HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online Page 1 of 2
u
a a►I►r•w -�
Business , Professional Regulation DIV . z,.. ..
Florida Departments BCIS Home I Log In I user Registration I Hot Topics . Submit S r e Ilcatlons I FBC Staff I BCIS Site Map I Links I Search
Busines
ProfessiI 11 Product Approval
�IeYr✓ USER: Public User
Regulation
Product Approval Menu > Product or Application Search > Application Us t > Application Detail
• FL # FL1654-R15
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived r
Product Manufacturer POLYGLASS USA
Address/Phone/Email 150 Lyon Drive
Fernley, NV 89408
(570)384-1230 Ext242
jakins@polyglass.com
Authorized Signature
James Akins
jakins@polyglass.com
Technical Representative
Steve Wadding
Address/Phone/Email
150 Lyon Drive
Fernley, NV 98408
(602) 363-7139
stevew@polyglass.com
Quality Assurance Representative
James Akins
Address/Phone/Email
555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800)894-4563
jakins@polyglass.com
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
71 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who
Robert Nleminen
developed the Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
06/27/2016
Validated By
John W. Knezevich, PE
r✓ Validation Checklist - Hardcopy Received
Certificate of Independence FL1654 R15 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year (of Standard) Standard Year
ASTM D6163 2000
ASTM D6164 200�
fig
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFg... 7/8/2015
. Florida Building Code Online
Page 2 of 2
ASTM D6222 2008
ASTM D6509 2009
FM 4470 1992
FM 4474 2004
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
02/27/2015
Date Validated
03/01/2015
Date Pending FBC Approval
03/04/2015
Date Approved
04/15/2015
Date Revised
06/17/2015
lmmary of Prnrlllrt•e
FL #
Model, Number or
11
Description
Name
1654.1
Polyglass SBS and APP
d APP modifled bitumen roof systems
Modified Bitumen Roof
Ir
Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL1654 R15 II 2015 02 FINAL Al ER POLYGLASS MODBIT FL1654-
R15.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this
Evaluation Reports
application relates to one particular
FL1654 R15 AE 2015 02 FINAL ER POLYGLASS MODBIT FL1654-
R15.Ddf
assembly over concrete deck. Refer to the
ER Appendix for other systems and deck
Created by Independent Third Party: Yes
types. 2.) Refer to ER, Section 5 for other
Limits of Use.
Back Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.
.Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department
with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public
record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
a® eChcsl
tiCCUt7t AI I:TNICS'
http://www. floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFg... 7/8/2015
��TRRINI*ERD
I 'APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT, RESISTANCE
II
Table
Deck
Application
Type
Description
Page
1A-1
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
4
1A-2
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5
1B
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
5
1C
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
6
1D
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
6
1E-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
7-8
jE-2
Wood
eurReroof=(Tear-O orecover -
E—__—____Non-Insulated; Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover T
8-9
1F
Wood
ew or Reroof-(Tear-Off)
F
No`n-Insu ated, Bonded Roof Cover
9
2A
Steel or Conc.
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
10
2B
Steel or Conc.
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
11
2C
Steel or Conc.
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
12-13
3A-1
Concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
14-17
3A-2
Concrete
New or Reroof (Tear -Off)
A-1
Bonded Temporary Roof, Bonded Insulation, Bonded Roof Cover
18-19
3B
Concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
19
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
20-21
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
22
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
23-25
SA
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
26
SB
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
27
5C
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
28
5D
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
28
5E
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
28
6A
Gypsum
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
29
6B
Gypsum
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded insulation, Bonded Roof Cover
30
6C
Gypsum
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
30
6D
Gypsum
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
30
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
31-33
7B
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
33
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the
roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
➢ Wood: Minimum 0.75-inch penetration.
➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
➢ Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, Dens Deck, Dens Deck Prime, SECUROCK Gypsum -Fiber Roof Board or SECUROCK
Glass -Mat Roof Board that meets the CIA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover.
Exterior Research and Design, I.I.C. d/b/a Trinity] ERD Evaluation Report P9290.02.08-1113 for FL1654-R15
Certificate of Authorization #9503 �— Revision 13: 02/26/2015
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 1 of 33
��TRINITYIERD
4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
S. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturers published instructions.
➢ HA (HA): Full coverage at 25-30 Ibs/square.
➢ Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c.
➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is
referenced.
➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
➢ 3M CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c.
➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocya n u rate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table:
➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick)
➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3)
➢ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+GL)
➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3)
➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II)
➢ 3M CR-20: MDP -117.5 psf (Min. 1.0-inch thick)
7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
f8 For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
!J Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29.
Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements.
9` For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted.
For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1.
11. For existing substrates in a bonded recover installation, the existing roof system shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of
resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124.
12. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
13. LWIC shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck
construction and limitations. For systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWIC over structural concrete,
reference is made to FBC Section 1917.4.1, Point 1.
Exterior Research and Design, I.I.C. d/b/a Trinity1 ERD Evaluation Report P9290.02.08-1113 for FL1654-R15
Certificate of Authorization #9503 Revision 13: 02/26/2015
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 33
r
14. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
TABLE 1: POLYGLASs ROOFCOVERS It
Reference
Layer
Material
Application
BP -AA
Base
Polyglass G2 Base, FBC Approved ASTM D4601, Type II
HA 20-40 Ibs/square
(Base and Ply sheets, Asphalt -Applied)
Ply
Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI
at
SBS-AA
Base or Ply
Elastobase, Elastobase Poly, Elastoflex V, Elastoflex S6
HA at 20-40 Ibs/square
(SBS, Asphalt -Applied)
Cap
Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko G SBS, Polyfresko G SBS FR
SBS-TA
Base or Ply
Elastoflex V, Elastoflex S6
(SBS, Torch -Applied)
Cap
Elastoflex V, Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko G SBS,
Torch -Applied
Polyfresko G SBS FR
SBS-SA
Base
Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR
Self -Adhering
(SBS, Self -Adhering)
Cap
Elastoflex SA P, Elastoflex SA P FR, Polyreflect
APP-TA
Base or Ply
Polyglass APP Base, Polyflex, Polybond
Torch -Applied
(APP, Torch -Applied)
Cap
Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR
APP-SA
Cap
Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool
Self -Adhering
g
(APP, Self -Adhering)
15. Any of the following FBC Approved coatings maybe applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings
associated with coating usage.
➢ PG200 Non Fibered Roof Coating or Mule -Hide 111 Non-Fibrated Roof Coating;
➢ PG300 Fibered Roof Coating or Mule -Hide 102 Fibrated Roof Coating;
➢ PG600 Non-Fibered Aluminum Roof Coating or Mule -Hide 416 Standard Non-Fibrated Aluminum Roof Coating;
➢ PG650 Fibered Aluminum Roof Coating or Mule -Hide 406 Standard Fibrated Aluminum Roof Coating;
➢ PG700 High Quality Elastomeric Roof Coating;
➢ PG800 Asphalt Emulsion Roof Coating or Mule -Hide 311 Emulsion Non-Fibrated;
➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating or Mule -Hide 410 Premium Non-Fibrated Aluminum Roof Coating;
➢ Polyplus 65 Premium Fibered Aluminum Roof Coating or Mule -Hide 401 Premium Fibrated Aluminum Roof Coating;
➢ Polybrite 70 Premium Grade Elastomeric Roof Coating;
➢ Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating.
16. The following represent priming requirements for gypsum -based coverboards:
➢ Dens Deck and Dens Deck Prime shall be field -primed with PG300 prior to self -adhering or torch -applied membrane application. No priming is required for hot -asphalt membrane applications.
➢ SECUROCK Gypsum -Fiber Roof Board does not require field priming for any membrane application.
17. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report P9290.02.08-1113 for FL1654-1115
Certificate of Authorization #9503 Revision 13: 02/26/2015
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 3 of 33
M
',,I TRINITY ERD
TABLE 1A-1: WOOD DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF)
SYSTEM TYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
Deck
Anchor Sheet
Base Insulation
Top Insulation
Roof Cover
MDP
No.
(See Note 1)
Type
Fasten
Attach
Type
Attach
Type -
Attach
Base
Ply
Cap
(Psf)
Min. 0.25-inch Dens Deck,
Polyglass G2 Base,
32 ga., 1-5/8-
8-inch o.c. in 4-inch
Dens Deck Prime, SECUROCK
CertainTeed Glasbase,
inch diameter tin
lap and 8-inch o.c.
(Optional) FBC
Gypsum -Fiber Roof Board,
BP -AA
(Optional)
SBS-AA,
W-1
19/32-
Firestone MB Base,JM
,
caps with 11 ga.
in three, equally
Approved,
HA
Min. 0.75-inch Fesco Board
HA
or SBS-
BP -AA or
SBS-TA,
-60.0
inch plywood
Perma-Ply 28, Tamko
annular ring
spaced, staggered
ASTM C1289
(homogeneous) or min. 0.5-
AA
SBS-AA
APP-TA
Glass Base or GAFGLAS
shank nails
center rows
polyiso
inch Structodek High Density
#75
Fiberboard Roof Insulation
Polyglass G2 Base,
CertainTeed Glasbase,
32 ga., 1-5/8-
8-inch o.c. in 4-inch
(Optional) FBC
(Optional)
SBS-SA,
Min. 19/32-
Firestone MB Base, JM
inch diameter tin
lap and 8-inch o.c.
Approved,
Min. 0.25-inch Dens Deck,
One or
gpp_SA ,
W-2
caps with 11 ga.
in three, equally
HA
Dens Deck Prime, SECUROCK
HA
SBS-SA
more SBS-
SBS-TA,
-60.0
inch plywood
Perma-Ply 28, Tamko
annular ring
spaced, staggered
ASTM C1289
Gypsum -Fiber Roof Board
SA, SBS-TA,
APP-TA
Glass Base or GAFGLAS
shank nails
center rows
polyiso
APPTA
#75
Polyglass G2 Base,
CertainTeed Glasbase,
32 ga., 1-5/8-
8-inch o.c. in 4-inch
(Optional) FBC
(Optional)
Min. 19/32-
Firestone MB Base, JM
inch diameter tin
lap and 8-inch o.
Approved ,
Min. 0.25-inch Dens Deck,
Polyflex
One orc.
APP-TA
-60.0
W-3
inch plywood
Perma-Ply 28, Tamko
caps with 11 ga.
in three, equally
ASTM C1289
HA
Dens Deck Prime, SECUROCK
HA
SA Base
more APP-
Glass Base or GAFGLAS
annular ring
spaced, staggered
polyiso
Gypsum -Fiber Roof Board
TA
#75
shank nails
center rows
Min. 2-inch
D-IS, OB500,
32 ga., 1-5/8-
inch diameter tin
6-inch o.c. in 4-inch
lap and 6-inch o.c.
ACFoam II, III,
CR-20 or M-
Min. 0.25-inch Dens Deck,
D-IS,
BP -AA
(Optional)
SBS-AA,
W-4
Min. 19/32-
Elastobase or
caps with 12 ga.
in four, equally
H-Shield, H-
OSFA, atop
Dens Deck Prime or
OB500,
or SBS-
BP -AA or
SBS-TA,
-60.0*
inch plywood
Elastobase Poly
annular ring
spaced, staggered
Shield CG,
fastener
SECUROCK Gypsum -Fiber
CR-20 or
AA
SBS-AA
APP-TA
Multi -Max FA3
rows, 7-inch
Roof Board
M-OSFA
shank nails
center rows
or ENRGY-3
O.C.
32 ga.,1-5/8-
6-inch o.c. in 4-inch
Min. 2-inch
D-IS, OB500,
D-IS,
(Optional)
SBS-SA,
Min. 19/32-
Elastobase or
inch diameter tin
lap and 6-inch o.c.
ACFoam II, III,
H-Shield, H-
CR-20 or M-
OSFA, atop
(Optional) Additional layers
OB500,
SBS-SA
One or
more SBS-
APP-SA,
60.0*
W-5
inch plywood
Elastobase Poly
caps with 12 ga.
in four, equally
Shield CG,
fastener
of base insulation
CR-20 or
SA, SBS-TA,
SBS-TA,
annular ring
spaced, staggered
Multi -Max FA3
rows, 7-inch
M-OSFA
APP-TA
qpp-TA
shank nails
center rows
or ENRGY-3
O.C.
32 ga., 1-5/8-
6-inch o.c. in 4-inch
Min. 2-inch
ACFoam II, III,
D-IS, OB500,
CR-20 or M-
D-IS,
(Optional)
Min. 19/32-
Elastobase or
inch diameter tin
lap and 6-inch o.c.
H-Shield, H-
OSFA, atop
(Optional) Additional layers
OB500,
Polyflex
One or
APP TA
-60.0*
W-6
inch plywood
Elastobase Poly
caps with 12 ga.
in four, equally
Shield CG,
fastener
of base insulation
CR-20 or
SA Base
more APP-
annular ring
spaced, staggered
Multi -Max FA3
rows, 7-inch
M-OSFA
TA
shank nails
center rows
or ENRGY-3
O.C.
Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Evaluation Report P9290.02.08-1113 for FL1654-1135
Certificate of Authorization #9503 Revision 13: 02/26/2015
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 4 of 33
TABLE 1A-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
Deck
Anchor Sheet
Base Insulation
Top insulation
Roof Cover
MDP (psf)
No.
(See Note 1)
Type
Fasten
Attach
Type
Attach
Type
Attach
Base
Ply
Cap
Min. 0.25-inch Dens Deck, Dens
12-inch o.c. in 4-
Deck Prime, SECUROCK Gypsum -
OMG Flat Bottom
inch lap and 12-
(Optional) FBC
Fiber Roof Board, Min. 0.75-inch
(Optional)
SBS-AA,
W-7
Min. 19/32-
Elastobase or
Plates (square)
inch o.c. in two,
Approved, ASTM
HA
Fesco Board (homogeneous) or
HA
BP -AA or
BP -AA or
SBS-TA,
-60.0
inch plywood
Elastobase Poly
with Roofgrip #12
equally spaced,
C1289, type 11
min. 0.5-inch Structodek High
SBS AA
SBS-AA
APP-TA
staggered center
polyiso-cyanurate
Density Fiberboard Roof
rows
Insulation
12-inch o.c. in 4-
(Optional)
OMG Flat Bottom
inch lap and 12-
(Optional) FBC
Min. 0.25-inch Dens Deck, Dens
One or
SBS-SA,
W-8
Min. 19/32-
Elastobase or
Plates (square)
inch o.c. in two,
Approved, ASTM
HA
Deck Prime, SECUROCK Gypsum-
HA
SBS-SA
more SBS-
APP-SA,
-60.0
inch plywood
Elastobase Poly
with Roofgrip #12
equally spaced,
C1289, type 11
Fiber Roof Board
SA, SBS-TA,
SBS-TA,
staggered center
polyiso-cyanurate
APP TA
APP-TA
rows
12-inch o.c. in fl-
OMG Flat Bottom
inch lap and 12-
(Optional) FBC
Min. 0.25-inch Dens Deck, Dens
(Optional)
W-9
Min. 19/32-
Elastobase or
Plates (square)
inch o.c. in two,
Approved, ASTM
HA
Deck Prime, SECUROCK Gypsum-
HA
Polyflex SA
One or
APP-TA
-60.0
inch plywood
Elastobase Poly
with Roofgrip #12
equally spaced,
C1289, type II
Fiber Roof Board
Base
more APP-
staggered center
polyiso-cyanurate
TA
rows
TABLE 1B: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
Deck (See
Base Insulation Layer
Top Insulation Layer
Roof Cover
MDP (psf)
No.
Note 1)
Type
Fasten
Attach
Type
Attach
Base
Ply
Cap
Min.1.5-inch ENRGY
Dekfast Hex with Dekfast
Min. 0.75-inch Fesco Board
(Optional if
(Optional if using AA
SBS-AA,
W-10
Min. 19/32-
3, H-Shield or
#12 orTruFast MP-3 with
1 per 1.33 ftz
(homogeneous) or min. 0.5-inch
HA
using AA Ply)
Base) One or more BP-
SBS-TA,
-60.0
inch plywood
Polytherm
TruFast DP
Structodek High Density Fiberboard
BP -AA, SBS-
AA, SBS-AA, SBS-TA or
APP-TA
Roof Insulation
AA
APP-TA
Exterior Research and Design, LLC, d/b/a Trinity I ERD Evaluation Report P9290.02.08-1113 for F1.1654-1115
Certificate of Authorization #9503 Revision 13: 02/26/2015
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 5 of 33
\l I {�NI*ERD
TABLE 1C: WOOD DECKS— NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
Deck (See
Top Insulation Layer
Roof Cover
No.
Note 1)
Base Insulation Layer
MDP (psf)
-
Type
Fasten
Attach
Base
ply
Cap
(Optional) One or more
Min. 0.5-inch Structodek High Density
(Optional using
(Optional if using AA Base)
W-11
Min. 19/32-
layers, any combination,
Fiberboard Roof Insulation or min. 0.25-
Dekfast Galvalume Steel Hex
1 per
AA Ply) BP -AA, SBS-
One more BP -AA, SBS-
SBS-AA, SBS-TA,
82.5
inch plywood
loose laid
inch Dens Deck, Dens Deck Prime or
with Dekfast #12 DP
1.33 ft2
AA
AA, SBS-TA or APP-TA
APP-TA
SECUROCK Gypsum -Fiber Roof Board
Min. 19/32-
(Optional) One or more
Min. 1.5-inch ENRGY 3, H-Shield or
Dekfast Galvalume Steel Hex
1 per
(Optional) One or more
SBS-SA, APP-SA,
W 12
inch plywood
layers, any combination,
Polytherm
with Dekfast #12 DP or
1.33 ft2
SBS-SA
SBS-SA, SBS TA, APP-TA
SBS-TA, APP TA
82.5
loose laid
TruFast MP-3 with TruFast DP
Min. 19/32-
(Optional) One or more
Min. 1.5-inch ENRGY 3, H-Shield or
Dekfast Galvalume Steel Hex
1 per
(Optional) One or more
W-13
inch plywood
layers, any combination,
Polytherm
with Dekfast #12 DP or
1.33 ft'
Polyflex SA Base
APP TA
APP-TA
-82.5
loose laid
TruFast MP-3 with TruFast DP
TABLE 1D: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER
SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
Deck (See
Insulation Layer(s)
Base Sheet
Roof Cover
No.
Note 1)
Type
ype
Attach
Base
Fasten
Attach
Ply
Cap
{psf)
One or more
Elastobase, Elastobase Poly, Polyglass
OMG Flat Bottom Plates (square)
12-inch o.c, in 4-inch lap and 12-
(Optional) One or
SBS-AA,:
W-14
Min. 19/32-
layers, any
Prelim.
G2 Base, CertainTeed Glasbase,
with Roofgrip #14, Dekfast Hex with
inch o.c. in two, equally spaced,
more BP -AA, SBS-AA,
SBS-TA,
-52.5
inch plywood
combination
Attached
Firestone MB Base, JM Perma-Ply 28,
Dekfast #14 or TruFast MP-3 with
staggered center rows
SBS-TA or APP-TA
APP-TA
Tamko Glass Base or GAFGLAS #75
TruFast HD
Min. 19/32-
One or more
Prelim.
Elastobase or Elastobase Poly with
Dekfast Hex with Dekfast #14 or
12-inch o.c. in 4-inch lap and 12-
SBS-SA,,
APP-SA,
W-15
inch plywood
layers, any
Attached
poly top surface
TruFast MP-3 with TruFast HD
inch o.c. in two, equally spaced,
One or more SBS-SA
SBS-TA or
-52.5*
combination
staggered center rows
APP-TA
Min. 19/32-
One or more
Prelim.
Elastobase or Elastobase Poly with
Dekfast Hex with Dekfast #14 or
12-inch o.c. in 4-inch lap and 12-
W-16
inch plywood
p
layers, any
Attached
poly top surface
TruFast MP-3 with TruFast HD
inch o.c. in two, equally spaced,
Polyflex SA Base
APP-TA
-52.5*
combination
staggered center rows
Min. 19/32-
One or more
Prelim.
OMG Flat Bottom Plates (square)
12-inch o.c. in 4-inch lap and 12-
(Optional) One or
SBS-AA,
W 17
inch plywood
layers, any
Attached
Elastobase or Elastobase Poly
with Roofgrip #12
inch o.c. in two, equally spaced,
more BP -AA, SBS-AA,
SBS-TA,
-60.0
combination
staggered center rows,
SBS-TA or APP-TA
APP-TA
Min. 19/32-
One or more
Prelim.
Elastobase or Elastobase Poly with
OMG Flat Bottom Plates (square)
12-inch o.c. in 4-inch lap and 12-
SBS-SA, ,
APP-SA
W-18
inch plywood
layers, any
Attached
poly top surface
with Roofgrip #12
inch o.c. in two, equally spaced,
One or more SBS-SA
SBS-TA or
-60.0*
combination
staggered center rows
APP-TA
Min. 19/32-
One or more
Prelim.
Elastobase or Elastobase Poly with
OMG Flat Bottom Plates (square)
12-inch o.c. in 4-inch lap and 12-
W 19
inch plywood
P
layers, any
Attached
poly top surface
with Roofgrip #12
inch o.c. in two, equally spaced,
Polyflex SA Base
APP-TA
-60.0*
combination
staggered center rows
Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report P9290.02.08-1113 for FL1654-1115
Certificate of Authorization #9503 Revision 13: 02/26/2015
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 6 of 33
VT---RR1N1TY I ERD
TABLE 1E-1: WOOD DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF)
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER
System
Deck (See
Base Sheet
Roof Cover
MDP (psf)
No.
