Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGo�da�'11!llti� `ry � eels Home 1 tog in i User Registration t Hut Toplrs I Subm(t Surcharge Stats & Facts i ;.;r'NM0' sg'r, Product Approval ',: USER: public User ftie:4 Ls3 Awa+val Menu > F-291re or Aord�rnti.n dear 1i > Anr.Ecstion t.ia > AppiipUon Detail Fl-# FL17022-R7 Application Type Code Version. 0-A-iPSx�Nd Application Status Publications i FSC.StaN I BCIS Site Map i Links I search I Comments 08/18/2017v. date reapply 08/21/17 Archived Product Manufacturer xtreme etaI Fatricators, LLC Address/Phone/Email 2160 SW Pom r v Palm City, FL 34990 (772) 872-8034 fivalidation@yahoo.com Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Life�crt_L:bFAST E E SORAlIACHMEiVTS ARc THE RESPONSIBILITY OF THE CONTRACTOR OR RECORD Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Richard McKuhen nva lidation@ya hoo.corri Richard McKuhen 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 richard@emfab.net THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer i_. Evaluation Report - Hardcopy Received LOCKE BOWAEN FILE COPY PE-49 PE-49 704 Keystone Certifications, Inc: 04/22/2024 Zachary R. Priest, P.E. Validation Checklist - Hardcopy Received FL17022 R7 COT FL 17022.1 S.V CRIMP ssr pdf Referenced Standard and Year (of Standard) Standard Year TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of product Standards Certified By Sections from the CodeL— ST. LUCIE COUNTY BUILDING DIV ION REVIEWED FOR COMPLIANCE REVIEWED R.1C A . n �� PLANS AND PERMIT MUST BE KEPT SITE OR NO INSPECTIONS) WILL I Palm City, FL 34990 Compliant with Florida Building Code 2017 (6t' ed.) • 4`Keystone Product: 5 V Crimp 26GA Steel Roof Panel FRC Sec.1507.4t.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment): # 9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*®r sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment); #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16D° min. thru deck. or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FRC Sec. Chan 1507.1.1 See. Fastener attachment specirications above Install Details- Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSf -93.S PSF -101 PSF -228 PSF ROM SPACING 16" O.C. 16" O.C. 8" O.C. 6" ox. FASTENER SPACING (ALONG Panel width) 12" o.c. 12" O.C.. 12" O.C. 12" O.C. FASTENER SIZE #9 #10 #10 #10 Reference Data: ARCiirrECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & 1897-041 Test Report I25893.01-450-18 OS/02/14 Test Report F3366.01-450-18 12/18115 TA5 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY--UL 1897-04 is equivalent to test standard UL 1897-12 *Resign ott�44►!t pressure margin of safety 2.1 Locke Bowden, P.E. does not have, not will acquire a financial in '�S q a+�cggymfacturing or distributing products under this evaluation. Locke Bowden, P.E. is not owned, operated, or controlled by aPdy conipa0j)n-Afl55 iure@, or distributing products under this report. o r -. _.A117 13 1 J, FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Paned - Detain Limitations: 1. Undei-layment to be compliance with current Florida Building Code (FBC)2017 61h ed. 2. Minimum slope to be compliant with Florida Building Code 2017 61' ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities wtjurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6t' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. 151z..2' or neater P;y+r.�d, or - Wood plank Y-4- 17° Panel Profile Nominal 12" a } Nominal 12' O.C. I O.C. Fasten f9 x 1-1/2" Min. or 410 X 1-112" Min. per cable "A" Hex Washet Head Screw Spaced 12"o.c. across the Panel Width Panel Referto Table "A" for Spacing Along Panel Overlap Length Deck-15132" or greater Plywood, .or -Wood plank