Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEENERGY PERFORMANCE LEVEL (EPL 41,ANN DISPLAY CARD ESTIMATED ENERGY, PERFORMANCE INDEX* = 77 The lower the EnergyPerformance Index, the more efficient the home. Lot M Nettles Island Blvd., Fort Pierce, FL, 1. New construction or existing New3 m Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1460.00 ft2 b. Frame - Wood, Exterior R=13.0 132.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 1 d. N/A R= ft2 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Sgl, U=0.29 SHGC: SHGC=0.22 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 10. Ceiling Types Insulation Area No a. Under Attic (vented) R=19.0 849.00 ft2 1304 b. N/A R= ft2 c. N/A R= ft2 Area 11. Ducts R ft2 128.00 ft2 a. Sup: RoomslnBlook1, Ret: RoomslnBlockl, AH: 6 169.8 ft2 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 30.0 SEER:15.00 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= ft2 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 38.7 HSPF:9.00 0.000 ft. 0.220 Area 14. Hot water systems Cap: 1 gallons 849.00 ft2EF: a. Electric 0.91 ft2 b. Conservation features ft2 None 15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will' be completed based on installed Code 7Lplianlfeatur Builder Signature: Date: -Z J 3 Address of New Hom 61?3 Al &r� e City/FL Zip: l- Ll I *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Wayne Thomas Residence Bedrooms: 1 FLProp2010 Conditioned Area: 1304 Wayne Thomas Total Stories: 2 1 Worst Case: No Rotate Angle: 0 St. Lucie County Cross Ventilation: Whole House Fan: Single-family New (From Plans) Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address Lot 65 Nettles Island BI St. Lucie Fort Pierce , FL, CLIMATE V Design Location IEC,C Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1 1304 10432 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 RoomslnBlock1 1304 10432 Yes 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio RoomslnBlock1 849 ft 0 849 ft2 ____ 0 0 1 ROOF v # Type Roof, Gable Roof Materials Area, Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) , 1 Hip Metal 920 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 849 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) RoomslnBlock1 19 849 ft2 0.11 Wood 2/28/2013 10:44 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below u Ornt To Wall TypeSpace R-Value Ft In Ft in Area R-Value Fraction Absor Gra .# 1 N Exterior Concrete Block - Int InsBloomslnBloc 5 12 8 96 ft2 0 0.75 0 2 NW Exterior Concrete Block - Int InsI9oomsInBloc 5 12 8 96 ft2 0 0.75 0 3 E Exterior Concrete Block - Int Insl3oomsInBloc 5 30 8 240 ftZ 0 0.75 0 4 S Exterior Frame - Wood RoomslnBloc 13 16.5 8 132 ft2 0.23 0.75 0 5 S Exterior Concrete Block - Int InsRoomslnBloc 5 4.5 8 36 ft2 0 0.75 0 6 W Exterior Concrete Block - Int InsigoomslnBloc 5 4 8 32 ft2 0 0.75 0 7 W Exterior Concrete Block - Int Insel00mSlnBloc 5 35 8 280 ft2 0 0.75 0 8 S Exterior Concrete Block - Int InsBloomslnBloc 5 21.5 8 172 ft2 0 0.75 0 9 E Exterior Concrete Block - Int InsBloomslnBloc 5 40.5 8 324 ft2 0 0.75 0 10 N Exterior Concrete Block - Int InsEl00mSlnBloc 5 23 8 184 ft2 0 0.75 0 DOORS # Ornt Door Type Space Storms U-Value FtWidthArea Ft In In 1 N Wood RoomslnBloc None 0.460000 3 7 21 ft2 2 W Wood RoomslnBloc None 0.460000 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 NW 2 Metal Single (Tinted) Yes 0.29 0.22 N 4 ftZ 0 ft 0 in 0 ft 0 in HERS 2006 None 2 E 3 Metal Single (Tinted) Yes 0.29 0.22 N 8 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 3 W 6 Metal Single (Tinted) Yes 0.29 0.22 N 4 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 4 W 7 Metal Single (Tinted) Yes 0.29 0.22 N 8 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 5 S 8 Metal Single (Tinted) Yes 0.29 0.22 N 42 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 6 E 9 Metal Single (Tinted) Yes 0.29 0.22 N 20 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 7 N 10 Metal Single (Tinted) Yes 0.29 0.22 N 42 ft2 0 ft 0 in 0 It 0 in HERS 2006 None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 382.8 ft2 382.8 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 BySpaces Proposed SLA 0.000360 1231.3 67.599 127.13 0.3235 7.0821 2/28/2013 10:44 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 I 1�, HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 9 38.7 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 15 30 kBtu/hr 900 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.9108 1 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None fF DUCTS =-- Supply — — Return — Air Percent HVAC # # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF Heat Cool 1 RoomslnBloc 6 169.8 ft RoomslnBloc 42.45 ft DSE=0.88 RoomslnBl 0.0 cfm 0.00 % 0.00 0.60 1 1 TEMPERATURES Programabl[eXX]Thermostat: Y Ceiling Fans: Heat ng [ X] Jan EX] Feb . EX� Mar Ap Apr Jun Jul May XX� Jun Ri Jul Aug S:p Aug �X� Sep Oct rxiOcctt Nov rXINov Dec Dec Venting [[XX]] Jan [[j Feb [X Mar lx� X� X� Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 • 78 78 78 78 78 80 80 80 80 PM .80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 '68 66 66 2/28/2013 10:44 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 f . d , FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: Lot 65 Nettles Island Blvd. PERMIT #: Fort Pierce, FL, MANDATORY REQUIREMENTS SUMMARY -,See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting. IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated' pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 2/28/2013 10:44 PM Energy0auge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5