Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online Page 1 of 2 u a a►I►r•w -� Business , Professional Regulation DIV . z,.. .. Florida Departments BCIS Home I Log In I user Registration I Hot Topics . Submit S r e Ilcatlons I FBC Staff I BCIS Site Map I Links I Search Busines ProfessiI 11 Product Approval �IeYr✓ USER: Public User Regulation Product Approval Menu > Product or Application Search > Application Us t > Application Detail • FL # FL1654-R15 Application Type Revision Code Version 2014 Application Status Approved Comments Archived r Product Manufacturer POLYGLASS USA Address/Phone/Email 150 Lyon Drive Fernley, NV 89408 (570)384-1230 Ext242 jakins@polyglass.com Authorized Signature James Akins jakins@polyglass.com Technical Representative Steve Wadding Address/Phone/Email 150 Lyon Drive Fernley, NV 98408 (602) 363-7139 stevew@polyglass.com Quality Assurance Representative James Akins Address/Phone/Email 555 Oakridge Road Humboldt Industrial Pkwy Hazleton, PA 18201 (800)894-4563 jakins@polyglass.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 71 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert Nleminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 06/27/2016 Validated By John W. Knezevich, PE r✓ Validation Checklist - Hardcopy Received Certificate of Independence FL1654 R15 COI 2015 01 COI Nieminen.odf Referenced Standard and Year (of Standard) Standard Year ASTM D6163 2000 ASTM D6164 200� fig http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFg... 7/8/2015 . Florida Building Code Online Page 2 of 2 ASTM D6222 2008 ASTM D6509 2009 FM 4470 1992 FM 4474 2004 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/27/2015 Date Validated 03/01/2015 Date Pending FBC Approval 03/04/2015 Date Approved 04/15/2015 Date Revised 06/17/2015 lmmary of Prnrlllrt•e FL # Model, Number or 11 Description Name 1654.1 Polyglass SBS and APP d APP modifled bitumen roof systems Modified Bitumen Roof Ir Systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL1654 R15 II 2015 02 FINAL Al ER POLYGLASS MODBIT FL1654- R15.Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this Evaluation Reports application relates to one particular FL1654 R15 AE 2015 02 FINAL ER POLYGLASS MODBIT FL1654- R15.Ddf assembly over concrete deck. Refer to the ER Appendix for other systems and deck Created by Independent Third Party: Yes types. 2.) Refer to ER, Section 5 for other Limits of Use. Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. .Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: a® eChcsl tiCCUt7t AI I:TNICS' http://www. floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFg... 7/8/2015 ��TRRINI*ERD I 'APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT, RESISTANCE II Table Deck Application Type Description Page 1A-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4 1A-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5 1B Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 5 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6 1D Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 6 1E-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 7-8 jE-2 Wood eurReroof=(Tear-O orecover - E—__—____Non-Insulated; Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover T 8-9 1F Wood ew or Reroof-(Tear-Off) F No`n-Insu ated, Bonded Roof Cover 9 2A Steel or Conc. New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 10 2B Steel or Conc. New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 11 2C Steel or Conc. New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 12-13 3A-1 Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 14-17 3A-2 Concrete New or Reroof (Tear -Off) A-1 Bonded Temporary Roof, Bonded Insulation, Bonded Roof Cover 18-19 3B Concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 19 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 20-21 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 22 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 23-25 SA CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 26 SB CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 27 5C CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 28 5D CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 28 5E CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 28 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 29 6B Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded insulation, Bonded Roof Cover 30 6C Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 30 6D Gypsum New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 30 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 31-33 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 33 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, Dens Deck, Dens Deck Prime, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board that meets the CIA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover. Exterior Research and Design, I.I.C. d/b/a Trinity] ERD Evaluation Report P9290.02.08-1113 for FL1654-R15 Certificate of Authorization #9503 �— Revision 13: 02/26/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 1 of 33 ��TRINITYIERD 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. S. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturers published instructions. ➢ HA (HA): Full coverage at 25-30 Ibs/square. ➢ Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ 3M CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocya n u rate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) ➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) ➢ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+GL) ➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3) ➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II) ➢ 3M CR-20: MDP -117.5 psf (Min. 1.0-inch thick) 7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. f8 For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC !J Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 9` For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover installation, the existing roof system shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124. 12. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. 13. LWIC shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. For systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. Exterior Research and Design, I.I.C. d/b/a Trinity1 ERD Evaluation Report P9290.02.08-1113 for FL1654-R15 Certificate of Authorization #9503 Revision 13: 02/26/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 33 r 14. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. TABLE 1: POLYGLASs ROOFCOVERS It Reference Layer Material Application BP -AA Base Polyglass G2 Base, FBC Approved ASTM D4601, Type II HA 20-40 Ibs/square (Base and Ply sheets, Asphalt -Applied) Ply Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI at SBS-AA Base or Ply Elastobase, Elastobase Poly, Elastoflex V, Elastoflex S6 HA at 20-40 Ibs/square (SBS, Asphalt -Applied) Cap Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko G SBS, Polyfresko G SBS FR SBS-TA Base or Ply Elastoflex V, Elastoflex S6 (SBS, Torch -Applied) Cap Elastoflex V, Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko G SBS, Torch -Applied Polyfresko G SBS FR SBS-SA Base Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR Self -Adhering (SBS, Self -Adhering) Cap Elastoflex SA P, Elastoflex SA P FR, Polyreflect APP-TA Base or Ply Polyglass APP Base, Polyflex, Polybond Torch -Applied (APP, Torch -Applied) Cap Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR APP-SA Cap Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool Self -Adhering g (APP, Self -Adhering) 15. Any of the following FBC Approved coatings maybe applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non Fibered Roof Coating or Mule -Hide 111 Non-Fibrated Roof Coating; ➢ PG300 Fibered Roof Coating or Mule -Hide 102 Fibrated Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating or Mule -Hide 416 Standard Non-Fibrated Aluminum Roof Coating; ➢ PG650 Fibered Aluminum Roof Coating or Mule -Hide 406 Standard Fibrated Aluminum Roof Coating; ➢ PG700 High Quality Elastomeric Roof Coating; ➢ PG800 Asphalt Emulsion Roof Coating or Mule -Hide 311 Emulsion Non-Fibrated; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating or Mule -Hide 410 Premium Non-Fibrated Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating or Mule -Hide 401 Premium Fibrated Aluminum Roof Coating; ➢ Polybrite 70 Premium Grade Elastomeric Roof Coating; ➢ Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating. 16. The following represent priming requirements for gypsum -based coverboards: ➢ Dens Deck and Dens Deck Prime shall be field -primed with PG300 prior to self -adhering or torch -applied membrane application. No priming is required for hot -asphalt membrane applications. ➢ SECUROCK Gypsum -Fiber Roof Board does not require field priming for any membrane application. 17. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report P9290.02.08-1113 for FL1654-1115 Certificate of Authorization #9503 Revision 13: 02/26/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 3 of 33 M ',,I TRINITY ERD TABLE 1A-1: WOOD DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover MDP No. (See Note 1) Type Fasten Attach Type Attach Type - Attach Base Ply Cap (Psf) Min. 0.25-inch Dens Deck, Polyglass G2 Base, 32 ga., 1-5/8- 8-inch o.c. in 4-inch Dens Deck Prime, SECUROCK CertainTeed Glasbase, inch diameter tin lap and 8-inch o.c. (Optional) FBC Gypsum -Fiber Roof Board, BP -AA (Optional) SBS-AA, W-1 19/32- Firestone MB Base,JM , caps with 11 ga. in three, equally Approved, HA Min. 0.75-inch Fesco Board HA or SBS- BP -AA or SBS-TA, -60.0 inch plywood Perma-Ply 28, Tamko annular ring spaced, staggered ASTM C1289 (homogeneous) or min. 0.5- AA SBS-AA APP-TA Glass Base or GAFGLAS shank nails center rows polyiso inch Structodek High Density #75 Fiberboard Roof Insulation Polyglass G2 Base, CertainTeed Glasbase, 32 ga., 1-5/8- 8-inch o.c. in 4-inch (Optional) FBC (Optional) SBS-SA, Min. 19/32- Firestone MB Base, JM inch diameter tin lap and 8-inch o.c. Approved, Min. 0.25-inch Dens Deck, One or gpp_SA , W-2 caps with 11 ga. in three, equally HA Dens Deck Prime, SECUROCK HA SBS-SA more SBS- SBS-TA, -60.0 inch plywood Perma-Ply 28, Tamko annular ring spaced, staggered ASTM C1289 Gypsum -Fiber Roof Board SA, SBS-TA, APP-TA Glass Base or GAFGLAS shank nails center rows polyiso APPTA #75 Polyglass G2 Base, CertainTeed Glasbase, 32 ga., 1-5/8- 8-inch o.c. in 4-inch (Optional) FBC (Optional) Min. 19/32- Firestone MB Base, JM inch diameter tin lap and 8-inch o. Approved , Min. 0.25-inch Dens Deck, Polyflex One orc. APP-TA -60.0 W-3 inch plywood Perma-Ply 28, Tamko caps with 11 ga. in three, equally ASTM C1289 HA Dens Deck Prime, SECUROCK HA SA Base more APP- Glass Base or GAFGLAS annular ring spaced, staggered polyiso Gypsum -Fiber Roof Board TA #75 shank nails center rows Min. 2-inch D-IS, OB500, 32 ga., 1-5/8- inch diameter tin 6-inch o.c. in 4-inch lap and 6-inch o.c. ACFoam II, III, CR-20 or M- Min. 0.25-inch Dens Deck, D-IS, BP -AA (Optional) SBS-AA, W-4 Min. 19/32- Elastobase or caps with 12 ga. in four, equally H-Shield, H- OSFA, atop Dens Deck Prime or OB500, or SBS- BP -AA or SBS-TA, -60.0* inch plywood Elastobase Poly annular ring spaced, staggered Shield CG, fastener SECUROCK Gypsum -Fiber CR-20 or AA SBS-AA APP-TA Multi -Max FA3 rows, 7-inch Roof Board M-OSFA shank nails center rows or ENRGY-3 O.C. 32 ga.,1-5/8- 6-inch o.c. in 4-inch Min. 2-inch D-IS, OB500, D-IS, (Optional) SBS-SA, Min. 19/32- Elastobase or inch diameter tin lap and 6-inch o.c. ACFoam II, III, H-Shield, H- CR-20 or M- OSFA, atop (Optional) Additional layers OB500, SBS-SA One or more SBS- APP-SA, 60.0* W-5 inch plywood Elastobase Poly caps with 12 ga. in four, equally Shield CG, fastener of base insulation CR-20 or SA, SBS-TA, SBS-TA, annular ring spaced, staggered Multi -Max FA3 rows, 7-inch M-OSFA APP-TA qpp-TA shank nails center rows or ENRGY-3 O.C. 32 ga., 1-5/8- 6-inch o.c. in 4-inch Min. 2-inch ACFoam II, III, D-IS, OB500, CR-20 or M- D-IS, (Optional) Min. 19/32- Elastobase or inch diameter tin lap and 6-inch o.c. H-Shield, H- OSFA, atop (Optional) Additional layers OB500, Polyflex One or APP TA -60.0* W-6 inch plywood Elastobase Poly caps with 12 ga. in four, equally Shield CG, fastener of base insulation CR-20 or SA Base more APP- annular ring spaced, staggered Multi -Max FA3 rows, 7-inch M-OSFA TA shank nails center rows or ENRGY-3 O.C. Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Evaluation Report P9290.02.08-1113 for FL1654-1135 Certificate of Authorization #9503 Revision 13: 02/26/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 4 of 33 TABLE 1A-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top insulation Roof Cover MDP (psf) No. (See Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap Min. 0.25-inch Dens Deck, Dens 12-inch o.c. in 4- Deck Prime, SECUROCK Gypsum - OMG Flat Bottom inch lap and 12- (Optional) FBC Fiber Roof Board, Min. 0.75-inch (Optional) SBS-AA, W-7 Min. 19/32- Elastobase or Plates (square) inch o.c. in two, Approved, ASTM HA Fesco Board (homogeneous) or HA BP -AA or BP -AA or SBS-TA, -60.0 inch plywood Elastobase Poly with Roofgrip #12 equally spaced, C1289, type 11 min. 0.5-inch Structodek High SBS AA SBS-AA APP-TA staggered center polyiso-cyanurate Density Fiberboard Roof rows Insulation 12-inch o.c. in 4- (Optional) OMG Flat Bottom inch lap and 12- (Optional) FBC Min. 0.25-inch Dens Deck, Dens One or SBS-SA, W-8 Min. 19/32- Elastobase or