Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutPRODUCT DATA SHEET• SCANN EcoTouch PINK FIBERGLAS Insulation
BY with PureFiber° Technology
INNOVATIONS FOR LIVING' Loeika
Description
Owens Corning EcoTouch'
Insulation with PureFiber5
Technology is flexible insulation
and is made in R-values from
I I to 38: EcoTouch" Insulation
is available plain, or faced with
either a kraft or foil vapor
retarder. The product is
manufactured in thicknesses from
3%2" to 12."
Uses
EcoToucH" Insulation can be used
in a wide range of exterior wall
and roof/ceiling applications, The
product can be installed in wood
or metal framing cavities, or can
be installed between furring strips.
Product Data Sheet
Surface Burning Characteristics/Building Code
Construction Classification
Produets Flame Spread Smoke Developed ICC
Unfaced <25 <50 All Types
Foil Faced <75 <150 III, IV, V
Kraft Faced N/R N/R III, IV, V
EcoTouch" Insulation complies with ]CC (International Building Code), model code requirements for building
construction types listed above.
Kraft and standard foil facing will burn. Do not leave exposed. Facing must be installed in substantial contact with
an approved ceiling, floor or wall material. Keep open flame and other heat sources away from facing. Do not place
insulation within 3" of light fixtures or similar electrical devices unless device is labeled for contact with insulation.
Use only unlaced insulation between wood framing and masonry chimneys. Do not use insulation in spaces around
metalIIchimneys, fireplaces, or flues. EcoTouch" Unfaced insulation is considered non-combustible by model building
codes. Flame Spread 25 products are flame spread rated and can be left exposed where codes allow. See package for
warnings, fire hazard and installation instructions, or call 1-800-GET-PINKP
Duelto the potential for skin irritation, EcoTouch'" Unfaced Insulation should not be used for exposed applications
where it will be subject to human contact.
I
Features and Benefits
Excellent Thermal Control
With the range of R-values and
thicknesses available, EcoTouch""
Insulation can meet most thermal
specifications with ease, The R30C
and R38C provide excellent
thermal performance in the limited
space of cathedral ceilings.
Effective Acoustical Control
EcoTouch' Insulation enhances
interior noise control by
improving the Sound Transmission
Class (STC) of walls and floor/
ceiling assemblies.
Long Term Performance
EcoTouch'°' Insulation is
dimensionally stable and will not
slump within the wall cavity. Due
to its inorganic fibers, EcoTouch'
Insulation will not rot or mildew'
and is noncorrosive to steel,
copper, and aluminum.
Easy Installation
EcoTouch' Insulation is easy to
handle and install. Sized for
installation in either wood or
metal stud construction,
EcoTouch' Insulation can either
be friction -fit or stapled into
place. Trimming and fabrication
can be done with an ordinary
utility knife and is easily installed
into odd -shaped cavities and small
spaces. With less dust than other
fiberglass insulation products,
EcoTouch'" Insulation has excellent
stiffness and recovery
characteristics,2
Designed with the
Environment in Mind
EcoTouch'" Insulation with
PureFiber® Technology contains
more than 99% natural
ingredients, and includes a
minimum of 50% total recycled
content —the highest certified
recycled content available in the
fiberglass industry' EcoTouch'
Insulation is GREENGUARD
Children & Schools certified'"'
and is verified to be formaldehyde
free.'
SpaceSaver Packaging
EcoTouch' Insulation is
compression packaged in
exclusive SpaceSaver packaging
from Owens Corning. SpaceSaver
packaging reduces freight and
speeds job site handling/
installation.
INNOVATIONS FOR LIVING"
Design Considerations
Kraft and standard foil facings on
this insulation will burn and must
not be left exposed. Install facings
in substantial contact with the
finish material. Protect from open
flame or other heat source.
Buildings utilizing curtainwall
construction may be required to
be equipped with a sprinkler
system to provide adequate fire
protection. Check local building
codes for specific requirements.
Commercial roof/ceiling thermal
applications require that the
building envelope block the
movement of air from the
outdoor environment to the
conditioned space. Neither the
insulation nor its facing should be
relied upon to provide an air
barrier. Failure to provide an
adequate air barrier could lead to
loss of thermal control,
discomfort of the building
occupants and frozen pipes.
When insulation is added to the
inside perimeter of a structure,
the area outside the insulation
becomes exposed to greater
temperature extremes. Building
structures should be inspected to
ensure they can withstand the
additional expansion and
contraction forces. Check for
piping which should be protected
against freezing.
The need for and placement of a
vapor retarder in commercial
construction depends on many
factors. The architect or specifier
should evaluate the requirements
of each project. If a vapor retarder
is specified, maintaining the facing
integrity may be important for
I
EcoTouchTM PINK° FIBERGLASTM Insulation
with PureFiber° Technology
Product Data Sheet
Product Data
-
Kraft Foil
Available Vapor Retarder Facings, Perms Maximum'
I 0.5
Water Absorption, Maximum by Volume
Less than 0.05%
Dimensional Stability, Linear Shrinkage
Less than 0.1
I. Products are tested in accordance:
R-Value ASTM C 518
Surface Burning Characteristics ASTM E 84
Perm Rating ASTM E 96
R-values differ. Find out why in the seller's fact sheet on
R-values. Higher R-values mean greater insulating power.
EcoTouch'" Insulation Technical Data — Wall or Roof/Floor/Ceiling
Width
Length Thickness
R-Value'
Metal Frame 16" (406mm) 24" (609mm)
48" (1,219mm) 96" (2,438mm) 3%" (89mm)
I I
Construction 16" (406mm) 24" (609mm)
48' (1,219mm) 96" (2,438mm) 3YV (89mm)
13
16" (406mm) 24" (609mm)
96° (2,438mm) 3%i' (89mm)
15
16" (406mm) 24" (609mm)
46" (1,219mm) 96' (2,436mm) 6'/," (159mm)
19
16" (406mm) 24" (6G9mm)
96" (2,438mm) 5%z (139mm)
21
Wood Frame 15" (381mm) 23' (584mm)
48" (1,219mm) 93" (2,362mm) NY' (89mm)
I I
Construction 15" (381mm) 23" (584mm)
48" (1,219mm) 93' (2,362mm) 3%>" (89mm)
13
Walls 15" (381mm) 23" (584mm)
93" (2,362rnm) 3%" (89mm)
15
15" (381mm) 19%" 23" (584mm)
48" (1,219mm) 93" (2,362,mm) 6YV (159mm)
19
15' (381mm)
23" (584mm)
93" (2,362mm)
5V? (139mm)
21
Roof/Floor/ 15" (381mm)
19'/." 23" (584mm)
48" (1,219inm) 93" (2362mm)
6'/." (159mm)
19
Ceiling 15" (381mm)
23" (584mm)
48" (1,219mm)
6'/," (171mm)
22
15' (381mm)
23" (584mm) .
48" (1,219mm)
8" (203mm)
25
1%" (394mm)
23'/." (603mm)
48" (1,219mm)
8/," (209mm)
30
16" (406mm)
19A" 24" (609mm)
48" (1,219mm)
9%" (241mm)
30
15%n" (394mm)
23Y.." (603mm)
48" (1,219mm)
I OY,," (260mm)
38
16" (406mm)
24" (609mm)
48" (1,219mm)
12" (305mm)
38
EccTouch` Unfaced Insulation complies with the property requirements of ASTM C 665, Type I and ASTM E 136,
EcoTouch' Kraft -faced Insulation complies with ASTM C 665, Type 11, Class C. EcoTouch" Foil -faced Insulation complies
with ASTM C 665, Type III, Class B and C.
