Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM 405-10 - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Gerety Residence Builder Name: Street: Lot 102 Venture III Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL , Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (2280.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 2040.00 ft2 b. Frame - Wood, Exterior R=11.0 240.00 ft2 3. Number of units, if multiple family 1 , c. N/A. R= ft2 4. Number of Bedrooms 1 d. N/A R= ft2 10. Ceiling Types (1384.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1384.00 ft2 6. Conditioned floor area above grade (ft2) 1384 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(464.6 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: RoomslnBlock1 6 276.8 a. U-Factor: Sgl, U=0.29 464.60 ft2 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 35.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a. Electric Heat Pump 35.0 HSPF:9.50 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (1384.0 sqft.) Insulation Area EF: 0.990 a. Raised Floor R=30.0 888.00 ft2 b. Conservation features b. Slab -On -Grade Edge Insulation R=0.0 496.00 ft2 None c. N/A R= ft2 15. Credits CF. Pstat Glass/Floor Area: 0.336 Total Proposed Modified Loads: 28.40 PASS Total Standard Reference Loads: 36.80 I hereby certify that the plans and sp icatio s cov d by Review of the plans and 4�KE ST.gp this calculation are in compliance with the Florida ergy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. // PREPARED BY: �CF.��LZ��_ _L�tt�� ��c `s Before construction is completed DATE: i5/ZZ7/i� this building will be inspected for compliance with Section 553.908 I hereby certify that this buil g, as design , is in compliance Florida Statutes. COD with the Florida Energy C9 WE't�� OWNER/AGENT: `�'u BUILDING OFFICIAL: DATE: - DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 12/22/2014 8:50 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 _ ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 77 The lower the EnergyPerformance Index, the more efficient the home. Lot 102 Venture III, Fort Pierce, FL, 1. New construction or existing _ New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 2040.00 ft2 b. Frame - Wood, Exterior R=11.0 240.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 1 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1384.00 ft2 6. Conditioned floor area (ft2) 1384 b. N/A R= ft2 7. Windows- Description Area c. N/A R= ft z a. U-Factor: Sgl, U=0.29 464.60 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: RoomslnBlockl R ft 6 276.8 SHGC: SHG0=0.30 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 35.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 35.0 HSPF:9.50 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14. Hot water systems Cap: 1 gallons a. Raised Floor R=30.0 888.00 ft2 a. Electric EF: 0.91 b. Slab -On -Grade Edge Insulation R=0.0 496.00 ft2 c. N/A R= ft2 b. Conservation features None 15. Credits CF, Pstat I certify that this home, has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code co liant feat es. Builder Signature: Gv Date: I I -A Address of New Home: � City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software C 0 N T R ATOR COPY PROJECT Title: Gerety Residence Bedrooms: 1 Address Type: Street Address - Building Type: FLProp2010 Conditioned Area: 1384 Lot # Owner: Total Stories: 2 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: - Builder Name: Rotate Angle: 0 Street: Lot 102 Venture III Permit Office: St. Lucie County Cross Ventilation: County: St. Lucie Jurisdiction: Whole House Fan: City, State, Zip: Fort Pierce, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp / V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE_CO INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 1384 11072 SPACES Number Name Areal Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 RoomslnBlock1 1384: 11072 Yes 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio RoomslnBlockl 112 ft 0 496 ft2 -- 0 0 1 2 Raised Floor RoomslnBlockl ____ _--_ 888 ft2 30 0 0 1 ROOF Roof Gable Roof Solar Absor. SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) # Type Materials Area' Area Color 1 Hip Metal 1499 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1384 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) RoomslnBlock1 30 1384 ft2 0.11 Wood C01"NT R., AC T C P 12/22/2014 8:50 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below mt TO Wall Type Space R-Value Ft In Ft In Area R-Value Fraction Absor Grad ° 1 N Exterior Concrete Block - Int lnsi loomSInBloc 5 45 16 720 ft2 0 0.75 0 2 S Exterior Concrete Block - Int InsBloomslnBloc 5 45 16 720 ft2 0 0.75 0 3 E Exterior Concrete Block - Int lnsEloomsInBloc 5 30 16 480 ft2 0 0.75 0 4 W Exterior Concrete Block - Int InsOloomslnBloc 5 15 8 120 ft2 0 0.75 0 5 W Exterior Frame - Wood RoomslnBloc 11 30 8 240 ft2 0.23 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood RoomslnBloc None 0.460000 3 7 21 ft2 2 W Wood RoomslnBloc None 0.460000 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Tinted) Yes 0.29 0.3 N 56 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 2 N 1 Metal Single (Tinted) Yes 0.29 0.3 N 9.199999 1 It 0 in 0 ft 0 in HERS 2006 None 3 N 1 Metal Single (Tinted)' Yes 0.29 0.3 N 36 ft2 1 ft 0 in 0 It 0 in HERS 2006 None 4 N ' 1 Metal Single (Tinted) Yes 0.29 0.3 N 15 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 5 S 2 Metal Single (Tinted) Yes 0.29 0.3 N 15 ft2 1 It 0 in 0 It 0 in HERS 2006 None 6 S 2 Metal Single (Tinted) Yes 0.29 0.3 N 6.899999 1 ft 0 in 0 ft 0 in HERS 2006 None 7 S 2 Metal Single (Tinted) Yes 0.29 0.3 N 5 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 8 S 2 Metal Single (Tinted) Yes 0.29 0.3 N 15 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 9 S 2 Metal Single (Tinted) Yes 0.29 0.3 N 5 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 10 W 4 Metal Single (Tinted) Yes 0.29 0.3 N 22.5 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 11 E 3 Metal Single (Tinted) Yes 0.29 0.3 N 27 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 12 E 3 Metal Single (Tinted) Yes 0.29 0.3 N 252 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 382.8 ft2 382.8 ft2 64 ft 8 It 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 BySpaces Proposed SLA 0.000360 1306.8 71.746 134.93 0.3235 7.0821 v 12/22/2014 8:50 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 9.5 35 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 16 35 kBtu/hr 1050 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.9108 1 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS — Supply — V — Return — Air Percent HVAC # # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF Heat Cool 1 Attic 6 276.8 ft Attic 69.2 ftz DSE=0.88 RoomslnBl 0.0 cfm 0.00 % 0.00 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: May Jun x I Se ct ov Dec Venting JXXJ Jan �XjFeb IX X� Mar Apr Rj May rxi IXj r� � Sep r lX Jun Jul Aug Xug lx� Oct X� Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 12/22/2014 8:50 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: Lot 102 Venture III PERMIT #: Fort Pierce, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawispaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. CONTRACTOR COPY 12/22/2014 8:50 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5