Loading...
HomeMy WebLinkAboutNOAle M AM MIAMI-DADE COUNTY MM PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/building Mlkron Industries Inc. 1034 Sixth Avenue North Kent, WA 98032 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority CA Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section Miami C9 (In Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right `�z to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC _5 reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control -31 Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: The approved White Rigid PVC Exterior Extrusions for Windows and Doors are to be produced by Extruders Licensees in "AAMA Certification Programs for rigid PVC Extrusions". The extrusions shall meet ASTM D 4726, classification (ASTM D 4216) 1-10154-33-0000,1-20131-13-0000 or 1-40131-13 and the following properties. Description Test Properties Rate of Burning ASTM D-635 Class Cl Self Ignition temperature ASTM D-1929 9250F > 650 Average Smoke Density Rating ASTM D-2843 43% < 75 .Flame Spread Index ASTM E-84 26.2 < 75 Tensile Strength (Difference: *Exposed & Unexposed) ASTM D-638 498% < 10 *Exposed per Section 2605.2 of The Florida Building -Code. MISSILE UffACT RATING: None This NOA renews NOA # 06-1220.01 and consists of pages 1 and 2, as well as evidence page E-1. The submitted documentation was reviewed by Carlos M. Utrera, P.E. 1/ NOA No: 11-0830.09 F ecou a91�°� Expiration Date: December 26, 2016 Approval Date: October 06, 2011 Page I MIAMI,EaADE MIAMI-DADE COUNTY B PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Fiorlda 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamldade.gov/building NOTICE OF ACCEPTANCE (NOA) Mikron Industries Inc. 1034 Sixth Avenue North Kent, WA 98032 LIMITATION: This approval does not include an evaluation of structural performance of this component. Test reports and other required documents shall be submitted to Dade County Product Control; showing that the systems using this PVC Extrusion will resist the loads according to Chapter 16 of the F.B.C., in order to issue a specific product approval for the system. LABELING: Each carton containing certified extrusions shall be labeled with the AAMA PVC Extrusion Certification Label with the extruder name, city, state and "MDCA". In addition, (a) each Certified Extrusion shall be labeled every 4 ft or less on the underside with the Extruder Code and "MDCA" or (b) each window assembly shall be labeled with a permanent label and/or stamp with the Extruder Code and "MDCA". RENEWAL of this NOA shall be considered after a renewal application has been fried and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. v9�3%oil NOA No: 11-0830.09 MIAMIOADEe NW Expiration Date: December 26, 2016 ,APPROYED Approval Date: October 06, 2011 -Page 2 Mikron Industries Inc. NOTICE OF ACCEPTANCE: EVIDENCE PAGE don A. DRAWINGS 1. None. B. TESTS LEA 1. Test report on Rate of Burning, Ignition Temperature, Density of Smoke, Surface Burning Characteristics, Accelerated Weathering and Tensile Properties Test of "PVC Extrusions from 5 different manufacturer" selected by AAMA', prepared by ETC Laboratories, report # ETC 97-264-40910, dated 04/21/98, signed and sealed by J. L. Doldan, P.E. (Evidence Submitted under AAMA Certfcatlon No. 98-0036) C. CALCULATION 1. None D. QUALITY ASSURANCE 1. Miami -Dade Building and Neighborhood Compliance Department (BNC) E. MATERIAL CERTIFICATION I. _AAMAP_ublication-No.-1,09-97. 