I. Higher R-values mean greater insulating power. Find out why in the seller's fact sheet on R-values.
Read This Before You Buy
What you should know about R-Values
The chart shows the R-value of this insulation. R means resistance
to heat flow. The higher the R-value, the greater the insulating power.
Compare insulation R-values before you buy.
There are other factors to consider, The amount of insulation you
need depends mainly on the climate, the type and size of your home,
and your fuel use patterns and family size. If you buy too much insulation,
it will cost you more than you'll save on fuel,
To get the marked R-value, it is essential that this insulation
be installed properly.
11
INNOVATIONS FOR LIVING'
Figure I
Plywood
Bathing
I° Vemilabon
Passageway
n Drywall
al Batt
m
Figure 2
Concrete Block
Ther mal Batt
Insulation
I I
Gypsum Drywall
Metal Stud
Track
EcoTou&m PINK° FIBERGLASTM Insulation
with PureFiber° Technology
Product Data Sheet
effective moisture/humidity
control. Repair any punctures or
tears in the facing by taping. Follow
the tape manufacturer's
application recommendations.
Insulation installed too close to
light fixtures may affect the
luminaire's performance. Do not
install insulation on top of or
within 3" of recessed light fixtures
unless the fixtures are approved
for such use. This is a requirement
of the National Electrical Code.
Due to the potential for skin
irritation, EcciTouch' Unfaced
Insulation should not be used for
exposed applications where it will
be subject to human contact.
Installation
Between Wood Studs/Rafters
EcoTouch- Insulation fits between
studs. If required, the flanges can
be stapled to either the face or
the side of the stud every 8-12"
to prevent gaping or
"fish mouth ing" of the vapor
retarder.
EcoTouch' Unfaced insulation can
be friction -fit between studs after
the cover material has been
installed on one side of the cavity.
Use wire or metal straps to hold
insulation in place in applications
without a cover material, or
where the insulation does not fill
the depth of the cavity.
Cathedral ceiling products
(R3OC and R38C) are intended
to be friction -fit between rafters.
Cathedral ceiling insulation should
be installed to provide a minimum
I" ventilation passageway between
the roof deck and insulation. (See
Figure 1) It is recommended to
use a vent baffle to assure proper
clearance.
Between Metal Studs
EcoTouch'M Insulation can be
friction -fit in place until the
interior finish is applied. Insulation
should fill the cavity and the wall
should eventually be closed on
both sides. (See Figure 2)
In areas where it will be applied
in heights over 8', use wire or
metal straps to hold the product
in place until the interior finish is
applied. When faced insulation is
used, the attachment flanges may
be taped to the face of the metal
stud prior to applying the interior
finish. Wire or metal straps
should also be used to hold the
product in place in applications
without a cover material or
where the stud depth is larger
than the insulation thickness.
Furring Strips
EcoTouch'' Insulation can be
applied between furring strips, hat
channels, or Z shaped furring in
areas where a finish surface will
be installed. Contact the furring
strip manufacturer for
appropriate fastening system.
Caution: FIBERGLAS' insulation
may cause temporary irritation
to the skin, eyes and respiratory
tract. Avoid contact with eyes
and skin, wear loose -fitting,
long-sleeved clothing, gloves and
eye protection when handling
and applying the material. Wash
with soap and warm water after
handling. Wash work clothes
separately and wipe out washer.
n
INNOVATIONS FOR LIVING"
Applicable Standards
EcciTouch°d Unfaced Insulation is
manufactured in compliance with
ASTM Standard Specification C
665 and is classified
noncombustible per ASTM E 136,
EcoTouch' Kraft -faced Insulation is
manufactured in compliance with
ASTM C 665, Type II, Class C.
EcoTouch" Foil -faced Insulation is
manufactured in compliance with
ASTM C 665, Type III, Class B
and C. Federal Specification
HH-1-521 F has been canceled and
is replaced by ASTM C 665,
The thermal resistance values for
EcoTouch' Insulation were tested
in accordance with ASTM C 518;
R-value for insulation only.
