HomeMy WebLinkAboutENERGY EFFICIENCY CODEENERGY PERFORMANCE LEVEL (EPL
41,ANN
DISPLAY CARD
ESTIMATED ENERGY, PERFORMANCE INDEX* = 77
The lower the EnergyPerformance Index, the more efficient the home.
Lot M Nettles Island Blvd., Fort Pierce, FL,
1. New construction or existing New3 m Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1460.00 ft2
b. Frame - Wood, Exterior R=13.0 132.00 ft
3. Number of units, if multiple family 1 c. N/A R= ft2
4. Number of Bedrooms 1 d. N/A R= ft2
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows- Description
a. U-Factor: Sgl, U=0.29
SHGC: SHGC=0.22
b. U-Factor: N/A
SHGC:
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
10. Ceiling Types
Insulation
Area
No a. Under Attic (vented)
R=19.0
849.00 ft2
1304 b. N/A
R=
ft2
c. N/A
R=
ft2
Area 11. Ducts
R ft2
128.00 ft2 a. Sup: RoomslnBlook1, Ret: RoomslnBlockl,
AH:
6 169.8
ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2 a. Central Unit
30.0
SEER:15.00
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A R=
c. N/A R=
ft2
13. Heating systems
kBtu/hr Efficiency
a. Electric Heat Pump
38.7 HSPF:9.00
0.000 ft.
0.220
Area
14. Hot water systems
Cap: 1 gallons
849.00 ft2EF:
a. Electric
0.91
ft2
b. Conservation features
ft2
None
15. Credits
CF, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will' be completed
based on installed Code 7Lplianlfeatur
Builder Signature: Date: -Z J 3
Address of New Hom 61?3 Al &r� e City/FL Zip:
l-
Ll I
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Wayne Thomas Residence Bedrooms: 1
FLProp2010 Conditioned Area: 1304
Wayne Thomas Total Stories: 2
1 Worst Case: No
Rotate Angle: 0
St. Lucie County Cross Ventilation:
Whole House Fan:
Single-family
New (From Plans)
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
Lot 65 Nettles Island BI
St. Lucie
Fort Pierce ,
FL,
CLIMATE
V Design Location
IEC,C Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_ST LUCIE_CO_INTL 2 39 90
70
75 722
62 Low
BLOCKS
Number
Name
Area Volume
1
Block1
1304 10432
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
RoomslnBlock1
1304 10432 Yes 1
1
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio RoomslnBlock1 849 ft 0
849 ft2
____
0 0 1
ROOF
v #
Type
Roof, Gable Roof
Materials Area, Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg) ,
1
Hip
Metal 920 ft2 0 ft2 Medium
0.96
No 0.9
No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300
849 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac
Truss Type
1
Under Attic (Vented)
RoomslnBlock1 19 849 ft2
0.11
Wood
2/28/2013 10:44 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
u
Ornt
To
Wall TypeSpace
R-Value Ft In
Ft in
Area
R-Value Fraction Absor
Gra
.#
1
N
Exterior
Concrete Block - Int InsBloomslnBloc
5 12
8
96 ft2
0 0.75
0
2
NW
Exterior
Concrete Block - Int InsI9oomsInBloc
5 12
8
96 ft2
0 0.75
0
3
E
Exterior
Concrete Block - Int Insl3oomsInBloc
5 30
8
240 ftZ
0 0.75
0
4
S
Exterior
Frame - Wood RoomslnBloc
13 16.5
8
132 ft2
0.23 0.75
0
5
S
Exterior
Concrete Block - Int InsRoomslnBloc
5 4.5
8
36 ft2
0 0.75
0
6
W
Exterior
Concrete Block - Int InsigoomslnBloc
5 4
8
32 ft2
0 0.75
0
7
W
Exterior
Concrete Block - Int Insel00mSlnBloc
5 35
8
280 ft2
0 0.75
0
8
S
Exterior
Concrete Block - Int InsBloomslnBloc
5 21.5
8
172 ft2
0 0.75
0
9
E
Exterior
Concrete Block - Int InsBloomslnBloc
5 40.5
8
324 ft2
0 0.75
0
10
N
Exterior
Concrete Block - Int InsEl00mSlnBloc
5 23
8
184 ft2
0 0.75
0
DOORS
#
Ornt
Door Type Space
Storms U-Value
FtWidthArea
Ft
In
In
1
N
Wood RoomslnBloc
None
0.460000 3
7
21 ft2
2
W
Wood RoomslnBloc
None
0.460000 3
7
21 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor SHGC Storms Area
Depth
Separation Int Shade
Screening
1
NW 2
Metal Single (Tinted) Yes
0.29 0.22 N
4 ftZ
0 ft 0 in
0 ft 0 in HERS 2006
None
2
E 3
Metal Single (Tinted) Yes
0.29 0.22 N
8 ft2
0 ft 0 in
0 ft 0 in HERS 2006
None
3
W 6
Metal Single (Tinted) Yes
0.29 0.22 N
4 ft2
0 ft 0 in
0 ft 0 in HERS 2006
None
4
W 7
Metal Single (Tinted) Yes
0.29 0.22 N
8 ft2
0 ft 0 in
0 ft 0 in HERS 2006
None
5
S 8
Metal Single (Tinted) Yes
0.29 0.22 N
42 ft2
0 ft 0 in
0 ft 0 in HERS 2006
None
6
E 9
Metal Single (Tinted) Yes
0.29 0.22 N
20 ft2
0 ft 0 in
0 ft 0 in HERS 2006
None
7
N 10
Metal Single (Tinted) Yes
0.29 0.22 N
42 ft2
0 ft 0 in
0 It 0 in HERS 2006
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
382.8 ft2 382.8 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 BySpaces Proposed SLA 0.000360 1231.3 67.599
127.13
0.3235
7.0821
2/28/2013 10:44 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
I
1�,
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump
None
HSPF: 9
38.7 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow
SHR
Block
Ducts
1
Central Unit
None
SEER: 15
30 kBtu/hr 900 cfm
0.75
1
sys#1
HOT WATER SYSTEM
#
System Type SubTpe
Location
EF Cap
Use SetPnt
Conservation
1
Electric Tankless
Garage
0.9108 1 gal 40 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert
# Company Name
System Model # Collector Model # Area
Volume
FEF
None None
fF
DUCTS
=-- Supply —
— Return —
Air
Percent
HVAC #
#
Location R-Value Area
Location
Area Leakage Type
Handler CFM 25
Leakage QN
RLF
Heat Cool
1
RoomslnBloc 6 169.8 ft RoomslnBloc 42.45 ft DSE=0.88
RoomslnBl 0.0 cfm
0.00 % 0.00
0.60
1 1
TEMPERATURES
Programabl[eXX]Thermostat: Y
Ceiling Fans:
Heat ng [ X] Jan EX] Feb . EX� Mar
Ap
Apr
Jun Jul
May XX� Jun Ri Jul
Aug S:p
Aug �X� Sep
Oct
rxiOcctt
Nov
rXINov
Dec
Dec
Venting [[XX]]
Jan [[j Feb [X Mar
lx�
X�
X�
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7 8
9
10
11
12
Cooling (WD)
AM 78
78 78 •
78 78 78
78 78
80
80
80
80
PM .80
80 78
78 78 78
78 78
78
78
78
78
Cooling (WEH)
AM 78
78 78
78 78 78
78 78
78
78
78
78
PM 78
78 78
78 78 78
78 78
78
78
78
78
Heating (WD)
AM 66
66 66
66 66 68
68 68
68
68
68
68
PM 68
68 68
68 68 68
68 68
68
68
66
66
Heating(WEH)
AM 66
66 66
66 66 68
68 68
68
68
68
68
PM 68
68 68
68 68 68
68 68
68
'68
66
66
2/28/2013 10:44 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
f . d ,
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: Lot 65 Nettles Island Blvd. PERMIT #:
Fort Pierce, FL,
MANDATORY REQUIREMENTS SUMMARY -,See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting. IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated' pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
2/28/2013 10:44 PM Energy0auge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5