Loading...
HomeMy WebLinkAboutREVISION 7-26-16i RECEI'.'r-D JUL 2 6 2016 OFFICE USE ONLY: DATE FILED: -\ Vases\ w N PERMIT # REVISION FEE: i '�. �Q LUCI@ eooQfl� RECEIPT #�1 1 L n 1. 2. 3. 4. PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DMSION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 772) 462-1553 FAX (772) 462-1578 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION I LOCATION/SITE ADDRESS: Ccl r.J �-�G �C, �• `��i-N ��', �'�'C' I I DETAILED DESCRIPTION OF PROJECT REVISIONS: I 1 I CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: `Z-1 ST. LUCIE COUNTY CERT. #: BUSINESS NAME: fA LL^ 1 S O QUALIFIERS NAME: `M ADDRESS: L OctS CITY: e, I STATE: PHONE (DAYTIME) FAX: Z 22 OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE: 5. ARCHITECT/K NAME: ADDRESS: CITY: PHONE (DAYT] Revised 07/22/2014 STATE: ZIP: S 7 fl, W-ISION FILE COPY t'EI"7D Alin 012016 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: McGHEE RESIDENCE Builder Name: Street: 689 NETTLES BLVD. Permit Office: City, State, Zip. JENSEN BEACH, FL, Permit Number. Owner: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (1086.7 sqft) Insulation Area a. Concrete Block - Ext Insul, Exterior R=4.1 966.67 ftz 2. Single family or multiple family Single-family b. Frame - Wood, Exterior R=11.0 120.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 1 d. N/A R= ft2 10. Ceiling Types (807.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Roof Deck (Unvented) R=20.0 807.00 ft2 6. Conditioned floor area above grade (ft2) 807 i b. N/A R= ft2 c_ N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(92.2 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: GREAT ROOMIKIT. 6 200 a. U-Factor. Sgl, U=0.65 9119 ft2 SHGC: SHGC=0.25 ft2 12. Cooling systems kBtu/hr Efficiency b. U-Factor: N/A a. Central Unit 18.0 SEER:16.00 SHGC: c. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ftz a. Electric Strip Heat 17.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (806.5 sqft.) Insulation Area EF: 0.900 a. Crawlspace R--19.0 806.50 ft2 b. Conservation features b. N/A R= ft2 None c. NIA R= ft2 15. Credits CF, Pstat Total Proposed Modified Loads: 31.77 Glass/Floor Area: 0.114 Total BaselinePASS Loads: 32.55 1 hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energyspecific� Review of the plans and pF KNE Sr42 ' p e �r �di, �Ot� "i sdk Code. calculatl�� with th0f0R 0T AN�Y COO T. Before PREPA ED BY: - - - DATE: c v It bt'�d'rl���� this bull its _ a comp q go MANY IN I hereby certify that this building, as designed_ , is in compliance Florida Y. 11, l At'AI APPUCAO ' with the Florida Energy Code." OWNER/AGENT: - __ __ BUILDING OFFICIAL: - - - DATE: �� - DATE: --- --- - - Compliance requires certification y the air handier unit manufacturer that the air handler enclosure.qualifies as certified factory -sealed in accord h R 1. - Compliance �J 1 sppection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in aR�tycffll 4� ' ' DSiCN LAl' C RE VIEWED B 1 DATE PLAN S AiAi'1D E T ST BE KEPT ON jrmn 0111 NO 1NSPJECT10,N tiVILL BE MADE. 6/20/2016 5:12 PM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Softwar COPgYof6 CrIPKA RAns;—Inlll PROJECT Title: McGHEE RESIDENCE Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 807 Lot # Owner: Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 45 Street: 689 NETTLES BLVD. Permit Office: Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: JENSEN BEACH, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp % 2.5 % Int Design Temp Heating Winter Summer Degree Days Design Daily Temp Moisture Range Design Location TMY Site Zone 97.5 FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Entire House 807 6456 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 GREAT ROOMIKIT. 376 3008 Yes 0 1 Yes Yes Yes 2 BATH 2 42 336 No 0 1 Yes Yes Yes 3 DEN 110 880 No 0 1 Yes Yes Yes 4 BEDROOM 110 880 No 1 1 1 Yes Yes Yes 5 HALL 61 488 No 0 1 Yes Yes Yes 6 WIC 30 240 No 0 1 Yes Yes Yes 7 MASTER BATH 78 624 No 0 1 Yes Yes Yes FLOORS # Floor Type _Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Crawlspace GREAT ROOMIKI 57.2 ft 0 375.5 ft2 19 0 1 0 2 Crawlspace BATH 2 eft 0 42 ft2 19 0 1 0 3 Crawlspace DEN 25 ft 0 110 ft2 19 0 1 0 4 Crawlspace BEDROOM 12 ft 0 110 ft2 19 0 1 0 5 Crawlspace HALL O ft 0 61 ft2 19 0 1 0 6 Crawlspace WIC 6.3 ft 0 30 ft2 19 0 1 0 7 Crawlspace MASTER BATH 25.3 ft 0 78 ft2 19 0 1 0 6/20/2016 5:12 PM EnergyGauge® USA - FlaRes2014 Section R405A.1 Compliant Software Page 2 of 5 CnDRA DAnr,-,) 14A ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 874 ft2 168 ft2 Light 0.6 No 0.9 No 20 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS 1RCC 1 Full attic Unvented 0 807 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Unvented) GREAT ROOM/KI 20 376 ft2 0.1 Wood 2 Under Attic (Unvented) BATH 2 20 42 ft2 0.1 Wood 3 Under Attic (Unvented) DEN 20 110 ftz 0.1 Wood 4 Under Attic (Unvented) BEDROOM 20 110 ft2 0.1 Wood 5 Under Attic (Unvented) HALL 20 61 ft2 0.1 Wood 6 Under Attic (Unvented) WIC 20 30 ft2 0.1 Wood 7 Under Attic (Unvented) MASTER BATH 20 78 ft2 0.1 Wood WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below 1/ -Omt---To- - Wall -Type Spate R-Value-Et-tn- _Ft,in Area-__R-Value Fraction -Absoc._.Grade%- 1 N=>NE Exterior Concrete Block - Ext InGREAT ROO 4.I1 25 2 8 0 201.3 ft2 0 0 0.8 0 _ 2 E=>SE Exterior Concrete Block - Ext InGREAT ROO 4.i1 15 0 8 0 120.0 ft2 0 0 0.8 0 _ 3 S=>SW Exterior Concrete Block - Ext Ina%REAT ROO 4.11 2 0 8 0 16.0 ft2 0 0 0.8 0 _ 4 W=>NW Exterior Concrete Block - Ext InGREAT ROO 411 15 0 8 0 120.0 ft2 0 0 0.8 0 _ 5 E=>SE Exterior Concrete Block - Ext Insul BATH 2 4.1 6 0 8 0 48.0 ft2 0 0 0.8 0 _ 6 E=>SE Exterior Concrete Block - Ext Insul DEN 4!1 11 0 8 0 88.0 ft2 0 0 0.8 0 _ 7 S=>SW Exterior Concrete Block - Ext Insul DEN 40 10 0 8 0 80.0 ft2 0 0 0.8 0 _ 8 W=>NW Exterior Frame - Wood DEN 1j1 4 0 8 0 32.0 ft2 0 0.25 0.8 0 _ 9 N=>NE Exterior Concrete Block - Ext InsI3EDROOM 4!.1 2 0 8 0 16.0 ft2 0 0 0.8 0 _ 10 W=>NW Exterior Concrete Block - Ext Ins1HEDROOM 4�1 10 0 8 0 80.0 ft2 0 0 0.8 0 _ 11 S-SW Exterior Frame - Wood HALL 1 4 0 8 0 32.0 ft2 0 0.25 0.8 0 _ 12 W=>NW Exterior Concrete Block - Ext Insul WIC 4.1 6 4 8 0 50.7 ft2 0 0 0.8 0 _ 13 E=>SE Exterior Concrete Block - Ext IndVASTER BA 4.1 12 0 8 0 .96:0 ft2 0 0 0.8 0 _ 14 S=>SW Exterior Frame - Wood MASTER BA 11 7 0 8 0 56.0 ft2 0.25 0.8 0 15 W=>NW Exterior Concrete Block - Ext InEMASTER BA 4.1 6 4 8 0 50.7 ft2 0 0 0.8 0 DOORS # Ornt Door Type Space Storms U-Value WidthArea Ft In In Ft i S=>SW Insulated GREAT ROO None .39 2 7 14 ft2 2 S=>SW Insulated HALL None .39 3 7 21 ft2 6/2012016 5:12 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 CllE5lf9 E3An= nA4A � WINDOWS Orientation shown is the entered orientation (_> changed to Worst Case. Wall Overhang # Ornt ID Frame Panes V - _ _ NFRC — U-Factor SHGC Area Depth Separation _ _ ._ Int Shade ' Screening -- 1 N=>NE 1 Metal Low -It Single Yes 0.65 0.25 8.8 ft2 1 ft 0 in 1 ft 4 in None None 2 N=>NE 1 Metal Low-E Single Yes 0.65 0.25 15.0 ft2 1 ft 0 in 1 ft 4 in None None 3 N=>NE 1 Metal Low-E Single Yes 0.65 0.25 15A ft2 1 ft 0 in 1 ft 4 in None None 4 W=>NW 4 Metal Low-E Single Yes 0.65 0.25 15.0 ft2 1 ft 0 in 1 ft 4 in None None 5 S=>SW 7 Metal Low-E Single Yes 0.65 0.25 15.0 ft2 1 ft 0 in 1 ft 4 in None None 6 W=>NW 10 Metal Low-E Single Yes 0.65 0.25 15.0 ft2 1 ft 0 in 1 ft 4 in None None 7 S=>SW 7 Metal Low-E Single Yes 0.65 0.25 8.0 ft2 . 1 ft 0 in 1 ft4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) `.000254 538 29.54 55.55 .1855 5 i HEATING SYSTEM # System Type _ Subtype Efficiency _ _Capacity Block Ducts 1 Electric Strip Heat None COP:1 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type_ _ Subtype Efficiency Capacity Air Flow _ SHR Block Ducts 1 Central Unit Split SEER: 16 18 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe --, Location EF Cap Use SetPnt _ _ Conservation 1 Electric Tankless Exterior 0.9 1 gal 60.9 gal 120 deg None SOLAR HOT,WATER SYSTEM i FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply -- — Return - - Air CFM 25 CFM25 HVAC # i/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 200 ft2 Attic 60 ft2 Default Leakage GREAT RO (Default) (Default) 1 1 j.. A �, I � 1 �r.•y J 6/20/2016 5:12 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 N O O 'm v� N m m 0 G) w C tCl D m m v, A N 2 0 A O p A 0 O w w fD -n 3:mooS cD i n M ' "G Sc D 7C 32 D dto �. � to 7 7 to a 0 •7".0 o (C N A ttG tG m 0 m 0 .�+ N a cn 2 = m � CD N I CCD LLL � N m '= �D oD vD vD fin -m- c ovCD c' 0 M OD OD mm ow 1 ^ wain N OOW OMDM co co Om i -� 00 mM MM VN -4-4 W mM mo) mM mm 0 m MM MO) -4-4 -4-4 1 A •c�.we� v m Mw MM mm Mm 0 O7 ,c C G O)m Mm MCA mm -IV wou -(-I mm eft =3 +� -I • C rn I. Mm MM VV VV Mw Coco mM M m O C C: C MM MM VV -1V V OOm ODOO Cow co co C C C f0(G f0 MM 00) OD MM wOD OVDm Mw CT T _M I mm MOD 00 Mm V.I wm Vm w0 000 gam Mm mM MM mM V-4 mM -Iw MO o V-)Z- ZZZ MO) 01M V-1 -100 -. Cow Cow mm Mo stOD �OMD mm-IM I m 000 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 689 NETTLES BLVD., JENSEN BEACH, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 966.67 ft2 b. Frame -Wood, Exterior R=11.0 120.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 1 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? Yes a. Roof Deck (Unvented) R=20.0 807.00 ft2 6. Conditioned floor area (ft2) 807 b. N/A R= ft2 7. Windows" Description Area c. NIA R= ft2 a. U-Factor: Sgl, U=0.65 92.17 f12 11. Ducts R ft2 SHGC: SHGC=0.25 a. Sup: Attic, Ret: Attic, AH: GREAT ROOM/KIT. 5 200 b. U-Factor: WA ft2 SHGC: 12. Cooling systems kStu/hr Efficiency c. U-Factor. N/A ft2 a. Central Unit 18.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kStu/hr Efficiency SHGC: a. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems Cap: 1 gallons a. Crawlspace R=19.0 806.50 ft2 a. Electric EF: 0.9 b. N/A R= ft2 c. NIA R= ft2 b. Conservation features None 15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building '(NE sra � Construction through the above energy saving features which will be installed (or exceeded) �o=.'° in this home before final inspection. Otherwise, a new EPL Display Card will be P p Yam" based on installed Code compliant features. „ate Builder Signature: Date: -7 Address of New Home: �jcj �'V`L_ City/FL Zip: x�4vg'� e yes �YL *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, i E 'WL' 6/20/2016 5:18 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Softwa __ 1 f 1 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: McGHEE RESIDENCE Builder Name: Street: 689 NETTLES BLVD. Permit Office: City, State, Zip: JENSEN BEACH, FL, Permit Number: Owner. Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope' insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawispace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be airtight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be' installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace a An air barrier shall be installed on fireplace walls. Fireplaces R1 f fig V gasketed doors 6/20/2016 5:12 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software E l N MURN W PageM of 1 °bPro Project t)—,,ima 4wrightso Date: Feb 24, 2016 Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 ,Efnail:'QUIdKCALCS@AOL.COM • • • For. McGHEE RESIDENCE 689 NETTLES BLVD., JENSEN BEACH, FL Notes: Design Bn-formation Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 9715 Btuh Structure 8092 Btuh Ducts 2607 Btuh Ducts 4010 Btuh Central vent (16 cfm) 480 Btuh Central vent (16 cfm) 257 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12802 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load. 11741 Btuh Method Simplified I Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1437 Btuh Ducts 1080 Btuh Heating Cooling Central vent (16 cfm) 651 Btuh Area (ftz) 807 807 Equipment latent load 3169 Btuh Volume (ft3) 6452 6452 Air changes/hour 0.61 0.32 Equipment total load- 14910 Btuh Equiv. AVF (cfm) 66 34 Req. total capacity at 0.70 SHR 1.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM;.RUUD Model Cond RA1618AJ 1 AHRI ref Coil 'RH1T2417STAN AHRI ref 7940565 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 5.1 kW Sensible cooling - 12600 Btuh Heating output 17448 Btuh Latent cooling 5400 Btuh Temperature rise 26 OF Total cooling . 18000 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio . 0.80 bes'� ` Calculations approved byACCA toimeet all requirements of Manual JF .4C-��- wrightsoft° C�. Right -Suite® Universal 2017 17.0.03 RSU08101 ...sers%Quick CalcsTocuments%McGHEE RESIDENCE.rup Calc = MJ8 Front Door faces: N I Page 1 -�- wrightsoft' MOW(, ,forksheet at Entire House Date: Feb 24, 2016 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House GREAT ROOM/KIT. 2 Exposed wall 135.7 ft 57.2 ft 3 Room height 8.0 ft d 8.0 ft heat/cool 4 5 Room dimensions Room area 806.5 ft2 1.0 x 375.5 ft 375.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuhfftk°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 2 glazing, cir outs 2 glazing, cir outr, 0.143 0.650 0.650 ri n n 4.66 18.20 18.20 _ 2.66 23.80 23.80 217 9 15 178 0 0 714 159 273 464 208 357 201 9 15 162 0 0 650 159 273 413 208 357 --G �L---�G 11 2 glazing,_clr outr, .. 13A-4ocs 0.650 0.143 n. a ... 18.20 4.00 23.80 2.55 15 352 . 0 352 281 1409 367 896 15 120 0 120 281 480 367 305 w Ut/ L-D 12B-0sw 1100 13A-4ocs 0.097 0.390 0.143 s s s 272 10.92. 4.00 2.58 11.31 2.55 i 88 21 96 67 21". 59 182 _ 229 236 173 _ _238 150 0 0 16 0 0 2 0 0. 8 0 0 5 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 s s 18.20 18.20 14.99 14.99 8 15 8 15 146 273 120 225 0 0 0 0 0 0 0 0 w W 11D0 12&0sw 13A4ocs 0.390, 0.097 0.143 s . w w 10.92 2.72 4.00 11.31 2:58 2.55 ..., , 14 . ? 32 301 14 .. 32 271 153 87 1086 158 _ 83 690 14 0 120 �0 105 `,. .1'0 420 1 . ... 0 267 2 glazing, cir low-e 2 glazing, cir outr, 0.650 0.650 w w 18.20 18.20 33.77 74.13 15 15 0 0 273 273 507 1112 0 15 0 0 0 273 0 1112 1�----GG C 16M-Otd. , , , , _ 0.408 1.59 1.25 807 807 1219 1008 376 376 _ '595 _ 469 F 19A-30cvtD 0.034 - 0.80 0.43 807 807 644 345 376 376 360 161 t 6 c)AED excursion 435 272 Envelope loss/gain 7697 7525 3593 4095 12 a) Infiltration 2019 567 850 239 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 9715 8092 4442 4334 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 9715 8092 4442 4334 15 Duct loads 27% 50% 2607 4010 27% 50% 1192 2148 Total room load 12322 12102 5634 6482 Air required (cfm) 600 600 , �_ .. .„w 274 321 -F A- wrightsoft` " "" x 20f6-Jhn-20`f7:14:07 �A Right -Suite® Universal 2017 17.0.03 RSU08101 Page 1 ...sers\Quick Calcs\Documents\McGHEE RESIDENCE.rup Calc = MJ8 Front Door faces: N -+ - vvrightsoft• Right-JG__, ;lorksheet _ °b Entire House Date: Feb 24, 2o1s By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466.6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH 2 DEN 2 E:gmed wall 6.0 ft 25.0 ft 3 Room height 8.0 ft heat/cod 8.0 ft heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42 0 ft2 10.0 x 11.0 ft 110.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftz°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cod Gross NIP/S Heat Cod 6 , .: 13A-4ocs -,-0.143 2 glazing; cir outr, 2 glazing, cir outr, 0.650 0.850 � m` n n 4:00 18.20 18:20 ..2.55 '. 23.80 23.80 _ i .,.0 0 '0".0 .. ... ..O 0 ....._ _.. o 0 0 ..... ._. 0 0. 0- _ . .._....0 0 0 .. .. _0 0 0 .. 0 0 0 ... _ -0 0 0 w 11 2 glazing, cir outr,_ _ 13A4ocs -0.650 0.143 ; , n, a 18.20 4.00 .. 23.80 2.55 . . , . 6, 48 ... 0 48 _ 0 192 '0., 122 0 88 _ ........ 0 88 .. ...... ;0 352 0 224 VN L, D 12B-0sw 1100 13A-4ocs 0.097 0.39D 0.143 s s: s 272 10.92 4.00 2.68 . 11.31 2.55 _ i 0 0 0 0 0 0 0 0. 0 0 0 0 0 ., 0 80 0 0 65 0 0. 260 0 0 165 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 s s 18.20 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 15 0 15 0 273 0 225 W 1100 12B-0sw .. 0.390 0.097 s w • 10.92 2.72 , . 11.31 -2 ' 58 , . . 0 _ 0 , _0 . 0:- 0 _ 0 0 ._ 0 _ _ 0 32 , _ 0 - 32 . - 0 _ _ , . 87 0 . 83 T-A 13A-flocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, cir outr, 0.650 0.650 w w 18.20 18.20 33.77 74.13 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ C 16XI0. d _. _ 0.408 _ - 1.50 1.25 _ 42 42' 67 53 110 . , 110 . _ 174 138 F 19A-30cvtp 0.034 , - 0.80 . . _ ,`0.43 42 42 34 18 _ . 110 . 110 . _ 88 47 6 c) AED excursion -2 -9 Envelope loss/gain 292 190 1235 873 12 a) Infiltration 89 25 372 104 b) Room ventilation 1 0 0 01 0 13 Internal gains: Occupants @ 230 0 0 0 0 1 Appliances/other 0 0 Subtotal (lines 6 to 13) 382 215 1606 977 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 382 215 1606 977 15 Duct loads 27% 50% 102 107 27% 59.2., ,,. 484 Total room load 484 322 ` 1462 Air required (cfm) 24 16 72 r �6kj �,,, n t Calculations approved byACCA to meet all requirements of Manual J 8th Ed. AAA - wrightsoft` Right -Suite® Universal 2017 17.0.03 RSU08101 2016ti1un-Jun1Page 2 ...sers%Quick Calcs\DocumentslMcGHEE RESIDENCE.rup Calc = MJ8 Front Door faces: N 9 -� - Wrightsoft' Right4l, _ Jorksheet Date: Entire House Date: Feb 24, 2o�s By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name BEDROOM HALL 2 Exposed wall 12.0 ft 4.