Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BIEHL ADDITION �CNN Builder Name: f eet:. 124 QUEEN ANN COURT ��,y UU Permit Office: NOV _ 6 2015 pity, State, Zip: FT. PIERCE, FL, 34949 Permit Number: wner: ��Ler@Coo* Jurisdiction: Public Works Design Location: FL, Fort Pierce St. Lucie County, f=L 1. New construction or existing Addition 9. Wall Types (540.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 540.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 0(0) d. N/A R= ft2 10. Ceiling Types (200.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 200.00 ft2 6. Conditioned floor area above grade (ft2) 200 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(37.8 sqft.) Description Area a. U-Factor: Sgl, U=0.65 37.78 ft2 SHGC: SHGC=0.25 ft2 � 12. Cooling systems kBtu/hr Efficiency b. U-Factor: N/A a. Central Unit 9.0 SEER:21.00 SHGC: c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 10.9 HSPF:10.00 SHGC: Area Weighted Average Overhang Depth: 1.500 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems -None required a. Cap: N/A 8. Floor Types (200.0 sqft.) Insulation Area EF: 0.000 a. Slab -On -Grade Edge Insulation R=0.0 200.00 ft2 b. Conservation features b. N/A R= ft2 c. N/A R= fI2 15. Credits None 0.189 Total Proposedi Modified Loads: 8.02 PASS Glass/Floor Area: Total Baseline Loads: 11.29 a ' Thereby certify that the plans and specifications covered by Review of the plans and O�SrtiE STA?� "this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. p PREPARED I Before construction is completed - -- this building will be inspected for compliance with Section 553.908 �' a _ .1 hereby certify that this building, as designed, is in compli nce Florida Statutes. COD with the Florida En Code. WE OWNER/AGEN BUILDING OFFICIAL: DATE: 21 dc v DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. t. _ COP' 101712015 10:44 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Pa e 1 of 4 Cn17M Rdnr._')nl d PROJECT Title: Building Type: Owner: # of Unds: Builder Name: !amit Office: ;:I f risdiction: Family Type: New/EAsting: Comment: BIEHL ADDITION Bedrooms: 0 User Conditioned Area: 200 Total Stories: 1 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Single-family Addition Address Type: Lot# Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address 124 QUEEN ANN COU ST. LUCIE COUNTY FT. PIERCE, FL, 34949 CLIMATE / V Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blocki 200 1800 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 200 1800 Yes 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 60 ft 0 200 ftz 1 0 0 ROOF / V # Type Roof, Gable Roof Materials Area � Area Color Solar Absor. SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) 1 Hip Composition shingles 217 ftz 0 ftz Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 200 ftz N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 200 ftz 0.11 Wood 10/7/2015 10:44 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software 9 F[1RM Rdnr,_7n1 A WALLS # Omt Adjacent Space 10 Wall Type Cavity Width Height Sheathing Framing Solar Below _ 1 _ 2 _ 3 4 N E S W Exterior Concrete Block - Ext Insul Main Exterior Concrete Block - Ext Insul Main Exterior Concrete Block - Ext Insul Main Exterior Concrete Block - Ext Insul Main 4.09999 10 9 90.0 ft2 4.09999 20 9 180.0 ft2 4.09999 10 9 90.0 ftz 4.09999 20 9 180:0 ft2 0 0 0 0 0 0.75 0 0.75 0 0.75 0 0.75 0 0 0 0 WINDOWS Orientation shown is the entered, Proposed orientation. # Wall Omt ID Frame Panes NFRC Overhang U-Factor SHGC Area Depth Separation Int