Loading...
HomeMy WebLinkAboutBOAT LIFTHURRICANE BOAT CATEGORY-5 VERTICAL LIFTS ENGINE. 'A OUT -TO -OUT I1rN L01 Stainless Steel Piling Mount Bracket VAth 2-3/8' Bolts Connecting The Bfcaket To The Assembly. 2-3/8"ier Stainless Steel Log Bolts Into The Side Of Piling pu I xmt. a >� t'� CT DRIVE "1 V 9DIRECT DRIVE OPTION 1ANCE BOCC PILM 8PACM Ult NDED CAPACITY A B IZES 500 LB 15W 132' 6' DIA 7,000 D 150' 144' s- DIA Pflhg PeneVatian 10,000 LB 15W 150' 0' INA 112r' To Be 10' into The 13.000 Le 150' 150' 0' qA Send Batten Or 5' 16,000 LB 150' 188' 0' D1A Into The Rork Strata 20,000 LB 168' 168' To2' DIA Recpnmmd 2{,000 L8 18Y Mir 2' DI a Pom A our-m-OUT B CENTLTt-TD-CDM Lilt Top Beam 2 Cradles per lift Bunk C 1,la Guide guide D.D. U.H.S. Cop. Ch�manel I-98eam Boats Size Post Bmrin a 8 Winder 51ie Geer Wtor Oaor 2. (STD) Haight H.P. Motor 4'0 2 Eo. 6'H v 4'W %iJ7/•O ({) 1 2W Y .23 15W Lg. 4.03 WL/Lk, FL 5/Ill' SS7. S 3/4EH.P. 120/20A M.P. 2b/IOA 54 Y 15 v ZW (2 Ea) (2 Ea) 7,000I 2.25 W Y .26 % 1N/O 4.70 WLm FL 1 Part (5 Ea) 1 H.P. 120/20A 1 1/2 H.P. 150' L 2'v8'xt{4' Wool 2' Shcd 375' DIA SOLID 2 OA 240/10A f0.000/ ° W 17 liH % 5'W Y (2 Ea.) 22..5 5010 6.18 WL/Un FL Carpeted ALUMINUM VINDER 3 4HP. 120/2. 1 H.P. Ib29 ({) 5/18' BO81-T6 ALUM. 24o loA 240/10A 13,000i 74 x 17 2.75 W 8'H x 5'W x •4111 (2 Ea.) 150" x /50 O 7.02 Wt./Un FL SST. (2 Ea) 1 210/ OA a. % 6•W 16.0001 is w O y0'H Il(.7S %IPT 144' 2 Part 1 HP. ' Y 166 0 8.84 WL/LN FL Wood 1 1/2 H.P. 150.300 2b/f0A 2b/IOA 20,000/ J 75 .25 10'H x 6'W % .41(.25 3'Y10'vlea' PT (4) (6 Ea) (2 Ea.) % .41 % 168 O 8.8{ WLAM FL Wood Carpeted S/I6' 10' 2' Sdkl 1 1/2 H.P. 168' L T. 6061-TB SOLID ALUMINUM 240/10A 8H % U. 10'H x 6'W Y ..� .� / J'%10'x182' (2 Ea.) 24,000g J.75 W Y .41 182 O PT IVpel ALUM. WINDER 1 1/2 H.P. 18Y L 1Q2BYWL/Un FL Carpetm 3 Part 240/IOA THE WORK SPECIFIED HEREIN HAS BEEN DESIGNED & ALL WORK SHALL BE IN ACCORDANCE WITH STRUCTURAL PROVISIONS OF THE 7th EDITION 2020 FLORIDA BUILDING CODE. NOTE: THIS LIFTING STRUCTURE HAS BEEN DESIGNED TO WITHSTAND WIND LOADS ASSOCIATED WITH WIND SPEEDS OF V,A4= 180 MPH, VAss = 139 MPH (3 SEC. GUST) EXPOSURE 'D' WITHOUT A BOAT 0 THE LIFT PER RE ' 7-10 USING ABOVE GROUND SIGN/WALL METHOD, THE LIFTING STRUCTURE INCLUDING BOAT HAS BEEN DESIGNED TO WITHSTAND WIND SPEEDS OF VLII=90 MPH IN EXPOSURE 'C' OR 80 MPH IN EXPOSURE V. OWNER RESPONSIBLE TO REMOVE BOAT FROM LIFT DURING WINDSTORM EVENT IN EXCESS Vosd AS CALATED BELOW, PER FBC 3105.5.3 STRUCTURES DESIGNED TO BE READILY REMOVED OR REPOSITIONED DURNING PERIODS OF HIGH WIND VELOCITY SHALL BE POSTED WITH A LEGIBLE AND READILY VISIBLE DECAL OR PAINTED INSTRUCTIONS TO BE THE OWNER OR TENANT TO REMOVE OR REPOSITION THE STRUCTURE OR PART THEREOF DURNING SUCH PERIODS OF TIME AS ARE DESIGNATED BY THE U.S. WEATHER BUREAU AS BEING A HURRICANE WARNING OR ALERT. THE LIFT OWNER SHALL BE NOTIFIED OF THESE CONDITIONS BY THE PERMIT HOLDER. NO WARRANTY, EXPRESSED OR IMPLIED, IS CONTAINED HEREIN. Vosd MAY BE CALCULATED BY THE FOLLOWING FORMULA: Vasd a v•O.6 • Vuit. DESIGN OF BOAT WIND LOADING HAS BEEN PERFORMED WITH THE FOLLOWING RATIOS AS CONFIRMED BY OTHERS: B/e=3, s/h - 0.75. FOR A Of of 1.6 MAXIMUM WHERE H IS THE HEIGHT TO TOP OF BOAT, B IS HORIZONTAL DIMENSION, AND S IS VERTICAL DIMENSION - CERTIFICATION OF BOAT LIFT TO EXISTING STRUCTURE AND ALL ELECTRICAL OR MECHANICAL CERTIFICATIONS ARE BY OTHERS; ENGINEER SEAL CERTIFIES ASSEMBLY OF LIFT ONLY. THIS DETAIL IS PREPARED AS A GENERAL NON -SITE SPECIFIC MASTER PLAN SHEET DETAIL. TYPICAL FIELD CONDITIONS ARE ASSUMED IN THE DESIGN. WOOD PILES SHALL BE SEASONED WOOD WITH G=0.55 OR BETTER. SHOULD ANY SPECIFIC LOCATION DIFFER FROM THAT SPECIFIED HEREIN, OR STANDARD FIELD CONDITIONS, ADDITIONAL SPECIFIC ENGINEERING MAY BE REQUIRED AS DETERMINED BY THE BUILDING INSPECTOR AND PERMITTING CONTRACTOR. CARE SHALL BE TAKEN BY CONTRACTOR IN ALL APPLICATIONS OF THIS DETAIL. AS THIS IS NOT A SITE SPECIFIC DRAWING, IT IS THE RESPONSIBILITY OF OTHERS TO ENSURE THE INTEGRITY OF INSTALLA11ON TO THE HOST STRUCTURE. ALUMINUM MATERIAL: 6061 T6 ALUMINUM ALL WELDS ARE MIN. 1 4- FULL FILLET WELD USING 5556 FILLER ALLOY. ALL WELDING MUST CONFORM TO AISC STEEL CONSTRUCTION MANUAL 13TH ED AS INSPECTED AND VERIFIED BY OTHERS.THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALUMINUM MEMBERS FROM DISSIMILAR METALS TO PREVENT ELECTROLYSIS. FASTENERS I ALL ANCHORS TO BE HILT] BRAND OR MFR EQUIVALENT. ALL BOLTS SHALL BE HOT DIPPED GALVANIZED, OR STAINLESS STEEL & MEET THE REQUIREMENTS OF ASTM A304 WITH HARDENED WASHERS AND HEX NUTS. WASHERS SHALL BE USED BETWEEN WOOD & BOLT HEAD & BETWEEN WOOD & NUT. WHERE GENERIC FASTENERS ARE LABELED IN DETAILS, CAPACITIES SHALL BE EQUAL TO OR GREATER THAN HILTI KWIK BOLT II OR RED HEAD THRU BOLTS. EMBEDMENT DEPTHS SPECIFIED HEREIN ARE DEPTHS INTO SOLID SUBSTRATE AND 00 NOT INCLUDE THICKNESS OF STUCCO OR OTHER FINISHES. ALUMINUM MEMBERS IN CONTACT WITH CONCRETE AND WOOD SHALL BE PROTECTED BY "KOPPERS BITUMINOUS PAINT' OR POLYETHYLENE TAPE UHMW (ULTRA HIGH MOLECULAR WEIGHT) 11.7 mils (0.30 mm) MIN. TOTAL THICKNESS IN ACCORDANCE WITH CURRENT FLORIDA BUILDING CODE. ALL WELDS PER FLORIDA BUILDING CODE. SPECIALTY ENGINEERING SERVICES & SOLUTIONS INC. HAS NOT VISITED THIS JOBSITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR SUPPLIED DATA AND MEASURER SPECIALTY ENGINEERING SERVICES & SOLUTIONS INC. SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. WORK SHALL BE VERIFIED PRIOR TO CONSTRUCTION. SPECIALTY ENGINEER SERVICES & SOLUTIONS. SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. ENGINEERING SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR at. GI. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COSTS & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FAB\ICA_TIQRII�P OON HEREIN, NO CONSTRUCTION E PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FORM DEVIATIONS OF THIS PLAN, EXCEPTIIPPRR :� �1 CERTIFICATION OR AFFIRMATIONS AREANTENDED. THIS SPECIFICATION SHEET GOOD ONLY AT THIS NAME AND ADDRESS voib WITR66T.!IRRIGNE%SEAL OVER N NAMD ADDRESS, r o9. ,Y, �Z�°i?�i'_.2-XO'�r1 ��L a far ermudez, PE. • �A� r.. tl FI rido No. 551 1 q • /-7 7 / CITY 1 P.TL'""1 ,�. — 2IP� e �0 5 � 4 • HURRICANE BOAT LIFTS 3301 S.E. Stater Street B&B Engineering a a 2237 Woods Edge Clale o '( OF e Stuart, Flor lda 34997 Orlando, FL 32817� ���� ' m (772)-781-2556 Fax (772)-781-4854