;REVIEW COMMENTS
1
i
i
Owner(s):
1 Heather M Gerety / Michael W Gerety
IJurisdiption: SAINT LUCIE COUNTY
Lot#: 102 Block:
APPLICATION INFORMATION
i
Permit Number: 1501-0388 Stories: Automatic_SprinklerSystem? No
Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
CONTRACTOR INFORMATION.
I ,
Contractor Name: James W Newman Fax Number: 772-871-9500
Business Name: Jwn Construction Inc
1 Email: Jwnconstruction@Comcast.
Business Addr: 1701 Se Carvaldo St Net
City / State / Zip: Port St
Lucie, FI 34983,
i
REVIEWS AND COMMENTS
i
Review Tyne
Status Reviewed By Date Started Date Completed Date Released
DOCUMENTS MISSING
PENDING Dawn Milone 1/28/2015
1/28/2015 Comment:
NOTICE OF COMMENCEMENT
1/28/2015 Comment:
FILLED LANDS AFFIDAVIT
Comment:
THE HOA REQUIRES THAT WRITTEN APPROVAL OR AUTHORIZATION IS ON FILE WITH THE COUNTY FOR
2/2/2015
PROPOSEDIMPROVEMENTS.
ENVIRONMENTAL REVIEW
COMPLETE Ben Balcer 2/18/2015 2/18/2015
Comment:
FRONT COUNTER REVIEW
COMPLETE Dawn Milone 1/28/2015 1/28/2015
Comment:
PE REVIEW COMMENTS (2)
INCOMPLETE William Durden 3/31/2015
Comment:
• RELOCATE FLOOD VENT TO EXTERIOR WALL IS STAIR LOCATION FROM GARAGE. AS PER 2010
2/27/2015
Comment:
2/27/2015
PLANS EXAMINER REVIEW
Comment:
ZONING REVIEW
Comment:
RESIDENTIAL BUILDING CODE SECTION R322.2.2/ 2.1 USE FLOOD VENTS MANUFACTURED FOR
CONDITIONED SPACE IN THIS ARE.
• ALL AREAS BELOW FLOOD ZONE MUST BE CONSTRUCTED WITH FLOOD RESISTANT MATERIAL. AS PER
2010 RESIDENTIAL BUILDING CODE SECTIONS R322.1.8. FRAMING MATERIAL, PLYWOOD, INSULATION,
FINISH FLOOR ATTACHMENT, ETC...
COMPLETE William Durden 2/26/2015 3/31/2015 3/31/2015
COMPLETE Jeffrey Johnson 2/212015 212/2015 2/2/2015
Planning & Development Services
Building 4 Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462.2172 Fax:(772,)462-6"3
REVIEW COMMENTS
2
2/27/2015 6 Comment: �• IN THE GARAGE LOCATION ALL APPLIANCES MUST BE PROTECTED, AS PER 2010 MECHANICAL
BUILDING CODE SECTION 303.4.
7 Comment: • PLEASE SHOW STAIRWAY LOCATION FROM GARAGE IN A CLOUD FOR REVIEW. WITH FLOOD VENTS.AS
PER 2010 RESIDENTIAL BUILDING CODE SECTION R322.2.2. USE FLOOD VENTS MANUFACTURED FOR
2/27/2015
7-2— CONDITIONED SPACE IN THIS ARE, OR REMOVE FROM DUCT LAYOUT, ENERGY AND MANUAL. SUBMIT
2 , I PRODUCT APPROVALS OR MANUFACTURERS SPECS.
2127/2015 Comment: /• NORTHWEST CORNER SHOWS AN F-4 ISOLATED PAD WITH AN AUGER PILE IN THE CENTER. SHOW
V CROSS SECTION FOR NORTHWEST CORNER FOOTING. AS PER 2010 BUILDING CODE SECTION 107.2.1
Comment: / NO SECTION DETAIL FOR F-7, 3/A-1 ON PAGE A-1. PLEASE REVIEW PLAN AND ELEVATION SYMBOLS ON
2/27/2015 V SHEETS A-1 AND CA SYMBOLS SEEM TO BE INCORRECT. SUBMIT CORRECTED SHEETS SIGNED AND
SEALED IN DUPLICATE. AS PER 2010 BUILDING CODE SECTION 107
10 Comment: • ALL AREAS BELOW FLOOD ZONE MUST BE VENTED AND CONSTRUCTED WITH FLOOD RESISTANT
2/27/2015 MATERIAL. AS PER 2010 RESIDENTIAL BUILDING CODE SECTIONS R322.1.8 AND R322.2.2. SEE STAIRWAY
FROM GARAGE, COVERED LANAI, AND RESIDENTIAL BUILDING CODE 408.2 AND 408.7 FOR THE CRAWL
r SPACE UNDER DEN/OFFICE.
