Loading...
HomeMy WebLinkAboutPRODUCT SPECIFICATION° - � BR Bearing Plate Ca MAGNUM MHC1300 3K66 g p Allowable Capacity 25 Tons Compression 120 Tons TensionAV 3-Inch I.D. Collar with 6.00 x 6.00 x 0.38 Bea R „ » ��g� MAGNUM Fits MH325R Magnum@ Helical Piles [BY Description Magnum MHC1300-3K66BR bearing plate cap has 50' tons ultimate capacity, 25 tons working capacity in compression and 41 tons ultimate capacity, 20 tons working capacity in tension. The bearing plate cap consists of a collar -tube with bolt hole for connection to Magnum helical piles and 6.00" x 6.00" x 0.38" plate for embedment in cast -in -place reinforced concrete. The bearing plate cap is designed in accordance with [CC -ES document AC358 as well as IBC, ACI, and AISC codes. Application of the cap varies by project and is the responsibility of registered design professional including minimum embedment for two-way and one-way punching shear, reinforcement of concrete, and pile spacing. � • . SPECIFICATIONS Collar Tube 0.31 in. x 3.00 in. I.D. ASTM A513 GR65+ End Effector 6.00" x 6.00" x 0.38" Steel Bearing Plate Pile Connection (2)1.00" SAE Grade 5 / ASTM A325 Bolts Surface Coating Galvanized per ASTM Al53/A123 (G), Bare Steel (NG), or Epoxy Coated per ICC-ES AC228 (EP) Compatibility MH325R .. CAPACITY Ultimate Compression / Tension 50 Tons / 41 Tons Allowable Compression / Tension ,25 Tons / 20 Tons Note: Cap capacity takes into account strength of collar, end effector, and pile connection. Capacity may be limited by the helical pile itself, bearing/pullout capacity of soil, or strength of the structure to which the cap is attached, whichever is less. Installation Notes: After installation of a Magnum Helical Pile to the correct depth, torque, and capacity, cut-off the pile shaft at the proper elevation. Drill 1.06" holes using Magnum drill template. Place the pile cap over the shaft and secure with two 1.00" bolt. Snug tighten nuts. Place reinforcing steel as required for the project and cast concrete over and around the pile cap. All Magnum Steel & Products Made in U.S.A. Magnum Piering, Inc. 6082 Schumacher Park Dr. West Chester, OH 45069 800-822-7437 www.magnumpiering.com © Copyright 2010 Magnum Piering, Inc. All Rights Reserved. U.S. Patents 6,058,662 and 5,234,287; Other Patents Pending. Rev. 3-27-10 MAGNUM° MH325BR Helical Aal Piles c 50 Ton Ultimate - 25 Ton Allowable Capacity High -Strength 3.0" Diameter, 0.25" Wall, RoIJnd-Shaft with Reinforced (R) Dual Sleeve Coupler & (1)1.0,0" Bolt Description �'W MAGNUM �/ HELICAL PILES Magnum MH325BR Helical Piles have 50 tons ultimate capacit�l and 25 tons working capacity in compression and tension. Lead sections and extensions couple together to extend helical bearing plates to the desired bearing stratum. Round shafts offer increased lateral and buckling resistance compared to solid square shafts. Capacity calculatiops are based on average life expectancy of over 50 years for most soil conditions. Patented Magnum Dual -Cutting Edge helical bearing plates (DCE) enhance penetration through dense soils with occasional cobbles and debris. Custom lengths and helix configurations are available upon request. See Magnum Technical Reference Manual for additional information including design tools, prescriptive specifications and example plans. i /'562-1/2 x 6 x Lead - MHL325BR6K12D14D14DG 3.0" Product Line Helical Bearing Plate Specifications & Available Configurations i Extension - MHE325BR6G 0.375" Thick; ASTM A36 or Higher 3.00 " Helix Pitch 8", 10%12",14" Diameter Standard Circular Helix, or Patented Dual Cutting Edge Helix Sharpened Edges - All Helix *3 ft. Lead or Extension - up to 2 helical bearing plates * 6 ft. Lead or Extension - up to 3 helical bearing plates *10 ft. Lead or Extension - up to 6 helical bearing plates *15 ft. Lead or Extension - up to 8 helical bearing plates * Standard Stocking Length SHAFT HSS 3.00" x 0.25" Wall ASTM A513 65 KSI, or Equivalent I 1.99 in4 Ag 2.10 in2 S 1.33 in3 COUPLING Outer 0.31" Sleeve with 0.25" Insert BOLTS (1)1.00" Diam. SAE Grade 8 / ASTM A490 BLADES 0.375" Thick, Helix Die -Pressed ASTM A36, or Better COATING OPTIONS Hot -Dip Galvanized (G), Bare Steel (NG), Epoxy Powder Coated (EP) -O- 8 ff' Ultimate Capacity -to -Torque Ratio 12,500 ft-lbs Maximum Installation Torque STRUCTURAL... 68 Tons Ultimate Capacity k_L4 Tons Allowable Capacity CAPACITY•-e 50 Tons Ultimate Compression & Tension 25 Tons Allowable Compression & Tension Note: Helical piles shall be installed to appropriate depth into suitable bearing stratum as determined by geotechnical engineer or local practice. Capacity by torque is based on advancing pile to maximum installation torque. A minimum factor of safety of 2.0 is recommended for determining allowable capacity from correlations with final installation torque. Deflections of 0.05" to 1.0" are typical at allowable capacity. A higher factor of safety may be required for tolerable deflections. For tension capacity, helical bearing plates must be deeply embedded. Load tests are recommended when practical. Magnum Pliering, Inc. All Magnum Steel & Products Made in U.S.A. 6082 Schumacher Park Dr. West Chester, OH 45069 800-822-7437 www.magnumpiefing.com © Copyright 2009.10 Magnum Piering, Inc. All Rights Reserved. U.S. Patents 6,058,662 and 5,234,287; Other Patents Pending. Rev. 3-29-2010