2. AAMA Publication No. 303-97. . 3. AAMA Certified PVC Extrusion Listing. (Evidence Submitted under AAMA Certication No. 98-0036) F. STATEMENTS 1. Non Financial Statement Letter by R.E. Fisher and Associates issued on 05/31/98 and signed by R.E. Fisher. 2. Code Compliance Letter by RE Fisher and Associates issued on 05/31/98 and signed by R.E. Fisher 3. Non -financial Statement by ETC Laboratories issued on 06/12/98 and signed by D. Kehali. (Evidence Submitted underAAAL4 Certfflcadon No. 98-0036) G. OTHERS (Evidence Submitted under NOA # 06-1220.01) 1. Member acknowledgement letter issued by Mikron Industries, Inc. - Spectus Systems, on 08/03/61 and signed by Douglas W. Allen. 2. Component Release Letter issued by American Architectural Manufacturers Association on 09/07/01 and signed by Dean Lewis. 0'7P91v171'111 Carlos M. Utrera, P.E. Product Control Examiner NOA No 11-0830.09 Expiration Date: December 26, 2016 Approval Date: October 06, 2011 E-1 MIAMDIADE MIAMI-DADE COUNTY EM PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami. Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) ww.minmidnde.eoy&dldiae E.I. DuPont De Nemours & Co., Inc. DuPont P&IP Chestnut Run Plaza, 712/161, P.O. Box 80712 Wilmington, DE 19880 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. -DESCRIPTION: DuPont SentryGlas® Interlayer APPROVAL DOCUMENT: Drawing No. 10-0413.04, titled "DuPont SentryGlas® Interlayer", sheet 1 of 1, dated 04/13/11, prepared by E.I. DuPont De Nemours & Co., Inc., signed and sealed by Allan A. Kozich, P.E., bearing the Miami -Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: None. LABELING: Laminated lites under this Product Approval shall be permanently marked in a corner of the glass with: "MDCA - SentryGlas®", standing for "Miami -Dade County Approved — SentryGlas®", and the laminator's identification mark. These marks shall be applied by the individual laminator producing the finished laminated glass product containing the SentryGlas® interlayer. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 10-0413.04 and consists of this page, evidence page E-1, as well as approval document mentioned above. . The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No: 11-0624.02 MIAMMAI)Beourm Expiration Date: January 14, 2017 Approval Date: August 25, 2011 Page 1 E.I. DuPont De Nemours & Co.. Inc. NOTICE OF ACCEPTANCE: EVIDENCE PAGE_ A. DRAWING 1. Drawing No.10-0413.04, titled "DuPont SentryGlas® Interlayer", sheet I. of 1, dated 04/13/11, C prepared by B.I. DuPont Do Nemours & Co., Inc., signed and sealed by Allan A. Kozich, P.E. u B. TEST REPORTS Laboratory Report Test Date Signature 1. 96177.02-106-18 ASTM D 635 02/22/10 Joseph A. Reed, P.E. 2. 96177.02-106-18 ASTM D1929 02/22/10 Joseph A. Reed, P.E. ' 3. 96177.02-106:19' ' ASTM D2843' 02/22/10 Joseph A.'Xded, P:E. "Submitted under NOA # 10-0413.04" 1. 3136116SAT-001 ASTM D 635 10/25/07 Chris Bowness, P.E. 2. 3111755SAT-002 ASTM D1929 01/02/07 Chris Bowness, P.E. 3. 