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 11.0 x 10.0 ft 110.0 ft2 1.0 x 61.0 ft 61.0 f12 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (13tuh/ft2) or perimeter (ft) (Stuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 13A-flocs 2 glazing, clroutr, 2 glazing, cir outr, 0.143 0.650 0.650 n n n 4.00 18.20 18:20 2.65 23.80 23.80 16 0 0 16 0 0 64 0 0 41 0 0 0 0 0 -0 0 0 '0 0 0 0 0 0 W 11 2 glazing, cir outr, , _ 13A-4ocs 0.650 0.143 n a 18.20 4.00 23 80 2.55 . '0 0 0 0 0 0 0 0 0 % 0 0 , _ 0 0 0 0 y " 126-0sw 11 D0_ 13A-4ocs A.097 0.390 0.143 s s _ s 2.72 10.92 4.00 '2.58 , 11.31. 2.55 j 0 _ _ , z 0, 0 0 0 0 0 0 0 0 0 0 32 _ _ ` 21 0 11 21 0 30 . 229 0 28 238 0 1� I-G 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 s s 18.20 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11DO _ 1213-0sw _ 13A-4ocs 0.390 0:097: 0.143 s w, w 10.92 2.72 4.00 11.31 2.58 2.55 0 0 80 0 0 65 0 0 260 0 0 165 0 0 0 0_ 0 0 0 „. 0 0 0 0 0 w 2 glazing, cir low-e 2 glazing, cir outr, 0.650 0.650 w w 18.20 18.20 33.77 74.13 15 0 0 0 273 0 507 0 0 0 0 0 0 0 0 0 ��--------GG C 16X19-Md 0.408 ' -, 1.59 _ 1.25 116 110 138 61 61 _ _ 97 16 F. 19A-00cvtp _ 0.034 - 0.80 0.43 110 110 ,174 88 _ 47 . 61 ., 61 49 26 6 c)AED excursion 189 -4 Envelope loss/gain 860 1086 405 364 12 a) Infiltration 178 50 59 17 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Qines 6 to 13) 1038 1137 464 381 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1038 1137 464 381 15 Duct loads 27% 50% 278 563 27% 50% 126 Total room load Air required (cfm) 1316 641 1700 84 2 i 28 fR..C.Ii Right -Suite® Universal 2017 17.0.03 RSU08101 ...serslQuick CaIcslDocumentslMcGHEE RESIDENCE. rup Calc = MJ8 Front Door faces: 2016-Jun-20 17:14:07 Page 3 -r�- �vrightsoft• Right-J � Jorksheet Job: Entire House Date: Feb 24, 2o1s By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC MASTER BATH 2 3 Exposed wall Room height 6.3 ft 8.0 ft heat/cod 25.3 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 30.0 ft 30.0 ft2 1.0 x 78.0 ft 78.0 ft2 Ty Construction number U-value (Btuh/ftk°F) Or HTM (Btuhlft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Stuh) Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 13A-4ocs 2 glazing, cir outr, 2 glazing, dr outr, 0,143 0.650 0.650 n n n 4.00 18.20 18.20 2.55 23.80 23.80 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, cir outr, 13A-flocs _ 12B-Osw 11D0 13A4ocs 2 glazing, cir low-e 2 glazing, clr low-e 0.650 0.143 0.097 0,390 0.143 0.650 0.650 n... a s s: s s s _ , 1.8.20 4.00 2.72 10.92 4.00 18.20 18.20 23.80 2.55 2.58 _ 11.31 2.55 14.99 14.99 , 0 0 0 , _ _ ; 0 0 0 0 _ 0 0 0 0 0 0 0 .0 0 0 0 0 0 0 _ 0 0 0 , . , 0 0 0 0 0 _ 96 56 0 0 8 0 0 , 96 56 0. -8 8. 0 . 0 384 162 0 -32 146 0 0 244 144 0 -20 120 0 W y�/ t-D. 1N VI! .11DO , 1213Osw:. 13A-4ocs 0.390 0.097 0,143 s , w . w 10.92 .2.72 4.00 11.31 , 2.58. 2.55 0 ! _0', 51 0., 0 51 „0 0 203 _ 0 0 129 0 0 51 0 0 51 0 ..., 0. 203 0 0 129 2 glazing, dr low-e 2 glazing, cir outr, 16X194hd 0.650 0.650 6.409 w w - 18.20 18.20 1.59 33.77 74.13 1.25 0 0 30, 0 0 30 0 0 ' 48 0 0 38 0 0 78 0 0 . 78 0 0 124 0 0 98 C F 19A-36cvtp 0.034_ - 0.80 0.43 30 36 24 13. 78 78 62 33 6 c) AED excursion -2 -9 Envelope loss/gain 274 1771 1039 739 12 a) Infiltration 94 26 376 106 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 368 203 1415 845 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 368 203 1415 $45 15 Duct loads 27% 50% 99 101 27% 50% 0 9 Total room load 467 304 7 63 Air required (cfm) 23 15 8 A& wroghtsoft• Right -Suite® Universal 2017 17.0.03 RSU08101 ...sers%Quick Caics\DocumentslMcGHEE RESIDENCE. rup Calc = MJ8 Front Door faces: 2016-Jun-20 17:14:07 Page 4