sides; noncombustible floors; sloped floor (R309.2) Automatic garage door opener (R309.4) EMERGENCY ESCAPE AND RESCUE OPENINGS (R310) =��Areas, here required (R310.1) I height, width, operations (R310.1.1 - R310.1.4) Window wells (R310.2) Bars, grilles, covers and screens (R310.4) Under decks and porches (R310.5) MEANS OF EGRESS (R311) eneral (R311.1) y Egress door (R311.2) V11" Landings at exterior doors (R3,11.3 - R311.3.3) ��Vertical egress (R311.4) W, � Construction and attachment (R311.5) allways (R311.6) V Stairway width, headroom, walkline (R311.7.1 R311.7.3) '� Stairway treads, risers profiles (R311.7.4 - / R311.7.4.3) v airway landings and walking surfaces (R311.7.5, R311.7.6) Handrails required (R311.7.7) t7'*- Handrail height, continuity, grip -size (R311.7.7.1 - R311.7.7.3) Stairway illumination (R303.6, R311.7.8) Special stairways (R311.7.9) Ramp slope, landings, handrails (R311.8) GUAR"P,312) Required for open -sided surfaces, stairs,' ramps and landings > 30" above floor/grade (R312.1) ::� Height - 36 (R312.2) Opening limitations (R312.3) AUTOMATIC FIRE SPRINKLER SYSTEMS (R313) AN- Townhouses (R313.1) _- One- and two-family dwellings'(R313.2) SMOKE ALARMS (R314) _ Referenced standards (R314.1, R314.2) 1/ Location and interconnection (R314.3) Power source (R314.4) CARBON ,f 4ONOXIDE.ALARMS (R315) New construction (R315.1) < Existing construction (R315.2) Referenced standard (R315.3) FOAM P STIC (R302.8, R316) Labeling (R316.2) Surface burning, thermal barrier, specific approval (R316.3 - R316.7) DECAY AND TERMITE PROTECTION (R317/and R318) f/ Protection required (Table R301.2(1), R317.1, / R318.1) Quality mark (R317.2 and R318.1.1) SITE ADDRESS (R319) _Address numbers (R319.1) ACCESSIBILITY (R320) y Type B dwelling units applicable (R320.1) ELEVATORS/PLATFORM LIFTS (R321) A- Referenced standards (R321.1 - R321.3) FLOOD -RESISTANT CONSTRUCTION (R322) L, General (R322.1) azard area and requirements (R301.2.4, R309.3, R322.2, R322.3) Design professional (R322.3.6) STOF��VI SHELTERS (R323) General and referenced standard (R323.1) -4- MATERIALS (R402) Wood foundations (R402.1) Concrete, compressive strength (R402.2) i FOOTINGS (R403) Soil bearing value (R401.4; R403.1) Footing width (see page 5)I' Footing edge thickness = &' minimum; footing projection = 2" minimum, but <_ footing thickness (R403.1.1) Footings in SDC C or D (R403.1.2, R403.1.3 and R403.1.6.1) /Depth below (outside) grade = 12" minimum; but below frost line except for frost pro- tected footings.(R403.1.4, R403.1.4.1 and R403.1.4.2) (i/ /► Sill plate bolting in concrete/masonry ='/Z" di- ameter bolts, within 12" but not less than 7 bolt diameters from corner, 7" embedment (R403.1.6) Footings adjacent to slopes (R403.1.7) Frost protected shallow foundations (R403.3) Footings for precast concrete foundation (R403.4) FOUNDAT IN WALLS (R404 - R406) 7Masonry foundation walls (R404.1.1) _ Wall height, unbalanced backfill, nominal thickness (Tables R404.1.1(1) - R404.1.1(4), R404.1.5.11 Reinforcement size and spacing (Tables R404.1.1(2) - R404.1.1(4)] Con FOUNDATIONS (Chapter 4) aCo foundation walls (R404.1.2) Wall height, unbalanced backfill, nominal thickness ITables R404.1.2(2) - R404.1.2(8), R404.1.5.21 Horizontal and vertical reinforcement size and spacing (Tables R404.1.2(1) - R404.1.2(8), R404.1.2.2, R404.1.2.3.71 Stay -in -place forms (R404.1.2.3.6.1) SDC C and D provisions. (R404.1.2.4, R404.1.4) Height above finished grade (R404.1.6) Sill plate size (R404.3) Precast concrete foundation walls (R404.5) Drains required if habitable or usable spaces are below grade* (R405) Soil class (Table R405.1) Dampproofing if basements are below grade* (R406.1) Waterproofing if high water table* (R406.2) * If uninhabitable, see Under -Floor Space (R408) COLUMNS (R407) Protection from decay or corrosion (R407.1 and R407.2) Structural requirements (R407.3) All 6 Anchorage (R407.3) Wood columns (minimum 4" square) (R407.3) Steel columns minimum 3" diameter, Sched- ule 40 pipe) (R407.3) TABLE R403.1 eelNlMUM WIDTH OF CONCRETE. PRECAST OR MASONRY FOOTINGS (inc esla LOAD -BEARING VALUE OF SOIL 1,500 2,000 3,000 > 4\000 Conventional li ht-frame construction 1-sto 12 12 12 12 2-story15 12 12 12 3-sto 23 17 12 12 ; 4-inch brick veneer over II ht frame or 8-inch hollow concrete masonry 1-sto 12 12 12 12 2-story21 16 12 12 3-story32 24 16 12 8-Inch solid or full routed masonry 1-sto 16 12 12 12 2-story29 21 14 12 3-story42 32 21 16 For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa a. Where minimum footing width is 12 inches, a single wythe of solid or fully grouted 12—inch nominal concrete masonry units is permitted. -5- For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa a. Where minimum footing width is 12 inches, a single wythe of solid or fully grouted 12—inch nominal concrete masonry units is permitted. -5- FOUNDATIONS (cont'd.) UNDER -FLOOR SPACE (R408) Ventilation (R408.1 and R408.2) Unvented crawl space (R408.3) Access (R408.4) FLOORS (Chapter 5) i WOOD J ISTS AND GIRDERS (R502) Species and grade (R502.1). L/ Joists — Sleeping areas, LLI;= 30 psf [Table R502.3.1(1)] Joists — Nonsleeping areas,, LL = 40 psf //] [Table R502.3.1(2)] /V %( 1, Cantilevered joists [Tables RI502.3.3(1) and R502.3.3(2)] Girder spans and header spans for exterior /bearing walls [Table R502.5(1)] V_ Girder spans and header spans for interior bearing walls [Table R502.5(2)] /� .'�� 1 Joists under bearing partitions,(R502.4) Bearing (1.5" minimum on wood or metal; 3" on masonry or concrete) and lapped joists (3") (R502.6, R502.6.1) Lateral restraint and bridging IR502.7, R502.7.1) Drilling and notching (R502.8) . /Fastening (R502.9) V Framing of openings (R502.10) d trusses (R502.11) :1�?Drao ftstopping (R502.12) LUMBERFLOORSHEATHING (R503.1) i/�Il'owable span (Table R503.1) i/ End joints (R503.1.1) WOOD STRUCTURAL PANEL SHEATHING (R503.2) ST Grade (R503.2.1) Thickness (R503.2.1) Allowable spans [Tables R503.2.1.1(1) and R503.2.1.1(2)] Installation [Table 602.3(1)] Removal of debris (R408.5) Finished grade (R408.6) Flood resistance (R408.7) PARTICLEBOARD UNDERLAYMENT (R503.3) Grade (R503.3.1) Thickness (R503.3.2) Installation [Table R602.3(1)] THE TED-WOOD FLOORS (ON GROUND) (R504) Base course: 4" thick with maximum 1/4, gravel or'/2" crushed stone (R504.2.1) i i Moisture barrier: placed over base course (R504.2.2) Materials (R504.3) STE L FLOOR FRAMING (R505) Cold -formed steel; applicability limits; in -line framing (R505.1) Structural framing (R505.2) Material (R505.2.1) Identification (R505.2.2) Corrosion protection (R505.2.3) Fastening (R505.2.4) Floor construction (R505.3) CONCRETE FLOORS (ON GROUND) (R506) 1zhickness: 31/2" minimum; Concrete strength (R506.1) _Support: prepared subgrade; maximum earth fill = 8"; maximum sand or gravel fill = 24" R506.2.1) e course: 4" graded with 2" maximum Base (R506.2.2) , Vapor retarder (R506.2.3) ✓/ Reinforcement support (R506.2.4) N WALL CONSTRUCTION (Chapter 6) GENERAL R601) ___,Design (R601.2) �/ Component and cladding wind loads [Table R301.2(2)] Vapor retarders (R601.3) WOOD CO STRUCTION (R602) Construction (Figures R60Z3(1) and / R602.3(2)] "' Stud grade (R602.2) Exterior walls (R602.3) Stud spacing [R602.3.1, Table R602.3(5)] t/ Interior load -bearing walls (R602.4) Interior nonbearing walls: 2" x 3" at 24" o.c. or 2" x 4" flat at 16" o.c. (R602.5) i �nlling and notching — studs (R602.6) rilling and notching —top plate (R602.6.1) Headers (Tables R502.5(1), R502.5(2), 2602.7.2 and Figure R602.7.21 F//Fireblocking (R602.8, R302.11) Cripple walls (R602.9) Wall bracing, braced wall lines, lengths, connections, support and joints (R602.10, R602.10.1, R602.10.3, R602.10.6 - R602.10.8) Bracing based on wind speed [Table R602. 1Q. 1.2(l)] Bracing based on SDC [Table R602.10.1.2(2)] Intermittent bracing methods (R602.10.2, Table R602.10.2) Continuous sheathing (R602.10.4, R602.10.5) Bracing for SDC C and D (R602.10.1.4.1, R602.10.1.5, R602.11) Wall bracing for stone and masonry veneer (R602.12) STEEL WALL FRAMING (R603) General (R603.1) _ Structural framing (R603.2) Material (R603.2.1) Identification (R603.2.2) Corrosion protection (R603.2.3) Fastening (R603.2.4) Wall construction (R603.3 - R603.5) Headers (R603.6) Studs, tracks and structural sheathing (R603.7 - R603.9) SHEATHING (R604 and R605) Wood structural panels (R604) _ Particleboard (R605) MASONRY CONSTRUCTION (R606 - R610) General design (R606) �_ SDC C and D (R606.12) �' Unit masonry (R607) MMultiple wythe masonry (R608) Grouted masonry (R609) Glass unit masonry (R610) EXTERIOR CONCRETE WALL CONSTRUCTION (R611) e(I'Applicability (R611.2) Concrete wall systems (R611.3) Stay -in -place forms (R611.4) Materials, construction details (R611.5 - R611.10) EXT7General; WINDOWS & DOORS (R612) window sills; performance; testing and labeling (P612) STRUCTURAL INSULATED PANEL WALL CONSTRUCTION (R613) Applicability (R613.2) Materials (R613.3) Wall panels, construction details JR613.4 - R613.10) -7- WALL COVERING (Chapter 7) INTERIOR WALL COVERING (R702) -- Plaster material (R702.2) Plaster support (R702.2.3) Gypsum board material (R702.3.1) Gypsum on, support, application and / fastening (R702.3.2 - R702.3.8) eramic the (R702.4) � Other finishes (R702.5 and'R702.6) EXTERI0�2 WALL COVERING (R703) Water -resistive barrier (R703.2) Wood siding (R703.3) Attachment and minimum thickness (Table R703.4) Wood shakes and shingles (R703.5) �erlor plaster (R703.6) Stone & masonry veneer (R703.7 & Figure R703.7); Steel angle lintels-4" minimum r bearing each end (R703.7.3) Il Veneer ties: #9 U.S. gage wire or #22 U.S. gage by'/e"corrugated metal; 24" o.c. maximum horizontal spacing; 2.67 square feet maximum area supported (wind > 30 psf and SDC C or D, maximum area = 2 square feet) (R703.7.4.1) Flashing (R703.7.5 and R703.8) Exterior insulation and finish systems (R703.9) Fiber cement siding (R703.10) Vinyl siding (R703.11) ROOF -CEILING CONSTRUCTION (Chapter 8) GENERALL (R801) y Design (R801.2 and R801.3) _L�Component and cladding wind loads.