Shade Screening 1 2 N 1 Metal Low-E Single Yes N 1 Metal Low-E Single Yes 0.65 0.25 17.8 ft2 1 ft6 in 0.65 0.25 20.0 ft2 1 ft6 in 3 ft0 in 3 ft0 in Drapes/blinds Drapes/blinds None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000286 150 8.23 15.49 .2087 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:10 10.9 kBtu/hr 1 Ductless COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 21 9 kBtu/hr 270 cfm 0.8 1 Ductless SOLAR HOT WATER SYSTEM FSEC Cert # Company Name System Model # Collector Model # Collector Area Storage Volume FEF ft2 1017/201510:44 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 TEMPERATURES Programable Thermostat: None Ceiling Fans: CoolingJan HeatinHJan Feb HFeb Mar Mar ] Apr [ ] Apr r [ ] May ] May jX]] Jun [ j Jun Jul Jul rl [ ] AuSep jX] Augrl Se Oct MOct Nov Nov HX Dec Dec Ventin Jan Feb X Mar [[XXjj A r [[I ] Ma [ ]] Jun Jul [ ] Aug Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 10/7/201510:44 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: BIEHL ADDITION Builder Name: Street: 124 QUEEN ANN COURT Permit Office: City, State, Zip: FT. PIERCE, FL, 34949 Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow Cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelop ,� b r sealed to the sub -floor or drywall. i Fireplace An air barrier shall be installed on fireplace walls. Fireplaces h I a . � t", ' ~ ' gasketed doors 10/7/201510:45 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD I ESTIMATED ENERGY PERFORMANCE INDEX* = 71 The lower the EnergyPerformance Index, the more efficient the home. 124 QUEEN ANN COURT, FT. PIERCE, FL, 34949 1. New construction or existing Addition 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 540.00 ftz b. N/A R= ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 0(0) d. N/A R= ftz 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 200.00 ftz 6. Conditioned floor area (ftz) 200 b. N/A R= ftz c. NIA R= ft2 7. Windows•" Description Area 11. Ducts R ftz a. U-Factor: Sgl, U=0.65 37.78 ftz SHGC: SHGC=0.25 b. U-Factor: WA ftz SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a. Central Unit 9.0 SEER:21.00 SHGC: d. U-Factor: N/A ftz 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 10.9 HSPF:10.00 Area Weighted Average Overhang Depth: 1.500 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems - None required Ca N/A p' a. Slab -On -Grade Edge Insulation R=0.0 200.00 ftz a. EF: b. N/A R= ftz b. Conservation features c. N/A R= ftz 15. Credits None w I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. , Builder Signature: - Date: Address of New Ho O� City/FL Zip: ~Oq�y ZHiii STgTFO.D Saar'. *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/7/2015 10:45 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Softw , COP 1 P - wrightsoft® Project Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@ADL.COM For. BIEHLADDITION 235 QUEEN ANN COURT, FT. PIERCE,FL 34949 Notes: .De -sign Information Weather. Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 4151 Btuh Ducts 849 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 5001 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 Heating Cooling Area (ftz) 200 200 Volume (ft3) 1800 1800 Air changes/hour 0.61 0.32 Equiv. AVF (cfm) 18 10 Heating Equipment Summary Make Trad e Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Job: Date: Oct 07, 2015 By: Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 3700 Btuh Ducts 1319 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 4768 Btuh Latent Cooling Equipment Load Sizing Structure 801 Btuh Ducts 348 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 1149 Btuh Equipment total load 5917 Btuh Req. total capacity at 0.70 SHR 0.6 ton Cooling Equipment Summary Make MITSUBISHI Trade Cond MSZ-GE09NA-9 Coil MUZ-GE09NA-9 AHRI ref 80 AFUE Efficiency 0 Btuh Sensible cooling 0 Btuh Latent cooling 0 OF Total cooling 307 cfm Actual air flow 0.061 cfm/Btuh Air flow factor 0 in H2O Static pressure Load sensible heat ratio 13.6 EER, 21 SEER 6300 Btuh 2700 Btuh 9000 Btuh 307 cfm 0.061 cfm/Btuh 0 in H2O 0.81 Calculations approved byACCAto meet all requirements of Manual J At= * wrightsoft' RightSuite® Universal 2015 15.0.19 RSU08101 ...cslDocuments\Wrightsoft WVACIBIEHLADDITION. rup Calc= MJ8 Front Door faces: S wrightsoft® Ri ht-M Worksheet Job: Entfre House Date: Oct 07, 2016 By: QUICK CALCS, INC. 317 ST. LUGE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466.6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House CRAFT ROOM 2 Exposed wall 30.0 ft 14.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 10.0 x 14.0 ft 5 Room area 200.0 ftZ 140.0 ftZ Ty Construction U-value Or HTM Area (ftZ) Load Area (ftZ) Load number (Btuh/ft *F) (Btuh/ftZ) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 '•W 13A-4ocs 0:143 i e - 4.00 2.56 180 .142 566 361 125 88 3-51 223 1013-m 1.450 a 40.60 46.84 19 0 782 902. 19 0 782 . 902 G 4A5.2om 0:770 a 21.56 47.10 .19 0 410 895 ., • . 19 ,: ... 0 410 895 W 13A-4ocs 0.143 4.00 2.55 90 90 _ 360 229 0 0 0 0 11 'P 12C-Osw '0.091 _s - 2.55 1:28 180 • 180 4,% -, 231 126 ` 126, 321 162 C 16B-30ad 0.032 - 0.90 1.68 200 200 179 336 140 140 _ 125 235 F 22Atpl: 0.989 - 27.69 0.00., ' '200. 30 :831 0'... 140 • 44 388 0 6 c) AED wcursion 128 128 Envelope loss/gain 3588 3082 2377 2545 12 a) Irriiltration 563 158 263 74 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 4151 3700 2840 3079 Less external load 0 0 0 0 Less transfer 0 0 0 0 14 Redistribution Subtotal 0 4151 0 3700 0 2640 0 3079 15 Duct loads 20% 36% 849 1319 20% 36% 540 10971 Total room load W01 1 5019 3180 4177 Air required (cfm) 307 307 195 255 Calculations approved by ACCA to meet all requirements of Manual$t Ed. F N wri htsoft" 10:46:07 9 RlghtSuitec® Universal 2015 15.0.19 RSU08101 Page 1 I&K ...cs\Documents\Wrightsoft WAC\BIEHLADDITION.rup Calc = MJ8 Front Door faces: S � � - wrightsoft° Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKC4LCS@AOL.COM Job: Date: Oct 07, 2015 By: 1 Room name CLOSET 2 Exposed wall 16.0 ft 3 Room height 9.0 ft heat/000l 4 Room dimensions 10.0 x 6.0 ft 5 Room area 60.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/ft'-°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gress WP/S Heat Cool Gross N/P/S Heat Cool 6 WI 13A flocs D.143 a ''' 4:00 .2.55 54 54.' 216 ' , 137 ; - 106-m 1.450 a 40.80 46.84 0 0 0 0 L—G 4A5-2om 0.770., a .21.56 . 47.10 . 0 0 0 0' W 13A-4ocs 0.143 s 4.00 2.55 90. 90 360 229 11 P 12C Osw 0 091, ; ., 2:55 ; .. 1:28 : ,..: 54 �54 ' . ,138 . ... -. 69 . C 16830ad 0.032 _ 0.90 1.68 60 60 54 101 F 22A-tpl 0.989. - 27.69 - . 0.60 ' 60 _16 443 0 6 c) AED ecursion 0 Envelope loss/gain 1 1211 537 12 a) Infiltration 300 84 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 1511 621 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 1511 621 15 Duct loads 20% 36°% 309 221 Total room load 1 1821 1 842 Air required (cfm) 1121 52 Calculations approved byACCA to meet all regt A+ wrightsoft°° RightSuite® Universal 2015 15.0.19 RSU08101 IM ...cs\Documents\Wrightsoft HVAC\BIEHLADDITION. rup Calc= MJS Front Door faces: S ON