HomeMy WebLinkAboutSEWAGESTATE OF FLORIDA
:....
b DEPARTMENT OF HEALTH.
' ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
-!wCoo WE
APPLICANT: Scherer Management CO
AGENT: HOmetec.Contractors Inc
PROPERTY ADDRESS:
LOT: 36
SUBDIVISION:
Dr Fort Pierce, FL
ITEMS ARE
TANK INSTALLATION
[01] TANK SIZE [
(02] TANK MATERIAL
[031 OUTLET DEVICE
[04] MULTI-CHAMBEREI
[05j OUTLET FILTER
.[06] LEGEND' 1 70-
[071 WATERTIGHT
t08] LEVEL
[09] 'DEPTH TO LID
DRAINFIELD INSTALLAT]
[10] AREA [i
[111 DISTRIBUTION
BLOCK: 67'
ID#.; <34o2-6)9-0214=0006
p,PPLICATION :#.: AP1
293034
PERMIT #.:58=SF-161,1864
,DOCUMENT # : FI119587.6 .
DATE PATD.05/31./2018
FEE PAID 65; 0.0
RECEIPT #56-PIb-3573197
TN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRFx:1r:L'•
1090:00 (21 _
Polyethylene
Polylok, PL-68
3A1DC4 2.
670 [21 SQF'T
BOX HEADER X
[ 12 ] NUMBER F DRAINL,INES 1, 9.00 2:
[131 DRAINLINE SEPARATION
[141 DRAINLENE SLOPE
[151 DEPTH/OF COVER
[16] ELEVATION [ ABOVE / .BELOW IBM 1:00
[171 SYSTEM LOCATION
[18] DO/SING PUMPS
[19] AGGREGATE SIZE
[201 AGGREGATE EXCESSIVE FINES
[21:] /AGGREGATE DEPTH
FILL// EXCAVATION MATERIAL
[ ] [223 FILL AMOUNT
[ ] [231 FILL TEXTURE
[ ] [2/4] EXCAVATION DEPTH
[ ] [i25] AREA REPLACED
[ ] /[2'6] REPLACEMENT MATERIAL
,00ments: Comments are on page 2.
[ APPROVED / DISAPPROVED ]:
SETBACKS
[ ]
[27.]
SURFACE WATER
ET
[ ]
[2e]
DITCHES 15
FT
[2SQ
PRiVATR WELLS
FT
[301
PUBLIC WELL'S
FT
[ ]
[311
IRRIGATION WELLS
FT
[ ]
[32]
POTABLE WATER 1,0
FT
[ l
[33.1
BUILDING FOUNDATIQNS 6
FT
[ j
[.34]
PROPERTY LINES 12
FT
[ ]
1351,
OTHER
FT
FILLED / MOUND. SYSTEM
]
[36]
DRAINFIELD COVER
[37']
SHOULDERS
]
[38]-
SLOPES
[ ]
['3'9]
STABILIZATION 07/10/2018
ADDITIONAL INFORMATION
[ 1
1401
UNOBSTRUCTED AREA
[41]
STORMWATER RUNOFF
]
[421
ALARMS
[ ]
[431
MAINTENANCE AGREEMENT
[ ]
[44]
BUILDING AREA.
[ ]
[4.5]
LOCATION CONFORMS WITH SITE PLAN
[, ]
[46]
FINAL SITE GRADING
[ 1
[4'7]
CONTRACTOR Jeff Nelson (Jeffrey'Nelson'Se
[ ]
(48.1
OTHER INFILTRATOR Quick4 Plus.EQ36 LP
ABANDONMENT
[ ]
[0]
TANK PUMPED
[ j
[50.],
TANK CRUSHED & FILLED /
St. "Lucie CHD
I.Dian May (Floilda Department of Health
FINAL SYSTEM I APPROVED / DISAPPROVED
Environmental Specialist II Bria Ingram (ENVIRONN
/DH
Explanation of Violations on following page)
4016, 08109 (Obsoletes all previous editions which may not be used)
corporated; 64E-6.003, PAC
EH Database v 1.0.1 AP1293034 EID1611864
Permitting
C+- I i Iri'm
(1IE
r
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
N I WE, I
Violation Number Comment
Comments
APPLICATION #:AP1293034
-PERMIT #:56-SF-16.11864
DOMENT # : FI 1195876
DATE PAID..05/31/20.1'8
FEE PAID:65.00.
RECEIPT #:5&P'1D-3573197
The system is sized for 4 bedrooms: with a maximum occupancy of 8 persons'(2 per bedroom), for a total .estimated flow of 400
New ST and drainfield installed 8x7 chambers long. Drainfield does not meet the minimum sizing criteria. System not ok to cover.
No other violations observed. Contractor notified by phone about failing inspection and re -inspection fee:
Drainfield has been increased In size and installed 7x7 chambers.long, 1xe chambers long and 1x5 chambers long for a total of 9•
drainlines. System ok to cover, contractor notified by phone. Final required for mound system and' final site grading.
Final system approved. Contractor and building emailed final approval.
DHI',4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC
EH Database v 1.0.1 AP1293034 EID1611864
Page 2 of 3
APPLICANT: Scherer Management Co
AGENT: Hometec Contractors Inc
PROPERTY ADDRESS' 5601 Hickory Or' Fort Pierce, FL 3498
'T1 APPLICATION #.: P1293034
4" STATE OF FLORIDA PERMIT #.:561SF-161.1864
any � �
DEPARTMENT OF HEALTH
DOCUMENT # : FI 119587.6 .