[Tab/e R301.2(2)] ROOF FRAIy11NG (R802) ,Fire -retardant -treated wood (R802.1.3) Framing details (R802.3) i�- Rafter tie (R802.3.1) Collar ties (4' o.c., in upper third of attic) (R802.3.1) Purlins (2" x 4" at 4' o.c. minimum) / (Figure R802.5.1, R802.5.1) v Bearing (R802.6) o� ttting and notching (R802.7) gineered wood products (R802.7.2) ;eral support and bridging (R802.8) aming of openings (R802.9) �=ooftie-down d trusses (R802.10) (R802.11) CEILING�JOISTS [Tables R802.4(1), R802.4(2)] �// Without attic storage, LL = 10psf With attic storage LL = 20psf Spacing —�. species Grade Span �ize RA�S (fables R802.5.1(1) - R802.5.1(8)] Ground snow load/LL = 20psf Controlling design (LL or snow) Ceiling not attached/ceiling attached Spacing Species Grade Span Size Hc/HR; Adjustment factor ROOF SFjEATHING (R803.2) ROOF ,,'thickness �FRTW allowable stresses/grading ::5::Allowable spans (fable R503.2.1.1(1)) Installation (R803.2.3) CHIMNEYS AND FIREPLACES (cont'd.) Changes in dimension (R1003.6) Chimney clearance (R1003.18) Additional load (R1003.8) Fireblocking (R1003.19) Termination (R1003.9) Chimney crickets (R1003.20 Spark arrestors (RI 003.9.1) FACTORY -BUILT FIRER S (R1004) Wall thickness; >_ 4" (R1003.10) ' ed and labeled (R1004.1) Flue lining - material/installation (R1003.11 Installation (R1004.2) and R 1003.12) FACTORY -BUILT CHIMNEYS (R1005) Multiple flues (R1003.13) Listed and labeled (R1005.1) Flue area (appliance) (R1 .14) Installation (R1005.3 and R1005.4) Flue area (maso fireplace) (R1003.15) Inlet (R1 .16) EXTERIOR AIR SUPPLY (131006) anout opening (R1003.17) Intake size (R1006.2, R1006.4) ENERGY EFFICIENCY* (Chapter 11) Compliance; material and equipment B 'Iding envelope (N1102) (N1101.2, N1101.3) Mechanical systems (N1103) Climate zone (Table N1101.2) 'See energy conservation plan review record MECHANICAL (Chapters 12-23) Appliance labeling (M130Z M1303) Chimney and vent location and terminations Appliance access (M1305, M1401) Appliance installation (M1307) Heating and cooling equipment; heating and cooling load calculations (Chapter 14) Exhaust systems (Chapter 15) Duct systems (Chapter 16) Combustion air (Chapter 17) (Chapter 10 and Chapter 18) Special fuel -burning equipment (Chapter 19) Boilers/water heaters (Chapter 20) Hydronic piping (Chapter 21) Special piping and storage systems (Chapter 22) Solar systems (Chapter 23) Penetrations of fire -resistance rated assem- blies (R302.4, R302.5) FU L G S (Chapter 24) Application (G2401.1) Cle General regulations (G2404) Electrical and electrical bonding (G2410, G2411) Appliance locatio 6) Pipe sizing (G2413) urements (G2407) Piping materials (G2414) Installation (G2408) -10- FUEL S (cont'd) Piping installation G2415 and G2419) P 9 ( Piping support (G2418 and G2424) L Valves, co c ions (G2420, G2421 Misc appliances (G2423, G2425, G2430 - G2453) PLUMBING (Chapters 25-33) Water service location and depth (P2603, Sprinkler coverage P2604) (P2904.2.4) Sanitary and storm sewer location and depth Piping materials (P2904.3) (P2603, P2604) Flow rates (P2904.4.1, Piping support (Table 152605.1) P2904.4.2) Listed plastic materials (P2608) Water supply capacity (P2904.5.2) Plumbing fixtures (Chapter 27) Water heater size and location (Chapter 28) Pipe sizing (P2904.6) Water supply and distribution system design Drain, waste and vent pipe sizing and riser diagram (P3004, P3005, Chapter 31) and calculations (Chapter 29) Dwelling unit fire sprinkler systems (P2904) Sumps and ejectors (P3007) Backwater valves (P3008) NFPA 13D system (P2904.1) Fixture traps (P3201) Temperature rating (P2904.2.1, P2904.2.2) Storm drainage (Chapter 33) Freezing protection Penetrations of fire -resistance rated assem- (P2904.2.3) blies (R302.4, R302.5) ELECTRICAL (Chapters 34-43) Penetrations of fire -resistance rated assem- Wiring methods (Chapter 38) blies (E3402.2) Required lighting and receptacle outlets Listed and labeled materials (E3403) (E3901, E3903) Service equipment and location (E3405, Ground -fault and arc -fault circuit -interrupter E3601, E3606) protection (E3902) Service size and load calculations (E3602) Devices and lighting fixtures (Chapter 40) Available fault current'(E3606) Appliance installation (Chapter 41) System grounding (E3607) Swimming pools (Chapter 42) Required branch circuits (E3703) Class 2 remote -control, signaling and power -lim- ited circuits (Chapter 43) Feeder requirements and load calculations (E3704) MANUFACTURED HOUSING USED AS DWELLINGS (Appendix E) Provisions adopted (R102.5) ompliance with Appendix E verified -11- RADON CONTROL MEASURES (Appendix F) Provisions adopted (R102.5) tl Compliance with Appendix F verified SWIMMING POOLS, SPAS AND HOT TUBS (Appendix G) Compliance with Provisions adopted (R102.5) P Appendix G verified PATIO CO ERS (Appendix H) Provisions adopted ( (" / ' Compliance with Appendix H verified R102.5 ) PRIVATE SEWAGE DISPOSAL (Appendix 1) Provisions ( ) R102.5 adopted Compliance with Appendix I verified P . EXISTING BUILDINGS AND STRUCTURES (Appendix J) Provisions adopted (R102.5) Compliance with Appendix J verified SOUND TRAN MISSION (Appendix K) Provisions adopted (R102.5) Compliance with Appendix K verified HOME DAY CARE— -3 OCCUPANCY (Appendix M) Provisions adopted (R102.5) Compliance with Appendix M verified -12- Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462-6443 ,I RI 9 a9P.10"R t FLOOD HAZARD NOTICE PERMIT NUMBER: 1303-0067 3/8/2013 LOCATION: 63 NETTLES BLVD JENSEN BEACH L E, -00- 0 Py CONTRACTOR: JAMES W NEWMAN i DBA: JWN CONSTRUCTION INC OWNER: Wayne D Thomas NOTICE This Notice is to inform you that your property is in a Flood Hazard Zone. This means that the elevation for the first floor must be set at 6 feet, NAVD (mean sea level), or 18" above the crown of the road whichever is'greater. NO CONSTRUCTION is to proceed beyond the 1st floor/slab inspection, orjust prior to the second floor pour of a multi -story structure, until the required elevation certification has been completed by a registered surveyor, and received and approved by the Building Division of the St. Lucie County Community Development Department. Violation of the requirement will result in the scheduling of a public hearing before the St. Lucie County Code Enforcement Board. The Board is empowered to levy a fine not to exceed $250.00 per day for each day the violation continues. A fine not to exceed $500.000 per day may be levied for a repeat violation. The fine may become a lien upon the real or personal property of the violator. The elevation certification may be submitted any time within 21 calendar days from the above; however, no further construction should take place, nor will any inspections be made until the required certification has been received and approved. c Signature Date