The surface burning characteristics
of EcoTouch'' Insulation were
derived from products tested in
accordance with ASTM E 84. This
Disclaimer of Liability
Technical information contained herein is furnished
without charge or obligation and is given and accepted
at recipient's sole risk. Because conditions of use may
vary and are beyond our control, Owens Corning makes
no representation about, and is not responsible or
liable for the accuracy or reliability of data associated
with particular uses of any product described herein.
Nothing contained in this bulletin shall be considered a
recommendation.
The GREENGUARD INDOOR AIR QUALITY
CERTIFIED mark is a registered certification mark
used under license through the GREENGUARD
Environmental Institute.
EcoTouch'm PINK® FIBERGLASTM Insulation
with PureFiber° Technology
Product Data Sheet
standard is used solely to measure
and describe properties of
products in response to heat and
flame under controlled laboratory
conditions, and should not be used
to describe or approve the fire
hazard of materials under actual
fire conditions. However, the
results of these tests may be used
as elements of a fire risk
assessment that takes into account
all of the factors pertinent to an
assessment of the fire hazard of a
particular end use. Values are
reported to the nearest five rating.
The vapor retarder permeance of
the kraft and foil facings on
EcoTouch' Insulation were
developed from tests conducted
in accordance with ASTM E 96,
desiccant method.
a1nChildren & SchoolsEENGUARDdoor Air Quality Certified
GREENGUARD Indoa, At, Guality end GREENGUARD Child— & Scboah"'
applies to EcoTouch^ Unfaced Batts, EcoTouch^ Faced Batts and Unbonded
Loosefill Irsulatlon. GREENGUARD Formaldehyde Free applies to EroTouch"
Unfaecd Batts and unbonded laosafill inwlalian.
GREENGUARD Ghlldran & 6eh,,I,-,Pplias to Flamn Sprnad 2S FSK Faced;
Flamo Sprnad 2S Extended Flangaa PSK Faced; Sound Atlenuaticn Batt
Inaulatlon; Sonobettas Insulation Unfaced; Sonobatbe In,uletioln KWi,Facod
and Metal huildmg inculalion.
U; Environment
EcoLo9 d'd CCD-016
Applms to EeoTouch^' Unfacad insulation
Notes
I. As manufactured, FIBERGLAST insulation is
resistant to mold growth. However. mold growth
can occur on building materials, including insulation,
when it becomes contaminated with organic material
and when water is present. To avoid mold growth on
FIBERGLAST'd insulation, remove any water that has
accumulated and correct or repair the source ofthe
water as soon as possible. Insulation that has become
wet should be inspected for evidence of residual
moisture and contamination, and any insulation that
is contaminated should be promptly removed and
replaced.
2. According to 2010 clinical trial conducted in Toronto,
Canada by Ducker Worldwide on behalf of Owens
Corning Insulation Syslerns, LLC.
3. Unfaced insulation is made with a minimum of 99
percent by weight natural materials consisting of
minerals and plant -based compounds.
4. Certified by Scientific Certifications Systems to have
a minimum of 50% recycled glass content, with at
least 30% post -consumer recycled and the balance of
pre -consumer recycled glass content.
5. Owens Corning" E.coTouch" Unfaced FIBERGI_AS"
insulation is verified to be formaldehyde free by the
GREENGUARD Environmental Institute.
SfS CERTIFIED
'4101pion) Sf€%
7pS Fos a+: —a,
6C—IFIC CFJrtIFICattpN SVS,ENe
SCSNFalaae
SCS Sa%rteyClod comont applies tc
Ec TouU Unleoed Baits and R.M.
Ea.rauahe' Faced Ran, and Roil,.
Looserill
insulation, Metal building
1-1,t nn product and 11-1aln An
handling rroducls.