2/27/2015 Comment: VI"- SHOW ATTIC ACCESS LOCATION ON PLANS AS PER 2010 BUILDING CODE SECTION 107.
`-Comment: ✓• SUBMIT WINDOW AND DOOR SCHEDULE ON PLANS AS PER 2010 BUILDING CODE SECTION 107.
2/27/2015
ZONING REVIEW COMPLETE Jeffrey Johnson 2/2/2015 212/2015 2/2/2015
Comment:
mp lww rlewo*6 .
,qtctoovo aN vw ou
jww
� a 00(� . cot) LD N ai
A p U
UI45�w
p'r FauP6
Ltv
avw
e7 W Ar-J
D M--JUAr 6 P f~
tf ifA 4taT ly
uJ ftw k no l"o w,
AW1W ; I N`10 tw
q,tr/ � A-3 ela®w) pt-'pop Fw P All A&C.
W/ ante w III,Uow 9004-bA dp!� 1c
Ur
5,46k b oath d- w G ky 0uv , of N vupop ? wy-'4
�r' A4,
aWLAfl ftw4-�-:, L-0 e +A Vq 5,ee �ccSF-�tx� 3 z2 2 . Z 17- . l
2, F4M pi-1 bd-.I 1 f / 4 r A,,M d w" wm cG F!7(oan- � Z s0 G... 4jjt t, c,,L Ffuo cl lgM,
'S1rf�i ivy.,=i-• mac v--e 44L-n 4v-pLk- 3 v.Strta } ran is. Y-t &6& w4,cpw
��ufi�P -ULk2
Planning & Development.; services
Building 8 Code Reguiation:Dlylsion
2300Mliginia Avenue
FortPieredifL. 34082 _
Phone (772)462:2172 Fax:(772)462-6443
PROPERTY INFORMATION
Address: 10701 S Ocean Dr 701
City / State / Zip: Jensen Beach, FI 34957
Parcel #: 4511-805-0102-000/7
Zoning: HIRD
APPLICATION INFORMATION
Permit Number: 1501-0388
Permit Type: BUILDING RESIDENTIAL
REVIEW COMMENTS
1
Owner(s):
Heather M Gerety / Michael W Gerety
i
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 102
Stories:
FLOORS)
Block:
Automatic Sprinkler System? No
CONTRACTOR INFORMATION ,Z (r
j7%
Contractor Name: James W Newman •7e J Fax Number: 772-871-9500
Business Name: Jwn Construction Inc �7 ZSA
Onf Email: Jwnconstruction@Comcast.
Business Addr: 1701 Se Carvaldo St � S Net
City / State / Zip: Port St Lucie, FI 34983
i
i
REVIEWS AND COMMENTS
Review TVDB Status Reviewed By Date Started Date Completed Date Released
DOCUMENTS MISSING PENDING Dawn Milone 1/28/2016
1/28/2015 Comment: NOTICE OF COMMENCEMENT
1/28/2015 Comment: FILLED LANDS AFFIDAVIT
2/2/2015 Comment: THE HOA REQUIRES THAT WRITTEN APPROVAL OR AUTHORIZATION IS ON FILE WITH THE COUNTY FOR
PROPOSEDIMPROVEMENTS. ,
ENVIRONMENTAL REVIEW COMPLETE Ben Balcer 211812015 2/18/2016
Comment:
FRONT COUNTER REVIEW COMPLETE LawnMilone 1/28/2015 1/28/2015
Comment:
PLANS EXAMINER REVIEW INCOMPLETE 2/26/2015
Comment: PLANS SHOWSTALLED ON THE SECOND FLOOR EXTERIOR WALL. THE
2/27/2015 / Comment
SURVEY SHOWS THE MECHANICAL A/C UNIT IN STALLED IN THE REAR OF THE HOME WITHIN
THE 5 FOOT SETBACK. SUBMIT REVISED SIGNED AND SEALED BOUNDARY SURVEY IN DUPLICATE.
Comment: ITEMIZE ALL CODES PERTAINING TO THIS PROJECT, SEE SHEET C-1 CODE USE BOX. AS PER 2010
2/27/2015 2
BUILDING CODE SECTION 101.4.
2/27/2015 3 Comment: _ / • SUBMIT PRODUCT REVIEW AFFIDAVIT ALL LINES COMPLETELY FILLED OUT, SIGNED, AND SEALED BY
V THE DESIGN PROFESSIONAL 2010 BUILDING CODE SECTION 107.
CommentV - COMPONENTS AND CLADDING DESIGN PRESSURES THAT WERE SUBMITTED SEEMS LOW, BASED ON
2/27/2015 THE 10SQFT @ 25FT MRH, WITH AN EXPOSURE D MULTIPLIER. AS PER SECTION R301.2 (2) AND R301.2 (3)
OF THE 2010 RESIDENTIAL BUILDING CODE.
Comment: - SUBMIT CERTIFIED GEOTECHNICAL REPORT WITH PILE AND FOUNDATION RECOMMENDATIONS
2/27/2015 <7 ORIGINAL DOCUMENTS SIGNED AND SEALED. SEE PILING NOTES ON SHEET A-1. SUBMIT SOIL TEST
0 REPORT AS PER NOTE ON THE CERTIFICATION FOR DESIGN LOAD COMPLIANCE. AS PER 2010 BUILDING
CODE SECTION 1803.
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462-6443
PROPERTY INFORMATION
Address: 10701 S Ocean Dr 701
City / State / Zip: Jensen Beach, FI 34957
Parcel #: 4511-805-0102-000/7
REVIEW COMMENTS
Page 1
Owner(s):
Heather M Gerety / Michael W Gerety
Jurisdiction: SAINT LUCIE COUNTY
Zoning: HIRD Lot#: 102
APPLICATION INFORMATION
Permit Number: 1501-0388 Stories:
Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
CONTRACTOR INFORMATION
Contractor Name: James W Newman
Business Name:
Jwn Construction Inc
Business Addr:
1701 Se Carvaldo St
City / State / Zip:
Port St Lucie, FI 34983
REVIEWS AND COMMENTS
Review Type
DOCUMENTS MISSING
1/28/2015 Comment:
1/28/2015 Comment:
2/2/2015 Comment:
ENVIRONMENTAL REVIEW
Comment:
FRONT COUNTER REVIEW
Comment:
PLANS EXAMINER REVIEW
Comment:
2/27/2015
2/27/2015 Comment:
2/27/2015 Comment:
Comment:
2/27/2015
Comment:
2/27/2015
Block:
Automatic Sprinkler System? No
Fax Number: 772-871-9500
Email: Jwnconstruction@Comcast.
Net
Status Reviewed ev Date Started Date Completed Date Released
PENDING Dawn Milone 1/28/2015
NOTICE OF COMMENCEMENT
FILLED LANDS AFFIDAVIT
THE HOA REQUIRES THAT WRITTEN APPROVAL OR AUTHORIZATION IS ON FILE WITH THE COUNTY FOR
PROPOSEDIMPROVEMENTS.
COMPLETE Ben Balcer 2/18/2015 2/18/2015
COMPLETE Dawn Milone
INCOMPLETE William burden 2/26/2015
1/28/2015 1/28/2015
- PLANS SHOW MECHANICAL A/C UNIT INSTALLED ON THE SECOND FLOOR EXTERIOR WALL. THE
BOUNDARY SURVEY SHOWS THE MECHANICAL A/C UNIT IN STALLED IN THE REAR OF THE HOME WITHIN
THE 5 FOOT SETBACK. SUBMIT REVISED SIGNED AND SEALED BOUNDARY SURVEY IN DUPLICATE.
• ITEMIZE ALL CODES PERTAINING TO THIS PROJECT, SEE SHEET C-1 CODE USE BOX. AS PER 2010
BUILDING CODE SECTION 101.4.
- SUBMIT PRODUCT REVIEW AFFIDAVIT ALL LINES COMPLETELY FILLED OUT, SIGNED, AND SEALED BY
THE DESIGN PROFESSIONAL 2010 BUILDING CODE SECTION 107.
• COMPONENTS AND CLADDING DESIGN PRESSURES THAT WERE SUBMITTED SEEMS LOW, BASED ON
THE 10SQFT @ 25FT MRH, WITH AN EXPOSURE D MULTIPLIER. AS PER SECTION R301.2 (2) AND R301.2 (3)
OF THE 2010 RESIDENTIAL BUILDING CODE.
• SUBMIT CERTIFIED GEOTECHNICAL REPORT WITH PILE AND FOUNDATION RECOMMENDATIONS
ORIGINAL DOCUMENTS SIGNED AND SEALED. SEE PILING NOTES ON SHEET A-1. SUBMIT SOIL TEST
REPORT AS PER NOTE ON THE CERTIFICATION FOR DESIGN LOAD COMPLIANCE. AS PER 2010 BUILDING
CODE SECTION 1803.
R
rwl2 AM41
-ate•
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462-6443
i
REVIEW COMMENTS
Page 2
Comment:
• IN THE GARAGE LOCATION ALL APPLIANCES MUST BE PROTECTED. AS PER 2010 MECHANICAL BUILDING
2/27/2015
CODE SECTION 303.4.
Comment:
• PLEASE SHOW STAIRWAY LOCATION FROM GARAGE IN A CLOUD FOR REVIEW. WITH FLOOD VENTS.AS
PER 2010 RESIDENTIAL BUILDING CODE SECTION R322.2.2. USE FLOOD VENTS MANUFACTURED FOR
2/27/2015
CONDITIONED SPACE IN THIS ARE, OR REMOVE FROM DUCT LAYOUT, ENERGY AND MANUAL. SUBMIT
PRODUCT APPROVALS OR MANUFACTURERS SPECS.
Comment:
• NORTHWEST CORNER SHOWS AN F-4 ISOLATED PAD WITH AN AUGER PILE IN THE CENTER. SHOW
2/27/2015
CROSS SECTION FOR NORTHWEST CORNER FOOTING. AS PER 2010 BUILDING CODE SECTION 107.2.1
i
Comment:
• NO SECTION DETAIL FOR F-7, 3/A-1 ON PAGE A-1. PLEASE REVIEW PLAN AND ELEVATION SYMBOLS ON
2/27/2015
SHEETS A-1 AND C-1 SYMBOLS SEEM TO BE INCORRECT. SUBMIT CORRECTED SHEETS SIGNED AND
SEALED IN DUPLICATE. AS PER 2010 BUILDING CODE SECTION 107
Comment:
• ALL AREAS BELOW FLOOD ZONE MUST BE VENTED AND CONSTRUCTED WITH FLOOD RESISTANT
MATERIAL. AS PER 2010 RESIDENTIAL BUILDING CODE SECTIONS R322.1.8 AND R322.2.2. SEE STAIRWAY
2l27/2015
FROM GARAGE, COVERED LANAI„ AND RESIDENTIAL BUILDING CODE 408.2 AND 408.7 FOR THE CRAWL
SPACE UNDER DEN/OFFICE.
2/27/2015 Comment:
• SHOW ATTIC ACCESS LOCATION ON PLANS AS PER 2010 BUILDING CODE SECTION 107.
Comment:
• SUBMIT WINDOW AND DOOR SCHEDULE ON PLANS AS PER 2010 BUILDING CODE SECTION 107.
2/27/2015
I
ZONING REVIEW
COMPLETE Jeffrey Johison 2/2/2015 2/2/2015 2/2/2015
Comment:
Planning& Development Services REVIEW COMMENTS FOR OWNER
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462.6443
Page 1 of 2
February 27, 2015
MICHAEL W GERETY
10701 S Ocean Dr #701
Jensen Beach, FL 34957
RE: Building Permit Number 1501-0388
As of today's date your Contractor is being notified along with yourself that the referenced buiding permit has some issues listed
in the comments below.
We have asked that these issues be dealt with as quickly as possible so that we are able to continue to process this permit in a
timely manner.
This information is being shared with you so you are aware of the status of your permit.
PROPERTY INFORMATION
10701 S OCEAN DR 701
JENSEN BEACH, FL 34957
APPLICATION INFORMATION
Permit Number: 1501-0388
Permit Type: BUILDING RESIDENTIAL (SFR UP TO
2 FLOORS)
REVIEWS AND COMMENTS
Review Tvpe
Status
FRONT COUNTER REVIEW
COMPLETE
Comment:
DOCUMENTS MISSING
PENDING
1/28/2015 11:55:33 AM
Comment:
1/28/2015 11:55:33 AM
Comment:
2/2/2015 8:46:48 AM
Comment:
ZONING REVIEW COMPLETE
Comment:
CONTRACTOR INFORMATION
18,415
JWN CONSTRUCTION INC
JAMES W NEWMAN
1701 SE CARVALDO ST
Pb,RT ST LUCIE, FL 34983
Stories: 1
Reviewed By Date Started Date Completed Date Released
DAWN MILONE 1/28/2015
DAWN MILONE 1/28/2015 1/28/2015
NOTICE OF COMMENCEMENT
FILLED LANDS AFFIDAVIT
THE HOA REQUIRES THAT WRITTEN APPROVAL OR AUTHORIZATION IS ON FILE WITH THE
COUNTY FOR PROPOSED IMPROVEMENTS.
