HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2014
FLORIDA ENERGY EFFICIL991DE FOR BUILDING CONSTRUCTION
Florida Department of Business&&,J5gf 1gp1 Regulation - Residential Performance Method
Project Name: McGHEE RESIDENCE
Builder Name:
Street: 689 NETTLES BLVD.
Permit Office:
-City, State, Zp: JENSEN BEACH, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing
New (From Plans)
9. Wall Types (1086.7 sqft)
Insulation Area
a. Concrete Block - Ext Insul, Exterior
R=4.1 966.67 ft2
2. Single family or multiple family
Single-family
b. Frame -Wood, Exterior
R=11.0 120.00 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
1
d. NIA
10. Ceiling Types (807.0 sqft.)
R= ft2
Insulation Area
5. Is this a worst case?
Yes
a. Under Attic (Vented)
R=30.0 807.00 ft2
6. Conditioned floor area above grade (ft2)
807
b. N/A
R= ftZ
R= ft2
c. NIA
Conditioned floor area below grade (ft2)
0
11. Ducts
R ft2
7. Windows(92.2 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: GREAT ROOMiKIT. 6 200
a. U-Factor. Sgl, U=0.65
92.17 ft2
SHGC: SHGC=0.25
12. Cooling systems
kBtulhr Efficiency
b. U-Factor: NIA
a. Central Unit
18.0 SEER:16.00
SHGC:
o. U-Factor: N/A
SHGC:
ft2
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
Area Weighted Average overhang Depth:
1.000 ft.
14. Hot water systems
Area Weighted Average SHGC:
0.250
a. Electric Tankless
Cap:1 gallons
8. Floor Types (806.5 sqft.)
Insulation Area
EF: 0.900
a. Crawlspace
R=19.0 806.60 ff2
b. Conservation features
b. WA
R= ft2
None
c. NIA
R= ft2
15. Credits
CF, Pstat
Total Proposed Modified Loads: 32.42
PASS
Glass/Floor Area: 0.11.4
Total, Baseline Loads: 32.55
1 hereby certify that the plans and specifications covered by
Review of the plans and
Q1 "tIIE Sr9,T1
this calculation are in compliance with the
Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
- _-�',:•�` u
RCP ED BY:
Before construction is completed
c a , t7
DATE: -�
this building will be inspected for
compliance with Section 553.908
0 I,;i1.'
I hereby certify that this building, as designed, is in compliance
Florida Statutes.,
COD
with the Florida Energy Code.
WL
OWNER/AGENT: '-
BUILDING OFFICIAL:
DATE: �o
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- 6-bmpliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an el eakage
test report in accordance with R402.4.1.2.
3/10/2016 8:53 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORMR405 2014
PROJECT
Titre: McGHEE RESIDENCE
Bedrooms: 1
Address Type:
Street Address
Building Type: User
Conditioned Area: 807
Lot #
Owner.
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: Yes
45
PlatBook:
Street:
689 NETTLES BLVD.
Builder Name:
Rotate Angle:
Cross Ventilation: No
County:
ST. LUCIE COUNTY
Permit Office:
y Jurisdiction:
Whole House Fan: No
City, State, Zip:
JENSEN BEACH.
Family Type: Single-family
FL,
New/E)dsting: New (From Plans)
Comment:
CLIMATE
IECC , Design Temp
Int Design Temp Heating Design Daily Temp
Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce Fl ST LUCIE CO INTL 2 39 90
70
75 722
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
807 6456
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
1nfilID Finished Cooled
Heated
1 GREAT ROOM/KIT.
376 3008 Yes 0
1 Yes
Yes
Yes
2 BATH 2
42 336 No 0
1 Yes
Yes
Yes
3 DEN
110 880 No 0
1 Yes
Yes
Yes
4 BEDROOM
110 880 No 1
1
1 Yes
Yes
Yes
5 HALL
61 488 No 0
1 Yes
Yes
Yes
6 WIC
30 240 No 0
1 Yes
Yes
Yes
7 MASTER BATH
78 624 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R Value
Area
Joist R Value
Tile Wood
Carpet
1 Crawlspace
GREAT ROOM/KI 57.2 ft 0
375.5 fl?
19
0 1
0
2 Crawlspace
BATH 2 6 ft 0
42 ft2
19
0 1
0
3 Crawlspace
DEN 25 ft 0
110 ft2
19
0 1
0
4Crawispace
BEDROOM 12 ft 0
110 ft2
19
0 1
0
5 Crawlspace
HALL 4 ft 0
61 fi?
19
0 1
0
6 Crawlspace
WIC 6.3 ft 0
30 ft2
19
0 1
0
7 Crawlspace
MASTER BATH 25.3 ft 0
78 ft2
19
0 1
0
3/10/2016 8:53 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
r VKM-K4U0-LU'I14
ROOF
Roof
Gable
Roof
Solar
SA
Emht
Emitt
Deck
Pitch
/
V
# Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 874 ftZ
168 ft2
Light
0.6
No
0.9
No
0
22.6
ATTIC
V
# Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
300
807 ftz
N
N.
CEILING
# Ceiling Type Space
R Value
Area
Framing Frac
Truss Type
1 Under Attic (Vented) GREAT ROOM/KI 30
376 ft2
0.1
Wood
2 Under Attic (Vented) BATH 2
j 30
42 ftZ
0.1
Wood
3 Under Attic (Vented) DEN
30
110 ftZ
0.1
Wood
4 UnderAt6c (Vented) BEDROOM
30
110 ftz
0.1
Wood
5 Under Attic (Vented) HALL
30
61 ft2
0.1
Wood
6 Under Attic (Vented) WIC
30
30 ftZ
0.1
Wood
7 Under Attic (Vented) MASTER BATH
30
78 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Below
Wall lype Space
_
o
1
N=>NE Exterior Concrete Block - Ext InsGREAT ROO
4.1 25
2
8
0
201.3 ft2
0
0
0.8
0
2
E=>SE Exterior Concrete Block - Ext InsGREAT ROO
4.1 15
0
8
0
120.0 ft2
0
0
0.8
0
3
S=>SW Exterior Concrete Block - Ext InsGREAT ROO
'4.1 2
0
8
0
16.0 ftZ
0
0
0.8
0
4
W=>NW Exterior Concrete Block - Ext InsGREAT ROO
'4.1 15
0
8
0
120.0 ft2
0
0
0.8
0
_
5
E-SE Exterior Concrete Block - Ext Insul BATH 2
4.1 6
0
8
0
48.0 ft2
0
0
0.8
0
_
6
E=>SE Exterior Concrete Block- Ext insul DEN
4.1 11
0
8
0
88.0 W
0
0
0.8
0
_
7
S=>SW Exterior Concrete Block - Ext Insul DEN
4.1 10
0
8
0
80.0 ftZ
0
0
0.8
0
_
8
W=>NW Exterior Frame - Wood DEN
11 4
0
8
0
32.0 ft2
0
0.25
0.8
0
9
N=>NE Exterior Concrete Block- Ext insuBEDROOM
4.1 2
0
8
0
16.0 ftz
0
0
0.8
0
10
W=>NW Exterior Concrete Block - Ext InsuBEDROOM
4.1 10
0
8
0
80.0 ftZ
0
0
0.8
0
_
11
SSW Exterior Frame - Wood HALL
11 4
0
8
0
32.0 ft2
0
0.25
0.8
0
~_
12
W-NW Exterior Concrete Block - Ext Insul WIC
4.1 6
4
8
0
50.7 ft2
0
0
0.8
0
13
E=>SE Exterior Concrete Block - Ext InstAASTER BA
4.1 12
0
8
0
96.0 ftz
0
0
0.8
0
_
14
S-SW Exterior Frame - Wood MASTER BA
11 7
0
8
0
56.0 ftZ
0
0.25
0.8
0
15
W=>NW Exterior Concrete Block - Ext InsHASTER BA
4.1 6
4
8
0
50.7 ft2
0
0
0.8
0
DOORS
# Omt Door Type Space
Storms
U Value Ft In
In
Ft Height
In
Area
1 S=>SW Insulated GREAT ROO
None
.39
2
7
14 ftz
2 S=>SW Insulated HALL
None
.39
3
7
21 ftz
3110/2016 8:53 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
rUPVVI mltuQ-GV I,r
WINDOWS
Orientation shown is the entered orientation (_>) changed to Worst Case.