Note 1)
Base
Fasten
Attach
Ply
Cap
W 20
Min. 15/32-
Elastobase
Simplex MAXX Cap
9-inch o.c. at 2-inch lap and 18-inch o.c. in
(Optional) BP -AA, SBS-AA,
SBS-AA, SBS-TA
45 0'
inch plywood
two, equally spaced, staggered center rows
SBS-TA or APP-TA
or APP TA
Min. 15/32-
9-inch o.c. at 2-inch lap and 12-inch o.c. in
(Optional) BP -AA, SBS-AA,
SBS-AA, SBS-TA
W-21
inch plywood
Elastobase
Simplex MAXX Cap
two, equally spaced, staggered center rows
SBS-TA or APP-TA
or APP-TA
-52.5
W-22
Min. 15/32-
Polyglass APP Base
Original Simplex Cap Nails (1-inch metal head
diameter, 11 gauge min. 1.25-inch long annular
6-inch o.c. at 3-inch lap and 6-inch o.c. in four,
(Optional) SBS-SA or APP TA
SBS-SA, APP-SA
-52.5
inch plywood
grooved shank)
equally spaced, staggered center rows
or APP-TA
Min.
Original Simplex Cap Nails (1-inch metal head
o in four,
o.c. at 3-inch lap and 6-ter
W-23
inch plywood
plywood
Polyglass APP Base
diameter, 11 gauge min. 1.25-inch long annular
sc.
r
equally spaced, staggered center rows
equally
Polyflex SA Base
APP-TA
-52.5
grooved shank)
Min.
Original Simplex Cap Nails (1-inch metal head
6-inch o.c. at 3-inch lap and o in four,
(Optional) SBS-SA, SBS-TA or
SBS-SA, APP-SA,
W 24
inch plywood
plywood
Elastobase (with poly top surface)
diameter, 11 gauge min. 1.25-inch long annular
enter r s
equally spaced, staggered center rows
APP-TA
SBS TA or APP-
-52.5
grooved shank)
TA
Min. 15/32-
Original Simplex Cap Nails (1-inch metal head
Original
6-inch o.c. at 3-inch lap and in four,
oows
W 25
inch plywood
Elastobase (with poly top surface)
diameter, 11 gauge x min. 1.25-inch long annular
equally spaced, staggered center renter r s
Polyflex SA Base
APP-TA
-52.5
grooved shank)
Min. 15/32-
Original Simplex Cap Nails (1-inch metal head
6-inch o.c. at 3-inch lap and 6-inch o.c. in four,
(Optional) BP -AA, SBS-AA,
SBS-AA, SBS-TA
-52.5
W-26
inch plywood
Elastobase (with sand top surface)
diameter, 11 gauge x min. 1.25-inch long annular
equally spaced, staggered center rows
SBS-TA or APP-TA
or APP-TA
grooved shank)
Elastobase, Elastobase Poly,
Min. 19/32-
Polyglass G2 Base, CertainTeed
32 ga., 1-5/8-inch diameter tin caps with 11 ga.
8-inch o.c. in 4-inch lap and 8-inch o.c. in
(Optional) One or more BP-
SBS-AA, SBS-TA,
W 27
inch plywood
Glasbase, Firestone MB Base, JM
annular ring shank nails
three, equally spaced, staggered center rows
AA SBS-AASBS-TA or APP-
,
APP TA
-60.0
Perma-Ply 28, Tamko Glass Base
TA
or GAFGLAS #75
Min. 19/32-
Elastobase or Elastobase Poly with
32 ga., 1-5/8-inch diameter tin caps with 11 ga.
8-inch o.c. in 4-inch lap and 8-inch o.c. in
(Optional) One or more SB5-
SBS-SA, APP-SA,
SBS-TA or APP-
-60.0
W 28
inch plywood
P Y
of to surface
poly P
annular ring shank nails
g
three, equally spaced, staggered center rows
q Y p gg
SA, SBS-TA or APP-TA
TA
W 29
Min. 19/32-
Elastobase or Elastobase Poly with
32 ga., 1-5/8-inch diameter tin caps with 11 ga.
8-inch o.c. in 4-inch lap and 8-inch o.c. in
Polyflex SA Base
APP-TA
-60.0
inch plywood
poly top surface
annular ring shank nails
three, equally spaced, staggered center rows
Min. 15/32-
6-inch o.c. at 2-inch lap and 6-inch o.c. in two,
(Optional) BP -AA, SBS-AA,
SBS-AA, SBS TA
-90.0
W-30
inch plywood
Elastobase
Simplex MAXX Cap
equally spaced, staggered center rows
SBS-TA or APP-TA
or APP-TA
W-31
Min. 19/32-
Elastobase or Elastobase Poly with
32 ga., 1-5/8-inch diameter tin caps with 11 ga.
4-inch o.c. in 4-inch lap and 4-inch o.c. in four,
(Optional) One or more SBS-
SBS-SA, APP-SA,
SBS-TA or APP-
-97.5
inch plywood
poly top surface
annular ring shank nails,
equally spaced, staggered center rows
SA, SBS-TA or APP-TA
TA
W 32
Min. 19/32-
Elastobase or Elastobase Poly with
32 ga., 1-5/8-inch diameter tin caps with 11 ga.
4-inch o.c. in 4-inch lap and 4-inch o.c. in four,
Polyflex SA Base
APP-TA
-97.5
inch plywood
I poly top surface
annular ring shank nails.
I equally spaced, staggered center rows
Exterior Research and Design, LLC. d/b/a Trinityl ERD Evaluation Report P9290.02.08-1113 for FL1654-R15
Certificate of Authorization #9503 Revision 13: 02/26/2015
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 7 of 33
,.l TRINITY J ERD
TABLE 1E-1: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF)
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAiLs), BONDED ROOF COVER
System
Deck (See
Base Sheet
Roof Cover
No.
Note-1)
Base
— -- Fasten
-Attach
Ply
Cap
MDP (psf)
W-33
Min. 15/32-
Elastobase
Simplex MAXX Cap
6-inch o.c. at 2-inch lap and 6-inch o.c. in
(Optional) BP -AA, SBS-AA,
SBS-AA, SBS-TA
105.0
inch plywood
three, equally spaced, staggered center rows
SBS-TA or APP-TA
or APP-TA
W 34
Min. 19/32-
Elastobase or Elastobase Poly
32 ga., 1-5/8-inch diameter tin caps with 11 ga.
6-inch o.c. in 4-inch lap and 6-inch o.c. in four,
� SBS-AA(Optional) One or more BP-
SBS-TA or APP-
SBS-AA, SBS-TA,
_112.5
inch plywood
annular ring shank nails
equally spaced, staggered center rows
,
APP-TA
TA
Min. 2-
Elastobase or Elastobase Poly with
32 ga., 1-5/8-inch diameter tin caps with 11 ga.
6-inch o.c. in 4-inch lap and 6-inch o.c. in four,
(Optional) Elastoflex SA V
SBS-SA, APP-SA,
W-35
inch plywood
poly top surface
annular ring shank nails. Note: Tin caps are to be
equally spaced, staggered center rows
Plus, Elastoflex SA V Plus FR,
SBS-TA or APP-
-112.5
primed with PG100 or ASTM D41 primer.
SBS-TA or APP-TA
TA
W-36
Min. 19/32-
Elastobase or Elastobase Poly with
32 ga., 1-5/8-inch diameter tin caps with 11 ga.
6-inch o.c. in 4-inch lap and 6-inch o.c. in four,
inch plywood
p yw
poly top surface
annular ring shank nails. Note: Tin caps are to be
equally spaced, staggered center rows
Polyflex SA Base
APP-TA
-112.5
primed with PG100 or ASTM D41 primer.
TABLE 1E-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) ORRECOVER
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER
System
Deck (See
Base Sheet
Roof Cover
No.
Note 1)
Base
Fasten
Attach
Ply
Cap
MDP (psf)
Elastobase, Elastobase Poly,
Min.
Polyglass G2 Base, CertainTeed
OMG Flat Bottom Plates (square) with Roofgrip
12-inch in 4-inch lap and 12cinch i
(Optional) One or more BP-
SBS-AA, SBS-TA,
W 37
l w2-
inch plywood
Glasbase, Firestone MB Base, JM
#14, Dekfast Hex with Dekfast #14 orTruFast
all s
two, equally spaced, staggered center rows
r rows
AA SBS-AA, SBS-TA or APP-
APP TA
_52.5
Perma-Ply 28, Tamko Glass Base
MP-3 with TruFast HD
TA
or GAFGLAS #75
W-38
Min. 19/32-
Elastobase or Elastobase Poly with
Dekfast Hex with Dekfast #14 or TruFast MP-3
12-inch o.c. in 4-inch lap and 12-inch o.c. in
One or more SBS-SA
SBS-SA, APP-5A,
SB5-TA or APP-
-52.5 *
inch plywood
p y
poly top surface
with TruFast HD
two, equally spaced, staggered center rows
TA
W 39
Min. 19/32-
Elastobase or Elastobase Poly with
Dekfast Hex with Dekfast #14 orTruFast MP-3
12-inch o.c. in 4-inch lap and 12-inch o.c. in
Polyflex SA Base
APP-TA
52.5 *
inch plywood
poly top surface
with TruFast HD
two, equally spaced, staggered center rows
Min. 19/32-
OMG Flat Bottom Plates (square) with Roofgrip
12-inch o.c. in 4-inch lap and 12-inch o.c. in
(Optional) One or more BP-
SBS-AA, SBS-TA,
W-40
inch plywood
Elastobase or Elastobase Poly
#12
two, equally spaced, staggered center rows
A, SB5-AA, SBS-TA or APP-
APP-TA
-60.0
W-41
Min. 19/32-
Elastobase or Elastobase Poly with
OMG Flat Bottom Plates (square) with Roofgrip
12-inch o.c. in 4-inch lap and 12-inch o.c. in
One or more SBS-SA
SB5-SA, APP-SA,
SBS-TA or APP-
-60.0*
inch plywood
poly top surface
#12
two, equally spaced, staggered center rows
TA
W 42
Min. 19/32-
Elastobase or Elastobase Poly with
OMG Flat Bottom Plates (square) with Roofgrip
12-inch o.c. in 4-inch lap and 12-inch o.c. in
Polyflex SA Base
APP-TA
-60.0*
inch plywood
poly top surface
#12
two, equally spaced, staggered center rows
Exterior Research and Design, I.I.C. d/b/a Trinity I ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R13 for F1.1654-1115
Revision 13: 02/26/2015
Appendix 1, Page 8 of 33
. J.
v I RINITY ERD
TABLE 1E-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) ORRECOVER
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER
System
Deck (See
Base Sheet
Roof Cover
MDP
No.
Note-1)
Base
Fasten
Attach
Ply
Cap
(psf)
Min.
OMG #12 Standard Roofgrip or OMG #14 Heavy
o.c. at 4-inch lap and 6 inch o.c. in
W-43
inch plywood
plywood
Pol lass APP Base
Yg
Du
Duty (min. 1-5/8-inch long) with OMG 3" Round
three, equally spaced, staggered center rows
three,
(Optional) APP-TA
APP-TA
-90.0
Metal Plates or OMG Flat Bottom Metal Plates
Min. 15/32-
OMG #12 Standard Roofgrip or OMG #14 Heavy
6-inch o.c. at 4-inch lap and 6-inch o.c. in
(Optional) BP -AA, SBS-AA,
SBS-AA, SBS-TA
W-44
inch plywood
Elastobase (with sand top surface)
Duty (min. 1-5/8-inch long) with OMG 3" Round
three, equally spaced, staggered center rows
SBS-TA or APP-TA
or APP-TA
-90.0
Metal Plates or OMG Flat Bottom Metal Plates
W-45
Min. 15/32-
Elastobase (with sand top surface)
Trufast #12 DP or Trufast #14 HD (min. 1-5/8-inch
6-inch o.c. at 4-inch lap and 6-inch o.c. in
(Optional) BP -AA or SBS-AA
SBS-AA
-90.0
inch plywood
long) with Trufast 3" Metal Insulation Plates
three, equally spaced, staggered center rows
Min. 15/32-
OMG #12 Standard Roofgrip or OMG #14 Heavy
6-inch o.c. at 4-inch lap and 6-inch o.c. in five,
W-46
inch I
plywood
Polyglass APP Base
Duty (min. 1-5/8-inch long) with OMG 3" Round
equally spaced, staggered center rows
(Optional) APP-TA
APP-TA
-120.0
Metal Plates or OMG Flat Bottom Metal Plates
Min. 15/32-
#12 Standard Roofgrip or OMG #14 Heavy
6-inch o.c. at 4-inch lap and 6-inch o.c. in five,
(Optional) BP -AA, SBS-AA,
SBS-AA, SBS-TA
W-47
inch plywood
Elastobase with sand to surface
( P )
Duty (min. 1-5/8-inch long) with OMG 3" Round
equally spaced, staggered center rows
SBS-TA or APP-TA
or APP-TA
-120.0
Metal Plates or OMG Flat Bottom Metal Plates
W 48
Min. 15/32-
Elastobase (with sand top surface)
Trufast #12 DP or Trufast #14 HD (min. 1-5/8-inch
6-inch o.c. at 4-inch lap and 6-inch o.c. in five,
(Optional) BP -AA or SBS-AA
SBS-AA
120.0
inch plywood
long) with Trufast 3" Metal Insulation Plates
equally spaced, staggered center rows
TABLE 1F: WOOD DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF)
SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER
System
Deck (See
Primer
Roof Cover
MDP (psf)
Joint Treatment
Base
Ply
Cap
No.
Note 1)
Min. 15/32-
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
W 49
plywood I ood
(Optional) PG100
None
SBS-SA
TA, APP-TA
TA, APP-TA
-90.0
W-50
Min. 15/32-
(Optional) PG100
None
Polyflex SA Base
(Optional) One or more
App-TA
-90.0
inch plywood
APP-TA
W-51
Min. 15/32-
(Optional) PG100
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Base or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
97.5
inch plywood
place to create continuous bond.
Elastoflex SA VFR Base
TA, APP-TA
TA, APP-TA
Min. 15/32-
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Plus or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
135.0
W 52
inch plywood
(Optional) PG100
place to create continuous bond.
Elastoflex SA V Plus FR
TA, APP-TA
TA, APP-TA
W-53
Min. 15/32-
(Optional) PG100
Plywoodjoints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
polyflex SA Base
(Optional) One or more
APP TA
135.0
inch plywood
place to create continuous bond.
APP-TA
Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Evaluation Report P9290.02.08-1113 for FL1654-R15
Certificate of Authorization #9503 Revision 13: 02/26/2015
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 9 of 33
Florida Building Code Online
r
Page 1 01 J
����k��✓��i"'� ��!'£C,t.�i'� � '-r.�c ° �'�° � iP�lP,� '�i�`5'S �� '" '`��1��ca+e �f � �.✓" ,
oq y C' .•k • / V f' � `r 1
4 BCIS Home Lod In User Reglstration i Hot Topics ' Submit Surcharge ` Stats & Facts ' Publications F8C Staff = BCIS Site Map !Links ;Search
Busines��'� awl-ja.
Product Approval
ProfessionalUSER: Pubilc User
Product Approval Menu > Product or Application Search > Application List > Application Detail
x.naigv FL # FL12769-R2
.. _ ..,: Application Type Revision
0
Code Version 2010
FILE CA"6PY
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and
ratified by the POC and/or the Commission If necessary.
Comments
Archived
Product Manufacturer JELD-WEN
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls, OR 97601
(800)535-3936
fbcl@jeld-wen.com
Authorized Signature Janet Gerard
fbcl@jeld-wen.com
Technical Representative JELD-WEN Corporate Customer Service
Address/Phone/Email 3737 Lakeport Blvd.