Plates (square) inch o.c. in two, Approved, ASTM HA Deck Prime, SECUROCK Gypsum- HA SBS-SA more SBS- APP-SA, -60.0 inch plywood Elastobase Poly with Roofgrip #12 equally spaced, C1289, type 11 Fiber Roof Board SA, SBS-TA, SBS-TA, staggered center polyiso-cyanurate APP TA APP-TA rows 12-inch o.c. in fl- OMG Flat Bottom inch lap and 12- (Optional) FBC Min. 0.25-inch Dens Deck, Dens (Optional) W-9 Min. 19/32- Elastobase or Plates (square) inch o.c. in two, Approved, ASTM HA Deck Prime, SECUROCK Gypsum- HA Polyflex SA One or APP-TA -60.0 inch plywood Elastobase Poly with Roofgrip #12 equally spaced, C1289, type II Fiber Roof Board Base more APP- staggered center polyiso-cyanurate TA rows TABLE 1B: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System Deck (See Base Insulation Layer Top Insulation Layer Roof Cover MDP (psf) No. Note 1) Type Fasten Attach Type Attach Base Ply Cap Min.1.5-inch ENRGY Dekfast Hex with Dekfast Min. 0.75-inch Fesco Board (Optional if (Optional if using AA SBS-AA, W-10 Min. 19/32- 3, H-Shield or #12 orTruFast MP-3 with 1 per 1.33 ftz (homogeneous) or min. 0.5-inch HA using AA Ply) Base) One or more BP- SBS-TA, -60.0 inch plywood Polytherm TruFast DP Structodek High Density Fiberboard BP -AA, SBS- AA, SBS-AA, SBS-TA or APP-TA Roof Insulation AA APP-TA Exterior Research and Design, LLC, d/b/a Trinity I ERD Evaluation Report P9290.02.08-1113 for F1.1654-1115 Certificate of Authorization #9503 Revision 13: 02/26/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 5 of 33 \l I {�NI*ERD TABLE 1C: WOOD DECKS— NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Deck (See Top Insulation Layer Roof Cover No. Note 1) Base Insulation Layer MDP (psf) - Type Fasten Attach Base ply Cap (Optional) One or more Min. 0.5-inch Structodek High Density (Optional using (Optional if using AA Base) W-11 Min. 19/32- layers, any combination, Fiberboard Roof Insulation or min. 0.25- Dekfast Galvalume Steel Hex 1 per AA Ply) BP -AA, SBS- One more BP -AA, SBS- SBS-AA, SBS-TA, 82.5 inch plywood loose laid inch Dens Deck, Dens Deck Prime or with Dekfast #12 DP 1.33 ft2 AA AA, SBS-TA or APP-TA APP-TA SECUROCK Gypsum -Fiber Roof Board Min. 19/32- (Optional) One or more Min. 1.5-inch ENRGY 3, H-Shield or Dekfast Galvalume Steel Hex 1 per (Optional) One or more SBS-SA, APP-SA, W 12 inch plywood layers, any combination, Polytherm with Dekfast #12 DP or 1.33 ft2 SBS-SA SBS-SA, SBS TA, APP-TA SBS-TA, APP TA 82.5 loose laid TruFast MP-3 with TruFast DP Min. 19/32- (Optional) One or more Min. 1.5-inch ENRGY 3, H-Shield or Dekfast Galvalume Steel Hex 1 per (Optional) One or more W-13 inch plywood layers, any combination, Polytherm with Dekfast #12 DP or 1.33 ft' Polyflex SA Base APP TA APP-TA -82.5 loose laid TruFast MP-3 with TruFast DP TABLE 1D: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck (See Insulation Layer(s) Base Sheet Roof Cover No. Note 1) Type ype Attach Base Fasten Attach Ply Cap {psf) One or more Elastobase, Elastobase Poly, Polyglass OMG Flat Bottom Plates (square) 12-inch o.c, in 4-inch lap and 12- (Optional) One or SBS-AA,: W-14 Min. 19/32- layers, any Prelim. G2 Base, CertainTeed Glasbase, with Roofgrip #14, Dekfast Hex with inch o.c. in two, equally spaced, more BP -AA, SBS-AA, SBS-TA, -52.5 inch plywood combination Attached Firestone MB Base, JM Perma-Ply 28, Dekfast #14 or TruFast MP-3 with staggered center rows SBS-TA or APP-TA APP-TA Tamko Glass Base or GAFGLAS #75 TruFast HD Min. 19/32- One or more Prelim. Elastobase or Elastobase Poly with Dekfast Hex with Dekfast #14 or 12-inch o.c. in 4-inch lap and 12- SBS-SA,, APP-SA, W-15 inch plywood layers, any Attached poly top surface TruFast MP-3 with TruFast HD inch o.c. in two, equally spaced, One or more SBS-SA SBS-TA or -52.5* combination staggered center rows APP-TA Min. 19/32- One or more Prelim. Elastobase or Elastobase Poly with Dekfast Hex with Dekfast #14 or 12-inch o.c. in 4-inch lap and 12- W-16 inch plywood p layers, any Attached poly top surface TruFast MP-3 with TruFast HD inch o.c. in two, equally spaced, Polyflex SA Base APP-TA -52.5* combination staggered center rows Min. 19/32- One or more Prelim. OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap and 12- (Optional) One or SBS-AA, W 17 inch plywood layers, any Attached Elastobase or Elastobase Poly with Roofgrip #12 inch o.c. in two, equally spaced, more BP -AA, SBS-AA, SBS-TA, -60.0 combination staggered center rows, SBS-TA or APP-TA APP-TA Min. 19/32- One or more Prelim. Elastobase or Elastobase Poly with OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap and 12- SBS-SA, , APP-SA W-18 inch plywood layers, any Attached poly top surface with Roofgrip #12 inch o.c. in two, equally spaced, One or more SBS-SA SBS-TA or -60.0* combination staggered center rows APP-TA Min. 19/32- One or more Prelim. Elastobase or Elastobase Poly with OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap and 12- W 19 inch plywood P layers, any Attached poly top surface with Roofgrip #12 inch o.c. in two, equally spaced, Polyflex SA Base APP-TA -60.0* combination staggered center rows Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report P9290.02.08-1113 for FL1654-1115 Certificate of Authorization #9503 Revision 13: 02/26/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 6 of 33 VT---RR1N1TY I ERD TABLE 1E-1: WOOD DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System Deck (See Base Sheet Roof Cover MDP (psf) No. Note 1) Base Fasten Attach Ply Cap W 20 Min. 15/32- Elastobase Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in (Optional) BP -AA, SBS-AA, SBS-AA, SBS-TA 45 0' inch plywood two, equally spaced, staggered center rows SBS-TA or APP-TA or APP TA Min. 15/32- 9-inch o.c. at 2-inch lap and 12-inch o.c. in (Optional) BP -AA, SBS-AA, SBS-AA, SBS-TA W-21 inch plywood Elastobase Simplex MAXX Cap two, equally spaced, staggered center rows SBS-TA or APP-TA or APP-TA -52.5 W-22 Min. 15/32- Polyglass APP Base Original Simplex Cap Nails (1-inch metal head diameter, 11 gauge min. 1.25-inch long annular 6-inch o.c. at 3-inch lap and 6-inch o.c. in four, (Optional) SBS-SA or APP TA SBS-SA, APP-SA -52.5 inch plywood grooved shank) equally spaced, staggered center rows or APP-TA Min. Original Simplex Cap Nails (1-inch metal head o in four, o.c. at 3-inch lap and 6-ter W-23 inch plywood plywood Polyglass APP Base diameter, 11 gauge min. 1.25-inch long annular sc. r equally spaced, staggered center rows equally Polyflex SA Base APP-TA -52.5 grooved shank) Min. Original Simplex Cap Nails (1-inch metal head 6-inch o.c. at 3-inch lap and o in four, (Optional) SBS-SA, SBS-TA or SBS-SA, APP-SA, W 24 inch plywood plywood Elastobase (with poly top surface) diameter, 11 gauge min. 1.25-inch long annular enter r s equally spaced, staggered center rows APP-TA SBS TA or APP- -52.5 grooved shank) TA Min. 15/32- Original Simplex Cap Nails (1-inch metal head Original 6-inch o.c. at 3-inch lap and in four, oows W 25 inch plywood Elastobase (with poly top surface) diameter, 11 gauge x min. 1.25-inch long annular equally spaced, staggered center renter r s Polyflex SA Base APP-TA -52.5 grooved shank) Min. 15/32- Original Simplex Cap Nails (1-inch metal head 6-inch o.c. at 3-inch lap and 6-inch o.c. in four, (Optional) BP -AA, SBS-AA, SBS-AA, SBS-TA -52.5 W-26 inch plywood Elastobase (with sand top surface) diameter, 11 gauge x min. 1.25-inch long annular equally spaced, staggered center rows SBS-TA or APP-TA or APP-TA grooved shank) Elastobase, Elastobase Poly, Min. 19/32- Polyglass G2 Base, CertainTeed 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c. in 4-inch lap and 8-inch o.c. in (Optional) One or more BP- SBS-AA, SBS-TA, W 27 inch plywood Glasbase, Firestone MB Base, JM annular ring shank nails three, equally spaced, staggered center rows AA SBS-AASBS-TA or APP- , APP TA -60.0 Perma-Ply 28, Tamko Glass Base TA or GAFGLAS #75 Min. 19/32- Elastobase or Elastobase Poly with 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c. in 4-inch lap and 8-inch o.c. in (Optional) One or more SB5- SBS-SA, APP-SA, SBS-TA or APP- -60.0 W 28 inch plywood P Y of to surface poly P annular ring shank nails g three, equally spaced, staggered center rows q Y p gg SA, SBS-TA or APP-TA TA W 29 Min. 19/32- Elastobase or Elastobase Poly with 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c. in 4-inch lap and 8-inch o.c. in Polyflex SA Base APP-TA -60.0 inch plywood poly top surface annular ring shank nails three, equally spaced, staggered center rows Min. 15/32- 6-inch o.c. at 2-inch lap and 6-inch o.c. in two, (Optional) BP -AA, SBS-AA, SBS-AA, SBS TA -90.0 W-30 inch plywood Elastobase Simplex MAXX Cap equally spaced, staggered center rows SBS-TA or APP-TA or APP-TA W-31 Min. 19/32- Elastobase or Elastobase Poly with 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 4-inch o.c. in 4-inch lap and 4-inch o.c. in four, (Optional) One or more SBS- SBS-SA, APP-SA, SBS-TA or APP- -97.5 inch plywood poly top surface annular ring shank nails, equally spaced, staggered center rows SA, SBS-TA or APP-TA TA W 32 Min. 19/32- Elastobase or Elastobase Poly with 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 4-inch o.c. in 4-inch lap and 4-inch o.c. in four, Polyflex SA Base APP-TA -97.5 inch plywood I poly top surface annular ring shank nails. I equally spaced, staggered center rows Exterior Research and Design, LLC. d/b/a Trinityl ERD Evaluation Report P9290.02.08-1113 for FL1654-R15 Certificate of Authorization #9503 Revision 13: 02/26/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 7 of 33 ,.l TRINITY J ERD TABLE 1E-1: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAiLs), BONDED ROOF COVER System Deck (See Base Sheet Roof Cover No. Note-1) Base — -- Fasten -Attach Ply Cap MDP (psf) W-33 Min. 15/32- Elastobase Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in (Optional) BP -AA, SBS-AA, SBS-AA, SBS-TA 105.0 inch plywood three, equally spaced, staggered center rows SBS-TA or APP-TA or APP-TA W 34 Min. 19/32- Elastobase or Elastobase Poly 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 6-inch o.c. in 4-inch lap and 6-inch o.c. in four, � SBS-AA(Optional) One or more BP- SBS-TA or APP- SBS-AA, SBS-TA, _112.5 inch plywood annular ring shank nails equally spaced, staggered center rows , APP-TA TA Min. 2- Elastobase or Elastobase Poly with 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 6-inch o.c. in 4-inch lap and 6-inch o.c. in four, (Optional) Elastoflex SA V SBS-SA, APP-SA, W-35 inch plywood poly top surface annular ring shank nails. Note: Tin caps are to be equally spaced, staggered center rows Plus, Elastoflex SA V Plus FR, SBS-TA or APP- -112.5 primed with PG100 or ASTM D41 primer. SBS-TA or APP-TA TA W-36 Min. 19/32- Elastobase or Elastobase Poly with 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 6-inch o.c. in 4-inch lap and 6-inch o.c. in four, inch plywood p yw poly top surface annular ring shank nails. Note: Tin caps are to be equally spaced, staggered center rows Polyflex SA Base APP-TA -112.5 primed with PG100 or ASTM D41 primer. TABLE 1E-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) ORRECOVER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System Deck (See Base Sheet Roof Cover No. Note 1) Base Fasten Attach Ply Cap MDP (psf) Elastobase, Elastobase Poly, Min. Polyglass G2 Base, CertainTeed OMG Flat Bottom Plates (square) with Roofgrip 12-inch in 4-inch lap and 12cinch i (Optional) One or more BP- SBS-AA, SBS-TA, W 37 l w2- inch plywood Glasbase, Firestone MB Base, JM #14, Dekfast Hex with Dekfast #14 orTruFast all s two, equally spaced, staggered center rows r rows AA SBS-AA, SBS-TA or APP- APP TA _52.5 Perma-Ply 28, Tamko Glass Base MP-3 with TruFast HD TA or GAFGLAS #75 W-38 Min. 19/32- Elastobase or Elastobase Poly with Dekfast Hex with Dekfast #14 or TruFast MP-3 12-inch o.c. in 4-inch lap and 12-inch o.c. in One or more SBS-SA SBS-SA, APP-5A, SB5-TA or APP- -52.5 * inch plywood p y poly top surface with TruFast HD two, equally spaced, staggered center rows TA W 39 Min. 19/32- Elastobase or Elastobase Poly with Dekfast Hex with Dekfast #14 orTruFast MP-3 12-inch o.c. in 4-inch lap and 12-inch o.c. in Polyflex SA Base APP-TA 52.5 * inch plywood poly top surface with TruFast HD two, equally spaced, staggered center rows Min. 19/32- OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. in 4-inch lap and 12-inch o.c. in (Optional) One or more BP- SBS-AA, SBS-TA, W-40 inch plywood Elastobase or Elastobase Poly #12 two, equally spaced, staggered center rows A, SB5-AA, SBS-TA or APP- APP-TA -60.0 W-41 Min. 19/32- Elastobase or Elastobase Poly with OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. in 4-inch lap and 12-inch o.c. in One or more SBS-SA SB5-SA, APP-SA, SBS-TA or APP- -60.0* inch plywood poly top surface #12 two, equally spaced, staggered center rows TA W 42 Min. 19/32- Elastobase or Elastobase Poly with OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. in 4-inch lap and 12-inch o.c. in Polyflex SA Base APP-TA -60.0* inch plywood poly top surface #12 two, equally spaced, staggered center rows Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report P9290.02.08-R13 for F1.1654-1115 Revision 13: 02/26/2015 Appendix 1, Page 8 of 33 . J. v I RINITY ERD TABLE 1E-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) ORRECOVER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System Deck (See Base Sheet Roof Cover MDP No. Note-1) Base Fasten Attach Ply Cap (psf) Min. OMG #12 Standard Roofgrip or OMG #14 Heavy o.c. at 4-inch lap and 6 inch o.c. in W-43 