Loading...
HomeMy WebLinkAboutREVIEW-COMMENTSPlanning & Development Services Building & Code Regulation Division, 2300 Virginia Avenue Fort Pierce, FL. 34082 Phone:(772)462-2172 Fax:(772)462-6443 SCANW9M sly PROPERTY INFORMATION Address: 5270 Oakland Lake Cir City / State / Zip: Fort Pierce, FI 34951 Parcel#: 1311-800-0041-000/3 REVIEW COMMENTS JUL 10 2018 �►�,:�ed feAk AA sheers -r wecgy m1c S . P Owner(s): Ddc Oakland Estates Llc Jurisdiction: SAINT LUCIE COUNTY Zoning: PUD Lot#: 28 APPLICATION INFORMATION Permit Number: 1806-0499 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Robert P li Smithwick Business Name: Nvr Inc Business Addr: 1450 Centrepark Blvd Ste 340 City / State / Zip: West Palm Beach, FI 33401 REVIEWS AND COMMENTS ReviewTvoe Status Reviewed By ADDRESSING ASSIGNMENT PENDING Lori Bender Comment: DOCUMENTS MISSING 6/19/2018 Comment: 6/19/2018 Comment: ENVIRONMENTAL REVIEW Comment: FRONT COUNTER REVIEW Comment: PLANS EXAMINER REVIEW Comment: 6/28/2018 6/28/2018 Comment: Comment: 6/28/2018 Block: Automatic Sprinkler System? No Fax Number: 561-720-1341 Date Started PENDING Lashahna Ingram NEEDS NOC SENT CUSTOMER TO ERD WITH VEG PERMIT. VEG PERMIT IN DRAWER UNDER "N" NVR INC. FEE LOADED COMPLETE Lynn Swartzel 612012018 COMPLETE Lashahna Ingram 6/19/2018 INCOMPLETE William Durden 6/28/2018 Email: Rsmithwi@Nvrinc.Com Date Completed 6/20/2018 6/19/2018 Date Released 6/20/2018 6119/2018 PAGE 4 OF EIGHT OF THE SUBMITTED DRAWINGS NOTE NUMBER ONE, SPECIFIES PRIOR TO DRYWALL INSULATION ON ALL FRAMING MEMBERS 2 FOOT FROM THE FINISH FLOOR WILL BE SPRAYED AND TREATED WITH BORATE TERMITE TREATED SPRAYED. THE REST OF THE PLANS SPECIFY CLEAN COMPACTED TERMITE TREATED FILL. PLEASE CORRECT DRAWINGS TO SHOW ACTUAL CONDITIONS TO BE INSTALLED. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. PLANS SHOW LAP SIDING AND STUCCO DETAILS. PLEASE REMOVE FROM THE PLANS ANY INFORMATION NOT PERTAINING TO THE NEW STRUCTURE. SEE SECTION 107.2.4 OF THE 2017 FLORIDA BUILDING CODE. PLANS SHOW A BALCONY DETAIL NO BALCONY IS SHOWN ON THE ELEVATION PAGES OR THE FLOOR PLAN. PLEASE REMOVE FROM THE PLANS ANY INFORMATION NOT PERTAINING TO THE NEW STRUCTURE. SEE SECTION 107.2.4 OF THE 2017 FLORIDA BUILDING CODE. Planning & Development Services Building 4 Code Regulation Division, 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462-6443 REVIEW COMMENTS 2 Comment: - THE TOTAL MODIFIED LOAD ON THE ENERGY CAL MUST BE LOWER OR EQUAL TO THE TOTAL BASE LINE 6/28/2018 LOADS. SEE SECTION R405.3 OF THE 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION FIFTH EDITION. 6/28/2018 Comment: - PRODUCT APPROVAUNOA NUMBER 14039 - R-2 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: - PRODUCT APPROVAUNOA NUMBER 14039 - R-2 IS THE REVISION NUMBER FOR THE PRODUCT. PLEASE 6/28/2018 CORRECT PRODUCT APPROVAL NUMBER ON PLANS TO REFLECT THE SITE SPECIFIC PRODUCT APPROVAL NUMBER. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. 6/28/2018 Comment: - PRODUCT APPROVAUNOA NUMBER 5891 - R-5 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: - PRODUCT APPROVAUNOA NUMBER 5891 - R-5 IS THE REVISION NUMBER FOR THE PRODUCT. PLEASE 6/28/2018 CORRECT PRODUCT APPROVAL NUMBER ON PLANS TO REFLECT THE SITE SPECIFIC PRODUCT APPROVAL NUMBER. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. 6/28/2018 Comment: - PRODUCT APPROVAUNOA NUMBER 5219.3 - R-3 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. 6/28/2018 Comment: - PRODUCT APPROVAUNOA NUMBER 15216 - R-2 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: - PRODUCT APPROVAUNOA NUMBER 15216 - R-2 IS THE REVISION NUMBER FOR THE PRODUCT. PLEASE 6/28/2018 CORRECT PRODUCT APPROVAL NUMBER ON PLANS TO REFLECT THE SITE SPECIFIC PRODUCT APPROVAL NUMBER. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. 6/28/2018 Comment: - PRODUCT APPROVAUNOA NUMBER 18355 - R-3 IS OUTDATED. PLEASE CORRECT PRODUCT APPROVAL NUMBER ON PLANS. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: - PRODUCT APPROVAUNOA NUMBER 18355 - R-3 IS THE REVISION NUMBER FOR THE PRODUCT. PLEASE 6/28/2018 CORRECT PRODUCT APPROVAL NUMBER ON PLANS TO REFLECT THE SITE SPECIFIC PRODUCT APPROVAL NUMBER. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: PRODUCT REVIEW AFFIDAVIT IS INCOMPLETE ON PAGE 8 OF 8. MULTIPLE N/A'S IN SECTIONS OF THE 6/28/2018 REVIEW AFFIDAVIT THAT NEEDS TO BE COMPLETED FOR REVIEW. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: - PLEASE FURNISH DESIGN CRITERIA INCLUDING BUT NOT LIMITED TO WIND LOAD,DESIGN PRESSURES, 6/28/2018 EXPOSURE CATEGORY, RISK CATEGORY AND DESIGN CODES IN ACCORDANCE WITH SECTION 301 OF THE FLORIDA RESIDENTIAL CODE ZONING REVIEW COMPLETE Angela Huff 6/21/2018 6/21/2018 6/21/2018 Comment: