Loading...
HomeMy WebLinkAboutREVIEW-COMMENTY Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462.6443 PROPERTY INFORMATION SCAN U REVIEW COMMENTS LL?1� Address: 10751 Ocean Dr B8 City / State / Zip: Jensen Beach, FI 34957 Parcel #: 4511-311-0037-000/4 Jurisdiction: Zoning: HIRD I, Lot#: APPLICATION INFORMATION j Permit Number: 1406-0259 II Stories: Permit Type: I BUILDING RESIDEI TIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Gregory J Morabito Business Name: Gm Construction Llc Business Addr: 313 Sw Albany Ave City / State / Zip: Stuart, FI 34994 �I I, �- L'em r7� )ew� o� hIOZ S l 9fIV Owner(s): Julie Thyrring / Marc Thyrring SAINT LUCIE COUNTY Block: Automatic Sprinkler System? No Fax Number: 772-781-8505 Email: Gmconstruction@Bellsouth. Net REVIEWS AND COMMENTS Review Type Status I, Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING 6/17/2014 Comment: THE COI FRONT COUNTER REVIEW COMPLETE Comment: IS REQUIRED TO SIGN THE FLOOD HAZARD MEMO AT TIME OF PICK UP. Deanna Givens PLANS EXAMINER REVIEW INCOMPLETE � Ed Roseberry 6/1312014 6/13/2014 6/13/2014 7/11/2014 Comment: PLEASE SHOW ON PLANS COMPLIANCE WITH CH 322.2.2 FOR FLOOD VENT REQUIREMENTS IN CRAWL AND CONCEALED SPACES. 7/14/2014 ***"8/7/14 PLEASE CERTIFY THAT OPENINGS BEING USED FOR FLOOD VENTS MEET THE REQUIRED NET CLEAR OPENING REQUIREMENTS. THE NOMINAL SIZE AND SQUARE FOOTAGE OF THE VENTS CANNOT BE USED TO DETERMINE COMPLIANCE WITH CH322.2.2.**** Comment: THE WOOD I JOISTS AND PARALLAM BEAMS PROPOSED ON PLANS DO NOT MEET THE REQUIREMENTS 7/14/2014 FOR FLOOD RESISTANT MATERIALS AND THEREFORE CANNOT BE USED IN THIS PROJECT; AS DESIGNED. ** &7/14 PLEASE SUBMIT MANUFACTURERS TECHNICAL DATA THAT THE PROPOSED USE OF THE ENGINEERED WOOD PRODUCTS SPECIFIED ARE DESIGNED TO BE USED BELOW BFE.**** 7/14/2014 Comment: PLEASE INCLUDE 2 COPIES OF WALL PANEL SHOP DRAWINGS.****PLEASE SUBMIT WALL PANEL MANUFACTURERS SHOP DRAWINGS INCLUDING ALL LOAD RESISTANCE DESIGN.**** Comment: PLEASE SHOW COMPLIANCE WITH CH R408.1 FOR UNDERFLOOR/CRAWLSPACE VENTELATION REQUIREMENTS. 7/14/2014 **"*8R/14 PLEASE CERTIFY THAT OPENINGS BEING USED FOR VENTILTAION MEET THE REQUIRED NET CLEAR OPENING REQUIREMENTS. THE NOMINAL SIZE AND SQUARE FOOTAGE OF THE VENTS CANNOT BE USED TO DETERMINE COMPLIANCE WITH CH R408.1.**** Comment: PLEASE SHOW REQUIRED DESIGN PRESSURE REQUIREMENTS FOR ALL OPENINGS AND STRUCTURAL COMPONENTS, OR SUBMIT A COMPLETED ST. LUCIE CO. PRODUCT APPROCAL AFFIDAVIT.****8/7/14 7/14/2014 PLEASE SHOW REQUIRED DESIGN PRESSURE REQUIREMENTS FOR ROOF ZONES 1,2, AND 3, AND WALL ZONES 4 AND 5. ALSO INCLUDE ALL DESIGN PRESSURES FOR EACH OPENING ON ELEVATION SHEET.-- -,- Planning &:Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462-6443 Y REVIEW COMMENTS Page 2 8/7/2014 Comment: PLEASE SIGN AND SEAL ALL CORESPONDENCE, COMMENT RESPONSE SHEETS, DETAILS, AND PLAN SHEETS. 8/7/2014 Comment: PLEASE SUBMIT A TRUSS MANUFACTURERS LAY OUT PLAN, SIGNED AND SEALED BY THE DESIGN PROFESSIONAL OF RECORD. ZONING REVIEW COMPLETE Lydia Galbraith 6/16/2014 6/17/2014 6/17/2014 Comment: I.