HomeMy WebLinkAboutLETTER-ENGINEERINGFlorida's Leading Engineering Source
Environmental • Geotechnical • Construction Materials Testing • Threshold and Special Inspections • Plan Review & Code Compliance
In)— 0Siq May 5, 2015
Doyle Masonry, Inc. BY
P.O. Box 12339
Fort Pierce, Florida 34979 1 %-JL �P�9a�fi
Project: 10701 S. Ocean Drive, Lot 701
Jensen Beach, Florida
GFA Project No. 12-1489.00
Ladies and Gentlemen:
GFA verified the preparation of the subgrade soils for the structure at the above referenced
project that included subgrade and fill compaction, bottom of footing inspection and testing,
site observations, and augerlborings with hand cone penetrometers.
i
Based on our observations and test results, it is our professional opinion that the subgrade
and bottom of footings wasi prepared according to the recommendations contained in the
Federal Engineering & Testi Tg Inc. Report (Job Order Number 14-221) dated February 6; 2014
for the project. Field inspection and testing reports are submitted under separate cover.
GFA has appreciated the opportunity to assist you with this phase of your project. If you have
any questions regarding this report or need any further information, please call us.
Respectfully Submitted,
GFA INTE NAT10{9//����L�, IN
FBPE �eti�i�tL�Plder4,93Il
10
o y�
a di oleo P.E. :
Ser�o��eor�c�FEng1 ��r
FlorldaCRgglstration *Q; V.-5
� OR �
Copies: tf9h't J2) + email
521 NW Enterprise Drive • Port St. Lucie, Florida 34986 • (772) 924.3575 • (772) 924.3580 (fax) • www.teamgfa.com
OFFICES THROUGHOUT FLORIDA
� I I
Florida's Leading Engineering Source
Environmental - Geotechnical • Construction Materials Testing • Threshold and Special Inspections - Plan Review & Code Compliance
May 5, 2015
Doyle Masonry, Inc.
P.O. Box 12339
Fort Pierce, Florida 34979
Subject: Report of Soil Borings:
10701 S. Ocean Drive, Lot 701
Jensen Beach, Martin County, Florida
GFA Project No. 12-1489.00
Ladies and Gentlemen:
GFA is pleased to submit this report of soil borings for the referenced project.
Four (4) Auger Borings (AB) were performed on May 4, 2015. Hand Cone Penetrometer
(HCP) tests were conducted at one -foot intervals in the auger borings. The HCP test, in
conjunction with information about the soil type, is empirically correlated to the relative
density of subsurface soils. The HCP method was used as the investigative tool within the
borings.. The auger borings were performed in substantial accordance with ASTM Procedure
D-1452, "Practice for Soil Investigation and Sampling by Auger Borings". The samples
obtained from the borings were classified in general accordance with ASTM D 2488,
"Description and Identification of Soils" (Visual -Manual Procedure). The approximate
locations of the borings are noted on the attached boring logs. GPS coordinates obtained at
boring locations are included on the logs.
The subsurface soil conditions encountered at this site generally consist of medium dense
sand (SP) to the boring and probe termination depths. Please refer to the attached boring
logs for a detailed account of each boring.
CLOSURE
This consulting report has been prepared for the exclusive use of the current project owners
and other members of the design team for the project. This report has been prepared in
accordance with generally accepted local geotechnical engineering practices; no other
warranty is expressed or implied. The evaluation submitted in this report, is based in part
upon the data collected during a field exploration, however, the nature and extent of
variations throughout the subsurface profile may not become evident until the time of
construction. If variations then appear evident, it may be necessary to reevaluate information
and professional opinions as' provided in this report. In the event changes are made in the
nature, design, or locations of the proposed structure, the evaluation and opinions contained
521 NW Enterprise Drive - Port St. Lucie, Florida 34986 - (772) 924-3575 - (772) 924.3580 (fax) - www.teamgfa.com
OFFICES THROUGHOUT FLORIDA
1
Report of Soil Borings: May 5, 2015
10701 S. Ocean Drive, Lot 701 Page 2
Jensen Beach, Martin County, Florida
GFA Project No. 12-1489.00
in this report shall not be considered valid, unless the changes are reviewed and conclusions
modified or verified in writing by GFA International.
The analysis and recommendations submitted in this report are based on the data obtained
from the tests performed. This report does not reflect any variations, which may occur
between borings. While the, borings are representative of the subsurface conditions at their
respective locations and for their vertical reaches, local variations characteristic of the
subsurface soils of the region are anticipated and may be encountered. The delineation
between soil types shown on the soil logs is approximate and the description represents our
interpretation of the subsurface conditions at the designated boring locations on the particular
date drilled.
Any third party reliance of our geotechnical report or parts thereof is strictly prohibited without
the expressed written consent of GFA International. Any third party reliance of our
geotechnical report or parts thereof is strictly prohibited without the expressed written consent
of GFA International. The applicable SPT methodology (ASTM D-1586), CPT methodology
(ASTM D-3441), and Auger Boring methodology (ASMT D-1452) used in performing our
borings/soundings and for determining penetration resistance is specific to the sampling tools
utilized and does not reflect the ease or difficulty to advance other tools, equipment or
materials.
We appreciate the opportunity to be of service to you on this project and look forward to a
continued association. Please contact the undersigned if you have any questions or
comments, or if we may further assist you as your plans proceed. 07
Respectfully Submitted,
GFA INT4 ATIONAL, INC.
FBP�►i��e�'19�p'4930
���`QQ.•� C E N67
•.�
F F
GV
aid W. I oler, P.4*
Fjior GeotechnicalAggineer
Vla,�rd 9�966&Afio rl-' OZ-60675
Attaclirff islA eer Boring Logs (4)
Notes Related to Test Borings
Copies: Client (2)
David Alker
Project Manager
GFP
since 1988momeWomd
-
I AUGER BORING LOGS WITH HAND CONE PENETROMETER (HCP) TESTS
Client: Doyle Masonry, Inc.
Project: 10701 S. Ocean Drive, Lot 701
Jensen Beach, Florida
Elevation: Existing Grade
Project No:
Lab No:
Test Date:
Technician:
12-1489.00
3/5/2015
PM/W N
TEST LOCATION: AB — 1 Southeast Corner of Pad N27.26814° W80.207430
HCP
Depth (feet)
Description (color, texture, consistency, remarks)
Depth
Reading
0-1
Brown fine sand SP
1
80+
1 - 3%2
Gray fine sand SP
2
80+
3Y2 -4
Gray fine sand, some silt SM
3
60
4-5
Gray fine sand SP
4
40
5
40
Water table at 3 feet below ground surface
TEST LOCATION: AB — 2 West Side of Pad, 1/3 North of Southwest corner
N27.268200 W80.207570
HCP
Depth (feet)
Description (color, texture, consistency, remarks)
Depth
I Reading
0-2
Brown fine sand SP
1
80+
2-4
Gray fine sand SP
2
80+
4-5
Gray fine sand, trace root SP
3
70
4
60
5
80+
Water table at 3 feet below ground surface
TEST LOCATION: AB-3 East Side of Pad, 1/3 South of Northeast corner
HCP
Depth (feet)
Description (color, texture, consistency, remarks)
Depth
Reading
0-2
Brown fine sand, little;rock fragments SP
1
80+
2 - 3Y2
Gray fine sand SP
2
70
3%2 -4
Gray fine sand, some silt SM
3
50
4-5
Gray fine sand SP
4
50
5
50
Water table at 3 feet below ground surface
TEST LOCATION: AB-4 Northwest corner of pad
HCP
Depth (feet)
Description (color, texture, consistency, remarks)
Depth
Reading
0-2
Brown fine sand SP
1
80+
2 - 3%2
Gray fine sand SP
2
80+
3%2 -4
Gray fine sand, some silt SM
3
60
4-5
Gray fine sand SP
4
60
5
80+
Water table at 3 feet below ground surface
NOTES RELATED TO
RECORDS OF TEST BORING AND
GENERALIZED SUBSURFACE PROFILE
1. Groundwater level was encountered and recorded (if shown) following the completion of the soil test boring on
the date indicated. Fluctuations in groundwater levels are common; consult report text for a discussion.
2. The boring location was lidentified in the field by offsetting from existing reference marks and using a cloth tape
and survey wheel.
3. The borehole was backfilled to site grade following boring completion, and patched with asphalt cold patch mix
when pavement was encountered.
4. The Record of Test Boring represents our interpretation of field conditions based on engineering examination of
the soil samples.
5. The Record of Test Boring is subject to the limitations, conclusions and recommendations presented in the Report
text.
6. "Field Test Data" shown on the Record of Test Boring indicated as 11/6 refers to the Standard Penetration Test
(SPT) and means 11 hammer blows drove the sampler 6 inches. SPT uses a 140-pound hammer falling 30 inches.
7. The N-value from the SPT is the sum of the hammer blows required to drive the sampler the second and third 6-
inch increments.
8. The soil/rock strata interfaces shown on the Records of Test Boring are approximate and may vary from those
shown. The soil/rock conditions shown on the Records of Test Boring refer to conditions at the specific location
tested; soil/rock conditions may vary between test locations.
9. Relative density for sands/gravels and consistency for silts/clays are described as follows:
SPT
CPT
SANDS/GRAVELS
SPT
CPT
SILTS/CLAYS
BLOWS/FOOT
KG/CM
RELATIVE DENSITY
BLOWS/FOOT
KG/CM
CONSISTENCY
0-4
0-16
Very loose
0-1
0-3
Very soft
5-10
17-40
Loose
2-4
4-6
Soft
11-30
41-120
Medium Dense
5-8
7-12
Firm
31-50
121-200 :
Dense 1
9-15
1 13-25
Stiff
50+
over 200'
Very Dense
16-30 1
25-50
Very stiff
>30 1
>50
Hard
10. Grain size descriptions areas follows:
NAME
SIZE LIMITS
Boulder
12 Inches or more
Cobbles
Coarse Gravel
3 to 12 Inches
% to 3 Inches
Fine Gravel
No. 4 sieve to '/a inch
Coarse Sand
No. 10 to No. 4 sieve
Medium Sand
Fine Sand
Fines
No. 40 to No. 10 sieve
No. 200 to No. 40 sieve
Smaller than No. 200 sieve
11. Definitions related to adjectives used in soil/rock descriptions: