CORRECTION LIST
Code
No. I DESCRIPTION Section
-2-
\ i
NOTE: Entries to this Plan Review Record that require a field check or Inspection of the Installation must be coordinated with the Inspection phase (R109) of the project.
BUILDING PLANNING (Chapter 3)
DESIGN CRITERIA [Table R301.2(1)j W Two-family dwelling separation (R302.3)
Floor live load (Table R301.5) psf Dwelling unit penetrations (R302.4)
Roof live load (Table R301.6) 1 psf
Dwelling/garage opening/penetration protec-
Ground snow load VYTpsf tion (R302.5)
Basic wind speed mph
Wind exposure category (R301.2.1.4) Dwelling/garage fire separation (R302.6)
High wind design criteria applicable'/ Under -stair protection (R302.7)
(R301.2.1.1) 1/ Wall and ceiling finishes (R302.9)
Seismic design category (SDC)
[Figure R301.2(2)]
SDC C&D provisions (R301.2.2)
Weathering
Frost line depth
Termite area
Decay area i
Winter design temperature
Ice barrier underlayment required
Flood hazards
FIRE-RESI TANT CONSTRUCTION (R302)
Exterior walls (R302.1, Table R302.1)
Townhouse separation (R302.2)
Continuity and structural
independence I(R302.2.1,
R302.2.4)
Parapets and construction
(R302.2.2, R302.2.3)
ROOM PLANNING REQUIREMENTS (R303 through R305)
_Flame spread index (R302.9.1)
�Smoke-developed index
/Testing
(R302.9.2)
(R302.9.3, R302.9.4)
1/ Insulation (R302.10)
d/ Flame spread/smoke-developed
/ (R302.10.1, R302.10.2)
y Cellulose loose -fill and exposed
attic insulation (R302.10.3,
R302.10.4)
Testing (R302.10.5)
ireblocking (R302.11)
raftstopping (R302.12)
�!/ Combustible insulation clearance (R302.13)
Use
Area
ft2
Width
,Average
ceilin t
Minimum
ceilincit
Natural*
light
Natural ventilation*
Living
120
7'-0"
7'-0"
5'=0"
8% floor area
4% floor area
Dining
70
7'-0"
T-0"
5'-0"
8% floor area
4% floor area
Kitchen
N.A.
N.A.
7'-0"
5'-0"
8% floor area
40)o floor area
Bedroom
70
7'-0"
T-0"
T-0"
8% floor area
4% floor area
Bathroom
N.A.
N.A
7'-0"
5'-0"
3 square feet
11/2 square feet
See Sections R303.1 & R303.3 for mechanical ventilation and artificial light
t 6'-8" min. at plumbing fixtures and for non -habitable basements.
Required heating (R303.8)
SANITATION (R306 and R307)
Water closet
Lavatory
Tub or shower
Kitchen area with sink
Sanitary sewer (Chapter 30)
Private disposal (Appendix 1)
GLAZING ( 08)
Wj/�-Identification (R308.1)
/oLouvered windows or jalousies (R308.2)
!/ Human impact loads/hazardous locations
(R308.3, R308.4)
Skylights and sloped glazing (R308.6)
-3-
BUILDING PLANNING (cont'd.)
GARAGES AND CARPORTS (R309)
Floor surface noncombustible; sloped floor
(R309.1)
Carport: open two sides; noncombustible
floors; sloped floor (R309.2)
Automatic garage door opener (R309.4)
EMERGENCY ESCAPE AND RESCUE OPENINGS
(R310)
=��Areas,
here required (R310.1) I
height, width, operations (R310.1.1 -
R310.1.4)
Window wells (R310.2)
Bars, grilles, covers and screens (R310.4)
Under decks and porches (R310.5)
MEANS OF EGRESS (R311)
eneral (R311.1)
y Egress door (R311.2)
V11" Landings at exterior doors (R3,11.3 -
R311.3.3)
��Vertical egress (R311.4)
W, � Construction and attachment (R311.5)
allways (R311.6)
V Stairway width, headroom, walkline (R311.7.1
R311.7.3)
'� Stairway treads, risers profiles (R311.7.4 -
/ R311.7.4.3)
v airway landings and walking surfaces
(R311.7.5, R311.7.6)
Handrails required (R311.7.7)
t7'*-
Handrail height, continuity, grip -size
(R311.7.7.1 - R311.7.7.3)
Stairway illumination (R303.6, R311.7.8)
Special stairways (R311.7.9)
Ramp slope, landings, handrails (R311.8)
GUAR"P,312)
Required for open -sided surfaces, stairs,'
ramps and landings > 30" above
floor/grade (R312.1)
::�
Height - 36 (R312.2)
Opening limitations (R312.3)
AUTOMATIC FIRE SPRINKLER SYSTEMS (R313)
AN- Townhouses (R313.1)
_- One- and two-family dwellings'(R313.2)
SMOKE ALARMS (R314)
_ Referenced standards (R314.1, R314.2)
1/ Location and interconnection (R314.3)
Power source (R314.4)
CARBON ,f 4ONOXIDE.ALARMS (R315)
New construction (R315.1)
< Existing construction (R315.2)
Referenced standard (R315.3)
FOAM P STIC (R302.8, R316)
Labeling (R316.2)
Surface burning, thermal barrier, specific
approval (R316.3 - R316.7)
DECAY AND TERMITE PROTECTION
(R317/and R318)
f/ Protection required (Table R301.2(1), R317.1,
/ R318.1)
Quality mark (R317.2 and R318.1.1)
SITE ADDRESS (R319)
_Address numbers (R319.1)
ACCESSIBILITY (R320)
y Type B dwelling units applicable (R320.1)
ELEVATORS/PLATFORM LIFTS (R321)
A- Referenced standards (R321.1 - R321.3)
FLOOD -RESISTANT CONSTRUCTION (R322)
L, General (R322.1)
azard area and requirements (R301.2.4,
R309.3, R322.2, R322.3)
Design professional (R322.3.6)
STOF��VI SHELTERS (R323)
General and referenced standard (R323.1)
-4-
MATERIALS (R402)
Wood foundations (R402.1)
Concrete, compressive strength (R402.2)
i
FOOTINGS (R403)
Soil bearing value (R401.4; R403.1)
Footing width (see page 5)I'
Footing edge thickness = &' minimum; footing
projection = 2" minimum, but <_ footing
thickness (R403.1.1)
Footings in SDC C or D (R403.1.2, R403.1.3
and R403.1.6.1)
/Depth below (outside) grade = 12" minimum;
but below frost line except for frost pro-
tected footings.(R403.1.4, R403.1.4.1 and
R403.1.4.2)
(i/ /► Sill plate bolting in concrete/masonry ='/Z" di-
ameter bolts, within 12" but not less than 7
bolt diameters from corner, 7" embedment
(R403.1.6)
Footings adjacent to slopes (R403.1.7)
Frost protected shallow foundations (R403.3)
Footings for precast concrete foundation
(R403.4)
FOUNDAT IN WALLS (R404 - R406)
7Masonry foundation walls (R404.1.1)
_ Wall height, unbalanced backfill, nominal
thickness (Tables R404.1.1(1) -
R404.1.1(4), R404.1.5.11
Reinforcement size and spacing
(Tables R404.1.1(2) - R404.1.1(4)]
Con
FOUNDATIONS (Chapter 4)
aCo
foundation walls (R404.1.2)
Wall height, unbalanced backfill, nominal
thickness ITables R404.1.2(2) -
R404.1.2(8), R404.1.5.21
Horizontal and vertical reinforcement size and
spacing (Tables R404.1.2(1) - R404.1.2(8),
R404.1.2.2, R404.1.2.3.71
Stay -in -place forms (R404.1.2.3.6.1)
SDC C and D provisions. (R404.1.2.4,
R404.1.4)
Height above finished grade (R404.1.6)
Sill plate size (R404.3)
Precast concrete foundation walls (R404.5)
Drains required if habitable or usable spaces
are below grade* (R405)
Soil class (Table R405.1)
Dampproofing if basements are below grade*
(R406.1)
Waterproofing if high water table* (R406.2)
* If uninhabitable, see Under -Floor Space (R408)
COLUMNS (R407)
Protection from decay or corrosion (R407.1
and R407.2)
Structural requirements (R407.3)
All 6 Anchorage (R407.3)
Wood columns (minimum 4" square) (R407.3)
Steel columns minimum 3" diameter, Sched-
ule 40 pipe) (R407.3)
TABLE R403.1
eelNlMUM WIDTH OF CONCRETE. PRECAST OR MASONRY FOOTINGS (inc esla
LOAD -BEARING VALUE OF SOIL
1,500 2,000 3,000 > 4\000
Conventional li ht-frame construction
1-sto 12 12 12 12
2-story15 12 12 12
3-sto 23 17 12 12 ;
4-inch brick veneer over II ht frame or 8-inch hollow concrete masonry
1-sto 12 12 12 12
2-story21 16 12 12
3-story32 24 16 12
8-Inch solid or full routed masonry
1-sto 16 12 12 12
2-story29 21 14 12
3-story42 32 21 16
For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa
a. Where minimum footing width is 12 inches, a single wythe of solid or fully grouted 12—inch nominal concrete masonry units is permitted.