ONSITE SEWAGE TREATMENT AND SXSTEM
CONSTRUCTION INSPECTION AND IW"JEItERCEIVEME
'
RECE
JUL 12 2018
PAID : 05/31 /201.8
PAID :' 65'.0.0
P.T #:56-PID-3573197
LOT: 36
SUBDIVISION:
BLOCK. _
Indian River Estates ID#.. 3402-609-0214=0005
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTEOR RULE AND MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
[ ]
[01]
TANK SIZE [1] 1090.00 [21
[
1
[27]
SURFACE WATER
FT
[ ]
[021
TANK MATERIAL Polyethylene
[
]
[281
DITCHES 15
FT
[ ]
[031
OUTLET DEVICE
[
]
[.291
PRIVATE WELLS
FT
[ ]
[041
MULTI -CHAMBERED [ Y N ]
[
]
[301
PUBLIC WELLS
FT
[ ]
[.05]
OUTLET FILTER Polylok PL-68
[
]
[311
IRRIGATION WELLS
FT
[ ]
[061
LEGEND 1'. 70-143-11DC4 2.
[
]
[321
POTABLE WATER 10
FT
[ ]
(071
WATERTIGHT
[
]
[331
BUILDING FOUNDATIONS 6
FT'
[ ]
[081
LEVEL
[
]
[.34]
PROPERTY LINES 12
FT
[ ]
[09]
DEPTH TO LID
[
]
1353
OTHER
FT
DRAINFIELD INSTALLATION
FILLED / MOUND SYSTEM
[ ]
[101
AREA [1] 679 [21 SQFT
[
]
[361
DRAINFIELD COVER
[ ]
[111
DISTRIBUTION BOX HEADER X
[
]
[371
SHOULDERS
[ ]
[121
NUMBER OF DRAINLINES 1, 9_00 1
[
1
[381
SLOPES
[ ]
[131
DRAINLINE SEPARATION
[
]
[391
STABILIZATION 07/10/2018
[ ]
[141
DRAINLINE SLOPE
[ ]
[151
DEPTH OF COVER
ADDITIONAL;INFORMATION
[ ]
[161
ELEVATION [ ABOVE / .BELOW ]BM 1.00
[
1
[401
UNOBSTRUCTED AREA
[ ]
[171
SYSTEM LOCATION:
[
]
[411
STORMWATER RUNOFF
[ ]
[18]
DOSING PUMPS
G•
]
[421
ALARMS
[ ]
[19]
AGGREGATE SIZE
['
]
[431
MAINTENANCE AGREEMENT
[ J
[201
AGGREGATE EXCESSIVE FINES
[
]
[441
BUILDING AREA
[ ]
[211
AGGREGATE DEPTH
[
]
[45]
LOCATION CONFORMS WITH .SITE PLAN
[
]
[46]
FINAL SITE GRADING
FILL / EXCAVATION MATERIAL
I
]
[47]
CONTRACTOR Jeff Nelson (Jeffrey�Nelson:Se
[ ]
[22.] FILL AMOUNT
[
]
[4e]
OTHER INFILTRATOR Quick4 Plus EQ36 LP
[ ]
[231 FILL TEXTURE
[ ]
[24] EXCAVATION DEPTH
ABANDONMENT
[ ]
[251 AREA REPLACED
[
]
[491
TANK PUMPED
[ ]
[261 REPLACEMENT MATERIAL
[
]
[501
TANK CRUSHED &.FILLED
Comments: Comments are on page 2.
CONSTRUCTION [ APPROVED / St. Lucie' CHD DATE. 06/01/2018
DISAPPROVED 1 ° Env ro ental Specialist I Dian May (Florida Department"of Health
FINAL SYSTEM [ APPROVED / DISAPPROVED ]: t. Lucie CHD DATE: 07/10/2018
Envleonmental Specialist It Briar Ingram (ENVIRONMENTAL HEALTH)
(Explanation of Violations on following page)
DE 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, PAC Page 2 of 3
EH Database v 1.0.1 AP1291034 EID1611864
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
Violation Number Comment
i
APPLICATION #: AP'1293034
PERMIT #:56'-SF-1611864
Docui-= , # : F11 195876
DATE PAID - 05/31 /201'8
FEE PAID :65'.00.
....rom .4—riR—P1D-3573197
V vccuueu c� i
The system is sized for 4 bedrooms: with a maximum occupancy.of 8 persons'(2 per bedroom), for a total .estimated flow. of 4Q0
gpd•
New ST and drainfield',installed 8x7 chambers long. Drainfield does not.meet the minimum sizing criteria. System not,ok to.cover.
No other violations observed. Contractor notified by phone.about:failing inspection and re -inspection fee.
Drainfield has been Increased in size and installed 7x7 chambers,long, 1z6 chambers long, and'1x5 chambers long for a total of 9
drainlines. System ok to cover; contractor notified by phone: Final required for mound system and'final site grading.
Final system approved. Contractor and building.emailed -final approval.
DH 4016, 08109 (Obsoletes all previous editions which may not be used)
Incorporated; 64E-6,.0031".FAQ
Page 2 of 3
EH Database v 1;0.1 AP1293034 EID1611864