inch plywood plywood Pol lass APP Base Yg Du Duty (min. 1-5/8-inch long) with OMG 3" Round three, equally spaced, staggered center rows three, (Optional) APP-TA APP-TA -90.0 Metal Plates or OMG Flat Bottom Metal Plates Min. 15/32- OMG #12 Standard Roofgrip or OMG #14 Heavy 6-inch o.c. at 4-inch lap and 6-inch o.c. in (Optional) BP -AA, SBS-AA, SBS-AA, SBS-TA W-44 inch plywood Elastobase (with sand top surface) Duty (min. 1-5/8-inch long) with OMG 3" Round three, equally spaced, staggered center rows SBS-TA or APP-TA or APP-TA -90.0 Metal Plates or OMG Flat Bottom Metal Plates W-45 Min. 15/32- Elastobase (with sand top surface) Trufast #12 DP or Trufast #14 HD (min. 1-5/8-inch 6-inch o.c. at 4-inch lap and 6-inch o.c. in (Optional) BP -AA or SBS-AA SBS-AA -90.0 inch plywood long) with Trufast 3" Metal Insulation Plates three, equally spaced, staggered center rows Min. 15/32- OMG #12 Standard Roofgrip or OMG #14 Heavy 6-inch o.c. at 4-inch lap and 6-inch o.c. in five, W-46 inch I plywood Polyglass APP Base Duty (min. 1-5/8-inch long) with OMG 3" Round equally spaced, staggered center rows (Optional) APP-TA APP-TA -120.0 Metal Plates or OMG Flat Bottom Metal Plates Min. 15/32- #12 Standard Roofgrip or OMG #14 Heavy 6-inch o.c. at 4-inch lap and 6-inch o.c. in five, (Optional) BP -AA, SBS-AA, SBS-AA, SBS-TA W-47 inch plywood Elastobase with sand to surface ( P ) Duty (min. 1-5/8-inch long) with OMG 3" Round equally spaced, staggered center rows SBS-TA or APP-TA or APP-TA -120.0 Metal Plates or OMG Flat Bottom Metal Plates W 48 Min. 15/32- Elastobase (with sand top surface) Trufast #12 DP or Trufast #14 HD (min. 1-5/8-inch 6-inch o.c. at 4-inch lap and 6-inch o.c. in five, (Optional) BP -AA or SBS-AA SBS-AA 120.0 inch plywood long) with Trufast 3" Metal Insulation Plates equally spaced, staggered center rows TABLE 1F: WOOD DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System Deck (See Primer Roof Cover MDP (psf) Joint Treatment Base Ply Cap No. Note 1) Min. 15/32- (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- W 49 plywood I ood (Optional) PG100 None SBS-SA TA, APP-TA TA, APP-TA -90.0 W-50 Min. 15/32- (Optional) PG100 None Polyflex SA Base (Optional) One or more App-TA -90.0 inch plywood APP-TA W-51 Min. 15/32- (Optional) PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA V Base or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- 97.5 inch plywood place to create continuous bond. Elastoflex SA VFR Base TA, APP-TA TA, APP-TA Min. 15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA V Plus or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- 135.0 W 52 inch plywood (Optional) PG100 place to create continuous bond. Elastoflex SA V Plus FR TA, APP-TA TA, APP-TA W-53 Min. 15/32- (Optional) PG100 Plywoodjoints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into polyflex SA Base (Optional) One or more APP TA 135.0 inch plywood place to create continuous bond. APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Evaluation Report P9290.02.08-1113 for FL1654-R15 Certificate of Authorization #9503 Revision 13: 02/26/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 9 of 33 Florida Building Code Online r Page 1 01 J ����k��✓��i"'� ��!'£C,t.�i'� � '-r.�c ° �'�° � iP�lP,� '�i�`5'S �� '" '`��1��ca+e �f � �.✓" , oq y C' .•k • / V f' � `r 1 4 BCIS Home Lod In User Reglstration i Hot Topics ' Submit Surcharge ` Stats & Facts ' Publications F8C Staff = BCIS Site Map !Links ;Search Busines��'� awl-ja. Product Approval ProfessionalUSER: Pubilc User Product Approval Menu > Product or Application Search > Application List > Application Detail x.naigv FL # FL12769-R2 .. _ ..,: Application Type Revision 0 Code Version 2010 FILE CA"6PY Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary. Comments Archived Product Manufacturer JELD-WEN Address/Phone/Email 3737 Lakeport Blvd Klamath Falls, OR 97601 (800)535-3936 fbcl@jeld-wen.com Authorized Signature Janet Gerard fbcl@jeld-wen.com Technical Representative JELD-WEN Corporate Customer Service Address/Phone/Email 3737 Lakeport Blvd. Klamath Falls, OR 97601 (800)535-3936 customerserviceagents@jeld-wen.com Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute, Referenced Standard and Year (of Standard) Standard Year ASTM E330 2002 ASTM E331 2000 TAS202 1994 Equivalence of Product Standards Certified By i 7 // http://www. floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsmFBcODh9X... 12/28/2014 -Yldrida Building Code Online Page 2 of 3 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option