-5-
For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa
a. Where minimum footing width is 12 inches, a single wythe of solid or fully grouted 12—inch nominal concrete masonry units is permitted.
-5-
FOUNDATIONS (cont'd.)
UNDER -FLOOR SPACE (R408)
Ventilation (R408.1 and R408.2)
Unvented crawl space (R408.3)
Access (R408.4)
FLOORS (Chapter 5)
i
WOOD J ISTS AND GIRDERS (R502)
Species and grade (R502.1).
L/ Joists — Sleeping areas, LLI;= 30 psf
[Table R502.3.1(1)]
Joists — Nonsleeping areas,, LL = 40 psf
//] [Table R502.3.1(2)]
/V %( 1, Cantilevered joists [Tables RI502.3.3(1) and
R502.3.3(2)]
Girder spans and header spans for exterior
/bearing walls [Table R502.5(1)]
V_ Girder spans and header spans for interior
bearing walls [Table R502.5(2)]
/�
.'�� 1 Joists under bearing partitions,(R502.4)
Bearing (1.5" minimum on wood or metal; 3" on
masonry or concrete) and lapped joists (3")
(R502.6, R502.6.1)
Lateral restraint and bridging IR502.7,
R502.7.1)
Drilling and notching (R502.8)
. /Fastening (R502.9)
V Framing of openings (R502.10)
d trusses (R502.11)
:1�?Drao
ftstopping (R502.12)
LUMBERFLOORSHEATHING (R503.1)
i/�Il'owable span (Table R503.1)
i/ End joints (R503.1.1)
WOOD STRUCTURAL PANEL SHEATHING (R503.2) ST
Grade (R503.2.1)
Thickness (R503.2.1)
Allowable spans [Tables R503.2.1.1(1) and
R503.2.1.1(2)]
Installation [Table 602.3(1)]
Removal of debris (R408.5)
Finished grade (R408.6)
Flood resistance (R408.7)
PARTICLEBOARD UNDERLAYMENT (R503.3)
Grade (R503.3.1)
Thickness (R503.3.2)
Installation [Table R602.3(1)]
THE TED-WOOD FLOORS (ON GROUND) (R504)
Base course: 4" thick with maximum 1/4,
gravel or'/2" crushed stone (R504.2.1)
i
i Moisture barrier: placed over base course
(R504.2.2)
Materials (R504.3)
STE L FLOOR FRAMING (R505)
Cold -formed steel; applicability limits; in -line
framing (R505.1)
Structural framing (R505.2)
Material (R505.2.1)
Identification (R505.2.2)
Corrosion protection (R505.2.3)
Fastening (R505.2.4)
Floor construction (R505.3)
CONCRETE FLOORS (ON GROUND) (R506)
1zhickness: 31/2" minimum; Concrete strength
(R506.1)
_Support: prepared subgrade; maximum earth
fill = 8"; maximum sand or gravel fill = 24"
R506.2.1)
e course: 4" graded with 2" maximum
Base
(R506.2.2) ,
Vapor retarder (R506.2.3)
✓/ Reinforcement support (R506.2.4)
N
WALL CONSTRUCTION (Chapter 6)
GENERAL R601)
___,Design (R601.2)
�/ Component and cladding wind loads
[Table R301.2(2)]
Vapor retarders (R601.3)
WOOD CO STRUCTION (R602)
Construction (Figures R60Z3(1) and
/ R602.3(2)]
"' Stud grade (R602.2)
Exterior walls (R602.3)
Stud spacing [R602.3.1, Table R602.3(5)]
t/ Interior load -bearing walls (R602.4)
Interior nonbearing walls: 2" x 3" at 24" o.c.
