Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRODUCT DATA SHEET
• SCANN EcoTouch PINK FIBERGLAS Insulation BY with PureFiber° Technology INNOVATIONS FOR LIVING' Loeika Description Owens Corning EcoTouch' Insulation with PureFiber5 Technology is flexible insulation and is made in R-values from I I to 38: EcoTouch" Insulation is available plain, or faced with either a kraft or foil vapor retarder. The product is manufactured in thicknesses from 3%2" to 12." Uses EcoToucH" Insulation can be used in a wide range of exterior wall and roof/ceiling applications, The product can be installed in wood or metal framing cavities, or can be installed between furring strips. Product Data Sheet Surface Burning Characteristics/Building Code Construction Classification Produets Flame Spread Smoke Developed ICC Unfaced <25 <50 All Types Foil Faced <75 <150 III, IV, V Kraft Faced N/R N/R III, IV, V EcoTouch" Insulation complies with ]CC (International Building Code), model code requirements for building construction types listed above. Kraft and standard foil facing will burn. Do not leave exposed. Facing must be installed in substantial contact with an approved ceiling, floor or wall material. Keep open flame and other heat sources away from facing. Do not place insulation within 3" of light fixtures or similar electrical devices unless device is labeled for contact with insulation. Use only unlaced insulation between wood framing and masonry chimneys. Do not use insulation in spaces around metalIIchimneys, fireplaces, or flues. EcoTouch" Unfaced insulation is considered non-combustible by model building codes. Flame Spread 25 products are flame spread rated and can be left exposed where codes allow. See package for warnings, fire hazard and installation instructions, or call 1-800-GET-PINKP Duelto the potential for skin irritation, EcoTouch'" Unfaced Insulation should not be used for exposed applications where it will be subject to human contact. I Features and Benefits Excellent Thermal Control With the range of R-values and thicknesses available, EcoTouch"" Insulation can meet most thermal specifications with ease, The R30C and R38C provide excellent thermal performance in the limited space of cathedral ceilings. Effective Acoustical Control EcoTouch' Insulation enhances interior noise control by improving the Sound Transmission Class (STC) of walls and floor/ ceiling assemblies. Long Term Performance EcoTouch'°' Insulation is dimensionally stable and will not slump within the wall cavity. Due to its inorganic fibers, EcoTouch' Insulation will not rot or mildew' and is noncorrosive to steel, copper, and aluminum. Easy Installation EcoTouch' Insulation is easy to handle and install. Sized for installation in either wood or metal stud construction, EcoTouch' Insulation can either be friction -fit or stapled into place. Trimming and fabrication can be done with an ordinary utility knife and is easily installed into odd -shaped cavities and small spaces. With less dust than other fiberglass insulation products, EcoTouch'" Insulation has excellent stiffness and recovery characteristics,2 Designed with the Environment in Mind EcoTouch'" Insulation with PureFiber® Technology contains more than 99% natural ingredients, and includes a minimum of 50% total recycled content —the highest certified recycled content available in the fiberglass industry' EcoTouch' Insulation is GREENGUARD Children & Schools certified'"' and is verified to be formaldehyde free.' SpaceSaver Packaging EcoTouch' Insulation is compression packaged in exclusive SpaceSaver packaging from Owens Corning. SpaceSaver packaging reduces freight and speeds job site handling/ installation. INNOVATIONS FOR LIVING" Design Considerations Kraft and standard foil facings on this insulation will burn and must not be left exposed. Install facings in substantial contact with the finish material. Protect from open flame or other heat source. Buildings utilizing curtainwall construction may be required to be equipped with a sprinkler system to provide adequate fire protection. Check local building codes for specific requirements. Commercial roof/ceiling thermal applications require that the building envelope block the movement of air from the outdoor environment to the conditioned space. Neither the insulation nor its facing should be relied upon to provide an air barrier. Failure to provide an adequate air barrier could lead to loss of thermal control, discomfort of the building occupants and frozen pipes. When insulation is added to the inside perimeter of a structure, the area outside the insulation becomes exposed to greater temperature extremes. Building structures should be inspected to ensure they can withstand the additional expansion and contraction forces. Check for piping which should be protected against freezing. The need for and placement of a vapor retarder in commercial construction depends on many factors. The architect or specifier should evaluate the requirements of each project. If a vapor retarder is specified, maintaining the facing integrity may be important for I EcoTouchTM PINK° FIBERGLASTM Insulation with PureFiber° Technology Product Data Sheet Product Data - Kraft Foil Available Vapor Retarder Facings, Perms Maximum' I 0.5 Water Absorption, Maximum by Volume Less than 0.05% Dimensional Stability, Linear Shrinkage Less than 0.1 I. Products are tested in accordance: R-Value ASTM C 518 Surface Burning Characteristics ASTM E 84 Perm Rating ASTM E 96 R-values differ. Find out why in the seller's fact sheet on R-values. Higher R-values mean greater insulating power. EcoTouch'" Insulation Technical Data — Wall or Roof/Floor/Ceiling Width Length Thickness R-Value' Metal Frame 16" (406mm) 24" (609mm) 48" (1,219mm) 96" (2,438mm) 3%" (89mm) I I Construction 16" (406mm) 24" (609mm) 48' (1,219mm) 96" (2,438mm) 3YV (89mm) 13 16" (406mm) 24" (609mm) 96° (2,438mm) 3%i' (89mm) 15 16" (406mm) 24" (609mm) 46" (1,219mm) 96' (2,436mm) 6'/," (159mm) 19 16" (406mm) 24" (6G9mm) 96" (2,438mm) 5%z (139mm) 21 Wood Frame 15" (381mm) 23' (584mm) 48" (1,219mm) 93" (2,362mm) NY' (89mm) I I Construction 15" (381mm) 23" (584mm) 48" (1,219mm) 93' (2,362mm) 3%>" (89mm) 13 Walls 15" (381mm) 23" (584mm) 93" (2,362rnm) 3%" (89mm) 15 15" (381mm) 19%" 23" (584mm) 48" (1,219mm) 93" (2,362,mm) 6YV (159mm) 19 15' (381mm) 23" (584mm) 93" (2,362mm) 5V? (139mm) 21 Roof/Floor/ 15" (381mm) 19'/." 23" (584mm) 48" (1,219inm) 93" (2362mm) 6'/." (159mm) 19 Ceiling 15" (381mm) 23" (584mm) 48" (1,219mm) 6'/," (171mm) 22 15' (381mm) 23" (584mm) . 48" (1,219mm) 8" (203mm) 25 1%" (394mm) 23'/." (603mm) 48" (1,219mm) 8/," (209mm) 30 16" (406mm) 19A" 24" (609mm) 48" (1,219mm) 9%" (241mm) 30 15%n" (394mm) 23Y.." (603mm) 48" (1,219mm) I OY,," (260mm) 38 16" (406mm) 24" (609mm) 48" (1,219mm) 12" (305mm) 38 EccTouch` Unfaced Insulation complies with the property requirements of ASTM C 665, Type I and ASTM E 136, EcoTouch' Kraft -faced Insulation complies with ASTM C 665, Type 11, Class C. EcoTouch" Foil -faced Insulation complies with ASTM C 665, Type III, Class B and C. I. Higher R-values mean greater insulating power. Find out why in the seller's fact sheet on R-values. Read This Before You Buy What you should know about R-Values The chart shows the R-value of this insulation. R means resistance to heat flow. The higher the R-value, the greater the insulating power. Compare insulation R-values before you buy. There are other factors to consider, The amount of insulation you need depends mainly on the climate, the type and size of your home, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than you'll save on fuel, To get the marked R-value, it is essential that this insulation be installed properly. 