Loading...
HomeMy WebLinkAboutREVIEW-COMMENTSPlanning & Development Services a Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 i, Phone:(772)462-2172 Fax:(772)462-644� ���P't ,�PQflrll® PROPERTY INFORMATION Address: 5348 Oakland Lake Cir City / State / Zip: Fort Pierce, FI 34951 Parcel M 1311-800-0025-000/5 Zoning: PUD REVIEW COMMENTS Ddc RECEIVED S JUL 69 2018 Permitting Department _ ..:,nSe. Page 1 _C Estates Jurisdiction: SAINT LUCIE COUNTY Lot#: 12 APPLICATION INFORMATION Permit Number: 1806-0497 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Robert P li Smithwick Business Name: Nvr Inc Business Addr: 1450 Centrepark Blvd Ste 340 City / State / Zip: West Palm Beach, FI 33401 REVIEWS AND COMMENTS Review Tvae Status ADDRESSING ASSIGNMENT COMPLETE Comment: Lori Block: Automatic Sprinkler System? No Fax Number: 561-720-1341 Date Started Email: Rsmithwi@Nvrinc.Com Date Completed Date Released 6/21/2018 6/21/2018 DOCUMENTS MISSING PENDING 6/19/2018 Comment: NEEDS NOC 6/19/2018 Comment: SENT CUSTOMER TO ERD WITH VEG PERMIT. VEG PERMIT IN DRAWER UNDER "N" NVR INC. FEE LOADED ENVIRONMENTAL REVIEW COMPLETE Lynn Swartzel 6/20/2018 6/20/2018 6/20/2018 i Comment: FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 6/19/2018 6/19/2018 6/19/2018 Comment: i PLANS EXAMINER REVIEW INCOMPLETE William Durden 6/28/2018 Comment: PAGE 4 OF EIGHT OF THE SUBMITTED DRAWINGS NOTE NUMBER ONE, SPECIFIES PRIOR TO DRYWALL INSULATION ON ALL FRAMING MEMBERS 2 FOOT FROM THE FINISH FLOOR WILL BE SPRAYED AND 6/28/2018 TREATED WITH BORATE TERMITE TREATED SPRAYED. THE REST OF THE PLANS SPECIFY CLEAN COMPACTED TERMITE TREATED FILL. PLEASE CORRECT DRAWINGS TO SHOW ACTUAL CONDITIONS TO BE INSTALLED. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. 6/28/2018 Comment: i PLANS SHOW LAP SIDING AND STUCCO DETAILS. PLEASE REMOVE FROM THE PLANS ANY INFORMATION NOT PERTAINING TO THE NEW STRUCTURE. SEE SECTION 107.2.4 OF THE 2017 FLORIDA BUILDING CODE. Comment: PLANS SHOW A BALCONY DETAIL NO BALCONY IS SHOWN ON THE ELEVATION PAGES OR THE FLOOR 6/28/2018 PLAN. PLEASE REMOVE FROMTHE PLANS ANY INFORMATION NOT PERTAINING TO THE NEW STRUCTURE. SEE SECTION 107.2.4 OF THE 2017 FLORIDA BUILDING CODE. Comment: - PRODUCT APPROVAL/NOA NUMBER 14039 - R-2 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL 6/28/2018 NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. i Planning& Development Services REVIEW COMMENTS Building & Code Regulation. Division, 2300 Virginia Avenue Fort Pierce, FL: 34982 Phone:(772)462.2172 Fax:(772)462-6443 Page 2 Comment: - PRODUCT APPROVAUNOA NUMBER 14039 - R-2 IS THE REVISION NUMBER FOR THE PRODUCT. PLEASE 6/28/2018 CORRECT PRODUCT APPROVAL NUMBER ON PLANS TO REFLECT THE SITE SPECIFIC PRODUCT APPROVAL NUMBER. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: • PRODUCT APPROVA UI NOA NUMBER 5891 - R-5 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL 6/28/2018 NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. I Comment: • PRODUCT APPROVA NOA NUMBER 5891 - R-5 IS THE REVISION NUMBER FOR THE PRODUCT. PLEASE 6/28/2018 CORRECT PRODUCT APPROVAL NUMBER ON PLANS TO REFLECT THE SITE SPECIFIC PRODUCT APPROVAL NUMBER. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: - PRODUCT APPROVA! I NOA NUMBER 5219.3 - R-3 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL 6/28/2018 NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: - PRODUCT APPROVA I NOA NUMBER 15216 - R-2 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL 6/28/2018 NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: - PRODUCT APPROVA 1 NOA NUMBER 15216 R-2 IS THE REVISION NUMBER FOR THE PRODUCT. 6/28/2018 - PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS TO REFLECT THE SITE SPECIFIC PRODUCT APPROVAL NUMBER. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. 6/28/2018 Comment: - PRODUCT APPROVAUNOA NUMBER 18355 - R-3 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: • PRODUCT APPROVAUNOA NUMBER 18355 - R-3 IS THE REVISION NUMBER FOR THE PRODUCT. PLEASE 6/28/2018 CORRECT PRODUCT APPROVAL NUMBER ON PLANS TO REFLECT THE SITE SPECIFIC PRODUCT APPROVAL NUMBER. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: PRODUCT REVIEW AFFIDAVIT IS INCOMPLETE ON PAGE 8 OF 8. MULTIPLE N/A'S IN SECTIONS OF THE 6/28/2018 REVIEW AFFIDAVIT THAT NEEDS TO BE COMPLETED FOR REVIEW. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: I • PLEASE FURNISH DESIGN CRITERIA INCLUDING BUT NOT LIMITED TO WIND LOAD,DESIGN PRESSURES, 6/28/2018 EXPOSURE CATEGORY,I RISK CATEGORY AND DESIGN CODES IN ACCORDANCE WITH SECTION 301 OF THE FLORIDA RESIDENTIAL CODE ZONING REVIEW COMPLETE Lydia Galbraith 6/21/2018 6/21/2018 6/21/2018 Comment: