HomeMy WebLinkAboutDISAPPROVED DUCK LEAKAGE TEST REPORT6CANNI;U wuct Leakage Test Report
residential Prescriptive, Performan Z�1 V
e Ener �onserva ion, th iti
StLWIA orida Building Code, gy
Jurisdiction:
System 1
s¢� cfm25
System 2
cfm25
System 3
cfm25
Sum of any
additional systems
Cfm25
Total of all
systems
C,12cfm25
(Copy of License / Certificate of the tester must be
Certificate of Achievement
THIS ACKNOWLEDGES THAT
Austin Blankenship
HAS MET THE STANDARD REQUIRED BY RESNET, AS A
CERTIFIED RATING FIELD INSPECTOR
RFI # J87RSA
Certification Date: 05/07/2018
Certification Expires: 05/07/202.1
2
Tim Smith,
RESNET Quality Assurance Designee
15 11 lgh.tyears
3;
RESNET QA Provider # (1998-199)
RECEIVED
FORM R402-2017.
. NOV .� 6 Z018
Duct Leakage. Test Report pormittn
ent
Residential Prescriptive, Performance or ERI Method Compliance St Luce county
2017 Florida Building Code, Energy Conservation,-6th Edition.
Jurisdiction; 7Per it# 6 �c _o
0041 nforrnatlon
~#
Builder: Ryan Homes Community: Oakland Lake . Lot: 65
es
Address: 5313 Oakland Lake . Unit:
City: Fort Pierce State: FL Zip: 34951
Duct Leakage Test Results ` #' s
System 1
67
cfm25
System 2
cfm25
System 3
cfm25
Sum of any
additional systems
0M25
Total of all
67
systems
cfm25.
Performance / ERI Method cfrn (brit or Total`)
To qualify usi6 this method, Qn must not be-greaterthan,the
67 _ 1,452 = 0.046 Qn proposed duct leakage'Qn specifiled.on FormR405-201,7,or.R406-2017;
Total of all Total Conditioned
systems Square Footage Leakage Type selected on Form; Qn specified op,Form R405 201.7
R405 2017 (Energy Cal()'or R406-2017 (Energy Calc) or R406-2017
ffj
Proposed Qn 0..05
PASS FAIL
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section
553.993(5) or (7), Florida Statutes, or.individuals licensed as set forth in Section 489A 0.5(3)(f), (g) or (i), Florida, Statutes.
Testing Company
Company Name: : 15 Lightyears, Inc Phone: (855)-.438-1515
I hereby verify that the above duct leakage testing results are in accordance with the 2017 6th Edition Florida _Building Code Energy
Conservation requirements according to the compliance method selected above.
'
Signature of Tester: Date of Test: 11 /12/2018
Printed Name of Tester: J Aug In Blankenship
License/Certification #: J87RSA Issuing Authority:, RESNET .
(Copy of License / Certificate of the tester must be attached)
KI:
Certificate of Achievement
THIS ACKNOWLEDGES THAT
Austin Blankenship
HAS MET THE STANbARD REQUIRIED 88"RESNET, AS A
CERTIFIED RATING FIELD INS.P-E-CTOR
R F I # J87RSA
Certification Date.- 05107/201&
Certification �-xpirus.- 0610712021
_�"_�=� _-fir`_
Tim S mitil,
RE'SNET-Quality'Assurance besignee
15 lightyears
USNET QA -Provider # (109$-199)
_.,., .... Planning & Development Services__. .. ... .. _ ...
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982 RECEIVED
772-462-2165 Fax 772-462-6443
fl
FBC ENERGY CONSERVATION CODE NOV 1 2�,�
Duct Sealing Certification
Prescriptive and Performance Method r
Lut(e Count;y� PLtrmltting
Permit#:,
Contractor: Address: �313 n� (�� 4,. of Ly +ram CGr
Construction: Post Construction Test ❑ Rough -in Test
Test Conditions: Date: I1 l9Floor Area (ft2): 9 S_ oq
Time: L' 15 Primary Location of Supply Ductwork A `.
Indoor Temperature (F): -i � Primary Location of Return Ductwork t COAd 1 ;V
Outdoor Temperature(F):
Total Leakage Test (Outside) r
Duct Leakage: ❑ Default ❑ Prop. Leak Free *Proposed On =
Test Pressure: (Pa)
Baseline Duct Pressure (optional) (Pa)
Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: ❑ Pass ❑ Fail
Installed Pa
Total Leakage (cfm):
Total Leakage per 100 sgft: ® O;L&, a r, PP 9 7o
CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sgft.
Testing Company ` 7-76 k9�r
a4—* 10
Company Name: }\ i ► (�. ,,e, r3Address: L o�"i"roo�f 39-75-C-)
I hereby certify that the above Duct Sealing Leakage results demonstrate compliance with 5th Edition FBC Energy Conservation requirements in accordance with
Section R403.2.2.
Signature: .-� � Pew 6T
Printed Name: I i nn tA" '< w" : �' License/Certificate #: �) y —I
-HAS MET THE STANDARD REQUIRED BY RES NET, AS A
CERTIFIED HOME ENERGY RATER
AND
RESNET QUALITY ASSURANCE DESIGNEE
RTIN # 6821414
RESNET,
RESIDENTIAL ENERGY SERVICES NETWORK
4