11 INNOVATIONS FOR LIVING' Figure I Plywood Bathing I° Vemilabon Passageway n Drywall al Batt m Figure 2 Concrete Block Ther mal Batt Insulation I I Gypsum Drywall Metal Stud Track EcoTou&m PINK° FIBERGLASTM Insulation with PureFiber° Technology Product Data Sheet effective moisture/humidity control. Repair any punctures or tears in the facing by taping. Follow the tape manufacturer's application recommendations. Insulation installed too close to light fixtures may affect the luminaire's performance. Do not install insulation on top of or within 3" of recessed light fixtures unless the fixtures are approved for such use. This is a requirement of the National Electrical Code. Due to the potential for skin irritation, EcciTouch' Unfaced Insulation should not be used for exposed applications where it will be subject to human contact. Installation Between Wood Studs/Rafters EcoTouch- Insulation fits between studs. If required, the flanges can be stapled to either the face or the side of the stud every 8-12" to prevent gaping or "fish mouth ing" of the vapor retarder. EcoTouch' Unfaced insulation can be friction -fit between studs after the cover material has been installed on one side of the cavity. Use wire or metal straps to hold insulation in place in applications without a cover material, or where the insulation does not fill the depth of the cavity. Cathedral ceiling products (R3OC and R38C) are intended to be friction -fit between rafters. Cathedral ceiling insulation should be installed to provide a minimum I" ventilation passageway between the roof deck and insulation. (See Figure 1) It is recommended to use a vent baffle to assure proper clearance. Between Metal Studs EcoTouch'M Insulation can be friction -fit in place until the interior finish is applied. Insulation should fill the cavity and the wall should eventually be closed on both sides. (See Figure 2) In areas where it will be applied in heights over 8', use wire or metal straps to hold the product in place until the interior finish is applied. When faced insulation is used, the attachment flanges may be taped to the face of the metal stud prior to applying the interior finish. Wire or metal straps should also be used to hold the product in place in applications without a cover material or where the stud depth is larger than the insulation thickness. Furring Strips EcoTouch'' Insulation can be applied between furring strips, hat channels, or Z shaped furring in areas where a finish surface will be installed. Contact the furring strip manufacturer for appropriate fastening system. Caution: FIBERGLAS' insulation may cause temporary irritation to the skin, eyes and respiratory tract. Avoid contact with eyes and skin, wear loose -fitting, long-sleeved clothing, gloves and eye protection when handling and applying the material. Wash with soap and warm water after handling. Wash work clothes separately and wipe out washer. n INNOVATIONS FOR LIVING" Applicable Standards EcciTouch°d Unfaced Insulation is manufactured in compliance with ASTM Standard Specification C 665 and is classified noncombustible per ASTM E 136, EcoTouch' Kraft -faced Insulation is manufactured in compliance with ASTM C 665, Type II, Class C. EcoTouch" Foil -faced Insulation is manufactured in compliance with ASTM C 665, Type III, Class B and C. Federal Specification HH-1-521 F has been canceled and is replaced by ASTM C 665, The thermal resistance values for EcoTouch' Insulation were tested in accordance with ASTM C 518; R-value for insulation only. The surface burning characteristics of EcoTouch'' Insulation were derived from products tested in accordance with ASTM E 84. This Disclaimer of Liability Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient's sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for the accuracy or reliability of data associated with particular uses of any