3111755SAT-001 ASTM E 84 12/19/06 Chris Bowness, P.E. 4. • PRIO6246 ASTM G 26 06/26/07 Due T. Nguyen, P.E. 5. PR106246 ASTM D 790 06/26/07 Due T. Nguyen, P.E. "Submitted under NOA # 07-1116;04" C. CALCULATIONS• 1. _ Moms — D. MATERIAL CERTIFICATIONS 1. None. E. QUALITY ASSURANCE 1. Miami -Dade Building and Neighborhood Compliance Department (BNC) F. STATEMENTS 1. Statement letter of code conformance to 2007 FBC and no financial interest issued by Allan A. Kozich & Associates, dated 08/09/11, signed and sealed by Allan A. Kozich, P.E. 2. Laboratory 2007 F.B.0 compliance letter issued by Architectural Testing, Inc., dated 02/22/10, signed and sealed by Joseph A. Reed, P.E. "Submitted under NOA # 10-0413.04" 3. Approved listing of SentryGlas® Plus laminators dated November 30, 2005, signed by Jeffrey D. Granato. "Submitted under NOA # 06-1205.10" L"ALM"M Carlos M. Utrera, P.E. Product Control Examiner NOA No 11-0624.02 Expiration Date: January 14, 2017 Approval Date: August 25, 2011 E-1 DUPONT SENTRYGLAS® INTERLAYER PRODUCT DESCRIPTION MANUFACTURED BY: E.I. DUPONT DE NEMOURS & CO., INC. DESCRIPTION: A PLASTIC INTERLAYER MATERIAL WHICH IS FACTORY LAMINATED TO A MINIMUM OF TWO PIECES OF GLASS. A TYPICAL GLAZING IS MADE OF THE FOLLOWING COMPONENTS: (MINIMUM THICKNESS INDICATED. MULTIPLE PLIES OF INTERLAYER TO BE USED AS NECESSARY), A B C 1A - 1/8" 3.0 mm Annealed Glass SECTION IB - 0.030" 0.76 mm DuPont SentryGlas@ Interla er C - 1/8" 3.0 mm Annealed Glass MATERIAL CHARACTERISTICS SentryGlas® Interlayer Designation Test Properties Flame Spread Index ASTM E84 35 Smoke Developed Index ASTM E84 250 Flash Ignition Temperature [11 ASTM D1929 788 F Flash Ignition Temperature [21 ASTM D1929 752 F Self l nition Tem erature [11 ASTM D1929 806 F Self Ignition Temperature [21 ASTM D1929 770 F Average Extent of Burning 1 ASTM D635 0 cm/min.; Class C1 Average Extent of Burning 2 ASTM D635 0 cm/min.; Class CC1 Average Modulus of Rupture ASTM D790 WeatherI " "WEATHERING PER SECTION 2612.2 OF THE FLORIDA BUILDING CODE Before After b 415 si 5,366 psi NOTES: [1] 30 mil (0.76mm) thickness DuPont SentryGlasS Interlayer Sample [2] 180 mil (3.3mm) thickness DuPont SentryGlasS Interlayer Sample [3] DuPont SentryGlasS Interlayer by Itself Does Not Comply With the Florida Building Code THIS IS A COMPONENT APPROVAL AND DOES NOT INCLUDE AN EVALUATION OF STRUCTURAL PERFORMANCE OF THIS COMPONENT. SYSTEMS INCORPORATING THIS COMPONENT SHALL APPLY FOR A PRODUCT APPROVAL TO THIS OFFICE AND SHALL SUBMIT REPORTS AND OTHER REQUIRED DOCUMENTS SHOWING THAT THE SYSTEM USING THIS COMPONENT WILL RESIST THE LOADS ACCORDING TO CHAPTER 16 OF THE FLORIDA BUILDING CODE. + ilR9iflJCT IlBNfiwi p DIYC w0 ft 9k w 13 DuPont SentryGlas® Interlaver E.I. duPont de Nemours & Co., Inc. DuPont P&IP - GLS ' Chestnut Run Plaza Bldg 712/161 P. O. Box 80712 WII 'ngton DE 19880-0712 Phone: 302-999-2125 Dwg. 10-0413.04 rev 1. Sheet 1of 1 ;:,• Drawing Date: 04/13/11 I 2 2011 Allan A. Kozich, PE :1'tN 1 Registration # 16864 Item # Part# DescripPVtion Vendor Material 1 H-6031 w/ Maln Fr., SH, Fig., C, Head MIKRON PVC 2 -6031 Main Fr., SH, w/Flg., PVC, SIII MIKRON PVC 3 603 Main Fr., SH, w Flg., P C, L. Jb. MIKRON PVC 4 H:9031 Main Fr., SH, w/Fig., PVC, R. Jb. MIKRON PVC 5 -1 881 Heavy Duty, Meet. Rail, Fxd. Aluminum KEYMARK LIM 6 :9027 Sash Meet. Rail, PVC MIKRON PVC 7 1497 Reinf. Sash Meet. Rail KEYMARK ALUM 8 -6004 Sash Bottom Rail Side Rail PVC MIKRON PVC 9 S-1498 Reinf. S.B.R. S.S.R KEYMARK ALUM 10 S-6064 Glazing Bead, 7/8" MIKRON PVC 11 013 Scm. Adapt., WNW, PVC, Hodz. MIKRON PVC 12 S-6014 Scm. Adapt., PVC, Vert. MIKRON PVC 13 5-6029 Sash Stop / FII er, PVC, Vert. MIKRON PVC 14 H 1699 Reinforcement, SBR KEYMARK ALUM 15 P-2190 Balance BSI 6 5-3059 Sash Cam, PVC M&M NYLON 17 P-3046 Take Out CI p 18 P-3783 Spring Lock, Impact, PVC INTERLOCK 19 P-3784 Spring Lock Keeper, Impact, PVC INTERLOCK 20 P-3215 WeepCoverw Flap M&M . NYLON 21 5-60 77 HD Fixed Meeting Rail Cover MIKRON PVC 22 P-3429 Wstp., 0.270 