HomeMy WebLinkAbout1203-0230 COMMERCIAL HVAC LOADSdui �� St Lurie coot American Legion HVAC Load Analysis for American Legion St. Lucie County, FL C" j�- CO1`e+t1RCi€AL MIVAL; HVAC LOADS , 'tit 111CA100I e,�.� �G 3. S v0 ��oe �� !`e; G E N No 60982 o d AT OF .�,0 AIAL SB®��d6 0511%1% Prepared By: Eric J. Svoboda, PE Fort Pierce Engineering, Inc. 315 South 7th Street Fort Pierce, FL 34950 772-672-4636 Friday, October 14, 2011 Chvac FuIICommercial i IyAC Loads Calculation Program b �� Elite`Softwar"e Developrrient;'lnca j Amencan.Legion Page Bunding summaty Loads Building peaks in August at 2pm. Sen�{ Bldg Load' %°T,ot " #,Lat Sen %Net De-scri tions.. = . - Qua'n`, 'Lossb� Loss ; .. v G'ain Roof 6,089 8,037 8.99 0 10,671 10,671 3.32 Wall 3,000 9,405 10.52 0 5,378 5,378 1.67 Glass 300 8,217 9.19 0 12,535 12,535 3.90 Floor Slab 330 6,752 7.55 0 0. 0 0.00 Skin Loads 32,411 36.26 0 28,584 28,584 8.88 Lighting 12,178 0 0.00 0 41,553 41,553 12.91 Equipment 20,641 0 0.00 0 70,430 70,430 21.89 People 214 0 0.00 34,001 52,625 86,626 26.92 Partition 0 0 0.00 0 0 0, 0.00 Cool. Pret. 0 0 0.00 0 0 0 0.00 Heat. Pret. 0 0 0.00 0 0 0 0.00 Cool. Vent. 1,600 0 0.00 57,515 35,168 92,683 28.80 Heat. Vent. 1,600 56,973 63.74 0 0 0 0.00 Cool.lnfil. 0 0 0.00 0 0 0 0.00 Heat.lnfil. 0 0 0.00 0 0 0 0.00 Draw-Thru Fan 0 0 0.00 0 1,906 1,906 0.59 Blow-Thru Fan 0 0 0.00 0 0 0 0.00 Reserve Cap. 0 0 0.00 0 0 0 0.00 Reheat Cap. 0 0 0.00 0 0 0 0.00 Supply Duct 0 0 0.00 0 0 0 0.00 Return Duct 0 0 0.00 0 0 0 0.00 Misc. Supply 0 0 0.00 0 0 0 0.00 Misc. Return 0 0 0.00 0 0 0 0.00 Building Totals 89,384 100.00 91,515 230,267 321,782 100.00 -y.- $"'�"iw .-e^ Building j,Senr %Tot ; Lat k Sen Net a� %Net Surima Lossi4 LossY, Gain.& Gain`s. °Gain " Gain Ventilation 56,973 63.74 57,515 35,168 92,683 28.80 Infiltration 0 0.00 0 0 0 0.00 Pretreated Air 0 0.00 0 0 0 0.00 Zone Loads 32,411 36.26 34,001 193,192 227,193 70.60 Plenum Loads 0 0.00 0 0 0 0.00 Fan & Duct Loads 0 _.... --- 0.00 ............ .. -- 0 1,906 - 1,906 0.59 - - - -- --- -- ....___._...._ Building Totals 89,384 100.00 91,515 230,267 321,782 100.00 Check' Ni tires', r �, Total Building Supply Air (based on a 22° TD): 7,964 CFM Total Building Vent. Air (20.09% of Supply): 1,600 CFM Total Conditioned Air Space: 6,089 Sq.ft Supply Air Per Unit Area: 1.3080 CFM/Sq.ft Area Per Cooling Capacity: 227.1 Sq.ft/Ton Cooling Capacity Per Area: 0.0044 Tons/Sq.ft Heating Capacity Per Area: 14.68 Btuh/Sq.ft Total Heating Required With Outside Air: 89,384 Btuh Total Cooling Required With Outside Air: 26.82 Tons Z:1... \American Legion Heat Load.CHV Friday, October 14, 2011, 03:23 PM 'American, Leg icift 1 cle [—Air Handier #1 - AHU 1 - Summary Loads 1 Kitchen 448 3.249 57.394 1.925 Direct Direct 4pmAuguat 7 480 2.640 0 400 400 _�___ 5.37G O.8S 5�8H D 400 400 Zone Peak Totals: 448 2.249 57.394 1.025 Total Zones: 1 7 40O 2.640 O 400 400 � Unique Zones: 1 5.376 0.89 6.89 O 400 400 | Z:\'. \AmehuonLegion Heat Lood/CHV Fhdoy, October 14,2011.03:23Pw Chvac Full Commercial HVAC Loads CalculationzProgram Elite �' `Software Development; Inc.•' 1 z„h 3American Legion '� �• ` Pa 4. ,�- � � a Air Handler #1- AHU 1 - Total Load SrUmmary Air Handler Description: AHU 1 Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.25 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.97 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 4pm in August. Outdoor Conditions: Clg: 95° DB, 78' WB, 118.35 grains, Htg: 420 DB Indoor Conditions: Clg: 75' DB, 50% RH, Htg: 750 DB Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 2,249 Btuh Infiltration sensible loss: 0 Btuh Outside Air sensible loss: 14,243 Btuh Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: Heating Supply Air: 2,249 / (.999 X 1.08 X 5) _ Winter Vent Outside Air (100.0% of supply) = Zone space sensible gain: 57,394 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 632 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: Cooling Supply Air: 58,026 / (.999 X 1.1 X 20) _ Summer Vent Outside Air (15.2% of supply) = Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 8,792 Btuh Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: Total sensible gain on air handling system: 0 CFM 400 CFM 400 CFM 400 CFM 2,640 CFM 400 CFM 400 CFM 16,492 Btuh 58,026 Btuh 8,792 Btuh 66,818 Btuh Zone space latent gain: 1,925 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 14,379 Btuh Total latent gain on air handling system: 16,304 Btuh Total system sensible and latent gain: 83,121 Btuh Check:Fi 'uresw Total Air Handler Supply Air (based on a 20' TD): 2,640 CFM Total Air Handler Vent. Air (15.15% of Supply): 400 CFM Total Conditioned Air Space: 448 Sq.ft Supply Air Per Unit Area: 5.8926 CFM/Sq.ft Area Per Cooling Capacity: 64.7 Sq.ft/Ton Cooling Capacity Per Area: 0.0155 Tons/Sq.ft Heating Capacity Per Area: 36.81 Btuh/Sq.ft Total Heating Required With Outside Air: 16,492 Btuh Total Cooling Required With Outside Air: 6.93 Tons Z:\ ...\American Legion Heat Load.CHV Friday, October 14, 2011, 03:23 PM Calcuion Chvac FuIICommercial HVAC Loads latProgram'' F Ehte. Software DeveI60rrient,,Inc. Amencan,Legion 9 Pa ,. Air Handler #2 - AHU 2' - Summary Loads Zn Description Area Htg�LOS Seri GalnLat Gain ;=Htg O,AF Y CIg,:O A." NoZone¢SPeak TlrneP,eopl'e t Htg CFM+ j f C:Ig CFNI S Exh n �I Req CFM Req ,CFM' F. ft:,.,.CFM/.S ft�� W..Exh Act.CFM.ii. Act:CFlltl 2 Great Hall 2,000 8,862 52,772 15,500_ Direct Direct 2pm August 100 459 2,011 0 471 471 22,000 0.23 1.01 0 459 519 _... 3 Office ..... - — -__...... . 140 1,428 __.. _ 2,483 155 Direct Direct 9pm August 1 74 95 0 36 .. .36 1,680 0.53 0.68 0 74 24 4 Storeroom 210 1,054 3,069 217 Direct Direct 4pm August 1 55 117 0 54 54 2,520 0.26 0.56 0 55 30 5 Women 180 238 2,652 310 Direct Direct 3pm August 2 12 101 0 39 39 1,800 0.07 0.56 0 12 26 Zone Peak Totals: 2,530 11,582 60,976 16,182 Total Zones: 4 104 600 2,324 0 600 600 Unique Zones: 4 28,000 0.24 0.92 0 600 600 Z:\ ...\American Legion Heat Load.CHV Friday, October 14, 2011, 03:23 PM x` Elite Software Developmenf,'Inc. Chvac Full Commercial HVAC Loads Calculation Program z h i n d x »- 1 �, , Amencan Legion, j -F q, s . , P 1a 6' J Air Handler #2 - AHU 2 - Total Load Summer Air Handler Description: AHU 2 Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.22 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.79 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 2pm in August. r Outdoor Conditions: Clg: 95' DB, 78' WB, 118.35 grains, Htg: 420 DB Indoor Conditions: Clg: 75° DB, 50% RH, Htg: 75' DB Summer: Ventilation controls outside air, ---- Winter: Ventilation controls outside air. Zone Space sensible loss: 11,582 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 21,365 Btuh 600 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 32,947 Btuh Heating Supply Air: 11,582 / (.999 X 1.08 X 18) = 600 CFM Winter Vent Outside Air (100.0% of supply) = 600 CFM Zone space sensible gain: 60,739 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 556 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 61,295 Btuh Cooling Supply Air: 61,295 / (.999 X 1.1 X 24) = 2,324 CFM Summer Vent Outside Air (25.8% of supply) = 600 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 13,188 Btuh 600 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 13,188 Btuh Total sensible gain on air handling system: 74,483 Btuh Zone space latent gain: 16,182 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 21,568 Btuh 37,750 Btuh Total latent gain on air handling system: Total system sensible and latent gain: 112,233 Btuh Total Air Handler Supply Air (based on a 24' TD). 