HomeMy WebLinkAbout96110404LU
SY7' LY.7N
ST. L1
P.O. BOX 3030
FT. PIERCE FL. 34948-3030
2400 RHODE ISLAND AVE
FT. PIERCE, FL. 34950
A
FIRE DISTRICT
TELEPHONE (561)462-2325
FAX NO. (561)-462-2325
JURISDICTION: St. Lucie County F.P.B. NO: 6608
PROJECT NAME: Circle H. Citrus BUILDING DEPT: 961103W IPV�t.P
BUILDING LOCATION: 3500 Shinn Rd. NUMBER OF STORIES: Two
CONTRACTOR: Paul Jacquin PHONE No: 561-465-2475
ARCHITECT / ENGINEER: J.H. White PHONE No: 561-489-3782
BUILDING OWNER: Circle H. Citrus REVIEW DATE: 12-11-96
OCCUPANCY CLASS: Business AUTOMATIC SP'KLRS: No
GROSS SQ FT: 2774 sq ft NET SQ FT. 2774
OCCUPANCY LOAD: 27 BASED ON: 100 sq ft p.p.
CONSTRUCTION: NFPA # 220: ( III ) - (200) SBCCI: ( V ) - (Un) Protected
i
New Construction: X Shell Only enant Improvement: Renovation:
' Addition: A/S System: Contractor:
Fire Alarm: Contractor: I Storage tank:
All revisions must be in compliance before the final inspection.
The Fire Marshal requires 24 hr. notice on all inspections.
The Building Department schedules all inspections by the Fire Marshal.
Required revisions
1. The entire stairway including the bottom of the stair riser shall be
enclosed by construction having a one hour fire resistance rating.
2. The door located at the top of the stairway shall be a Class 13,1-hr rated
door and Jamb assembly equipped with a self closing device.
3. The storage area underneath the stairway shall have a Class C -3/4 hr.
rated door and jamb assembly.
4. Handrails are required on both sides of the stairs.
I
5. The exit sign is not required at the bottom of the stairs.
� I
6. Provide Illuminated exit signs as indicated in red.
I
7. Provide a 2A -1013C rated fire extinguisher for each story.
CIRCLE H. CITRUS
# 6608
8. Though not a requirement
as indicated in red.
Reviewed by:
suggest emergency lighting be provided
Date: 1 z -
John K. Hayd