x .187 back FinSeal, Gray ULTRAFAB 23 F 638 #8 x 2-1/2 PH Mod. Truss, Type A, TEK 2 FASTENAL STEEL 25 P-4051W #8 x 1.250 Ph FH TEK, Wht. FASTENAL STEEL 26 P-3748W #6 x 0.625 Quad FH TEK, Wht. FASTENAL STEEL -27-- - 7P:342 Seam Sealer, SM-5504 -SCHNEE - 28 P 3752 Cap Plug, 1 2" Hole M&M NYLON 29 P-3438 Sikaflex 552 or Purfect Glaze "H" SIKNHENKEL 30 P-3352 Set. Blk., 85 Dur., 1 B° x 5/9" x 2" Lg. FRANK LO RUBBER 31 P-3881 Temporary L I. NFRC DP 32 P-3613 CWS Lbl. (logo) 33 Sas SEE PAGE 3 FOR GLASS TYPE 34 Fixed SEE PAGE 3 FOR GLASS TYPE 35 1688 Hig rise Sill KEYMARK ALUM 36 P 3281 DuraSeal TRUSEAL 37 P-3113 Screw Support for PVC RUBBER TEAM 38 5-1577 Impact Hook KEYMARK ALUM 39 P-3 8 Keeper, Sweep Lack SULLIVAN STEEL 40 P-3541 #8 x 1/2, Pan Head, TEK FASTENAL ZINC 41 P-4632 Sweep Lock SULLIVAN ZINC 42 P-4633 Barrel Fastener FASTENAL STEEL 43 H-6026 Main Fr., SH, w/Fin, P C MIKRON PVC 44 -6028 Sash,Bottom Rai MIKRON PVC 45 S-1 12 Glaze Bead reinforcement KEYMARK ALUM 1 � 3/4" 1116" 3/11.66" i 9 REINF. S.B.R./S.S.R. -1498 ALUMINUM 6063-T6 �....I 3 .7L-11O 3" 3/16'J SCREW SUPPORT-3113 1l4' .070° r-F7/8" 10 PVC GLAZING BEAD-6064 21 PVC FRAME FLANGE-6031 2 3/16" 1/16" 1 5/� 6 PVC SASH MTG. RAIL-6027 3 PVC FRAME FIN-6026 PVC SASH BTM RAIL-6028 ¢ 3116° to] II Im T71{8°F 1 +i 38 IMPACT HOOK -1577 (ALUM 6063-T6) 3!8" 3 7 1 6" 3 1!8° REINF. SASH MTG. RAIL-1497 1/1s• ALUMINUM 6063-T6 HIGH RISE SILL - 1688 ALUMINUM 6063-T6 PROPRIETARY AND CONFIDENTIAL 11/28/11 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS, INC. IS PROHIBITED. �1 3/16" 1116" 1 518" e u PVC SASH SIDE RAIL-6004 1116' 5/16" 1 PVC SCREEN SUPPORT - 6014 1 118" 1 " 11 r---1 3/4' - .045" 1 5/16" II 1 � h— 2 3/16" PVC HD MTG RAIL COVER-6077 3/4" 14 151,6" I �I 1/16' REINF. SASH BTM RAIL-1699 ALUMINUM 6063-T6 'Pp1DREty 'v : No 58201 a 9 STATE OF �FSA'C O R t D P, •��hs/ONA ; Ej G CORNER WELD (Ay -I 3 � 5 a FIXED MEETING RAIL SCREWED TOGETHER WITH OUTERFRAME 2 7/8"-{ 5 va EA 1718 HEAVY DUTY MEETING RAIL-1681 ALUMINUM 6063-T6 F��K 13/16 L PVC SASH STOP-6029 N1� WINDOWS & DOORS 1900 SW 44TH AVE. CALA, FLORIDA 34474 ITLE1 EXTRUSIONS! B.O.M.- LARGE MISSILE IMPACT R1nn P RAWN BY: AAA ATE' 08/14/2008 I PVC SINGLE HUNG 1 1.9 F.­ ­ .. CWS-3691 B r" 5OF7 PERIMETER SEALANT BYINSTALLER EXTERIOR FINISH — BY OTHERS SEALANT BEHIND FIN BYINSTALLER 1/21 SHEATHING BY OTHERS INSTALLATION ANCHOR, 410 W OOD ANCHOR W/NEOPRENEBACKED WASHER THRU SCREW SUPPORT [D] SEALANT UNDER SCREW HEAD BY INSTALLER 1/4' MAX. SHIM [B] ]/4_ MIN. EDGE DIST. 1 3l8° MIN. EMBEC /-2 BY WOOD BUCK BY OTHERS [A] 3!B' MIN. lL EDGE DIST. [D] 1 1n• MIN. EMBEDMENT [E] SILL SECTION NFIN THRU FRAME (WOOD) 1 318' MIN. EMBEDMENT [D] 2 BY WOOD BUCK BY OTHERS 1/4" MIN. EDGE DIST. [A] [E] 1/4' MAX. SHIM [B] INSTALLATION ANCHOR, #8 WOOD ANCHOR INSTALLATION ANCHOR, [E] #10 WOOD ANCHOR WNVASHERTHRU SCREW SUPPORT [D] 3/8' MIN. EDGE DIST. [D] 1 1/2' MIN. EMBEDMENT [E] 1/2° SHEATHING BY t .�.t. t �••. OTHERS { ti'•:'+: t:1•td+ti i°ti+r SEALANT BEHIND FIN BYINSTALLER PERIMETER SEALANT BYINSTALLER EXTERIOR FINISH BY OTHERS JAMB/HEAD SECTION 7 FIN THRU FRAME (WOOD) REFERENCE NOTES: [D] [A] SEE NOTE 10, BHT 1 FL P.E. No 58201 d �9 S STATE OF RIETARY AND 11/28/11 WRITTEN THE PERMISSION RMESSIONOFCUSTION CONTAINEDTOMWOIND WSYSTEMS,OIRNMTHIS DRAWING IS THE C.ISPROHLE EITHPROPERTY FOUiTHE ��iSD. #ONALEI [B] SEE NOTE 2&3, SHT 2 [C] SEE NOTE 4, SHT 2 ID] SEE NOTE 5, SHT 2 [E] SEE NOTE 6, BHT 2 WINDOWS & DOORS SW 44TH AVE. A, FLORIDA 34474 \LLATION DETAIL THRU FRAME W/ FIN - LARGE MISSILE IMPAC' 8100 RAWN : AA J ATE' 08/14/2008 L: CALE: G. O.: PVC SINGLE HUNG NTS CWS-36 EV. LETTER: BSHEET: 7 OF 7 INTERIOR FINISH SEALANT BETWEEN BUCK BY OTHERS 1 4' MIN. EMBEDMENT AND OPENING BY OTHERS [C] CONCRETEIMASONRY �•.,,• r BY OTHERS j . f 1/4" MAX. SHIM (MIN EDGE DIST.) „ , [B] [C] INSTALLATION ANCHOR, 3/16" DIA. • C � a .;'•'~ MASONRY SCREW WMASHER CONCRETEIMASONRY • • h' • • THRU SCREW SUPPORT BY OTHERS �• • :. D D . • •.er • 1 1/4• . • • . EXTERIOR FINISH D • D • D • D • (MIN EMBEDMENT) [C] 4 BY OTHERS —i •• . a. • 4 0•• PERIMETER SEALANT I BY BUCK BY OTHERS 2 1I2" A BY INSTALLER [ ] (MIN EDGE DIST.) • 4 • ; • 4 SEALANT BEHIND 184" MAX. SHIM [C] .4 4 4 FLANGE BY INSTALLER 4 •' SEE GLAZING DETAIL SHT. 3 1 318" MIN. EMBEDMENT— [D] 114' MAX. SHIM [B] BY D•D• 7/8" MIN E IST. t. D O�INSTALLATI R, CHO� • #10 WOOD ANCHOR D w/WASHERTHRU SCREW SUPPORT `ems D ID] 2 BY WOOD BUCK BY OTHERS IA1 SEALANT BETWEEN BUCK AND OPENING BY OTHERS — EXTERIOR FINISH HORIZONTAL SECTION FRAME(WOOD) - - ---SEALANT -UNDER SCREW- - - --- HEAD BY INSTALLER INSTALLATION ANCHOR, 3/16' DIA. MASONRY SCREW w/NEOPRENE BACKED WASHER THRU SCREW SEALANT BEHIND SUPPORT HIGH RISE SILL, OPTIONAL FLANGE BY INSTALLER [C] (SEE NOTES 2 & 3, SHEET 4) PERIMETER SEALANT 1/4' MAX SHIM SEE GLAZING BY INSTALLER [B] ♦ DETAIL SHT. 3 SEALANT UNDER SCREW EXTERIOR FINISH p ° • a,INSTALLATION ANCHOR, 3/16°DIA. HEAD BY INSTALLER BY OTHERS . s p •o o •p b D . 0 1 114" MIN. EMBEDMENT p SEALANT BEHIND [ I MASONRY SCREW w/NEOPRENE p- v v p o v 'p ;° p°1>e p v •p° D °• v D [C] FLANGE BY BACKED WASHER THRU SCREW INSTALLER i SUPPORT •pv D. o p D PERIMETER SEALANT - o ° D o p p•° p v p p• p p'° BY INSTALLER 1/4° MAX SHIM O � [B] [2�° MIN. EDGE DIST. EXTERIOR FINISH CONCRETE/MASONRY C BY OTHERS ALTERNATE PRECAST SILL DETAIL BY OTHERS \, SILL STOOL 6 FRAME (MASONRY) B UPDATED •r • I I . SEALANTBEHINDflip �� i 4 1 BY WOOD BUCK—� L FLANGE BY INSTALLER BY OTHERS EXTERIOR FINISH [A] BY OTHERS PERIMETER SEALANT PERIMI INSTALLATION ANCHOR, 3/16' DIA. BY INSTALLER BY INS ♦ MASONRY SCREW wMASHER HORIZONTAL SECTION ♦ THRU SCREW SUPPORT 8 FRAME (MASONRY) [C] - 1 ;r}i.'•.j: •D.Di I D•D . BY OTHERS LUCAS A. TURNER, FL P.E. 56201 A "•• ADDED ALT. FIN D• D` A•D D• 11111 • = D•D D, •D•D=•G ,\\I\ I111j I = D D • : D ,D . • �. D . > . p , •D D . D D .D . D • '•D`••• •• '• USE SOLID WOOD SUPPORTTO MAKE r ,,��y PNDREby TGriri ,nA ��,/���� �,.•L�.{GWVsz D, • • D • • • D' D . D . • • D • SILL LEVEL BY OTHERS ♦ CEN P' �,� SF•• :p2�'. D , .? � � • D • • • • D D : • D o • D • :•e • ' • v; No 58201 WDVDows & DOORS 1900 SW 44TH AVE. CONCRETE/MASONRY 2 112" t 1/4" (MIN. EMBEDMENT) [C] �Ir ; * ; �F CALA, FLORIDA 34474 TITLE: INSTALLATION DETAIL TI BY OTHERS (MIN EDGE DIST.) [C] STATE OF :4U SERIES: 8100 HIGH STRENGTH �• ,�4�F :,4 \_,�� STRUCTURAL VERTICAL SECTION GROUT BY OTHERS L� PROPRIETARYAND coPFtDENTl4L 11/28/11 INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF O R VD * `� rrrissfpj� MODEL: PVC SINGLE HUNG FRAME (MASONRY) PROHff�OUTHE WIINDWRIDOFW SYSTEMS, SSIN OF ANY DU TIO SYSTEMS, R ASIS WHOLET THE p ; E�G REFERENCE NOTES: [A] SEE NOTE 10, SHT 1 [B] SEE NOTE 2&3, SHT 2 [C] SEE NOTE 4, SHT 2 [D] SEE NOTE 5, SHT 2 S B 08/14/2008 1 Item# Part# Description Vendor Material 1 H-6031 IMain Fr., SH, wlFlg., PVC, Head MIKRON PVC 2 H-6031 Main Fr., SH, w/Flg., PVC, SIII MIKRON PVC 3 H-6031 Main Fr., SH, w/Fig., PVC, L. Jb. MIKRON PVC 4 H-6031 Main Fr., SH, w/Fig., PVC, R. Jb. MIKRON PVC 5 H-168 Heavy Duty, Meet. Rail, Fxd. Aluminum KEYMARK ALUM 6 H-6027 Sash Meet. Rail, PVC MIKRON PVC- -7 H-1497 Relnt Sash Meet, Rail KEYMARK ALUM 8 6004 Sash Bottom Ral SI a Rail PVC MIKRON PVC 9 S-1498 Reinf. S.B.R. S.S.R KEYMARK ALUM 10 S-6064 Glazing Bead, 718" MIKRON PVC 11 S-6013 Scm. Adapt., w/Nib, PVC, Horiz. MIKRON PVC 12 S-6014 Scm. Adapt., PVC, Vert. MIKRON PVC 13 S-6029 Sash Stop / Filler, PVC, Vert. MIKRON PVC 14 H-1699 Reinforcement, SBR KEYMARK ALUM 15 P-2190 Balance BSI 16 P-3059 Sash Cam, PVC M&M NYLON 17 P-3046 Take Out Clip 18 P-3783 Spring Lock, Impact, PVC INTERLOCK 19 P-3784 Spring Lock Keeper, Impact, PVC INTERLOCK 20 P-3215 Weep Coverw Flap NAM NYLON 21 5-6077 HD Fixed Meeting Rail Cover MIKRON PVC 22 P 4429 Wstp., 0.270 x .187 back FlnSeal, Gray ULTRAFA13 23 P-4638 #8 x 2-1/2 -P-F-mcTTr5ss, Type A, TEK 2 FASTENAL STEEL 25 P-4051W #8 x 1.250 Ph FH TEK, Wht. FASTENAL STEEL 26 P-3748W 5 Quad FH TEK, Whit. FASTENAL STEEL -27 -P-3342 aler, SM-5504 SCHNEE- 28 P-3752 , 1 2" Hole M&M NYLON 29 P-3438 52 or Purfect Glaze "H" VTemporary IKA/HENKE 30 P-3352 , 85 Dur., 1 8" x 5/8" x 2" Lg. FRANK LID RUBBER 31 P,3B81 bl. NFR DP) 32 P-3513 . logo33 Sash E 3 FOR GLASS TYPE 34 Fixed SEE PAGE 3 FOR GLASS TYPE 35 -1688 Highrise SII KEYMARK ALUM 36 P-3281 DuraSeal TRUSEAL 37 P-3113 Screw Supportfor PVC RUBBER TEAM 38 S-1577 Impact Hook KEYMARK ALUM 39 P-31 18 Keeper, Sweep Lock SULLIVAN STEEL 40 P-3541 x 1/2, Pan Head, TEK FASTENAL ZINC 1 -4 332 Sweep Lock SULLIVAN ZINCP-4633 Barrel Fastener FASTENAL STEEH-6026 E44 Main Fr., SH, w F n, P C MIKRON PVC H-6028 Sash, Bottom Rail MIKRON PVC S-1112 Glaze Bead (reinforcement) KEYMARK ALUM Lr:314" 1/16" 311166"" i 9 REINF. S.B.R./S.S.R. -1498 ALUMINUM 6063-T6 3 jL! tl 2 f�-- 3" -1 3/16" - SCREW SUPPORT-3113 .070" 711 10 PVC GLAZING BEAD-6064 21 3 PVC FRAME FLANGE-6031 PVC FRAME FIN-6026 2 3/1 3 16 1/16" 5/8° 1518° f-1 44 PVC SASH MTG. RAIL-6027 PVC SASH BTM RAIL-6028 0 3/16° 10 O 1116' 5 !7 8° I+ 1 5116' 38 IMPACT HOOK -1577 (ALUM 6063-T6) " ro 7EY, 6" 3 1/6" REINF. SASH MTG. RAIL-1497 ALUMINUM 6063-T6 � HIGH RISE SILL -1688 ALUMINUM 6063-T6 PROPRIETARY AND CONFIDENTRI. 11/28/11 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS, INC. IS PROHIBITED. �1 3/16" 1116" nr"I� 8" e PVC SASH SIDE RAIL-6004 11/8"1 F 1/16" 5/16' vi PVC SCREEN SUPPORT - 6014 1/16" 1 " 11 r-1 3/4• ---"-I .D45' 1 5/16' I 1 L-F--2 3/16°—�I PVC HD MTG RAIL COVER-6077 314" 14 15/16" I �j 1/16' �_ I� REINF. SASH BTM RAIL-1699 ALUMINUM 6063-T6 LCORNER WE ` A IDES 3 LE�l W$ FIXED MEETING RAIL SCREWED TOGETHER WITH OUTERFRAME 2 7/8"—�{ 5 FD 1 718" HEAVY DUTY MEETING RAIL-1681 ALUMINUM 6063-T6 1 3/8' 1l16" 13/16 13 PVC SASH STOP-6029 v 1 No 58201 1900 SW 44TH AVE. CALA, FLORIDA 34474 ro' :grg TITLE: EXTRUSIONS / B.O.M.- LARGE MISSILE IMPACT STATE OF :40- �0T"• P,: _�`�� 8100 RAWN ' AAJ ATE: 08/14/2008 a R 10.��`,�� MODEL: PVC SINGLE HUNG CALF: 1 2 G. NO.: CWS-36! icy INpN illll, ` EV. LETTER: B HEET: 50F7 EXTEF_. SECTION A -A (SEE NOTE 3) 1688) '7) TEI fEF SECTION B-B (4632) SECTION C-C ALT. FIN FRAME WITH SWEEP LOCKS (SEE NOTE 2) PROPRIETARYAND CONFIDENML 11/28/11 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS, INC. IS PROHIBITED. ��._ r.:3R Y-`" d + SILL RISER MAX. POSITIVE DP NONE +67.5 1688 +100.0 NOTES: 1. ITEMS 13. 15, 17, 21, 23, 27, 28, 31, 32, 36 ARE NOT SHOWN FOR CLARITY. 2. IF SILL RISER IS NOT USED, SWEEP LOCKS (4632) ARE REQUIRED. SWEEP LOCKS MAY BE USED ON FIN OR FLANGE APPLICATIONS. (SEE SECTION C-C) 3. IF SILL RISER IS USED, IMPACT HOOKS (1577) ARE REQUIRED. SILL RISER MAYBE USED ON FIN OR FLANGE APPLICATIONS. (SEE SECTION A -A) B _I UPDATED PER 2010 FBC 11/11/2011 LUCAS A. TURNER. FL P.E. 682011 A I ADDED ALT. FIN INSTALL PAGE 1 05/19/2011 6ARWMOWS&DOORS SW 44TH AVE. A, FLORIDA 34474 SECTION VIEWS - LARGE MISSILE IMPACT 8100 AAA ATE. 08/14/2008 L. PVC SINGLE HUNG SCALE! NTS G. O.: CWS-36 REV.LETTER: BSHEET: 4 OF 7 IF FULL SIZE FIXED LITE 7/8" OVERALL INSULATED LAMINATED GLASS 3/16" ANNEALED orTEMPERED (TEMPERED REQ'D IN HVHZ) 3/8" AIRSPACE 5116" LAMINATED 1/8" ANNEALED .090" SENTRY GLASS IONOPLAST INTERLAYER 1/8" ANNEALED '29 SIKAFLEX 552 OR PURFECT GLAZE "H" 1/2" GLASS BITE FULL SIZE SASH LITE 718" OVERALL LAMINATED GLASS"' 3/16" ANNEALED or TEMPERED (TEMPERED REQ'D IN HVHZ) 3/8' AIRSPACE 5116" LAMINATED 1/8" ANNEALED .090" SENTRY GLASS IONOPLAST INTERLAYER _ 1/8" ANNEALED SIKAFLEX 552 OR PURFECT GLAZE "H" 1/2" GLASS SITE ol Pp10RE W - sle ���GPc'•� "G E N 3h." t" No 58201 ecc 90 srarE OF :�11i , PROPRIET/ : ,' �E�, INFORMATION THE NDA NOTANY REPDOR AS WITHOUT THHE iS /ONALG' WW N S SILL RISER MAX. POSITIVE DP_ NONE +67.5 1688 +100.0 I` —,-A" WINDOWS & DOORS 1900 SW 44TH AVE. CALA, FLORIDA 34474 TITLE: ❑P CHART /GLAZING -LARGE MISSILE IMPACT 8100 R "Y AAJ t' 08/14/2008 MODEL: PVC SINGLE HUNG 'ALE: 1:1 G. O': CWS-369 EV. LETTER: 6 HEET: A r)P 7 10" MAX O.C. (THRU FRAME) 6" MAX. (THRU FRAME) (SHT 4) 6" MAx. A (THRU FRAME) I 9" MAX. O.C. I O (THRU FRAME) I I I B7L 3° 3" 7" I I i � I NOTE 2 B (SHT4) INSTALLATION ANCHORS (SEE NOTE 4) 3" MAX (THRU FIN) 6' MAX O.C. 3" MAX (THRU FIN) (THRU FIN) /-T DETAIL A O SEE NOTE 2 INSTALLATION ANCHORS (SEE NOTE 5) 7° 5" 3" THRU FIN INDICATOR THRU FRAME INDICATOR ii I I X I I /� (SHT4) (T MAX O.C. (THRU FRAME) AFI� I I- /� C' '�f"' I 1 ( O A 1 6° MAX. (THRU FRAME) 1. ANCHOR LAYOUT - (FLANGE) 10" MAX O.C. (THRU FRAME) NOTES: THRU FRAME (MASONRY OPENING) ANCHOR LAYOUT - (FIN) THRU FRAME (WOOD OPENING) 1. INSTALL ONE ANCHOR AT EACH LOCATION. SILL ANCHOR SPACING SAME AS HEAD. 2. SHIM AS REQ'D AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16° IS PRESENT. 3. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 4. 3/16" DIA. ELCO ULTRACON MASONRY ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN. EMBEDMENT OF 1 1/4" INTO MASONRY THRU FRAME OR THRU 1 BY WOOD BUCK INTO MASONRY. A MINIMUM EDGE DISTANCE OF 2 1/2" SHALL BE ACHIEVED IN ANY DIRECTION. 5. #10 WOOD SCREW ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN. EMBEDMENT OF 1 3/8" INTO 2 BY WOOD BUCK. A MINIMUM EDGE DISTANCE OF 7/8" SHALL BE ACHIEVED IN ANY DIRECTION IN FLANGE FRAME INSTALLATION. IN FIN FRAME INSTALLATION THRU THE FRAME, THE MIN. EDGE DISTANCE SHALL BE 3/8° IN ANY DIRECTION. 6.48 WOOD SCREW ANCHOR THRU FIN MUST BE NO LESS THAN 1"AWAY FROM THE MAIN THRU FRAME ANCHOR WHEREVER NECESSARY, ELSE FOLLOW THE REQUIRED SPACING, A MINIMUM EDGE DISTANCE OF 1/4" SHALL BE ACHIEVED IN ANY DIRECTION. 7. SEAL CORNERS WITH SMALL JOINT SEAM SEALANT. B UPDATED B. ALL INSTALLATION ANCHORS MUST BE MADE OF OR COATED WITH A CORROSION RESISTANT MATERIAL. DISSIMILAR MATERIALS OR MATERIALS LUCAS A. TURNER, FL P.E. 58201 A ADDED ALT IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTIONS. 9. INSTALLATION ANCHORS SHALL BE IN OANCE TANCHORITH MANUFACTURERS INSTRUCTIONS, AND ANCHORS SHALL •......f�GNOT BE USED IN SUBSTRATES WITH STRENGTHSLESS THAN THEMINMMSTRENGTH SPECIFIED BELOW •s.. 1" MIN. (SEE NOTE 6) DETAIL A 0 FBC 10. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIAL WITH THE FOLLOWING PROPERTIES: -% . `*- kc-,�0, WINDOWS &DOORS A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.55 (SOUTHERN PINE OR GREATER) + -4 No 58201 t,70 1900 SW 44TH AVE. B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3.200 PSI. * * ; * 6 CALA, FLORIDA 34474 C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). Q TITLE, :9 STATE OF ; ltr+' ANCHOR SCHEDULE & NOTES - LARGE MISSILE IMPACT 11. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS IN ACCORDANCE WITH 0 O .• !V ATE: 08/14/2008 A THE CURRENT VERSION OF THE FOLLOWING REFERENCE DOCUMENTS ' • A, P..' Z' Q 8100 AAJ FMAIAAMA 1 OD (FIN WINDOWS), FMA/AAMA 200 (FLANGE WINDOWS), PROPRIETARY AND CONFIDENTIAL 11/28/11 �!!H'C `'* ; OR 10.• G�••` MODEL: CALF: G. o.: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM ♦ SS C: �'► PVC SINGLE HUNG NT$ CWS-369 FMAANDMA 25D (BOX WINDOWS), FMA/AAMAANDMA 300 (EXTERIOR DOORS). WINDOW SYSTEMS, IN PERMISSION C.OF ANREPRODUCTION IN PART Y WINDOW SYSTEMS, OASIS WHOLE HO E WITHOUT THE !!!!! �Of\jAi ����� EV. LETTER: BSHEET: 2OF7 SINGLE HUNG ELEVATION (LARGE MISSILE IMPACT) 73 1 /4" V MAX. OVERALL FLANGE HEIGHT 72" MAX. UNIT HEIGHT TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS .......... 1 ANCHOR SCHEDULE & NOTES...............2 DP CHARTS & GLAZING DETAIL.............3 SECTION VIEWS.......................................4 EXTRUSIONS & B.O.M ..............................5 INSTALLATION DETAIL .........................6&7 — 53 1/4" MAX OVERALL FLANGE WIDTH 52" MAX. UNIT WIC -48 5116" GLASS DI O I II II G3 LASS X I IIII II DLO` — 453W — GLASS DLO 49 9H 6• MAX. SASH WIDTH DESIGN PRESSURE RATING il t100.0 W/ SILL RISER PVC IMPACT REQUIREMENT: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA CODE, CURRENT EDITION 2. GLAZING OPTIONS: (SEE SHEET 3) 3. CONFIGURATIONS: "O/X". 4. DESIGN PRESSURE RATING: -NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E 1300. -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSU GLASS TABLES ASTM E 1300. 5. ANCHORAGE: THE 33 113% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEETS 6 & 7 FOR ANCHOR DETAIL, WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 6. PRODUCT APPROVED FOR IMPACT RESISTANCE. THE IMPACT SWEEP LOCKS ARE INTENDED TO BE LEFT UNLATCHED DURING NORMAL OPERATION OF THIS PRODUCT, BUT MUST BE ENGAGED PRIOR TO EXPOSURE TO HURRICANE WINDS AND FLYING DEBRIS. 7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT USED AT FIXED MEETING RAIL AND JAMB. 8. REFERENCE TEST REPORT: NCTL-210-3531-1, NCTL-210-3531-IA 9. SERIES / MODEL DESIGNATION SH-8100. 10. lx OR 2x WOOD BUCK OR STUD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. BUCK -AND FRAMING -IS RESPONSIBILITY--OF-ARCHITECT-OR ENGINEER OF RECORD. -- 11. THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING: X = OPERABLE SASH, O = FIXED SASH 12. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR LOCATION. -7f No 58201 :- : 1900 SW 44TH AVE. CALA, FLORIDA 34474 Lucas A. Tumer, P.E. 2011-11-29 00:57-05:00 �n' 2' ITLE: GENERAL NOTES & ELEVATIONS - LARGE MISSILE IMPACT z� 9 S STATE OF : &J SERIES: RAWN ATE: 08/14/2008 PROPRIETARYAND CONFIDENTIAL 11/28/11 ,,��0��•'0< OR iV N2�, MODEL: 8100 CALE: . AAJ WG. NO.; THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM �i, `S'S •"'•••" l�� \, PVC SINGLE HUNG NT$ CWS-361 WINDOW WRITTEN PERMISSION O�STOM WINDOION IN PART W SYSTEMS,,IINAS IS PROD �D OUT THE �i�, �Oryp� ����� EV. LETTER: B HEFT: 1 OF 7