OWENS CORNING INSULATING SYSTEMS, LLC
ONE OWENS CORNING PARKWAY
• TOLEDO, OHIO, USA 43659
® 1-800-GET-PINK°
INNOVATIONS FOR ONG' www.owenscorning.com
Pub. No. 10013811-B. Printed in U.S.A. March 2011. THE PINK
PANTHER" & ©1964-2011 Metro -Goldwyn -Mayer Studios Inc. All Rights
Reserved. The color PINK is a registered trademark of Owens Corning.
©2011 Owens Corning.
isdy--er-/
OWENS CORNING
Limited Lifetime Warranty for
Fiberglas' Insulation Batts and Fiberglas" Insulation Rolls
INTRODUCTION
Thank you for your recent purchase of Fiberglas"" Batts ("Insulation Batts") and/or Fiberglas'" Rolls ("Insulation Rolls")
manufactured by Owens Corning Insulating Systems, LLC. We believe we manufacture our Insulation Batts and Insulation Rolls to
be of the highest quality and that is why we stand behind them with one, of the best warranties in the industry.
We have attempted to write this warranty in clear, plain -English terms, including the limitations and restrictions, so you will fully
understand the warranty we are making to you. If anything in this warranty is not clear to you, please call us at 1-800-GET-PINKoor
visit our website at www.owenscorning.com. Please note that the terms contained here are subject to change without notice.
WHO IS COVERED
If you live in the United States or Canada and you are the original consumer purchaser (i.e. the homeowner or building owner, not
the installer or contractor), or any transferee from the original consumer purchaser, of one of our Insulation Batts and/or Insulation
Rolls products (the "Purchaser"), you are entitled to the benefits of this warranty.
WHAT IS COVERED
Owens Corning Insulating Systems, LLC ("Owens Corning"), subject to the conditions and limitations set forth herein, warrants
that its Insulation Batts and Insulation Rolls shall be free from any defect in material or manufacturing that would adversely affect
their R-value for the life of the building from the date of installation when such Insulation Batts and Insulation Rolls shall have been
properly installed and when subject to normal and proper use.
REMEDY
(a) If the performance of the Insulation Batts and/or Insulation Rolls is ever materially affected during the warranty period by a
defect in material or manufacturing as described in the preceding paragraph, then Purchaser's sole and exclusive remedy, and
the limit of Owens Corning's liability for Insulation Batts and/or Insulation Rolls proven to be other than as warranted, whether
based upon breach of warranty, negligence, strict liability, tort, breach of contract, or any other legal theory shall be, at
Owens Corning's sole option, to provide the Purchaser with (1) a quantity of Insulation Batts or Insulation Rolls sufficient to
replace the defective Insulation Batts or Insulation Rolls (non -defective Insulation Batts and/or Insulation Rolls need not and
will not be replaced); (2) a quantity of Insulation Batts or Insulation Rolls sufficient to bring the thermal performance of the
installed Insulation Batts or Insulation Rolls up to the original intended R-value; or (3) a refund of the original purchase price of
the Insulation Batts or Insulation Rolls.
(b) OWENS CORNING'S LIABILITY HEREUNDER IS LIMITED TO, AND CAPPED AT, THE REASONABLE COST OFTHE
REPLACEMENT OR ADDITIONAL INSULATION BATTS OR INSULATION ROLLS REQUIREDTO ACCOMPLISHTHE REMEDY,
OR REFUND OFTHE ORIGINAL PURCHASE PRICE OFTHE INSULATION BATTS OR INSULATION ROLLS, WHICHEVER IS
GREATER.
(c) OWENS CORNING SHALL HAVE NO LIABILITY FOR THE COST (OF LABOR, DISPOSAL OR OTHERWISE)TO REMOVE THE
DEFECTIVE INSULATION BATTS OR INSULATION ROLLS ORTO INSTALL ANY NEW INSULATION BATTS OR INSULATION
ROLLS,
WHAT IS NOT COVERED
This warranty does not apply to and Owens Corning shall not be liable for any cause not expressly covered herein. This warranty
does not cover any problems with non -defective material caused by conditions or handling beyond our control. Some examples of
conditions not covered by this warranty include failures or defects in the Insulation Batts and/or Insulation Rolls caused by:
• causes beyond normal and proper use including, but not limited to: acts of God war or terrorism, fire, flood, wind
or other weather damage, exposure to chemicals or the environment; or
• failures or distortions in the building structure, or improper installation of neighboring products, or
• failure to install the Insulation Batts and/or Insulation Rolls strictly in accordance with Owens Coming's published
installation instructions for Insulation Batts and Insulation Rolls; or
• failure to install the Insulation Batts and/or Insulation Rolls in compliance with all applicable building codes; or
• damage to the Insulation Batts and/or Insulation Rolls caused by alterations made after completion of application,
including but not limited to structure changes, equipment installation, painting or application of cleaning solutions,
coatings or other modifications; or
• non -manufacturing defects, including but not limited to improper maintenance, neglect, accident, casualty,
vandalism or misuse of the Insulation Batts and/or Insulation Rolls, or any other cause that disturbs or disrupts the
Insulation Batts and/or Insulation Rolls as installed; or
• any costs incurred by you that are not authorized in writing, and in advance, by Owens Corning.
LIMITATIONS ON COVERAGE
THE WARRANTY PROVIDED IS IN LIEU OFALL OTHER GUARANTEES AND WARRANTIES, EXPRESS OR IMPLIED. THE
IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR USE OR PURPOSE AND THE IMPLIED WARRANTY OF
MERCHANTABILITY ARE LIMITED IN DURATION TO THE EXPRESS WARRANTY PROVIDED HEREIN UNLESS A SHORTER
PERIOD IS PERMITTED BYLAW OWENS CORNING SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR
SPECIAL DAMAGES, FOR PUNITIVE DAMAGES, OR FOR DAMAGE TO THE BUILDING, ITS CONTENTS OR ITS OCCUPANTS.
THIS WARRANTY CONTAINS ALL OF THE PROVISIONS OF YOUR REMEDIES FROM OWENS CORNING. OWENS CORNING's
LIABILTY IS LIMITED TO THE PROVISIONS OF THIS WARRANTY, WHETHER ANY CLAIM AGAINST IT IS BASED UPON STRICT
LIABILITY, NEGLIGENCE, BREACH OF WARRANTY, BREACH OF CONTRACT, TORT, OR ANY OTHER THEORY OR CAUSE OF
ACTION.
Some states do not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you
specific legal rights and you may also have other rights that vary from state to state.
NOTIFICATION OF CLAIMS
If the Insulation Batts and/or Insulation Rolls exhibit what the Purchaser believes to be a manufacturing defect covered under
the terms of this warranty, the Purchaser must notify Owens Corning within thirty (30) days of discovery of the issue. Mail
written notifications to Owens Corning, One Owens Corning Parkway, Toledo, Ohio 43659, and include a description of the
claimed defect, along with the Purchaser's name,Iaddress, telephone nurnber, and date of installation.
MODIFICATION OFTHIS LIMITED LIFETIME WARRANTY
This warranty may not be changed or modified, except in writing signed by an officer of Owens Corning.
No statement or recommendation made, or assistance given by, Owens Corning or its representatives, either oral or in any
literature or other documentation, to Purchaser or any other persons in connection with the purchase, use or installation of
Insulation Batts and/or Insulation Rolls by or for Purchaser, shall constitute a waiver by Owens Corning of any provision of this
warranty for Insulation Batts and/or Insulation Rolls or affect Owens Corning's liability as defined in this warranty document.
For further information, please call: OWENS CORNING, ONE OWENS CORNING PARKWAY,TOLEDO, OH 43659; Telephone:
1-800-GET-PINK9 or visit our website at www.owenscorning.com.