JEFFREY JOHNSON 2/2/2015 2/2/2015 1/28/2015
Friday, February 27, 2015 2:30 PM
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462-6443
PLANS EXAMINER REVIEW INCOMPLETE WILLIAM DURDEN
REVIEW COMMENTS FOR OWNER
2/26/2015
Page 2 of 2
2/2/2015
2/27/2015 2:21:02 PM Comment:
- PLANS SHOW MECHANICAL A/C UNIT INSTALLED ON THE SECOND FLOOR EXTERIOR WALL.
THE BOUNDARY SURVEY SHOWS THE MECHANICAL A/C UNIT IN STALLED IN THE REAR OF THE
HOME WITHIN THE 5 FOOT SETBACK. SUBMIT REVISED SIGNED AND SEALED BOUNDARY
SURVEY IN DUPLICATE.
2/27/2015 2:21:02 PM Comment:
- ITEMIZE ALL CODES PERTAINING TO THIS PROJECT, SEE SHEET C-1 CODE USE BOX. AS PER
2010 BUILDING CODE SECTION 101.4.
2/27/2015 2:21:02 PM Comment:
- SUBMIT PRODUCT REVIEW AFFIDAVIT ALL LINES COMPLETELY FILLED OUT, SIGNED, AND
SEALED BY THE DESIGN PROFESSIONAL 2010 BUILDING CODE SECTION 107.
2/27/2015 2:21:02 PM Comment:
- COMPONENTS AND CLADDING DESIGN PRESSURES THAT WERE SUBMITTED SEEMS LOW,
BASED ON THE 10SQFT @ 25FT MRH, WITH AN EXPOSURE D MULTIPLIER. AS PER SECTION
R301.2 (2) AND R301.2 (3) OF THE 2010 RESIDENTIAL BUILDING CODE.
2/27/2015 2:21:03 PM Comment:
- SUBMIT CERTIFIED GEOTECHNICAL REPORT WITH PILE AND FOUNDATION
RECOMMENDATIONS ORIGINAL DOCUMENTS SIGNED AND SEALED. SEE PILING NOTES ON
SHEET A-1. SUBMIT SOIL TEST REPORT AS PER NOTE ON THE CERTIFICATION FOR DESIGN
LOAD COMPLIANCE. AS PER 2010 BUILDING CODE SECTION 1803.
2/27/2015 2:21:03 PM Comment:
- IN THE GARAGE LOCATION ALL APPLIANCES MUST BE PROTECTED. AS PER 2010 MECHANICAL
BUILDING CODE SECTIO003.4.
2/27/2015 2:21:03 PM Comment:
- PLEASE SHOW STAIRWAY LOCATION FROM GARAGE IN A CLOUD FOR REVIEW. WITH FLOOD
VENTS.AS PER 2010 RESIDENTIAL BUILDING CODE SECTION R322.2.2. USE FLOOD VENTS
MANUFACTURED FOR CONDITIONED SPACE IN THIS ARE, OR REMOVE FROM DUCT LAYOUT,
ENERGY AND MANUAL. SUBMIT PRODUCT APPROVALS OR MANUFACTURERS SPECS.
2/27/2015 2:21:03 PM Comment:
- NORTHWEST CORNER SHOWS AN F-4 ISOLATED PAD WITH AN AUGER PILE IN THE CENTER.
SHOW CROSS SECTION FOR NORTHWEST CORNER FOOTING. AS PER 2010 BUILDING CODE
SECTION 107.2.1
2/27/2015 2:21:03 PM Comment:
- NO SECTION DETAIL FOR F-7, 3/A-1 ON PAGE A-1. PLEASE REVIEW PLAN AND ELEVATION
SYMBOLS ON SHEETS A-1 AND C-1 SYMBOLS SEEM TO BE INCORRECT. SUBMIT CORRECTED
SHEETS SIGNED AND SEALED IN DUPLICATE. AS PER 2010 BUILDING CODE SECTION 107
2/27/2015 2:21:03 PM Comment:
- ALL AREAS BELOW FLOOD ZONE MUST BE VENTED AND CONSTRUCTED WITH FLOOD
RESISTANT MATERIAL. AS PER 2010 RESIDENTIAL BUILDING CODE SECTIONS R322.1.8 AND
R322.2.2. SEE STAIRWAY FROM GARAGE, COVERED LANAI, AND RESIDENTIAL BUILDING CODE
408.2 AND 408.7 FOR THE CRAWL SPACE UNDER DEN/OFFICE.
2/27/2015 2:21:39 PM Comment:
- SHOW ATTIC ACCESS LOCATION ON PLANS AS PER 2010 BUILDING CODE SECTION 107.
2/27/2015 2:21:39 PM Comment:
- SUBMIT WINDOW AND DOOR SCHEDULE ON PLANS AS PER 2010 BUILDING CODE SECTION
107.