#
Wall
Oft ID Frame Panes
NFRC
Overhang
U-Factor SHGC Area Depth Separation
Int Shade
Screening
1
2
3
4
6
6
7
N=>NE 1 Metal Low-E Single
N=>NE 1 Metal Low-E Single
N=>NE 1 Metal Low-E Single
W=>NW 4 Metal Low-E Single
S—SW 7 Metal Low-E Single
W=>NW 10 Metal Low E Single
S=>SW 7 Metal Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.65 0.25 8.8 ft2 1 ft 0 in 1 ft4 In
0.65 0.25 15.0 ft2 1 ft 0 in 1 ft4 in
0.65 0.25 16.4 ft2 1 ft 0 in 1 ft 4 in
0.65 0.25 15.0 ft2 1 ft 0 in 1 ft 4 in
0.65 025 15.0 ft2 1 ft 0 in 1 ft 41n
0.66 0.25 15.0 ft2 1 ft 0 In 1 ft4 in
0.65 0.25 8.0 ft2 1 ft0 in 1 ft 4 In
None
None
None
None
None
None
None
None
None
None .
None
None
None
None
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000254
538 29.54 55.55 .1855 5
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Strip Heat
None
COP:1 17 kBtuthr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit
Split
SEER: 16 18 kBtumr cfm 0.8 1
sys#1
HOT .WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric Tankless
Exterior
0.9 1 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ftZ
DUCTS
— Supply —
# Location R Value Area
— Return — Air CFM 25 OFM26
Location Area Leakage Type Handler TOT OUT
QN. RLF
HVAC #
Heat Cool
1 Attic 6 200 ft2
Attic
60 ft2 Default Leakage GREAT RO (Default) (Default)
1 1
3/10/2016 8:53 AM EnergyGauge® USA- FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
t-UKM K4U5-Lu'I�F
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling ] Jan
Heating (X] Jan
[ Feb
[X] Feb
Mar
LX] Mar
r
r
Ar
(
[
May
May
I
(X Jun
i Jun
�( Jul
i JUI
�C] Aug
i I Aug
(� Se
j j Sep
r 1 Oct
[ ]Oct
Oct
r Nov
(X] Nov
Nov
Dec
Dec
Dec
Venting III III Jan
[[ ]] Feb
LX1l Mar
[
May
[[ ]]] Jun
[ ]]] Jul
[ ] Aug
[ ] Se
[[[XXXIII
[[XX]]
Thermostat Schedule:
HERS 2006 Reference
Hours
8
9
10
11
12
Schedule Type
1
2
3
4
5
6
7
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)
PM
78
78
78
78�
78
78
78
78
78
78
78
78
Heating(WD)
PM
68
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH)
PM
68
68
68
68
68
8
68
68
68
68
66
66
3J101=6 8:53 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014 TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: McGHEE RESIDENCE Builder Name:
Street: 689 NETTLES BLVD. Permit Office:
City, State, Zip: JENSEN BEACH, FL, Permit Number.
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the' air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
Insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Comers and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be,sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed,
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawispace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
s aces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
harrier instnnPd sanaratina them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
3110/2016 8:53 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
689 NETTLES BLWD., JENSEN BEACH, FL,
1. New construction or existing
New (From Plans)
9. Wall Types
Insulation
Area
a. Concrete Block - Ext Insul, Exterior
R=4.1
966.67 ftz
2. Single family or multiple family
Single-family
b. Frame -Wood, Exterior
R=11.0
120.00 ftz
3. Number of units, if multiple family
1
c. NIA
R=
ftz
1
�
d. WA
R=
ftz
4. Number of Bedrooms
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
Yes
a. Under Attic (Vented)
R=30.0
807.00 ftz
6. Conditioned floor area (ftz)
807
1
b. WA
R=
R=
ftz
ftz
c. NIA
7. Windows" Description
Area
11. Ducts
R ftz
a. U-Factor: S91, U=0.65
92.17 ftz
a. Sup: Attic, Ret: Attic, AH: GREAT ROOWKIT.
6 200
SHGC: SHGC=0.25
b. U-Factor: NIA
ftz
12. Cooling systems
kBtu/hr
Efficiency
SHGC:
c. U-Factor: NIA
ftz
a. Central Unit
18.0 SEEM 6.00
SHGC:
d. U-Factor: NIA
ftz
13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
17.0
COP:1.00
Area Weighted Average Overhang Depth:
1.000 ft.
Area Weighted Average SHGC:
0.250
8. Floor Types
Insulation
Area
14. Hot water systems
Cap:1 gallons
a. Crawlspace
R=19.0
806.50 ftz
a. Electric
EF: 0.9
b. N/A
R=
ftz
b. Conservation features
c. NIA
R=
ftz
None
15. Credits
OF, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. (�
,Builder Signature: Date: 7J 1
.Address of New Home; City1FL Zip:
`Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficien
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Rat rs ago
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commlt-'s
support staff.`
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if'
311012016 8:63 AM EnergyGauge® USA- FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
- - vwrightsoft® Project Summary
Entire House
QUICK CALCS; INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@}AOL.COM
® o •
For: McGHEE RESIDENCE
689 NETTLES BLVD., JENSEN BEACH, FL
_--Desi: "n l.nfo:rma-tionL-._n-. --
Weather.
Winter Design Conditions
Outside db
42
OF
Inside db
70
OF
Design TD
28
OF
Heating Summary
Structure
9159
Btuh
Ducts
2607
Btuh
Central vent (16 cfm)
480
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
12246
Btuh
Infiltration
Method
Construction quality
Fireplaces
Fort Pierce, FL, US
Simplified
Average
0
Heating
Cooling
Area (ft2)
807
807
Volume (ft3)
6452
6452
Air changesthour
0.61
0.32
Equiv. AVF (cfm)
66
34
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
5.1 kW
17448 Btuh
26 OF
600 cfm
0.051 cfm/Btuh
0 in H2O
Job:
Date: Feb 24, 2016
By:
Summer Design Conditions
Outside db
90 OF
Inside db
75 OF
Design TD
15 OF
Daily range
L
Relative humidity
50 %
Moisture difference
61 gr/Ib
Sensible Cooling Equipment Load Sizing
Structure
8955
Btuh
Ducts
4010
Btuh
Central vent (16 cfm)
257
Btuh
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Equipment sensible load
12561
Btuh
Latent Cooling Equipment
Load Sizing
Structure
1437
Btuh
Ducts
1080
Btuh
Central vent (16 cfm)
651
Btuh
Equipment latent load
3169
Btuh
Equipment total load
15730
Btuh
Req. total capacity at 0.70 SHR
1.5
ton
Cooling Equipment
Summary
Make Rheem
Trade RHEEM; RUUD
Cond RA1618AJ1
Coil RH1T2417STAN
AHRI ref 7940565
Efficiency
13.0 EER, 16 SEER
Sensible cooling
Latent cooling
12600 Btuh
5400 Btuf�,
Total cooling
18000
Actual air flow
1
Airflow factor
0.
Static pressure
F'*m.
,� u n
Load sensible heat ratio k
Calculations approved byACCA to meet all requirements of Manual J 8th E .
Wriih�� 9tsot` 2016-Mar-0111:30:15
MCP. Right -Suite® Universal 2015 15.0.19 RSU08101 Page 1
..sers\Quick Calcs\Documents\McGHEE RESIDENCE.rup Calc = MJ8 Front Door faces: N
7El I F wrightsoft, Right-M Worksheet Job:
Entire House Date: Feb 24, 2016
By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Ema;l: QUICKCALCS@40LCOM
1
Room name
Entire House
GREAT ROOWWT.
2
Exposed wall
135.7 ft
67.2 ft
3
Room height
8.0 ft d
8.0 ft heat/cool
4
5
Room dimensions
Room area
806.5 1112
1.0 x 375.5 ft
375.5 f?
Ty
Construction
U-value
Or
HTM
Area (ftj
Load
Area (ftj
Load
number
(Btuh/ft�`F)
(Btuh/ft')
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Pros
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
13A-4o s
2 glazing, cir outr,
2 glazing, cir outr,
0,143
0.650
0.650
n
n
n
4.00
18.20
18.20
2.55
23.80
23.80
217
9
15
178
0
0
714
159
273
454
208
357
201
9
15
162
0
0
650
159
273
413
208
357
N
w
11
2 glazing, cir outr,
13AAocs
0.650
0.143
_n
a
18.20
4.00
23.80
2,55
15
352
0
352
281
1409
367
896
15
120
0
120
281
480
367
305
YN
T-D
1213-0sw
11D0
13A-4ocs
0.097
0.390
0.143
s
s
s
2.72
10.92
4.00
2.58
, 11.31
2.55
88
21
96
67
21
59
• 182
229
236
173
238
150
0
0
16
0
0
2
0
0
8
0
0
5
2 glazing, cir low-e
2 glazing, clr low-e
0.650
0.650
s
s
18.20
18.20
14.99
14.99
8
15
8
15
146
273
120
225
0
0
0
0
0
0
0
0
w
11DO
1213-0sw
13A-4ocs
0.390
0.097
0.143
s
w
w
10.92
2.72
4.00
11.31
2.58
2.55
14
i 32
301
14
32
271
153
87
1086
158.
83
690
14
0
120
14
0
105
153
0
420
158
0
267
2 glazing, clr low-e
2 glazing, cir outr,
0.650
0.650
w
w
18.20
18.20
33.77
74.13
15
15
0
0
273
273
507
1112
0
15
0
0
0
273
0
1112
C
F
16A-Md
19A30cvtp
0.032
0.034
-
-
0.90
0.80
2.32
0.43
807
807
;
,
i
i
i
807
807
723
644
1871
345
376
376
376
376
336
300
871
161
6
c)AED emursion
4351
273
Envelope loss/gain
7141
8388
3334
4498
12
a) Infiltration
b) Room ventilation
2019
0
567
0
850
0
239
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
9159
8955
4184
4737
14
15
Less edemal load
Less transfer
Redistribution
Subtotal
Duct loads
28%
450/6
0
0
0
9159
2607
0
0
0
8955
4010
28%
45%
0
0
0
4184
1191
0
0
0
4737
2121
7
Total room load
Air required (cfm)
11766
600
12965
600
5374
274
6857
317
Calculations approved by_ACCA to meet all requirements of Manual J 8th Ed
4 wriEjhtsoft' Right -Suite® Universal 2015 15.0.19 RSU08101 2016-Mar-01 11:30:15
Page 1
...sers\Quick Calcs\Documents\McGHEE RESIDENCE.rup Caic = MJB Front Door faces: N
wrilghtsoft° Right-J® Worksheet Job:
Entire House Date: Feb 24, 2016
By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax: 772466-6796 Ernail: QUICKCALCS@AOL.COM
1
Room name
BATH 2
DEN
2
3
Bposed wall
Room height
6.0 ft
&0 ft heat/cool
25.0 ft
8.0 ft heat/cool
4
5
Room dimensions
Room area
7.0 x 6.0 ft
42.0 ft2
10.0 x 11.0 ft
110.0 ft2
Ty
Construction
number
U-value
(Btuh/WVF)
Or
HTM
(Btuh/ft2)
Area OF)
or perimeter (ft)
Load
(Btuh)
Area (ft)
or perimeter (ft)
Load
(Btuh)
Heat
I Cool
Gross
N/PIS
Heat
Cool
Gross
N/P/S
Heat
Cool
6
13A flocs -
2 glazing, cir outr,
2 glazing, cirouU,
Q,143
0.650
0.650
n
n
n
4.00
18.20
1&20
.' + 2.55
, 23.80
23.80
0
.' 0
0
0
0
_0
0
0
.. .. 0
0
0
, 0
0
0
O
0
0
0
0_
0
0
11
2 glazing, cir out:, _
13A4ocs
12B-0sw
11D0 ' - -
13A-4ocs
2 glazing, cir low-e
2 glazing, cir low-e
0.650
0.143
0.097
0.390
0.143
0.650
0.650
_ " n_ '
a
s,.
s
s
s
s
18.20
4.00
2.72
_ 10.92
4.00
18.20
18.20
M.80
2-55
2.58
. - 11.31
2.55
14.99
14.99
� 0
48
0
'0:
I 0
0
0
0
48
0.
0
0
0
0
0
_ - _-- 192
' 0
.. 0
0
0
0
0
122
0
0
0
0
0
0
_ - 88
0
0'
80
0
15
. 0
88
0
0
65
0
15
0
352
0
-0
260
0
273
0
224
0
0'
165
0
225
w
11DO _- _. _
12B-0sw.' -'
0'.390
0:097•
s
- ,w ,
_ 10.92
2.72
11.31
. ... 2.58
0
1. , .:0
0
0,
_0
_ . , 0-
- .0.
0_
_ 0
, ° . ` 12
0
... .. _ 32
- - - 0
, 87
0
83
W
V�!
13A-4ocs
0.143
w
4.00
2.55
0
0
0
0
0
0
0
0
2 glazing, cir low-e
2_glazing, ciroutr,
0.650
w
w
18.20
1.8.20
33.77
74.13
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
C "..
16A30td; .
_0.650
0.032
-.
'. •:. 0.90
_
` 2.32
42'
_,.
42
_
... 38
. 97
_
.. 110
_ _
110
_
99
255
F
19A30cvtp-
0.034
-
_ . ,0.80
_
... 0.43
i 42
42
34
-_ 18
- 110
._ 110
. 88
... 47
- -
_
_
-
6
c)AED excursion
i
3
-9
Envelope loss/gain
263
235
1159
991
12
a) Infiltration
89
25
372
104
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
353
260
1530
1095
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
353
260
1530
1095
15
DuctloadS
28%
45%
100
116
28%
45%
436
490
17
Total room load
453
3T7
1
1966
1565
Air required (cfm)
23
17
100
73
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed.
411- wrightsoft- Right -Suite® Universal 2015 15.0.19 RSU08101 2016 Mar-01 11P'-
3015
I&K age 2
... sers\Quick Calcs\Documents\McGHEE RESIDENCE.rup Calc = MJB Front Door faces: N
Al-
9- wrightsoft' Right-M Worksheet
Entire House
QUICK CALCS, INC.
317 ST. LUCIE W., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM
Job:
Date: Feb 24, 2016
By:
1
Room name
BEDROOM
HALL
2
Exposed wall
120 ft
4.0 ft
3
Room height
8.0 it heat/cool
8.0 ft heat/cool
4
Room dimensions
11.0 x 10.0 ft
1.0 x 61.0 ft
5
Room area
110.0 ft2
61.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft-)
Load
number
(Btuh/ftl °F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/PIS
Heat
Cool
6
13A flocs
2 glazing, cir outr,
2 glazing, cir outr,
0.143
0:650
0.650
n
n
n
4.0
18.220
18.20
2.
23.8080
23.80
16
', 0
0
16
0
0
64
0
0
41
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Its----GGG
2 glazing, cir outr,
0.650
n
18.20
23.80
0
0
0.
0
0
0
0
0
W
11
13A-4ocs
0.143
a
4.00
2.55
0
0
0
0
0
0
0
0
T-D
12B-0sw
11D0
0.097
0.390
s
s
2.72
10.92
2.58
11.31
0
0
0
0
0
0
0
0
32
21
11
21
30
229
28
238
'h
13A-0acs
0
s
4.
2.
0
0
0
0
0
0
0
0
2 glazing, cir low-e
2 glazing, clr low-e
0.650,650
0.650
s
s
18.2020
18.20
14.9999
14.99
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11DO
1213-0sw
13A4ocs
0.390
0.097
0.143
s
w
w
10.92
2.72
4.00
11.31
2.58
2.55
0
0
80
0
0
65
0
0
260
0
0
165
0
0
0
0
0
0
0
0
0
0
0
0
W
2 glazing, clr low-e
2 glazing, clr outr,
0.650
0.650
w
w
18.20
18.20
33.77
74.13
15
0
0
0
273
0
507
0
0
0
0
0
0
0
0
0
C
16A30td
0.032
-
0.90
2.32
110
110
99
255
61
61
55
142
F
19A30cvtp
0.034
-
0.80
0.43
110
110
88
47
61
61
49
26
6
c)AED excursion
189
4
Envelope loss/gain
784
1204
363
429
12
a) Infiltration
178
50
59
17
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
962
1254
422
446
Less external load
0
0
0
0
14
Less transfer
Redistribution
Subtotal
0
0
962
0
0
1254
0
0
422
0
0
446
15
Duct loads
28%
45%
274
562
28%
45%
120
200
Total room load
Air required (cfm)
F1236
63
1816
84
542
28
645
30
Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed.
wrsit g~s®ft Right -Suite® Universal 2015 15.0.19 RSU08101 2016-Mar-01 11
�0> Page 3
...sers\Quick Calcs%DocumentslMcGHEE RESIDENCE.rup Cale = MJ8 Front Door faces: N 9
-�+ wrights®ft Right-J® Worksheet Job:
Entire House Date: Feb 24, 2016
QUICK CALCS, INC. By:
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
WIC
MASTER BATH
2
E)q)osed wall
6.3 ft
25.3 ft
3
Room height
8.0 ft heat/cool
8.0 ft heat/cod
4
5
Room dimensions
Room area
1.0 x 30.0 ft
30.0 ft'
1.0 x 78.0 ft
78.0 ftz
Ty
Construction
U-value
Or
HTM
Area (ft)
Load
Area (W)
Load
number
(Btuh/ftz-°F)
(Btutff)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/PIS
Heat
Cool
6
13A4ocs
2 glazing, cir outr,
.2 glazing, cir outr,
0.143
0.650
0.650
n
n
n
4.00
18.20
18.20
2.55
23.80
23.80
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
w
2 glazing, cir outr,
13A-4ocs
0.650
0.143
n
e
18.20
4.00
. 23.80
2.55
0
0
0
0
0
0
0
0
0
96
0
96
0
384
0
244
V!/
L-D
Vl/
126-0sw
11DO
13A-4ocs
0.097
0.390
0.143
_
s
s
s
2.72
10.92
4.00
2.58
11.31
2.55
0
0
0
D
0
0
0
0
0
0
0
0
56
0
0
56
0
-8
152
0
32
144
0
-20
2 glazing, cir low-e
2 glazing, clr low-e
0.650
0.650
s
s
18.20
18.20
14.99
14.99
0
0
0
0
0
0
0
0
8
0
8
0
146
0
120
0
11DO
12B-0sw
13A-4ocs
0.390
0.097
0.143
s
w
w
10.92
2.72
4.00
11.31
2.58
2.55
0
0'
51
0
0
51
0
0
203
0
0
129
0
0
51
0
0
51
0
0
203
0
0
129
w
2 glazing, cir low-e
2 glazing, cir outr,
0.650
0.650
w
w
18.20
18.20
33.77
74.13
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
C
F
16A-30td
19A-30cvtp
0.032
0.034
-
-
0.90
0.80
2.32
0.43
30
30
30'
30
27
24
70
13
_ 78
78
78
78
70
62
181
33
6
c)AED excursion
-2
-9
Envelope loss/gain
253
Y09
1
985
822
12
a) Infiltration
b) Room ventilation
94
0
26
0
376
0
106
0
13
Internal gains: Occupants @ 230
Appliances/other
0
0
0
0
0
0
Subtotal (lines 6 to 13)
347
235
1361
928
14
15
Less extemal load
Less transfer
Redistribution
Subtotal
Duct loads
28%
45%
0
0
0
347
99
0
0
0
235
105
28%
45%
0
0
0
1361
387
0
0
0
928
416
Total room load
Air required (cfm)
446
23
341
16
1749
89
1344
62
Calculations approved bVACCA to meet all requirements of Manual J 8th Ed
� A � wrightsoft- Right-Sulte® Universal 2015 15.0.19 RSU08101 2016-Mar-01 11:30:15
...serslQuick Calcs\DocumentslMcGFiEE RESIDENCE.rup Calc = M.18 Front Door faces: N
Page 4