Effective Date: July 15, 2012
INNOVATIONS FOR LIVING'
Pub. No. 10017807. Printed in U.S.A. July 2012, 02012 Owens Corning. All Rights Reserved.
- -- --
EcoTouehO�^PINK° FIBERG L:AS�M Insulation
INNOYATIONS FOR DYING'
Manufacturers Fact Sheet
This fact sheet contains important details about Owens Corning's'T" EcoTouch® PINK® FIBERGLASS"
Insulation. Read it carefully. The
chart
below covers the entire line
of EcoTouchO
products sold
under the
names Thermal
Batt, FastBatt,
Cathedral Batt,
Basement Blanket'", Sound Attenuation
Batt (SAB) and
SonobattsO'. The chart
includes all products,
both unfaced and faced with Kraft paper, foil, polyethylene
("Poly"), FSK or
PSK.
EcoTouch® PINK' FIBERGLAS' Insulation
EcoTouch°
PINK° FIBERGLAS'" Insulation
Thickness
Width
Length
Piece
Pieces/
Package
Thickness
Width
Length
Piece
Pieces/
Package
R-value (inches)
(inches)
(inches)
Sq. Ft.
Package
Sq.,Ft.
R-value
(inches)
(inches)
(inches)
Sq. Ft.
Package
Sq. Ft.
8 2.5
16
96
10.7
20
213.3
13
3.5
23
93
14.9
II
163.4
8 2.5
24
96
16.0
20
320.0
13
3.5
24
48
8.0
24
192.0
II 3.5
15
93
9.7
16
155.0
13
3.5
24
96
16.0
II
176.0
II 3.5
15
94
9.8
9
88.1
13
3.5
24
96
16.0
12
192.0
II 3.5
15
105
10.9
16
175.0
13
3.5
48
480
160.0
1
160.0
II 3.5
16
96
10.7
16
170.7
15
3.5
II
93
7.1
14
99.5
II 3.5
23
93
14.9
16
237.7
15
3.5
15
93
9.7
7
67.8
II 3.5
23
96
15.3
16
245.3
15
3.5
15
93
9.7
8
77.5
II 3.5
24
48
8.0
32
256.0
15
3.5
15
105
10.9
7
76.6
II 3.5
24
96
16.0
16
256.0
15
3.5
15
105
10.9
8
87.5
II 3.5
48
720
240.0
1
240.0
15
3.5
16
96
10.7
7
74.7
13 3.5
II
93
7.1
22
156.3
15
3.5
16
96
10.7
8
85.3
13 3.5
15
93
9.7
10
96.9
15
3.5
2.3
93
14.9
7
104.0
13 3.5
15
93
9.7
II
106.6
15
3.5
24
96
16.0
7
112.0
13 3.5
15
93
9.7
13
125.9
19
6.25
II
93
7.1
16
113.7
13 3.5
15
105
10.9
12
131.3
19
6.25
15
48
5.0
16
80.0
13 3.5
15
94
9.8
9
88.1
19
6.25
15
93
9.7
8
77.5
13 3.5
15.25
93
9.8
12
118.2
19
6.25
15
94
9.8
5
49.0
13 3.5
15.25
93
9.8
13
128.0
19
6.25
15
105
10.9
8
87.5
13 3.5
15.25
105
11.1
12
133.4
19
6.25
15
470
49.0
1
49.0
13 3.5
16
96
10.7
II
117.3
19
6.25
15.25
93
9.8
8
78.8
13 3.5
16
96
10.7
13
138.7
19
6.25
15.25
105
11.1
8
89.0
13 3.5
19.25
93
12.4
11
136.8
19
6.25
16
48
5.3
16
85.3
19
625
16
96
10 7
8
85 3
Read This Before You Buy
What you should know about R-Values
The chart shows the R-values of this insulation.
R means resistance to heat flow. The higher
the R-value, the greater the insulating power.