2,324 CFM Total Air Handler Vent. Air (25.82% of Supply): 600 CFM Total Conditioned Air Space: 2,530 Sq.ft Supply Air Per Unit Area: 0.9185 CFM/Sq.ft Area Per Cooling Capacity: 270.5 Sq.ft/Ton Cooling Capacity Per Area: 0.0037 Tons/Sq.ft Heating Capacity Per Area: 13.02 Btuh/Sq.ft Total Heating Required With Outside Air: 32,947 Btuh Total Cooling Required With Outside Air: 9.35 Tons Z:\ ...\American Legion Heat Load.CHV Friday, October 14, 'Lu11, 06:23 rive , . 5 : Chvac Fuli�Commeccial HVAC Loads n R Calculatiorogram r . Y EliteeSoftware Developmen(Inc. Amencan:Legion j > Pa- -Air Handler #3 - AHU 3 - Summary Loads Zn`. Description. Area ; Htg Loss Sen Gain it Lat.Gain " j tg O A �, CIg.O.A. No . Zone Peak Time P..eople + Htg CFM Clg C - M .S.Exh Req CFM �i , Req.CFM' i �' Volume. CFM/S 'ft� �CFM/S`ft i WExh Act CFM II Act.CFM,� 6 Men 130 172 2,051 310 Direct Direct 3pm August 2 8 82 0 24 24 1,300 0.06 0.63 0 6 16 7 Janitor .......... 21 ........... .......-_- - ... 28 - -- ---- - 286 22 Direct Direct 3pm August 0 1 11 0 4 4 210 0.06 0.54 0 1 2 8 Canteen 2,900 18,301 71,972 15,500 Direct Direct 2pm August 100 848 2,874 0 561 561 30,450 0.29 0.99 0 591 575 9 Liquor Storage 60 79 819 62 Direct Direct 3pm August 0 4 33 0 11 11 600 0.06 0.54 0 3 7 Zone Peak Totals: 3,111 18,580 75,128 15,894 Total Zones: 4 103 861 3,000 0 600 600 Unique Zones: 4 32,560 0.28 0.96 0 600 600 Z:\ ...\American Legion Heat Load.CHV Friday, October 14, 2011, 03:23 PM FChvac FuI Commercial HVAC Loads Calculation Program `' Ehfe`;$oftware De�elopmenY,anc. �a a Amencan Le910ri d ! Pa e 8 '] Air Handler #3 - AHU 3 - Total Load Summary Air Handler Description: AHU 3 Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.28 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.83 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 2pm in August. Outdoor Conditions: Clg: 95' DB, 78' WB, 118.35 grains, Htg: 42' DB Indoor Conditions: Clg: 75' DB, 50% RH, Htg: 750 DB Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 18,580 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 21,365 Btuh 600 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 39,945 Btuh Heating Supply Air: 18,580 / (.999 X 1.08 X 20) = 861 CFM Winter Vent Outside Air (69.7% of supply) = 600 CFM Zone space sensible gain: 75,124 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 718 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 75,842 Btuh Cooling Supply Air: 75,842 / (.999 X 1.1 X 23) = 3,000 CFM Summer Vent Outside Air (20.0% of supply) = 600 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 13,188 Btuh 600 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 13,188 Btuh Total sensible gain on air handling system: 89,030 Btuh Zone space latent gain: 15,894 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 21,568 Btuh Total latent gain on air handling system: ,4Btuh Total system sensible and latent gain: 126,492 2 Btuh Check,-Fi Total Air Handler Supply Air (based on a 23° TD): 3,000 CFM Total Air Handler Vent. Air (20.00% of Supply): 600 CFM Total Conditioned Air Space: 3,111 Sq.ft Supply Air Per Unit Area: 0.9645 CFM/Sq.ft Area Per Cooling Capacity: 295.1 Sq.ft/Ton Cooling Capacity Per Area: 0.0034 Tons/Sq.ft Heating Capacity Per Area: 12.84 Btuh/Sq.ft Total Heating Required With Outside Air: 39,945 Btuh Total Cooling Required With Outside Air: 10.54 Tons Z:1... \American Legion Heat Load.CHV Friday, October 14, 2011, U3:23 rnn