Loading...
HomeMy WebLinkAboutWIDE TIE-DOWN PLACEMENTREVISIONS BY A,(�REVISED PER BLDG. DEPT. BGM 01-05-14 '1� UNIT TO 5E TIED DOWN 2X PT W// �71 ///�A/ TIE DOWN STRAP — _ PER SPECIFICATIONS 8"XSit. X16" LL CBS BLOCK Z _ PIERS WIU O O O PROVIDE 18"x18"x4" J J PRE -CAST CONCRETE PAD UNDER EACH PIER ANCHOR (SEE DETAIL) An SECTION A -A SCALE: 3/4" = I'-0" ,_m„ --------------------------� ---------------- 6'-011 8u 4i_0n V. 4'_0n 8" 4'_0n 8" (o'_0n / I I I �I II I II I .. I �� II I II CONCRETE (I) Ya" X 2Y4" Lis. TAPCON PER BLOCK 4 (2) AT CONCRETE: 180 LBS. PROVIDE 18"x18"x4" PRE -CAST CONCRETE O O O I O 00 PAD UNDER EACH PIER I I i A C� MOBILE HOME 1 O O O O O 6'-0" I 6a"I 6 W-0" Ig"I L L 4'_0' �S�� 4i_�i Ig"I 4'_0" 8nI r -01, IBnI ------------------ -*--�}'-- -------------- TIE - SCALE: 1/4" = 1'-0., QUIREMEN7S NOTE: THE FOUNDATION/PIER SYSTEM IS DESIGNED TO RESIST FLOOD ELEMENTS OF FLOTATION, COLLAPSE AND LATERAL MOVEMENT PER FEMA CRITERIA FOR EXPOSURE "D" LOCATIONS. 80 " I II s"xs"xl6" J/ CBS BLOCK PIERS '-d" 4'-0" 4'-0" 4'-0" 5'-4" 5'-4" 5'-4" ----- ------ ----t----- --- ----- --- ------ ----- ------ ----- El 1 --------------- -------------------------------- El cl El fi-r-r-- y-,-rt------- 1 r-- ----------- L--------------------------------------------------------------------T- - ------------------------------------------------ it r11ill, '1"I II 2'-flJ i" I -BEAM I I PROVIDE )4" MACHINE LT PROVIDE �" MACHINE BOLT li Ili THRU 1-5EAM W/ (U TIE OWN THRJ I -BEAM W/ (2) TIE DOWN li lu i It STRAP AT BOLT W/ (1) iG82 STRAPS AT BOLT W/ (2) I I 1 I i it INTO GROUND MOBILE HOME ANCHOR INTO GROUNDII II (SEE SECTION A -A) (SEE SECTION A -A) I I I l I _____________________________________________________________________________________________________________________________—_____}_ I I d� ANCHOR ANCHOR d b ❑ ❑ ❑ ❑ ❑ ❑Y ❑ ❑ ❑ ❑ ❑ 8" W-4" 5'-4" 5'_4" 5'-4" 4'-0" 4'-0" 4'-0" UNIT WT. 360 LBS- 35.3 ��FT r CONDENSING UNIT SIMPSON MSTC52 SXICo BLOCK 4 COURSE (2) 014 SHEET METAL SCREWS TO CONDENSING UNIT- 200 LB. SHEER WORKING CAPACITY A/C TIE -DOWN DETAIL WIND AGAINST FACE Q UNIT: 28-625 x 46 = 102 SQ- FT. x 45 P.5F- = 45S LB. UPLIFT 144 459 - 360 LB. UNIT = 99 LBS. UPLIFT ASSUMING EQUAL LOAD DISTR. TAPCON WILL HOLD 180 LBS. AND 2 SCREWS WILL HOLD 200 LBS. AT EACH OF THE 4 CORNERS - THEREFORE STRAP, TAPCON AND SCREWS WILL HOLD UNIT IN PLACE. A 4" SLAB, 42" X 52" WEIGHS 195 LBS. A -BOLT Iu UCO8T LE BUILDING DIVISI ON REVIEWED�UL sWI$I -' OW FLACEt*1ENT FOR C NCE REVIEWED BY SCALE: 1/4" 1'-0" s DATE •A PLAN�EPTONJOBOR MUST BE NO INSPECTION WILL BE MADE 5 B-50 "P-II X 2-%" NOTES 2-GALV. BOLTS W-II X 2-%" La W/ HEX. SQ. NECK W/ NUTS TENSION BOLT LABELED (A) FOR FRAME ATTACHMENT ONLY. TENSION BOLT LABELED (B) FOR VERTICAL TENSION. PnIP TY== 1501E Ur.�1111Y1a1�� 4% PAR"- 5WSI l )D, 1'-6" HELIX /C3 � 4-$/4 PART h 5S094 >D, I'-6" HELIX 'E 2 SOIL USE: Dl PART a 59099 Go W W x d� O A � 0­4 19=4 W z o o w E w �W'^^ p� 06 Cc rn 60" X W/ ROD, P-1" HELIX ANCHOR DETA« �c��o�r.._ m h Q'y � O CYJ NTS. JAN ' 9 W) O O AA W A OWNS CERTIFIED O 5 E D 16�PH. TIW EXPOSURE G MOBILE WN W Z W 4 DECKS ARE ENGINEESED FOR USE IN A "FLOOD ZONE" ;�", <C I""I O O MOBILE HOME ANCHORING ORDINANCE x 1°'J A wRECOMMENDED FOR PURPOSES OF EVALUATION 4 PERFORMANCE, EACH GROUND ANCHOR WHEN FORCE SHALL BE W co z W INSTALLED 4 LOADED IN THE DIRECTION OF THE EXPECTED WHICH IS SPECIFIED. 04 �1 U NOT LESS THAN 4,150 POUNDS IN THE SOIL TYPE FOR ALL MOBILE HOMES SHALL BE ANCHORED t0 VIOED ANCHOR ON THE HOME AND SHOULD BE N COMPLIANCE WITH EXISTI H.Up- %L£ HOME CONSTRUCTION A M I AF;VS. NEW HOMES SHATHE AN REDE THE SPEGIFIGATIONS OTHE O UO HOME.TO ASDPROVI PROVIDED B�YSAFETY MANUFACTURER Or M O NOTE; GROUND ANCHORS FOR FLORIDA ONLY: FOR PURPOSES OF INSTALLATION OF MANUFACTUIRED/1105ILE HOMES IN THE STATE OF FLORIDA, THERE WILL BE TWO SOIL G6 �j Z ALL ANCHORS AND STABILIZER PLATES MUST BE GALVANIZED- CLASSIFICATIONS. h+l Go SOIL CLASSIFICATION ANALYSIS: COLOR CODE PROBE VALUES Z 't� uz TYPES OF SOIL (IN LBS.) O PQ "4A" - LOOSE TO MEDIIF9 DENSE SANDS, FIRM TO GREEN 2'15-350 ryrE I STIFF CLAYS AND SILTS, ALLUVIAL FILL. 35_' - VERY LOOSE SANDS, FIRM CLAYS AND RED 115-215 Date: 01-0244 TYPE 2 SILTS. ALLUVIAL FILL. THE TEST PROBE IS THE DEVICE USED TO MEASURE TORQUE VALUES OF SOILS TO Scale: 1/4" = I'-0" ASSIST N THE DETERMINING P.S.I. HOLDING CAPABILITY OF THE SOIL N WHICH THE ANCHOR IS INSTALLED. THE PROBE HAS A HELICAL SECTION 10.15" LG. X 125" MAJOR DNA. X 0.01 MINOR DIA. X I-1S" PITCH. THE CONNECTING SHAFT MUST 15E OF Drawn: MM/BCsM SUITABLE LENGTH FOR OVERALL ANCHOR PENETRATIOK Job: OSBORN THIS SETUP HAS BEEN DESIGNED FORA FLOOD ZONE INSTALLATION Sheet: DESIGN CODE F$C 2010 � Of Sheets