or 2" x 4" flat at 16" o.c. (R602.5)
i
�nlling and notching — studs (R602.6)
rilling and notching —top plate (R602.6.1)
Headers (Tables R502.5(1), R502.5(2),
2602.7.2 and Figure R602.7.21
F//Fireblocking (R602.8, R302.11)
Cripple walls (R602.9)
Wall bracing, braced wall lines, lengths,
connections, support and joints (R602.10,
R602.10.1, R602.10.3, R602.10.6 -
R602.10.8)
Bracing based on wind speed
[Table R602. 1Q. 1.2(l)]
Bracing based on SDC [Table R602.10.1.2(2)]
Intermittent bracing methods (R602.10.2,
Table R602.10.2)
Continuous sheathing
(R602.10.4, R602.10.5)
Bracing for SDC C and D (R602.10.1.4.1,
R602.10.1.5, R602.11)
Wall bracing for stone and masonry veneer
(R602.12)
STEEL WALL FRAMING (R603)
General (R603.1)
_ Structural framing (R603.2)
Material (R603.2.1)
Identification (R603.2.2)
Corrosion protection (R603.2.3)
Fastening (R603.2.4)
Wall construction (R603.3 - R603.5)
Headers (R603.6)
Studs, tracks and structural sheathing
(R603.7 - R603.9)
SHEATHING (R604 and R605)
Wood structural panels (R604)
_ Particleboard (R605)
MASONRY CONSTRUCTION (R606 - R610)
General design (R606)
�_ SDC C and D (R606.12)
�' Unit masonry (R607)
MMultiple wythe masonry (R608)
Grouted masonry (R609)
Glass unit masonry (R610)
EXTERIOR CONCRETE WALL
CONSTRUCTION (R611)
e(I'Applicability (R611.2)
Concrete wall systems (R611.3)
Stay -in -place forms (R611.4)
Materials, construction details
(R611.5 - R611.10)
EXT7General;
WINDOWS & DOORS (R612)
window sills; performance; testing
and labeling (P612)
STRUCTURAL INSULATED PANEL WALL
CONSTRUCTION (R613)
Applicability (R613.2)
Materials (R613.3)
Wall panels, construction details JR613.4 -
R613.10)
-7-
WALL COVERING (Chapter 7)
INTERIOR WALL COVERING (R702)
-- Plaster material (R702.2)
Plaster support (R702.2.3)
Gypsum board material (R702.3.1)
Gypsum on, support, application and
/ fastening (R702.3.2 - R702.3.8)
eramic the (R702.4)
�
Other finishes (R702.5 and'R702.6)
EXTERI0�2 WALL COVERING (R703)
Water -resistive barrier (R703.2)
Wood siding (R703.3)
Attachment and minimum thickness
(Table R703.4)
Wood shakes and shingles (R703.5)
�erlor plaster (R703.6)
Stone & masonry veneer (R703.7 & Figure
R703.7); Steel angle lintels-4" minimum
r bearing each end (R703.7.3)
Il Veneer ties: #9 U.S. gage wire or #22 U.S.
gage by'/e"corrugated metal; 24" o.c.