A 03/07/2013 03/07/2013 03/14/2013 Summary of Products�— FL # Model, Number or Name Description 12769.1 Contour Premium Steel Wood 12'-0" x 6'-8", Glazed, Steel, Wood Edge, Inswing Door Edge Glazed Door System with and without Sidelites Limits of Use Certification Agency Certificate Approved for use In HVHZ: Yes FL12769 R2 C CAC NI009887-R2.1)df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 03/31/2017 Design Pressure: +55/-55 Installation Instructions Other: Product Can Be Installed In The X, OX/XO, OXO, FL12769 R2 II A008730 SS.Pdf XX, OXX/XXO, and OXXO Configurations Per Installation Verified By: Hermes F. Norero Florida PE No. 73778 Instructions. Since product does not meet water Created by Independent Third Party: Yes Infiltration requirement for HVHZ, it must be Installed per Evaluation Reports overhead requirements as identified in Sec. 4410.2.3.2 FL12769 R2 AE PER2292 SS.pdf of the Florida RBC. Created by Independent Third Party: Yes 12769.2 Premium Steel Wood 12'-0" x 6'-8", Glazed, Steel, Wood Edge, Inswing Door :�::]Contour Edge Glazed Door jSystem with and without Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL12769 R2 C CAC NI009887-R2.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 03/31/2017 Design Pressure: +66/-66 Installation Instructions Other: Product Can Be Installed In The X, OX/XO, OXO, FL12769 R2 II A008730 SS.pdf XX, OXX/XXO, and OXXO Configurations Per Installation Verified By: Hermes F. Norero Florida PE No. 73778 Instructions; and Must Be Installed With Surface Bolts. Created by Independent Third Party: Yes Since product does not meet water infiltration Evaluation Reports i requirement for HVHZ, it must be Installed per overhead FL12769 R2 AE PER2292 SS.odf requirements as identified in Sec. 4410.2.3.2 of the Created by Independent Third Party: Yes Florida RBC. j 12769.3 Contour Premium Steel Wood 12'-0' x 6'-8", Glazed, Steel, Wood Edge, Outswing Door Edge Glazed Door System with and without Sidelites � i Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL12769 R2 C CAC NI009887-R2.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 03/31/2017 Design Pressure: +55/-55 Installation Instructions Other: Product Can Be Installed In The X, OX/XO, OXO, FL12769 R2 II A008731 SS.pdf XX, OXX/XXO, and OXXO Configurations Per Installation Verified By: Hermes F. Norero Florida PE No. 73778 Instructions. Since product does not meet water Created by Independent Third Party: Yes Infiltration requirement for HVHZ, It must be Installed per Evaluation Reports overhead requirements as Identified in Sec. 4410.2.3.2 FL12769 R2 AE PER2293 SS.odf of the Florida RBC. Created by Independent Third Party: Yes 12769.4 Contour Premium Steel Wood 12'-0" x 6'-8", Glazed, Steel, Wood Edge, Outswing Door Edge Glazed Door System with and without Sidelites Limits of Use Certification Agency Certificate Approved for use In HVHZ: Yes FL12769 R2 C CAC N]009887-R2.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 03/31/2017 Design Pressure: +66/-66 Installation Instructions Other: Product Can Be Installed In The X, OX/XO, OXO, FL12769 R2 II A008731 SS.pdf XX, OXX/XXO, and OXXO Configurations Per Installation Verifled By: Hermes F. Norero Florida PE No. 73778 Instructions; and Must Be Installed With Surface Bolts. Created by Independent Third Party: Yes Since product does not meet water Infiltration Evaluation Reports requirement for HVHZ, it must be Installed per overhead FL12769 R2 AE PER2293 SS.pdf requirements as identified in Sec. 4410.2.3.2 of the Created by Independent Third Party: Yes Florida RBC. ti I — k2769,5 Contour Premium Steel Wood 3-0 x 6-8, X, Single Out Swing Door with Vent Lite, Edge Glazed Door meets water Infiltration Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL12769 R2 C CAC NI011489.1)df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 01/31/2017 Design Pressure: +55/-55 Installation Instructions Other: Product meets water infiltration requirements for FL12769 R2 II A009078 SS.pdf http://www.floridabuilding. org/prlpr_app_dtl.aspx?param=wGEVXQwtDgsmFB cODh9X... 12/28/2014 Florida Building Code Online Page 3 of 3 HVHZ Verified By: Hermes F. Norero Florida PE No. 73778 Created by Independent Third Party: Yes Evaluation Reports FL12769 R2 AE PER2333 SS.Ddf Created by_Independent Third Party: Yes j Back Next Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® ,el,llxcl, 'acca sccuritystu rurr, http://www.floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsmFBcODh9X... 12/28/2014