Loading...
HomeMy WebLinkAboutREVIEW-COMMENTSL� Planning &,Development Servieisv Building 8i Code Regulation Division. 2300 Virginia'Avenue FortPierce FL. 34982„ Phone;(772)462=2172 Fax:(772)462-6443 SCANNLU REVIEW COMMENTS 31, PnQ Sande ' PROPERTY INFORMATION Address: 581 Nettles Blvd City / State / Zip: Jensen Beach, FI 34957 Parcel M 4502-501-0767-000/5 Zoning: HIRD APPLICATION INFORMATION Permit Number: 1510-0286 Owner(s): Richard F Murray Jurisdiction: SAINT LUCIE COUNTY Lot#: Stories: Permit Type: BUILDING RESIDENTIAL (SFRIUP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Murray Richard F Business Name: Shoreline Rv & Mobile Home Repair Inc Business Addr: 1290 Ne Business Park PI City / State / Zip: Jensen Beach, FI 34957 REVIEWS AND COMMENTS Review Tvae DOCUMENTS MISSING 10/19/2015 Comment: 10/19/2015 Comment: 10/19/2015 Comment: 10/20/2015 Comment: FRONT COUNTER REVIEW Comment: PLANS EXAMINER REVIEW Block: Automatic Sprinkler System? No Fax Number: 772-334-4335 Email: Rfm9815@Aol.Com Status Reviewed By Date Started Date Completed Date Released PENDING Deanna Givens 10/19/2015 NOTICE OF COMMENCEMENT TRUSS DRAWINGS THE CONTRACTOR/AG ENT IS REQUIRED TO SIGN THE FLOOD HAZARD MEMO AT TIME OF PICK UP. APPROVAL FROM NETTLES HOA. COMPLETE Deanna Givens 10/19/2015 10/19/2015 10/19/2015 PENDING William Durden 11/17/2015 11/19/2015 Comment: • PLEASE ADD TO THE PLANS THE CLIMATIC AND GEOGRAPHIC DESIGN CRIERIA WEATHERING AND TERMITE AREA IN ACCORDANCE WITH TABLE 301.2.(1) Comment: • PLEASE SHOW WHAT TYPE OF FLOOD VENTS ARE BEING USED AND DOCUMENTATION ON THE AMOUNT 11/19/2015 OF UNOBSTRUCTED AREA EACH HYDRO VENT HAS AS TO MEET THE REQUIRMENTSOF 322.2.2 OF THE 2014 FLORIDA RESIDENTIAL CODE Comment: • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND 11/19/2015 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE i Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2010 FLORIDA BUILDING 11/19/2015 CODE REVIEWED AND APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61 G15- 30.005 OF THE FLORIDA ADMINISTRATIVE CODE. 11/19/2015 Comment: • SUBMIT SOIL REPORT, SEE NOTES ON PLAN. 11/19/2015 Comment: • SEE COVER PAGE LOAD SCHEDULE. REMOVE REFRANCE TO 2010 FLORIDA BUILDING CODE. i cowl _ Planning &,Development Services Building. & Code Regulation Division, 2300'Virginia Avenue Fort Pierce; F.L. 34982 Phone:(772)462-2172 fax:(772)462-6443 REVIEW COMMENTS `% 11/19/2015 Comment: • SHOW DETAIL OF OVERHANG ON ZERO LOT LINE SIDE MEETING 1HR RATING, SEE R302.1(1) DETAIL. SEE R703.8 OF THE 2014 RESIDENTAL BUILDING CODE 11/19/2015 Comment: • PLEASE SUBMIT WINDOW FLASHING • PLEASE SHOW THE EXTERIOR WALL ON THE SIDE WITH THE ZERO LOT LINE HAVING A ONE HOUR 11/19/2015 Comment: RATED WALL FROM BOTH SIDES IN ACCORDANCE WITH TABLE 302.1 OF THE 2014 FLORIDA RESIDENTIAL CODE 11/19/2015 Comment: • ENERGY CALC CALLS OUT R-30 INSULATION IN THE CEILING, PLANS CALL OUT R-19 PLEASE CORRECT. Comment: • LINE 14 OF THE ENERGY CALCS CALLS OUT FOR A PROPANE TANKLESS WATER HEATER PLEASE 11/19/2015 CLARIFY. ELECTRICALS DIAGRAM CALL OUT FOR ELECTRIC TANKLESS SYSTEM. LINE 14 OF THE ENERGY CALCS CALLS OUT FOR A PROPANE TANKLESS WATER HEATER WITH AN EF OF 11/19/2015 Comment: • 0.590 PLEASE SEE R403.4.4.2 AND C404.2 OF THE FLORIDA ENERGY CONSERVATION CODE.. 11/19/2015 Comment: • PLEASE SUBMIT PRODUCT INFORMATION SHEETS FOR THE WATER HEATER. Comment: • PAGE 3 OF 4 OF THE ENERGY CALCS, WINDOWS OVERHANG DEPTH AND SEPERATION IS INCORRCT. 11/19/2015 SEE R405.5.3.2 OF THE 2014 FLORIDA ENERGY CODE. • LINE 7 AREA WEIGHTED AVERAGE OVERHANG DEPTH OF THE ENERGY CALCS CALLS OUT FOR A 6 11/19/2015 Comment: FOOT AVERAGE OVERHANG PLEASE CLARIFY. Comment: • OPENINGS IN WALL ARE NOT ALLOWED ON ZERO LOT LINE SIDE. SEE TABLE 302.1(1) OF THE 2014 11/19/2015 RESIDENTAL BUILDING CODE. I Comment: • PLEASE SUBMIT THE ENERGY PERFOMANCE SHEETS OR SUBMIT A THE NFRC FENSTRATION 11/19/2015 MANUFACTURE CERTIFICATE FOR THE U-FACTOR AND THE SHGC SHOWING COMPLIANCE WITH CHAPTER 4 SECTION 402.1.1 OF THE 2014 ENERGY CODE FIFTH EDITION Comment: • PLEASE NOTE THAT I!THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE 11/19/2015 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. ZONING REVIEW COMPLETE Lydia Galbraith 10/1912015 10/1912015 10/19/2015 Comment: r s �. 4 Planning & Development Services t ! Building 4 Code Regulation Division 2300 Virginia,Avenue Fort Pierce, FL. 34982 Phone:(772)462 2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 581 Nettles Blvd City / State / Zip: Jensen Beach, FI 34957 Parcel 4502-501-0767-000/5 Zoning: HIRD (� r REVIEW COMMENTS Owner(s): Richard F Murray Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: APPLICATION INFORMATION Permit Number: 1510-0286 Stories: i Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Murray Richard F Business Name: Shoreline Rv & Mobile Home,Repair Inc Business Addr: 1290 Ne Business Park PI City I State I Zip: Jensen Beach, FI 34957 REVIEWS AND COMMENTS Page 1 Automatic Sprinkler System? No Fax Number: 772-334-4335 Email: Rfm9815@Aol.Com Review Type Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING 'Deanna Givens 10/19/2015 10/19/2015 Comment: TRUSS DRAWINGS 10/19/2015 Comment: THE CONTRACTOR/AGENT IS REQUIRED TO SIGN THE FLOOD HAZARD MEMO AT TIME OF PICK UP. FRONT COUNTER REVIEW COMPLETE Deanna Givens 10/19/2015 10/19/2015 10/19/2015 Comment: I PE REVIEW COMMENTS (2) INCOMPLETE William Durden 1/6/2016 11/19/2015 Comment: • SUBMIT SOIL REPORT, SEE NOTES ON PLAN. PLANS EXAMINER REVIEW COMPLETE ! William Durden 11/17/2015 1/6/2016 1/6/2016 Comment: ZONING REVIEW COMPLETE Lydia Galbraith I 10/19/2016 10/19/2015 10/19/2015 Comment: