Loading...
HomeMy WebLinkAboutFIELD & LABORATORY REPORTr I ti EDUNIVIEkS""'AL UES Project Date Typed: No.: July 24, 20181.0017 'ENGINEERING SCIENCES ������� Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection aY Building Code Administration, Compliance Inspection & Plan Review �n Lucip r'(11 820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978 }( i, Y Construction Materials Testing Services FIELD AND LABORATORY REPORT COVER PAGE _ - LO8 Client: Ryan Homes 1450 Centrepark Blvd Suite 340 AUGWest Palm Beach, FL 33401Project: Oakland Lake Subdivision Lot 28 ST. Luitting 5270 Oakland Lake Circle Permit No 1806-0499, Fort Pierce, St. Lucie County, FL As requested, Universal Engineering Sciences, Inc. (LIES) representative(s) performed construction materials testing and/or field inspection services on the above project. Testing results and/or inspection observations are reported on the attached sheets. The contents of this package are summarized below: Scope of Work Work Order No. Date Type of Report 98960-1 1 07/20/2018 In -Place Density Test Report w/Activity Record We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact the undersigned. 180.6--�3114qf Sincerely, Universal En, indc-Ang Sciences, -Inc. Certificate of, Whorization No. 00000549 ,,. Richard E. Hoaglin, P.E. FLORIDA Professional Engineer No. 48796 ICC Email: cbugg@nvrinc.com; elibrihi@nvrinc.com; iomcalli@nvrinc.com; sign/seal MAIL to ryan homes at 1777 Willows Square, Vero Beach, FL 32966 FILE COPY Revised May 2016 UNIV RSAL UES Pr6,_=t No: 0310.1700251.0017 UES DOCS No: UES Report No: 98960-1 ARC 072018 NdENGINEERING SCIENCES On -Site Time (hrs): 0.50 Consultants In: Geotechnical Engineering * Environmental Sciences Lab Time (hrs): 0.00 Geophysical Services - Materials Testing , Threshold Inspection Travel Time (hrs): 0.25 Building Code Administration, Compliance Inspection & Plan Review Total Time (hrs): 0.75 820 Brevard Avenue, Rockledge, FL 32956 - P: 321.638.0808 - F: 321.638.0978 Activity Record Client: Ryan Homes 1450 Centrepark Blvd Suite 340 West Palm Beach, FL 33401 Project: Oakland Lake Subdivision Lot 28 5270 Oakland Lake Circle Permit No 1806-0499, Fort Pierce, St. Lucie County, FL Date of Activity: Friday, 20 July, 2018 Technician: Tyler Tilley As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of earthwork testing for the lot 28. While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for lot 28. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet the project compaction requirements of 95% of the maximum dry density per ASTM D-1557. The Contractor was notified of the test results or a copy was left for their records. UNIVERSAL UUES Froject No: ES DOCS No 0310.1700251.0017 ENGINEERING SCIENCES UES Report No: 98960-1 DT072018 '01 Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978 In -Place Density Test Report Client: Ryan Homes 1450 Centrepark Blvd Suite 340 West Palm Beach, FL 33401 Project: Oakland Lake Subdivision Lot 28 5270 Oakland Lake Circle Permit No 1806-0499, Fort Pierce, St. Lucie County, FL Area Tested: lot 28 Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 07/20/2018 Lab: ASTM D1557 Modified Proctor Technician: Tyler Tilley Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions only and do not address the condition of the underlying soils below the tested depths. Test No. Location of Test Range Depth (inch) Proctor (2) Field Dry Density (PCF) Field Moisture % % Compaction Comments (3) 1 SE Corner 0 to 1 ft 12.00 21143 115.7 2.6 101 A 2 SW Corner 0 to 1 ft 12.00 21143 110.0 3.1 96 A 3 NW Corner 0 to 1 ft 12.00 21143 111.3 3.7 97 A 4 NE Corner 0 to 1 ft 12.00 21143 111.7 3.5 97 A (1) Ref. Datum: 0 = Top of Native (2) Maximum Optimum Proctor Dry Moisture # Density Content 21143 115.0 12.0 This test was performed without deviation from ASTM procedures. (3) Comments Key A. Compaction meets min. requirements B. Compaction does not meet min. requirements C. Moisture does not meet requirements D. Recompaction required E. Recompacted, Retested, Meets Requirements This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.