Klamath Falls, OR 97601
(800)535-3936
customerserviceagents@jeld-wen.com
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation & Management Institute
Validated By National Accreditation & Management Institute,
Referenced Standard and Year (of Standard) Standard Year
ASTM E330 2002
ASTM E331 2000
TAS202 1994
Equivalence of Product Standards
Certified By
i
7 //
http://www. floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsmFBcODh9X... 12/28/2014
-Yldrida Building Code Online
Page 2 of 3
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option A
03/07/2013
03/07/2013
03/14/2013
Summary of Products�—
FL #
Model, Number or Name
Description
12769.1
Contour Premium Steel Wood
12'-0" x 6'-8", Glazed, Steel, Wood Edge, Inswing Door
Edge Glazed Door
System with and without Sidelites
Limits of Use
Certification Agency Certificate
Approved for use In HVHZ: Yes
FL12769 R2 C CAC NI009887-R2.1)df
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
03/31/2017
Design Pressure: +55/-55
Installation Instructions
Other: Product Can Be Installed In The X, OX/XO, OXO,
FL12769 R2 II A008730 SS.Pdf
XX, OXX/XXO, and OXXO Configurations Per Installation
Verified By: Hermes F. Norero Florida PE No. 73778
Instructions. Since product does not meet water
Created by Independent Third Party: Yes
Infiltration requirement for HVHZ, it must be Installed per
Evaluation Reports
overhead requirements as identified in Sec. 4410.2.3.2
FL12769 R2 AE PER2292 SS.pdf
of the Florida RBC.
Created by Independent Third Party: Yes
12769.2
Premium Steel Wood
12'-0" x 6'-8", Glazed, Steel, Wood Edge, Inswing Door
:�::]Contour
Edge Glazed Door
jSystem with and without Sidelites
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL12769 R2 C CAC NI009887-R2.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
03/31/2017
Design Pressure: +66/-66
Installation Instructions
Other: Product Can Be Installed In The X, OX/XO, OXO,
FL12769 R2 II A008730 SS.pdf
XX, OXX/XXO, and OXXO Configurations Per Installation
Verified By: Hermes F. Norero Florida PE No. 73778
Instructions; and Must Be Installed With Surface Bolts.
Created by Independent Third Party: Yes
Since product does not meet water infiltration
Evaluation Reports i
requirement for HVHZ, it must be Installed per overhead
FL12769 R2 AE PER2292 SS.odf
requirements as identified in Sec. 4410.2.3.2 of the
Created by Independent Third Party: Yes
Florida RBC.
j 12769.3
Contour Premium Steel Wood
12'-0' x 6'-8", Glazed, Steel, Wood Edge, Outswing Door
Edge Glazed Door
System with and without Sidelites �
i
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL12769 R2 C CAC NI009887-R2.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
03/31/2017
Design Pressure: +55/-55
Installation Instructions
Other: Product Can Be Installed In The X, OX/XO, OXO,
FL12769 R2 II A008731 SS.pdf
XX, OXX/XXO, and OXXO Configurations Per Installation
Verified By: Hermes F. Norero Florida PE No. 73778
Instructions. Since product does not meet water
Created by Independent Third Party: Yes
Infiltration requirement for HVHZ, It must be Installed per
Evaluation Reports
overhead requirements as Identified in Sec. 4410.2.3.2
FL12769 R2 AE PER2293 SS.odf
of the Florida RBC.
Created by Independent Third Party: Yes
12769.4
Contour Premium Steel Wood
12'-0" x 6'-8", Glazed, Steel, Wood Edge, Outswing Door
Edge Glazed Door
System with and without Sidelites
Limits of Use
Certification Agency Certificate
Approved for use In HVHZ: Yes
FL12769 R2 C CAC N]009887-R2.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
03/31/2017
Design Pressure: +66/-66
Installation Instructions
Other: Product Can Be Installed In The X, OX/XO, OXO,
FL12769 R2 II A008731 SS.pdf
XX, OXX/XXO, and OXXO Configurations Per Installation
Verifled By: Hermes F. Norero Florida PE No. 73778
Instructions; and Must Be Installed With Surface Bolts.
Created by Independent Third Party: Yes
Since product does not meet water Infiltration
Evaluation Reports
requirement for HVHZ, it must be Installed per overhead
FL12769 R2 AE PER2293 SS.pdf
requirements as identified in Sec. 4410.2.3.2 of the
Created by Independent Third Party: Yes
Florida RBC. ti
I
—
k2769,5
Contour Premium Steel Wood
3-0 x 6-8, X, Single Out Swing Door with Vent Lite,
Edge Glazed Door
meets water Infiltration
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL12769 R2 C CAC NI011489.1)df
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
01/31/2017
Design Pressure: +55/-55
Installation Instructions
Other: Product meets water infiltration requirements for
FL12769 R2 II A009078 SS.pdf
http://www.floridabuilding. org/prlpr_app_dtl.aspx?param=wGEVXQwtDgsmFB cODh9X... 12/28/2014
Florida Building Code Online
Page 3 of 3
HVHZ Verified By: Hermes F. Norero Florida PE No. 73778
Created by Independent Third Party: Yes
Evaluation Reports
FL12769 R2 AE PER2333 SS.Ddf
Created by_Independent Third Party: Yes j
Back Next
Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.
*Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department
with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public
record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
® ,el,llxcl, 'acca
sccuritystu rurr,
http://www.floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsmFBcODh9X... 12/28/2014