HomeMy WebLinkAboutPLAN REVIEW COMMENTSw f1T1�f'�I!GINEERIr1GG110��C.. PROFESSIONAL'STRUCTURAL CONSULTANTS 404 SW Camden Ave., FL 34994 Voice: (772)223-9883 Fax: (772)223-9502 July 31, 2014 St. Lucie County Building and Code Regulation Division Plan Review Comments 2300 Virginia Ave. Ft. pierce, FL 34982 RE: Plan Review Comments, Permit # 1406-0259 /116omment 1: Helical Pile Tech. Data GC to provide Comment 2: Crawl Space Vent Requirements to Comply with FBC 2010 R322.2.2 Floor Area =1600 SF. Vent Area=1600 SI =11.11 SF. (3) I '-8 " x 3 '-4 " Openings = 16.67 SF, Therefore Adequate. Vent Area Complies, Note Added to Sheet S-2 Comment 3: Wood I -Joists are not P.T., Beams are not P.T. Floor System has been Changed to Pre -Engineered P.T. Wood Trusses, Parallam Beams Called out are Pressure Treated, see S-2, FF raised 3/ "to allow non P. T. plywood floor I t�Comment 4: Under Floor Batt Insul. Improper Batt Insulation has been Changed to Icynene Foam t/ Comment 5: Below Floor Plumbing to Resist Floodwater Forces Note added to plan, see sheet S-2 Comment 6: Wall Panel Shop Drawings GC to provide i Comment 7: Roof Truss Shop Drawings GC to provide I &--c"'omment 8: Correct/Sheet/Detail Numbers All Section Callouts are now correct. "S" number shown on section cut on plan sheets reference sheet number section is drawn on, "S" number on Section references the plan sheet the section first appears on. See "Section Key" on Sheet A-1 �omment 9: Ventilation to Comply with FBC 2010 R408.1 Complies, Note Added to Sheet S-2 pleomment 10: Show Compliance with Table 301.2(1), Climatic Design Criteria Termite Risk "Very High", Design Complies comment 11: Correct Page & Detail Numbers Page & Detail Callouts are correct, see Comment 8 mment 12: Show Compliance with FBC 2010 R315 Carbon Monoxide Alarms Smoke Alarms to Comply. See Note on Sheet A-2 & Electrical Plan Legend Sheet E-1 Comment 13: ' Show Wind Design Pressures Design Pressures are on Sheet A-1 in the General Notes, See "Design Pressures " in " Design Live Load" Section Respect l yPbmilled, T. tiles Pe.E. P:\2014\14-041 THYRRING RESIDENCE\COR\071114-PRI.doc fMf&NEEFSN GRWOS,. PROFESSIONAL 404 SW Voice: (772): August 13, 2014 'URAL CONSULTANTS Ave., FL 34994 Fax:(772)223-9502 St. Lucie County Building and Code Reguli tion Division Attn: Ed Roseberry Plan Review Comments 2300 Virginia Ave. Ft. pierce, FL 34982 RE: Plan Review Comments, Permit # 1 Comment 1: Vented Crawlspace Opening Compliance The vented crawlspace net area openings comply with CH 322.2.2 Comment 2: All wood material below flood elev. Must be moisture resistant per code All materials are moisture resistant. The floor joists are P.T., The dropped beams are 51/4""X14" ME PARALLAM PLUS PSL SL1. This beam is wolmanized (P.T.), for product specifications go to... Comment 3: Provide Wall Panel Shop Drawings Wall panel shop drawings are for erector only. They are not generated until just prior to fabrication. GC will provide approved set when received from fabricator just prior to erection. Comment 4: Vented Crawlspace See comment 1 Comment 5: Show complete Wind Pressures See Wind Load Schedule Sheet A-1 Comment 6: Sign & Seal all correspondence OK Comment 7: Approved Roof Truss Shop Drawing Layout �C�fRP'�*4ol i � gTILES p�ii�� I�pec .� F �, i 692 , :. tales @6€ �.E. \; ORION • &0 N� �ONAL ENG\\\��� lilllII10 P:\2014\14-041 THYRRING RESIDENCE\COR\071114-PR2.doc