product described herein. Nothing contained in this bulletin shall be considered a recommendation. The GREENGUARD INDOOR AIR QUALITY CERTIFIED mark is a registered certification mark used under license through the GREENGUARD Environmental Institute. EcoTouch'm PINK® FIBERGLASTM Insulation with PureFiber° Technology Product Data Sheet standard is used solely to measure and describe properties of products in response to heat and flame under controlled laboratory conditions, and should not be used to describe or approve the fire hazard of materials under actual fire conditions. However, the results of these tests may be used as elements of a fire risk assessment that takes into account all of the factors pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest five rating. The vapor retarder permeance of the kraft and foil facings on EcoTouch' Insulation were developed from tests conducted in accordance with ASTM E 96, desiccant method. a1nChildren & SchoolsEENGUARDdoor Air Quality Certified GREENGUARD Indoa, At, Guality end GREENGUARD Child— & Scboah"' applies to EcoTouch^ Unfaced Batts, EcoTouch^ Faced Batts and Unbonded Loosefill Irsulatlon. GREENGUARD Formaldehyde Free applies to EroTouch" Unfaecd Batts and unbonded laosafill inwlalian. GREENGUARD Ghlldran & 6eh,,I,-,Pplias to Flamn Sprnad 2S FSK Faced; Flamo Sprnad 2S Extended Flangaa PSK Faced; Sound Atlenuaticn Batt Inaulatlon; Sonobettas Insulation Unfaced; Sonobatbe In,uletioln KWi,Facod and Metal huildmg inculalion. U; Environment EcoLo9 d'd CCD-016 Applms to EeoTouch^' Unfacad insulation Notes I. As manufactured, FIBERGLAST insulation is resistant to mold growth. However. mold growth can occur on building materials, including insulation, when it becomes contaminated with organic material and when water is present. To avoid mold growth on FIBERGLAST'd insulation, remove any water that has accumulated and correct or repair the source ofthe water as soon as possible. Insulation that has become wet should be inspected for evidence of residual moisture and contamination, and any insulation that is contaminated should be promptly removed and replaced. 2. According to 2010 clinical trial conducted in Toronto, Canada by Ducker Worldwide on behalf of Owens Corning Insulation Syslerns, LLC. 3. Unfaced insulation is made with a minimum of 99 percent by weight natural materials consisting of minerals and plant -based compounds. 4. Certified by Scientific Certifications Systems to have a minimum of 50% recycled glass content, with at least 30% post -consumer recycled and the balance of pre -consumer recycled glass content. 5. Owens Corning" E.coTouch" Unfaced FIBERGI_AS" insulation is verified to be formaldehyde free by the GREENGUARD Environmental Institute. SfS CERTIFIED '4101pion) Sf€% 7pS Fos a+: —a, 6C—IFIC CFJrtIFICattpN SVS,ENe SCSNFalaae SCS Sa%rteyClod comont applies tc Ec TouU Unleoed Baits and R.M. Ea.rauahe' Faced Ran, and Roil,. Looserill insulation, Metal building 1-1,t nn product and 11-1aln An handling rroducls. OWENS CORNING INSULATING SYSTEMS, LLC ONE OWENS CORNING PARKWAY • TOLEDO, OHIO, USA 43659 ® 1-800-GET-PINK° INNOVATIONS FOR ONG' www.owenscorning.com Pub. No. 10013811-B. Printed in U.S.A. March 2011. THE PINK PANTHER" & ©1964-2011 Metro -Goldwyn -Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. ©2011 Owens Corning. isdy--er-/ OWENS CORNING Limited Lifetime Warranty for Fiberglas' Insulation Batts and Fiberglas" Insulation Rolls INTRODUCTION Thank you for your recent purchase of Fiberglas"" Batts ("Insulation Batts") and/or Fiberglas'" Rolls ("Insulation Rolls") manufactured by Owens Corning Insulating Systems, LLC. We believe we manufacture our Insulation Batts and Insulation Rolls to be of the highest quality and that is why we stand behind them with one, of the best warranties in the industry. We have attempted to write this warranty in clear, plain -English terms, including the limitations and restrictions, so you will fully understand the warranty we are making to you. If anything in this warranty is not clear to you, please call us at 1-800-GET-PINKoor visit our website at www.owenscorning.com. Please note that the terms contained here are subject to change without notice. WHO IS COVERED If you live in the United States or Canada and you are the original consumer purchaser (i.e. the homeowner or building owner, not the installer or contractor), or any transferee from the original consumer purchaser, of one of our Insulation Batts and/or Insulation Rolls products (the "Purchaser"), you are entitled to the benefits of this warranty. WHAT IS COVERED Owens Corning Insulating Systems, LLC ("Owens Corning"), subject to the conditions and limitations set forth herein, warrants that its Insulation Batts and Insulation Rolls shall be free from any defect in material or manufacturing that would adversely affect their R-value for the life of the building from the date of installation when such Insulation Batts and Insulation Rolls shall have been properly installed and when subject to normal and proper use. REMEDY (a) If the performance of the Insulation Batts and/or Insulation Rolls is ever materially affected during the warranty period by a defect in material or manufacturing as described in the preceding paragraph, then Purchaser's sole and exclusive remedy, and the limit of Owens Corning's liability for Insulation Batts and/or Insulation Rolls proven to be other than as warranted, whether based upon breach of warranty, negligence, strict liability, tort, breach of contract, or any other legal theory shall be, at Owens Corning's sole option, to provide the Purchaser with (1) a quantity of Insulation Batts or Insulation Rolls sufficient to replace the defective Insulation Batts or Insulation Rolls (non -defective Insulation Batts and/or Insulation Rolls need not and will not be replaced); (2) a quantity of Insulation Batts or Insulation Rolls sufficient to bring the thermal performance of the installed Insulation Batts or Insulation Rolls up to the original intended R-value; or (3) a refund of the original purchase price of the Insulation Batts or Insulation Rolls. (b) OWENS CORNING'S LIABILITY HEREUNDER IS LIMITED TO, AND CAPPED AT, THE REASONABLE COST OFTHE REPLACEMENT OR ADDITIONAL INSULATION BATTS OR INSULATION ROLLS REQUIREDTO ACCOMPLISHTHE REMEDY, OR REFUND OFTHE ORIGINAL PURCHASE PRICE OFTHE INSULATION BATTS OR INSULATION ROLLS, WHICHEVER IS GREATER. (c) OWENS CORNING SHALL HAVE NO LIABILITY FOR THE COST (OF LABOR, DISPOSAL OR OTHERWISE)TO REMOVE THE DEFECTIVE INSULATION BATTS OR INSULATION ROLLS ORTO INSTALL ANY NEW INSULATION BATTS OR INSULATION ROLLS, WHAT IS NOT COVERED This warranty does not apply to and Owens Corning shall not be liable for any cause not expressly covered herein. This warranty does not cover any problems with non -defective material caused by conditions or handling beyond our control. Some examples of conditions not covered by this warranty include failures or defects in the Insulation Batts and/or Insulation Rolls caused by: • causes beyond normal and proper use including, but not limited to: acts of God war or terrorism, fire, flood, wind or other weather damage, exposure to chemicals or the environment; or • failures or distortions in the building structure, or improper installation of neighboring products, or • failure to install the Insulation Batts and/or Insulation Rolls strictly in accordance with Owens Coming's published installation instructions for Insulation Batts and Insulation Rolls; or • failure to install the Insulation Batts and/or Insulation Rolls in compliance with all applicable building codes; or • damage to the Insulation Batts and/or Insulation Rolls caused by alterations made after completion of application, including but not limited to structure changes, equipment installation, painting or application of cleaning solutions, coatings or other modifications; or • non -manufacturing defects, including but not limited to improper maintenance, neglect, accident, casualty, vandalism or misuse of the Insulation Batts and/or Insulation Rolls, or any other cause that disturbs or disrupts the Insulation Batts and/or Insulation Rolls as installed; or • any costs incurred by you that are not authorized in writing, and in advance, by Owens Corning. LIMITATIONS ON COVERAGE THE WARRANTY PROVIDED IS IN LIEU OFALL OTHER GUARANTEES AND WARRANTIES, EXPRESS OR IMPLIED. THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR USE OR PURPOSE AND THE IMPLIED WARRANTY OF MERCHANTABILITY ARE LIMITED IN DURATION TO THE EXPRESS WARRANTY PROVIDED HEREIN UNLESS A SHORTER PERIOD IS PERMITTED BYLAW OWENS CORNING SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, FOR PUNITIVE DAMAGES, OR FOR DAMAGE TO THE BUILDING, ITS CONTENTS OR ITS OCCUPANTS. THIS WARRANTY CONTAINS ALL OF THE PROVISIONS OF YOUR REMEDIES FROM OWENS CORNING. OWENS CORNING's LIABILTY IS LIMITED TO THE PROVISIONS OF THIS WARRANTY, WHETHER ANY CLAIM AGAINST IT IS BASED UPON STRICT LIABILITY, NEGLIGENCE, BREACH OF WARRANTY, BREACH OF CONTRACT, TORT, OR ANY OTHER THEORY OR CAUSE OF ACTION. Some states do not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights that vary from state to state. NOTIFICATION OF CLAIMS If the Insulation Batts and/or Insulation Rolls exhibit what the Purchaser believes to be a manufacturing defect covered under the terms of this warranty, the Purchaser must notify Owens Corning within thirty (30) days of discovery of the issue. Mail written notifications to Owens Corning, One Owens Corning Parkway, Toledo, Ohio 43659, and include a description of the claimed defect, along with the Purchaser's name,Iaddress, telephone nurnber, and date of installation. MODIFICATION OFTHIS LIMITED LIFETIME WARRANTY This warranty may not be changed or modified, except in writing signed by an officer of Owens Corning. No statement or recommendation made, or assistance given by, Owens Corning or its representatives, either oral or in any literature or other documentation, to Purchaser or any other persons in connection with the purchase, use or installation of Insulation Batts and/or Insulation Rolls by or for Purchaser, shall constitute a waiver by Owens Corning of any provision of this warranty for Insulation Batts and/or Insulation Rolls or affect Owens Corning's liability as defined in this warranty document. For further information, please call: OWENS CORNING, ONE OWENS CORNING PARKWAY,TOLEDO, OH 43659; Telephone: 1-800-GET-PINK9 or visit our website at www.owenscorning.com. Effective Date: July 15, 2012 INNOVATIONS FOR LIVING' Pub. No. 10017807. Printed in U.S.A. July 2012, 02012 Owens Corning. All Rights Reserved. - -- -- EcoTouehO�^PINK° FIBERG L:AS�M Insulation INNOYATIONS FOR DYING' Manufacturers Fact Sheet This fact sheet contains important details about Owens Corning's'T" EcoTouch® PINK® FIBERGLASS" Insulation. Read it carefully. The chart below covers the entire line of EcoTouchO products sold under the names Thermal Batt, FastBatt, Cathedral Batt, Basement Blanket'", Sound Attenuation Batt (SAB) and SonobattsO'. The chart includes all products, both unfaced and faced with Kraft paper, foil, polyethylene ("Poly"), FSK or PSK. EcoTouch® PINK' FIBERGLAS' Insulation EcoTouch° PINK° FIBERGLAS'" Insulation Thickness Width Length Piece Pieces/ Package Thickness Width Length Piece Pieces/ Package R-value (inches) (inches) (inches) Sq. Ft. Package Sq.,Ft. R-value (inches) (inches) (inches) Sq. Ft. Package Sq. Ft. 8 2.5 16 96 10.7 20 213.3 13 3.5 23 93 14.9 II 163.4 8 2.5 24 96 16.0 20 320.0 13 3.5 24 48 8.0 24 192.0 II 3.5 15 93 9.7 16 155.0 13 3.5 24 96 16.0 II 176.0 II 3.5 15 94 9.8 9 88.1 13 3.5 24 96 16.0 12 192.0 II 3.5 15 105 10.9 16 175.0 13 3.5 48 480 160.0 1 160.0 II 3.5 16 96 10.7 16 170.7 15 3.5 II 93 7.1 14 99.5 II 3.5 23 93 14.9 16 237.7 15 3.5 15 93 9.7 7 67.8 II 3.5 23 96 15.3 16 245.3 15 3.5 15 93 9.7 8 77.5 II 3.5 24 48 8.0 32 256.0 15 3.5 15 105 10.9 7 76.6 II 3.5 24 96 16.0 16 256.0 15 3.5 15 105 10.9 8 87.5 II 3.5 48 720 240.0 1 240.0 15 3.5 16 96 10.7 7 74.7 13 3.5 II 93 7.1 22 156.3 15 3.5 16 96 10.7 8 85.3 13 3.5 15 93 9.7 10 96.9 15 3.5 2.3 93 14.9 7 104.0 13 3.5 15 93 9.7 II 106.6 15 3.5 24 96 16.0 7 112.0 13 3.5 15 93 9.7 13 125.9 19 6.25 II 93 7.1 16 113.7 13 3.5 15 105 10.9 12 131.3 19 6.25 15 48 5.0 16 80.0 13 3.5 15 94 9.8 9 88.1 19 6.25 15 93 9.7 8 77.5 13 3.5 15.25 93 9.8 12 118.2 19 6.25 15 94 9.8 5 49.0 13 3.5 15.25 93 9.8 13 128.0 19 6.25 15 105 10.9 8 87.5 13 3.5 15.25 105 11.1 12 133.4 19 6.25 15 470 49.0 1 49.0 13 3.5 16 96 10.7 II 117.3 19 6.25 15.25 93 9.8 8 78.8 13 3.5 16 96 10.7 13 138.7 19 6.25 15.25 105 11.1 8 89.0 13 3.5 19.25 93 12.4 11 136.8 19 6.25 16 48 5.3 16 85.3 19 625 16 96 10 7 8 85 3 Read This Before You Buy What you should know about R-Values The chart shows the R-values of this insulation. R means resistance to heat flow. The higher the R-value, the greater the insulating power. Compare insulation R-values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend on the climate, the type and size of house, the amount of insulation already in your house, and your fuel -use patterns and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R-value, it is essential that this insulation be installed properly. 19 6.25 19.25 48 6.4 16 102.7 19 6.25 19.25 93 12.4 8 99.5 19 6.25 19.25 96 12.8 8 102.7 19 6.25 23 48 7.7 16 122.7 19 6.25 23 93 14.9 8 118.8 19 6.2.5 23 94 15.0 5 75.1 19 6.25 23 96 15.3 8 122.7 19 6.25 23 470 75.1 1 75.1 19 6.25 24 48 8.0 16 128.0 19 6.25 24 96 16.0 8 128.0 19 6.25 48 470 156.7 1 156.7 19 6.25 48 480 160.0 1 160.0 21 5.5 15 93 9.7 7 67.8 21 5.5 15 93 9.7 8 77.5 21 5.5 15 105 10.9 8 87.5 21 5.5 16 96 10.7 7 74.7 21 5.5 23 93 14.9 6 89.1 21 5.5 24 96 16.0 7 112.0 22 6.75 15 48 5.0 14 70.0 ueh°FPINK'. FIBERGLASrM, Insulation Manufacturers Fact Sheet EcoTouch® PINK® FIBERGLAS"" Insulation Thickness Width Length Piece Pieces/ Package R-value (inches) (inches) (inches) Sq. Ft. Package Sq. Ft. 22 6.75 23 48 7.7 14 107.3 22 6.75 24 48 8.0 14 112.0 25 8 19.25 96 12.8 6 77.0 25 8 23 96 15.3 6 92.0 25 8 16 96 10.7 6 64.0 25 8 16 48 5.3 12 64.0 25 8 24 96 16.0 6 96.0 30 9.5 12 48 1.0 20 180.0 30 9.5 15 48 5.0 10 50.0 30 9.5 15 300 31.3 1 31.3 30 9.5 16 48 5.3 10 53.3 30 9.5 16 48 5.3 II 58.7 30 9.5 19.25 48 6.4 10 64.2 30 9.5 23 300 47.9 1 I 47.9 30 9.5 24 48 8.0 10 80,0 30 9.5 24 48 8.0 II i 88.0 30 8.25 15.5 48 5.2 II 56.8 30 8.25 23.75 45 7.4 10 74.2 30 8.25 23.75 48 7.9 10 79.2 38 12 16 48 5.3 8 j 42.7 38 12 19.25 48 6.4 8 51.3 38 12 24 48 8.0 8 64.0 38 10.25 15.5 48 5.2 8 41.3 38 10.25 23.75 48 7.9 8 63.3 Please contact 419-248-6557 for additional information. Email: gettech@owenscorning.com Disclaimer of Liability Technical information contained herein is furnished OWENS CORNING INSULATING SYSTEMS, LLC ONE OWENS CORNING PARKWAY • TOLEDO, OHIO, USA43659 a without charge or obligation and is given and accepted at 1-800-GET-PINK® recipient's sole risk. Because conditions of use may vary INNOVATIONS FOR LIVING' www.owenscorning.com - and are beyond our control, Owens Corning makes no Pub. No. 10017881. Printed in U.S.A. December 2012. THE PINK --' - representation about, and is not responsible or liable for PANTHER'" & ©1964-2012 Metro -Goldwyn -Mayer Studios Inc. All the accuracy or reliability ofdata associated with particular Rights Reserved. The color PINK is a registered trademark of Owens :Q, uses of any product described herein. Corning. 0 2012 Owens Corning. All Rights Reserved.