maximum horizontal spacing; 2.67 square
feet maximum area supported (wind > 30 psf
and SDC C or D, maximum area = 2 square
feet) (R703.7.4.1)
Flashing (R703.7.5 and R703.8)
Exterior insulation and finish systems (R703.9)
Fiber cement siding (R703.10)
Vinyl siding (R703.11)
ROOF -CEILING CONSTRUCTION (Chapter 8)
GENERALL (R801)
y Design (R801.2 and R801.3)
_L�Component and cladding wind loads.[Tab/e
R301.2(2)]
ROOF FRAIy11NG (R802)
,Fire -retardant -treated wood (R802.1.3)
Framing details (R802.3)
i�- Rafter tie (R802.3.1)
Collar ties (4' o.c., in upper third of attic)
(R802.3.1)
Purlins (2" x 4" at 4' o.c. minimum)
/ (Figure R802.5.1, R802.5.1)
v Bearing (R802.6)
o� ttting and notching (R802.7)
gineered wood products (R802.7.2)
;eral support and bridging (R802.8)
aming of openings (R802.9)
�=ooftie-down
d trusses (R802.10)
(R802.11)
CEILING�JOISTS [Tables R802.4(1), R802.4(2)]
�// Without attic storage, LL = 10psf
With attic storage LL = 20psf
Spacing
—�. species
Grade
Span
�ize
RA�S (fables R802.5.1(1) - R802.5.1(8)]
Ground snow load/LL = 20psf
Controlling design (LL or snow)
Ceiling not attached/ceiling attached
Spacing
Species
Grade
Span
Size
Hc/HR; Adjustment factor
ROOF SFjEATHING (R803.2)
ROOF
,,'thickness
�FRTW allowable stresses/grading
::5::Allowable spans (fable R503.2.1.1(1))
Installation (R803.2.3)
CHIMNEYS AND FIREPLACES (cont'd.)
Changes in dimension (R1003.6)
Chimney clearance (R1003.18)
Additional load (R1003.8)
Fireblocking (R1003.19)
Termination (R1003.9)
Chimney crickets (R1003.20
Spark arrestors (RI 003.9.1)
FACTORY -BUILT FIRER S (R1004)
Wall thickness; >_ 4" (R1003.10)
' ed and labeled (R1004.1)
Flue lining - material/installation (R1003.11
Installation (R1004.2)
and R 1003.12)
FACTORY -BUILT CHIMNEYS (R1005)
Multiple flues (R1003.13)
Listed and labeled (R1005.1)
Flue area (appliance) (R1 .14)
Installation (R1005.3 and R1005.4)
Flue area (maso fireplace) (R1003.15)
Inlet (R1 .16)
EXTERIOR AIR SUPPLY (131006)
anout opening (R1003.17)
Intake size (R1006.2, R1006.4)
ENERGY EFFICIENCY* (Chapter 11)
Compliance; material and equipment B 'Iding envelope (N1102)
(N1101.2, N1101.3) Mechanical systems (N1103)
Climate zone (Table N1101.2)
'See energy conservation plan review record
MECHANICAL (Chapters 12-23)
Appliance labeling (M130Z M1303) Chimney and vent location and terminations
Appliance access (M1305, M1401)
Appliance installation (M1307)
Heating and cooling equipment; heating
and cooling load calculations (Chapter 14)
Exhaust systems (Chapter 15)
Duct systems (Chapter 16)
Combustion air (Chapter 17)
(Chapter 10 and Chapter 18)
Special fuel -burning equipment (Chapter 19)
Boilers/water heaters (Chapter 20)
Hydronic piping (Chapter 21)
Special piping and storage systems
(Chapter 22)
Solar systems (Chapter 23)
Penetrations of fire -resistance rated assem-
blies (R302.4, R302.5)
FU L G S (Chapter 24)
Application (G2401.1) Cle
General regulations (G2404) Electrical and electrical bonding (G2410,
G2411)
Appliance locatio 6)
Pipe sizing (G2413)
urements (G2407)
Piping materials (G2414)
Installation (G2408)
-10-
FUEL S (cont'd)
Piping installation G2415 and G2419)
P 9 (
Piping support (G2418 and G2424)
L Valves, co c ions (G2420, G2421
Misc appliances (G2423, G2425, G2430 -
G2453)
PLUMBING (Chapters 25-33)
Water service location and depth (P2603, Sprinkler coverage
P2604) (P2904.2.4)
Sanitary and storm sewer location and depth Piping materials (P2904.3)
(P2603, P2604)
Flow rates (P2904.4.1,
Piping support (Table 152605.1) P2904.4.2)
Listed plastic materials (P2608)
Water supply capacity
(P2904.5.2)
Plumbing fixtures (Chapter 27)
