Loading...
HomeMy WebLinkAbout1203-0230- PROJECT SUMMARYShort Desc: American Legion Owner: American Legion Addressl: Savanah Club Blvd Address2: PROJECT SUMMARY Description: American Legion City: State: Zip: Type: Dining: Bar Lounge/Leisure Class: Jurisdiction: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) Conditioned Area: 6077 SF Conditioned & UnConditioned Area: No of Stories: 1 Area entered from Plans Permit No: 0 Max Tonnage If different, write in: i Port St. Lucie FL 0 New Finished building 6077 SF 0 SF 27.5 ♦`�,tilt A1998;"9'F®I ♦ .si. V O e4°�i� ;••° G E �c' �`� o�A� v a ►�! 82 b�• ° STATE OF AUG 0 g 2012 Public Works St. Fla/Com-2008, Effective: March 1, 2009 5/10/2012 Page I of'7 Sumlm Component Gross Energy Cost (in $) LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? Design Criteria Result 6,440.0 6,674.0 PASSED PASSES PASSES PASSES None Entered PASSES None Entered Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit@ Fla/Com-2008. Effective: March 1, 2009 5/10/2012 Page 2 of 7 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Eric J. S boda, PE Building Official: Date: Date: - I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (') that the system design is in compliance with the Florida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: _ Mechanical Designer: Reg No: _ Plumbing Designer: Reg No: (') Signature is required where Florida Law requires design to be performed by registered design professionals. Energy66Uge Summit® Fta/Com-200p, Effective: March 1, 2009 5/10/2012 Page 3 of 7 Project: American Legion Title: American Legion Type: Dining: Bar Lounge/Leisure (WEA File: FL ST LUCIE CO INTL.tm3) Building End Uses 1) Proposed 2) Baseline Total 401.90 490.80 $6,440 $7,851 ELECTRICITY(MBtulkWhl$) 401.90 490.80 117728 143795 $6,440 $7,851 AREA LIGHTS 73.20 76.20 21437 22332 $1,173 $1,219 MISC EQUIPMT 60.80 60.80 17807 17807 $974 $972 PUMPS & MISC 0.10 0.10 26 28 $1 $2 SPACE COOL 180.60 243.10 52905 71233 $2,894 $3,889 SPACE HEAT 33.80 0.00 9903 0 $542 $0 VENT FANS 53.40 110.60 15650 32395 $856 $1,769 Passing requires Proposed Building cost to be at most 85% PASSES of Baseline cost. This Proposed Building is at 82% EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009 5/10/2012 Page 4 of 7 Project: American Legion Title: American Legion Type: Dining: Bar Lounge/Leisure (WEA File: FL ST LUCIE CO INTLAW) External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) Ext Light 1 Uncovered Parking Areas -- Yes 0.15 42,500.0 6,375 2,000 Parking lots and Drives Tradable Surfaces: 2000 (W) Allowance for Tradable: 6693.75 (W) PASSES All External Lighting: 2000 (W) Complicance check includes a excess/Base allowance of 318.75(W) Project: American Legion Title: American Legion Type: Dining: Bar Lounge/Leisure (WEA File: FL ST LUCIE CO INTLAW) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq-ft) CP CP ance . PrOZoISp1 9 Food Service - Bar/Lounge 6,077 10 3 PASSES PASSES Project: American Legion Title: American Legion Type: Dining: Bar Lounge/Leisure (WEA File: FL ST LUCIE CO INTL tm3) System Report Compliance PrOSyl System I Constant Volume Packaged No. of Units System I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 13.00 9.50 9.80 9.70 PASSES 240000 to 760000 Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.46 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 3.50 PASSES System (Sup) PASSES EnergyGauge Summit@ Fla/Com-2008. Effective; March 1, 2009 5/10/2012 Page 5 of 7 Plant Compliance Description Installed Size Design Min Design Min Category No Eff Eff IPLV IPLV Comp liance None Project: American Legion Title: American Legion Type: Dining: Bar Lounge/Leisure (WEB File: F7 ST Li CIE CO INTL.tm3) Water Heater Compliance Description Type Design Min Category Eff Eff Design Loss Max Comp Loss liance Water Heater 1 Gas Storage water heater >75000 & 0.80 0.80 <=155000 Btu/h; < 4000 (Btu/h)/gal 978.28 PASSES PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond [inches] Runout? Temp [Btu-in/hr [F] SF.F] Ins Thick [in] Req Ins Compliance Thick linj None EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009 5/10/2012 Wage 6 0l' 7 Project: American Legion Title: American Legion Type: Dining: Bar Lounge/Leisure (WEA File: FL_ST LUC1E_CQ INTL.tm3) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Report 13-101 Input Report Print -Out from EnergyGauge FlaCom attachedEl Operations Manual 13-102.1, Operations manual provided to owner 13-410, 13-413 Windows & Doors 13-406.AB. 1. 1 Glazed swinging entrance & revolving doors: max. 1.0 cfm/ft=; all other products: 0.4 cfm/ft2 Joints/Cracks 13-406.AB.1.2 To be caulked, gasketed, weather-stripped or otherwise sealed Dropped Ceiling Cavity 13-406.AB.3 Vented: seal & insulated ceiling. Unvented seal & insulate roof & side walls System 13-407 HVAC Load sizing has been performed Reheat 13-407.13 Electric resistance reheat prohibited HVAC Efficiency 13-407, 13-408 Minimum efficiences: Cooling Tables 13-407.AB.3.2.1A-D; Heating Tables 13-407.AB.3.2. I B, 13-407.AB.3.2.1 D, 13-408.AB.3.2.1E, 13-408.AB.3.2F HVAC Controls 13-407.AB.2 Zone controls prevent reheat (exceptions); simultaneous heating and cooling in each zone; combined HAC deadband of at least 5°F (exceptions) Ventilation Controls 13-409.AB.3 Motorized dampers reqd, except gravity dampers OK in: 1) exhaust systems and 2) systems with design outside air intake or exhaust capacity<_300 cfin ADS 13-410 Duct sizing and Design have been performed HVAC Ducts 13-410.AB Air ducts, fittings, mechanical equipment & plenum chambers shall be mechanically attached, sealed, insulated & installed per Sec. 13-410 Air Distribution Systems Balancing 13-410.AB.4 HVAC distribution system(s) tested & balanced. Report in construction documents LAB.2 El Insulation 13-41 LAB In accordance with Table 13-41 Water Heaters 13-412.AB Performance requirements in accordance with Table 13-412.AB.3. Heat trap required Swimming Pools 13-412.AB.2.6 Cover on heated swimming pools: Time switch (exceptions); Readily accessible on/off switch Hot Water Pipe 13-41 LAB.3 Table 13-41 LAB.2 for circulating systems, first 8 feet of outlet Insulation pipe from storage tank and between inlet pipe and heat trap Water Fixtures 13-412.AB.2.5 Shower hot water flow restricted to 2.5 gpm at 80 psi. Public ❑ lavatory fixture how water flow 0.5 gpm max; if self -closing valve 0.25 gallon recirculating, 0.5 gallon non recirculating have been met Motors 13-414 Motor efficiency criteria Lighting Controls 13-415.AB Automatic control required for interior lighting in buildings >5,000 s.f.; Space control; Exterior photo sensor; Tandom wiring with 1 or 3 linear fluorescent lamps>30W EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009 5/10/2012 Page 7 of 7 Project Name: American Legion Project Title: American Legion Address: Savanah Club Blvd State: FL Zip: 0 Owner: American Legion EnergyGauge Summit® v4.00 INPUT DATA REPORT Proiect Information Orientation: North Building Type: Dining: Bar Lounge/Leistiie Building Classification: New Finished building No.of Stories: 1 GrossArea: 6077 SF Zones No Acronym Description Type Area Isq Multiplier Total Area Isfl 1 PrOZo 1 Zone I CONDITIONED 6077.0 1 6077.0 Spaces No Acronym Description Type Depth IN Width Height Multi IN IN plier Total Area lsq Total Volume lcf] 5/10/2012 EncrgyGauge Summit@ N,4.00 1 In "Lone: PrOZol 1 Pr0ZolSpl ZoOSPI Food Service - Bar/Lounge 59.00 103.00 11.00 1 6077.0 66847.0 ❑ Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: Pr0Zo1Sp1 1 Compact Fluorescent General Lighting 1 7000 7000 Manual On/Off 10 ❑ Walls No Description Type Width H (Effec) Multi Area Direction Conductance Heat Dens. R-Value IN IN plier [sf] [Btu/hr. sf. F] Capacity [Ib/cf] [h.sEFBtul [Btu/sf.FJ In Zone: PrOZol l PrOZo1Wa1 5/8" stucco 104.00 10.00 1 1040.0 North 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oe/.5" Gyp 2 PrOZo 1 Wa2 5/8" stucco 104.00 10.00 1 1040.0 South 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO - BTWN24"oc/.5" Gyp 3 PrOZo 1Wa3 5/8" stucco 63.00 10.00 1 630.0 East 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 4 PrOZo 1 Wa4 5/8" stucco 63.00 10.00 l 630.0 West 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BT WN24"oc/.5" Gyp 5/10/2012 EncrgyGaugc Summit® v4.00 Windows No Description Tvpc Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area [Btu/hr sf F] [ft] IN plier [sn In Zone: PrOZol In Wall: East 6.00 5.00 2 60.0 1 PrOZolWa3Wi1 User Defined No 1.2500 0.82 0.76 In Wall: North 0.76 2 90.0 I PrOZolWalWil User Defined No 1.2500 0.82 9.00 5.00 In Wall: South 1 PrOZo1Wa2Wi1 User Defined No 1.2500 0.82 0.76 6.00 5.00 5 150.0 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN IN plier [sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.FBtu[ In Zone: PrOZoI In Wall: North 1 PrOZo1Wa1Dr1 Solid core flush No 3.00 7.00 2 21.0 0.6061 0.00 0.00 1.65 0 (1.75") In Wall: South 1 PrOZol Wa2Dr1 Solid core flush No 3.00 7.00 2 21.0 0.6061 0.00 0.00 1.65 EJ (1.75") In Wall: East I PrOZo 1 Wa3Dr1 Solid core flush No 3.00 7.00 2 21.0 0.6061 0.00 0.00 1.65 (1.75") In Wall: West 1 PrOZol Wa4Drl Solid core flush No 3.00 7.00 2 21.0 0.6061 0.00 0.00 1.65 (1.75") Roofs No Description Type Width H (Effec) Multi Area Tilt • Cond. Heat Cap Dens. R-Value [ftl IN plier [sq [deg] [Btu/hr. Sf. F] [Btu/sf. FJ [Ib/cq [h.sf.F/Btu] 1In Zone: PrOZol 5/10/2012 F.nergyGauge Summit® v4.00 3 I PrOZoIRfI Mtl Bldg Roof/R-19 103.00 59.00 1 6077.0 0.00, 0.0492 1.34 9.49 20.3 ❑ Batt Skylights No Description Type U SHGC Vis.Trans W H (Effee) Multiplier Area Total Area [Btu/hr sf F] IN [ft] [Sf] [St] In Zone: In Roof: Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [st] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: PrOZol 1 Pr0Zo1F11 I ft. soil, concrete 103.00 59.00 1 6077.0 0.2681 34.00 113.33 3.73 ❑ floor, carpet and rubber pad Systems PrOSyl System 1 Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV I 2 3 4 Cooling System Heating System Air Handling System -Supply Air Distribution System (Sup) 330000.00 13.00 9.80 108000.00 1.00 8825.00 0.46 6.00 ❑ ❑ ❑ ❑ i/10/2012 EncrgyGauge Summit a0 v4.00 4 Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacity Cap.Unit I/P Rt. Efficiency Loss l Gas Storage water heater 55 [Gal] 130000 [Btu/h] 0.8000 [Ef/Et] [Btu/h] ❑ EA -Lighting Description Category No. of Watts per Luminaires Luminaire Area/Len/No. of units [sUft/No] Control Type Wattage 1W1 1 Ext Light I Uncovered Parking Areas -- 8 250 Parking lots and Drives 42500.00 Photo Sensor control 2000.00 ❑ Piping Operating Insulation No Type Temperature Conductivity [F] [ Btu-in/h.sf.F] Nomonal pipe Diameter (in] Insulation Thickness [in] Is Runout? El Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance (Btu/h.sf.F] 5/10/2012 EnergyGauge Summit® v4.00 ASHULSgICIrAII User Defined 1 1.2500 0.8200 0.7600 ❑ Fret Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used [h.sf.FBtu] [ft] [Btu/h.ft.F] [lb/cf] [Btu/ib.F] 187 Mad 187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 Li BOARD,1/2IN 178 Mad178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 0 42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 - 0.2000 ❑ block 4.19 0.3000 ❑ 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 94 Mat194 BUILT-UP ROOFING, 3/81N No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ Constructs Used Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/cf] [h.sf.FBtu] loll 5/8" stucco /8"CMU/3/4"ISO No No 0.21 5.73 34.65 4.8 ❑ BTWN24"oc/.5" Gyp Layer Material Material Thickness Framing No. [ft] Factor 1 268 0.625" stucco 0.0521 0.000 1:1 2 42 8 in. Lightweight concrete block 0.6670 0.000 ❑ 3 269 .75" ISO BTWN24" oc 0.0625 0.000 ❑ 4 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ 5/10/2012 FncrgyGaugc Summit® v4.00 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.Fl [Btu/sf.F[ [Ib/cq [h.sf.FBtul 1027 Solid core flush (1.75") No Yes 0.61 1.7 ❑ Layer Material Material Thickness Framing No. [ftl Factor 1 278 Solid core flush (1.75") 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sEF] [Btu/sEF] [lb/cfl [h.sEFBtul 1056 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.000 ❑ 2 23 6 in. Insulation 0.5000 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sEF] [Btu/sEFl [Ib/cfl [h.sEFBtul 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, I ft 1.0000 0.000 13 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ • 5/10/2012 EncrgyGauge Summit® v4.00 7