ENVIRONMENTAL REVIEW COMPLETE
Comment:
BEN BALCER
2/18/2015 1 /28/2015
Friday, February 27, 2015 2:30 PM
5�"�u"�, Cates
Planning& Development Services REVIEW COMMENTS FOR CONTRACTOR
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462-6443
Page 1 of 2
February 27, 2015
18415
JWN CONSTRUCTION INC
JAMES W NEWMAN
1701 SE CARVALDO ST
PORT ST LUCIE, FL 34983
RE: Building Permit Number 1501-0388
As of today's date the owner listed on your application is being notified along with yourself that the referenced buiding permit
has some issues listed in the comments below.
Please address these issues as quickly as possible so that we are able to continue to process this permit in a timely manner. If
you have any questions regarding the comments below, please call) our office.
PROPERTY INFORMATION OWNER INFORMATION
10701 S OCEAN DR 701 MICHAEL W GERETY
JENSEN BEACH, FL 34957 10701 S Ocean Dr #701
Jensen Beach, FL 34957
APPLICATION INFORMATION
Permit Number: 1501-0388 Stories: 1
Permit Type: BUILDING RESIDENTIAL (SFR UP TO
2 FLOORS)
REVIEWS AND COMMENTS
Review Type
Status
Reviewed By Date Started Date Completed Date Released
FRONT COUNTER REVIEW
COMPLETE
DAWN MILONE 1/28/2015
Comment:
DOCUMENTS MISSING
PENDING
DAWN MILONE 1/28/2015 1/28/2015
1/28/2015 11:55:33 AM
Comment:
NOTICE OF COMMENCEMENT
1/28/2015 11:55:33 AM
Comment:
FILLED LANDS AFFIDAVIT
2/2/2015 8:46:48 AM
Comment:
THE HOA REQUIRES THAT WRITTEN APPROVAL OR AUTHORIZATION IS ON FILE WITH THE
COUNTY FOR PROPOSED IMPROVEMENTS.
ZONING REVIEW
COMPLETE
JEFFREYJOHNSON 2/2/2015 2/2/2015 1/28/2015
Comment:
Friday, February 27, 2015 2:31 PM
v r+
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462-6443
PLANS EXAMINER REVIEW INCOMPLETE WILLIAM DURDEN
REVIEW COMMENTS FOR CONTRACTOR
2/26/2015
Page 2 of 2
2/2/2015
2/27/2015 2:21:02 PM Comment:
• PLANS SHOW MECHANICAL A/C UNIT INSTALLED ON THE SECOND FLOOR EXTERIOR WALL.
THE BOUNDARY SURVEY SHOWS THE MECHANICAL A/C UNIT IN STALLED IN THE REAR OF THE
HOME WITHIN THE 5 FOOT SETBACK. SUBMIT REVISED SIGNED AND SEALED BOUNDARY
SURVEY IN DUPLICATE.
2/27/2015 2:21:02 PM Comment:
• ITEMIZE ALL CODES PERTAINING TO THIS PROJECT, SEE SHEET C-1 CODE USE BOX. AS PER
2010 BUILDING CODE SECTION 101.4.
2/27/2015 2:21:02 PM Comment:
- SUBMIT PRODUCT REVIEW AFFIDAVIT ALL LINES COMPLETELY FILLED OUT, SIGNED, AND
SEALED BY THE DESIGN PROFESSIONAL 2010 BUILDING CODE SECTION 107.
2/27/2015 2:21:02 PM Comment:
- COMPONENTS AND CLADDING DESIGN PRESSURES THAT WERE SUBMITTED SEEMS LOW,
BASED ON THE 10SQFT @ 25FT MRH, WITH AN EXPOSURE D MULTIPLIER. AS PER SECTION
R301.2 (2) AND R301.2 (3) OF THE 2010 RESIDENTIAL BUILDING CODE.
2/27/2015 2:21:03 PM Comment:
• SUBMIT CERTIFIED GEOTECHNICAL REPORT WITH PILE AND FOUNDATION
RECOMMENDATIONS ORIGINAL DOCUMENTS SIGNED AND SEALED. SEE PILING NOTES ON
SHEET A-1. SUBMIT SOIL TEST REPORT AS PER NOTE ON THE CERTIFICATION FOR DESIGN
LOAD COMPLIANCE. AS PER 2010 BUILDING CODE SECTION 1803.
2/27/2015 2:21:03 PM Comment:
• IN THE GARAGE LOCATION ALL APPLIANCES MUST BE PROTECTED. AS PER 2010 MECHANICAL
BUILDING CODE SECTION 303.4.
