HomeMy WebLinkAboutREVIEW-COMMENTY
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462.6443
PROPERTY INFORMATION
SCAN U REVIEW COMMENTS
LL?1�
Address:
10751 Ocean Dr B8
City / State / Zip:
Jensen Beach, FI 34957
Parcel #:
4511-311-0037-000/4 Jurisdiction:
Zoning:
HIRD I, Lot#:
APPLICATION INFORMATION j
Permit Number:
1406-0259 II Stories:
Permit Type:
I
BUILDING RESIDEI TIAL (SFR UP TO 2 FLOORS)
CONTRACTOR INFORMATION
Contractor Name:
Gregory J Morabito
Business Name:
Gm Construction Llc
Business Addr:
313 Sw Albany Ave
City / State / Zip:
Stuart, FI 34994 �I
I,
�- L'em r7� )ew�
o�
hIOZ S l 9fIV
Owner(s):
Julie Thyrring / Marc Thyrring
SAINT LUCIE COUNTY
Block:
Automatic Sprinkler System? No
Fax Number: 772-781-8505
Email: Gmconstruction@Bellsouth.
Net
REVIEWS AND COMMENTS
Review Type Status I, Reviewed By Date Started Date Completed Date Released
DOCUMENTS MISSING PENDING
6/17/2014 Comment: THE COI
FRONT COUNTER REVIEW COMPLETE
Comment:
IS REQUIRED TO SIGN THE FLOOD HAZARD MEMO AT TIME OF PICK UP.
Deanna Givens
PLANS EXAMINER REVIEW INCOMPLETE � Ed Roseberry
6/1312014 6/13/2014 6/13/2014
7/11/2014
Comment: PLEASE SHOW ON PLANS COMPLIANCE WITH CH 322.2.2 FOR FLOOD VENT REQUIREMENTS IN CRAWL
AND CONCEALED SPACES.
7/14/2014 ***"8/7/14 PLEASE CERTIFY THAT OPENINGS BEING USED FOR FLOOD VENTS MEET THE REQUIRED NET
CLEAR OPENING REQUIREMENTS. THE NOMINAL SIZE AND SQUARE FOOTAGE OF THE VENTS CANNOT BE
USED TO DETERMINE COMPLIANCE WITH CH322.2.2.****
Comment: THE WOOD I JOISTS AND PARALLAM BEAMS PROPOSED ON PLANS DO NOT MEET THE REQUIREMENTS
7/14/2014 FOR FLOOD RESISTANT MATERIALS AND THEREFORE CANNOT BE USED IN THIS PROJECT; AS DESIGNED.
** &7/14 PLEASE SUBMIT MANUFACTURERS TECHNICAL DATA THAT THE PROPOSED USE OF THE
ENGINEERED WOOD PRODUCTS SPECIFIED ARE DESIGNED TO BE USED BELOW BFE.****
7/14/2014 Comment: PLEASE INCLUDE 2 COPIES OF WALL PANEL SHOP DRAWINGS.****PLEASE SUBMIT WALL PANEL
MANUFACTURERS SHOP DRAWINGS INCLUDING ALL LOAD RESISTANCE DESIGN.****
Comment: PLEASE SHOW COMPLIANCE WITH CH R408.1 FOR UNDERFLOOR/CRAWLSPACE VENTELATION
REQUIREMENTS.
7/14/2014 **"*8R/14 PLEASE CERTIFY THAT OPENINGS BEING USED FOR VENTILTAION MEET THE REQUIRED NET
CLEAR OPENING REQUIREMENTS. THE NOMINAL SIZE AND SQUARE FOOTAGE OF THE VENTS CANNOT BE
USED TO DETERMINE COMPLIANCE WITH CH R408.1.****
Comment: PLEASE SHOW REQUIRED DESIGN PRESSURE REQUIREMENTS FOR ALL OPENINGS AND STRUCTURAL
COMPONENTS, OR SUBMIT A COMPLETED ST. LUCIE CO. PRODUCT APPROCAL AFFIDAVIT.****8/7/14
7/14/2014 PLEASE SHOW REQUIRED DESIGN PRESSURE REQUIREMENTS FOR ROOF ZONES 1,2, AND 3, AND WALL
ZONES 4 AND 5. ALSO INCLUDE ALL DESIGN PRESSURES FOR EACH OPENING ON ELEVATION SHEET.--
-,-
Planning &:Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462-6443
Y
REVIEW COMMENTS
Page 2
8/7/2014 Comment: PLEASE SIGN AND SEAL ALL CORESPONDENCE, COMMENT RESPONSE SHEETS, DETAILS, AND PLAN
SHEETS.
8/7/2014 Comment: PLEASE SUBMIT A TRUSS MANUFACTURERS LAY OUT PLAN, SIGNED AND SEALED BY THE DESIGN
PROFESSIONAL OF RECORD.
ZONING REVIEW COMPLETE Lydia Galbraith 6/16/2014 6/17/2014 6/17/2014
Comment: I.