Water heater size and location (Chapter 28)
Pipe sizing (P2904.6)
Water supply and distribution system design
Drain, waste and vent pipe sizing and riser
diagram (P3004, P3005, Chapter 31)
and calculations (Chapter 29)
Dwelling unit fire sprinkler systems (P2904)
Sumps and ejectors (P3007)
Backwater valves (P3008)
NFPA 13D system (P2904.1)
Fixture traps (P3201)
Temperature rating
(P2904.2.1, P2904.2.2)
Storm drainage (Chapter 33)
Freezing protection
Penetrations of fire -resistance rated assem-
(P2904.2.3)
blies (R302.4, R302.5)
ELECTRICAL (Chapters 34-43)
Penetrations of fire -resistance rated assem-
Wiring methods (Chapter 38)
blies (E3402.2)
Required lighting and receptacle outlets
Listed and labeled materials (E3403)
(E3901, E3903)
Service equipment and location (E3405,
Ground -fault and arc -fault circuit -interrupter
E3601, E3606)
protection (E3902)
Service size and load calculations (E3602)
Devices and lighting fixtures (Chapter 40)
Available fault current'(E3606)
Appliance installation (Chapter 41)
System grounding (E3607)
Swimming pools (Chapter 42)
Required branch circuits (E3703)
Class 2 remote -control, signaling and power -lim-
ited circuits (Chapter 43)
Feeder requirements and load calculations
(E3704)
MANUFACTURED HOUSING USED AS DWELLINGS (Appendix E)
Provisions adopted (R102.5) ompliance with Appendix E verified
-11-
RADON CONTROL MEASURES (Appendix F)
Provisions adopted (R102.5) tl Compliance with Appendix F verified
SWIMMING POOLS, SPAS AND HOT TUBS (Appendix G)
Compliance with
Provisions adopted (R102.5) P Appendix G verified
PATIO CO ERS (Appendix H)
Provisions adopted ( (" / ' Compliance with Appendix H verified
R102.5 )
PRIVATE SEWAGE DISPOSAL (Appendix 1)
Provisions ( ) R102.5 adopted Compliance with Appendix I verified
P .
EXISTING BUILDINGS AND STRUCTURES (Appendix J)
Provisions adopted (R102.5) Compliance with Appendix J verified
SOUND TRAN MISSION (Appendix K)
Provisions adopted (R102.5) Compliance with Appendix K verified
HOME DAY CARE— -3 OCCUPANCY (Appendix M)
Provisions adopted (R102.5) Compliance with Appendix M verified
-12-
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462-6443
,I
RI 9 a9P.10"R t
FLOOD HAZARD NOTICE
PERMIT NUMBER: 1303-0067 3/8/2013
LOCATION: 63 NETTLES BLVD
JENSEN BEACH
L E, -00- 0 Py
CONTRACTOR: JAMES W NEWMAN
i
DBA: JWN CONSTRUCTION INC
OWNER: Wayne D Thomas
NOTICE
This Notice is to inform you that your property is in a Flood Hazard Zone.
This means that the elevation for the first floor must be set at 6 feet, NAVD (mean sea level), or 18" above the crown of the road
whichever is'greater.
NO CONSTRUCTION is to proceed beyond the 1st floor/slab inspection, orjust prior to the second floor pour of a multi -story structure,
until the required elevation certification has been completed by a registered surveyor, and received and approved by the Building Division
of the St. Lucie County Community Development Department.
Violation of the requirement will result in the scheduling of a public hearing before the St. Lucie County Code Enforcement Board. The
Board is empowered to levy a fine not to exceed $250.00 per day for each day the violation continues. A fine not to exceed $500.000 per
day may be levied for a repeat violation. The fine may become a lien upon the real or personal property of the violator.
The elevation certification may be submitted any time within 21 calendar days from the above; however, no further construction should
take place, nor will any inspections be made until the required certification has been received and approved.
c
Signature
Date