2/27/2015 2:21:03 PM Comment:
• PLEASE SHOW STAIRWAY LOCATION FROM GARAGE IN A CLOUD FOR REVIEW. WITH FLOOD
VENTS.AS PER 2010 RESIDENTIAL BUILDING CODE SECTION R322.2.2. USE FLOOD VENTS
MANUFACTURED FOR CONDITIONED SPACE IN THIS ARE, OR REMOVE FROM DUCT LAYOUT,
ENERGY AND MANUAL. SUBMIT PRODUCT APPROVALS OR MANUFACTURERS SPECS.
2/27/2015 2:21:03 PM Comment:
- NORTHWEST CORNER SHOWS AN F-4 ISOLATED PAD WITH AN AUGER PILE IN THE CENTER.
SHOW CROSS SECTION FOR NORTHWEST CORNER FOOTING. AS PER 2010 BUILDING CODE
SECTION 107.2.1
2/27/2015 2:21:03 PM Comment:
- NO SECTION DETAIL FOR F-7, 3/A-1 ON PAGE A-1. PLEASE REVIEW PLAN AND ELEVATION
SYMBOLS ON SHEETS A-1 AND C-1 SYMBOLS SEEM TO BE INCORRECT. SUBMIT CORRECTED
SHEETS SIGNED AND SEALED IN DUPLICATE. AS PER 2010 BUILDING CODE SECTION 107
2/27/2015 2:21:03 PM Comment:
- ALL AREAS BELOW FLOOD ZONE MUST BE VENTED AND CONSTRUCTED WITH FLOOD
RESISTANT MATERIAL. AS PER 2010 RESIDENTIAL BUILDING CODE SECTIONS R322.1.8 AND
R322.2.2. SEE STAIRWAY FROM GARAGE, COVERED LANAI, AND RESIDENTIAL BUILDING CODE
408.2 AND 408.7 FOR THE CRAWL SPACE UNDER DEN/OFFICE.
2/27/2015 2:21:39 PM Comment:
- SHOW ATTIC ACCESS LOCATION ON PLANS AS PER 2010 BUILDING CODE SECTION 107.
2/27/2015 2:21:39 PM Comment:
- SUBMIT WINDOW AND DOOR SCHEDULE ON PLANS AS PER 2010 BUILDING CODE SECTION
107.
ENVIRONMENTAL REVIEW COMPLETE
Comment:
BEN BALCER
2/18/2015 1 /28/2015
Friday, February 27, 2015 2:31 PM
I
• PLANS SHOW MECHANICAL A/C UNIT INSTALLED ON THE SECOND FLOOR EXTERIOR WALL. THE
BOUNDARY SURVEY SHOWS THE MECHANICAL A/C UNIT IN STALLED IN THE REAR OF THE HOME
WITHIN THE 5 FOOT SETBACK. SUBMIT REVISED SIGNED AND SEALED BOUNDARY SURVEY IN
DUPLICATE.
• ITEMIZE ALL CODES PERTAINING TO THIS PROJECT, SEE SHEET C-1 CODE USE BOX. AS PER 2010
BUILDING CODE SECTION 101.4.
• SUBMIT PRODUCT REVIEW AFFIDAVIT ALL LINES COMPLETELY FILLED OUT, SIGNED, AND SEALED
BY THE DESIGN PROFESSIONAL 2010 BUILDING CODE SECTION 107.
• COMPONENTS AND CLADDING DESIGN PRESSURES THAT WERE SUBMITTED SEEMS LOW, BASED
ON THE 10SQFT @ 25FT MRH, WITH AN EXPOSURE D MULTIPLIER. AS PER SECTION R301.2 (2)
AND R301.2 (3) OF THE 2010 RESIDENTIAL BUILDING CODE.
• SUBMIT CERTIFIED GEOTECHNICAL REPORT WITH PILE AND FOUNDATION RECOMMENDATIONS
ORIGINAL DOCUMENTS SIGNED AND SEALED. SEE PILING NOTES ON SHEET A-1. SUBMIT SOIL
TEST REPORT AS PER NOTE ON THE CERTIFICATION FOR DESIGN LOAD COMPLIANCE. AS PER
2010 BUILDING CODE SECTION 1803.
• IN THE GARAGE LOCATION ALL APPLIANCES MUST BE PROTECTED. AS PER 2010 MECHANICAL
BUILDING CODE SECTION 303.4.
• PLEASE SHOW STAIRWAY LOCATION FROM GARAGE IN A CLOUD FOR REVIEW. WITH FLOOD
VENTS.AS PER 2010 RESIDENTIAL BUILDING CODE SECTION R322.2.2. USE FLOOD VENTS
MANUFACTURED FOR CONDITIONED SPACE IN THIS ARE, OR REMOVE FROM DUCT LAYOUT,
ENERGY AND MANUAL. SUBMIT PRODUCT APPROVALS OR MANUFACTURERS SPECS.
• NORTHWEST CORNER SHOWS AN F-4 ISOLATED PAD WITH AN AUGER PILE IN THE CENTER.
SHOW CROSS SECTION FOR NORTHWEST CORNER FOOTING. AS PER 2010 BUILDING CODE
SECTION 107.2.1
• NO SECTION DETAIL FOR F-7, 3/A-1ON PAGE A-1. PLEASE REVIEW PLAN AND ELEVATION
SYMBOLS ON SHEETS A-1 AND C-1 SYMBOLS SEEM TO BE INCORRECT. SUBMIT CORRECTED
SHEETS SIGNED AND SEALED IN DUPLICATE. AS PER 2010 BUILDING CODE SECTION 107
• ALL AREAS BELOW FLOOD ZONE MUST BE VENTED AND CONSTRUCTED WITH FLOOD RESISTANT
MATERIAL. AS PER 2010 RESIDENTIAL BUILDING CODE SECTIONS R322.1.8 AND R322.2.2. SEE
STAIRWAY FROM GARAGE, COVERED LANAI, AND RESIDENTIAL BUILDING CODE 408.2 AND
408.7 FOR THE CRAWL SPACE UNDER DEN/OFFICE.
• SHOW ATTIC ACCESS LOCATION ON PLANS AS PER 2010 BUILDING CODE SECTION 107.
• SUBMIT WINDOW AND DOOR SCHEDULE ON PLANS AS PER 2010 BUILDING CODE SECTION 107.
Planning.& Development Services
Building &.Code Regulation Division
2300 Virginia Avenue.
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462-6443
PROPERTY INFORMATION
Address: 10701 S Ocean Dr 701
City / State / Zip: Jensen Beach, FI 34957
Parcel #: 4511-805-0102-000/7
REVIEW COMMEN"A E
C
APR 10 2015
Public Works Page 1
1musie eon,el- —
Owner(s):
Heather M Gerety / Michael W Gerety
Jurisdiction: SAINT LUCIE COUNTY
Zoning: HIRD Lot#: 102
APPLICATION INFORMATION
Permit Number: 1501-0388 Stories:
Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
CONTRACTOR INFORMATION
Contractor Name: James W Newman
Business Name:
Jwn Construction Inc
Business Addr:
1701 Se Carvaldo St
City / State / Zip:
Port St Lucie, FI 34983
REVIEWS AND COMMENTS
Review Tvoe
DOCUMENTS MISSING
1/28/2015 Comment:
1/28/2015 Comment:
2/2/2015 Comment:
ENVIRONMENTAL REVIEW
Comment:
FRONT COUNTER REVIEW
Comment:
PE REVIEW COMMENTS (2)
Comment:
2/27/2015
Comment:
2/27/2015
PLANS EXAMINER REVIEW
Comment:
ZONING REVIEW
Comment:
Block:
Automatic Sprinkler System? No
Fax Number: 772-871-9500
Email: Jwnconstruction@Comcast.
Net
Status Reviewed By Date Started Date Completed Date Released
PENDING Dawn Milone 1/28/2015
NOTICE OF COMMENCEMENT
FILLED LANDS AFFIDAVIT
THE HOA REQUIRES THAT WRITTEN APPROVAL OR AUTHORIZATION IS ON FILE WITH THE COUNTY FOR
PROPOSEDIMPROVEMENTS.
COMPLETE Ben Balcer 2/18/2015 2/18/2015
COMPLETE Daw. Milone 1/28/2015 1/28/2015
1,
INCOMPLETE William Du 3/31/2015
• RELOCATE FLOG ENT TO ERIOR WALL IS STAIR LOCATION FROM GARAGE. AS PER 2010
RESIDENTIAL BUILDING CODE SECTION R322.2.2/ 2.1 USE FLOOD VENTS MANUFACTURED FOR
CONDITIONED SPACE IN THIS ARE.
• ALL AREAS BELOW FLOOD ZONE MUST BE CONSTRUCTED WITH FLOOD RESISTANT MATERIAL. AS PER
2010 RESIDENTIAL BUILDING CODE SECTIONS R322.1.8. FRAMING MATERIAL, PLYWOOD, INSULATION,
FINISH FLOOR ATTACHMENT, ETC...
COMPLETE William Durden 2/26/2015 3/31/2015 3/31/2015
COMPLETE Jeffrey Johnson 2/2/2015 212/2015 212/2015