Compare insulation R-values before you buy.
There are other factors to consider. The amount
of insulation you need depends mainly on the
climate you live in. Also, your fuel savings from
insulation will depend on the climate, the type
and size of house, the amount of insulation
already in your house, and your fuel -use patterns
and family size. If you buy too much insulation, it
will cost you more than what you'll save on fuel.
To get the marked R-value, it is essential that this
insulation be installed properly.
19
6.25
19.25
48
6.4
16
102.7
19
6.25
19.25
93
12.4
8
99.5
19
6.25
19.25
96
12.8
8
102.7
19
6.25
23
48
7.7
16
122.7
19
6.25
23
93
14.9
8
118.8
19
6.2.5
23
94
15.0
5
75.1
19
6.25
23
96
15.3
8
122.7
19
6.25
23
470
75.1
1
75.1
19
6.25
24
48
8.0
16
128.0
19
6.25
24
96
16.0
8
128.0
19
6.25
48
470
156.7
1
156.7
19
6.25
48
480
160.0
1
160.0
21
5.5
15
93
9.7
7
67.8
21
5.5
15
93
9.7
8
77.5
21
5.5
15
105
10.9
8
87.5
21
5.5
16
96
10.7
7
74.7
21
5.5
23
93
14.9
6
89.1
21
5.5
24
96
16.0
7
112.0
22
6.75
15
48
5.0
14
70.0
ueh°FPINK'. FIBERGLASrM, Insulation
Manufacturers Fact Sheet
EcoTouch® PINK® FIBERGLAS"" Insulation
Thickness Width Length Piece Pieces/ Package
R-value (inches) (inches) (inches) Sq. Ft. Package Sq. Ft.
22 6.75 23 48 7.7 14 107.3
22
6.75
24
48
8.0
14
112.0
25
8
19.25
96
12.8
6
77.0
25
8
23
96
15.3
6
92.0
25
8
16
96
10.7
6
64.0
25
8
16
48
5.3
12
64.0
25
8
24
96
16.0
6
96.0
30
9.5
12
48
1.0
20
180.0
30
9.5
15
48
5.0
10
50.0
30
9.5
15
300
31.3
1
31.3
30
9.5
16
48
5.3
10
53.3
30
9.5
16
48
5.3
II
58.7
30
9.5
19.25
48
6.4
10
64.2
30
9.5
23
300
47.9
1
I 47.9
30
9.5
24
48
8.0
10
80,0
30
9.5
24
48
8.0
II
i 88.0
30
8.25
15.5
48
5.2
II
56.8
30
8.25
23.75
45
7.4
10
74.2
30
8.25
23.75
48
7.9
10
79.2
38
12
16
48
5.3
8
j 42.7
38
12
19.25
48
6.4
8
51.3
38
12
24
48
8.0
8
64.0
38
10.25
15.5
48
5.2
8
41.3
38
10.25
23.75
48
7.9
8
63.3
Please contact 419-248-6557 for additional information. Email: gettech@owenscorning.com
Disclaimer of Liability
Technical information contained herein is furnished
OWENS CORNING INSULATING SYSTEMS, LLC
ONE OWENS CORNING PARKWAY
• TOLEDO, OHIO, USA43659
a
without charge or obligation and is given and accepted at
1-800-GET-PINK®
recipient's sole risk. Because conditions of use may vary
INNOVATIONS FOR LIVING' www.owenscorning.com -
and are beyond our control, Owens Corning makes no
Pub. No. 10017881. Printed in U.S.A. December 2012. THE PINK
--' -
representation about, and is not responsible or liable for
PANTHER'" & ©1964-2012 Metro -Goldwyn -Mayer Studios Inc. All
the accuracy or reliability ofdata associated with particular
Rights Reserved. The color PINK is a registered trademark of Owens
:Q,
uses of any product described herein.
Corning. 0 2012 Owens Corning. All Rights Reserved.