Loading...
HomeMy WebLinkAboutGENERATOR CONCRETE PADm N 0 0 AMERICAST GENERATOR CONCRETE PAD " I " GENERATOR__-__ 1p tb is i THICKNESS PAD DIMENSIONS: CONCRET GENERAT Fa- go,-,.-LENGTH-, PLAN -VIEW_- I CONCRETE PAD 4 ROAD MESH ' MASTERFIBER 2" ;MIN - t r; ° -- - -', c 4" MIN MACIOO 4. GROUND 2" MIN 45" 1 41 TYP. " " " �ENG'IN ISOMETRIC VIEW GENERATOR TABLE: (ON -GRADE APPLICATIONS ONLY) AMER1 AST umm.smedmcwA mm . MADE IN AMEMCA V FED TAX B m_ounu+ UCHN3S18999IMS0163 S303 P&Imc o Ara Fort'I'M" FL 3"12 _ TgL 772-97wos F= 771-164-o5m Emdk MlevQaneA-avMvaom of Chn.la�d�66101wMosen - HVHZ OR NON-HVHZ RISK EXPOSURE RISK EXPOSURE RISK } ,EXPOSURE - COUNTY I C D II C 1 D 'III,`IV P. BEACH ISOMPH 32.43 Psf 39.33 Psf 170 MPH 41.65 Psi 50.55 Psf 180 MPH' 46.70 P,.sf S6:67;Psf BROWARD 156 MPH 35.08 Psf 42.57 Psf 170 MPH 41.65 Psf 50.55 Psf 180 MPH 46.70 Psf 56.67 Psf MIAMI-DADE 165 MPH 39.24 Psf 47.62 Psf 175 MPH 44.14 Psi 53.57 Psf 186 MPH 49.86 Psf 60.52 Psf BRAND MODELS CAPACITY---- < _ _LENGTH-,." ; WIDTH/'�HEIGHT _ ;; WEIGHT ALLOWABLE 1 ii COMMENTS PRESSURE 1 QT02224ANAX ' (22KW '•-_. 62.2 In':. 29oO;in , 33.5 in 843 lb 60.52 Psf RG022 / RGO2224ANAX ,-22KW r 62.2 in 30.6 in',-38.6 in 905 lb 60.52 Psf RG025 / RG02515A ALUM j 25KW -' 62.2 in k.6 in :38.6 in 777 lb 60.S2 Psf RG025 / RG02515S STL '25KW__ , -62.2 in , ' 30*6 in\ . 38.6 in 865 lb 60.52 Psf RG027 / RG02724ANAX 27KW,.. ' "62:2.in=' ,30.6 in '38.6 in 940 lb 60.52 Psf ! RG030 / RG03015ANAX ALUM 30KW - 62 2 In � 30 61n 38.6 in 807 lb 60.52 Psf j RG030 / RG03015ANSX STL 30KW 62 2 in _ 30 6.In -38.6 in., , 895 lb 60.52 Psf L9 v RG032 / RG3224ANAX A 1 ' 32KW ., I ,j 7.6:8 m, 35 O In;i ; 46 liin- �1225 lb 60.52 Psf -UP TO EXPOSURE v RG036 / RG03624ANAX ALUM ;- 36KW ,,- „_ -76:8,in- -35:0;in= ­A0A in 1202 lb 60.52 Psf D 186 MPH RG036 / RG03624ANSX STL 36K1Na Ir 76 8 ins- 35 O in = 3'46.1 in 1255 lb 60.52 Psf j RG038 / RG3824ANAX 38KW 76.8 in 35.0 in 46.1 in 1235 lb 60.52 Psf RG045 / RG452ANA(C)(X) ALUM 45KW 76.8 in 35.0 in 46.1 in 1260 lb 60.52 Psf RG045 / RG452ANS(C)(X) STL 45KW 76.8 in 35.0 in 46.1 in 1313 lb 60.52 Psf RG048/ QT048 / RG4854ANA(C)(X) 48KW 76.8 in 35.0 in 46.1 in 1555 lb 60.S2 Psf j RG060 / ALUM 60KW 76.8 in 35.0 in 46.1 in 1422 lb 60.52 Psf i RG060 / STEEL 60KW 76.8 in 35.0 in 46.1 in 1539 lb 60.52 Psf 241RCL / 30RCL 24KW 33.0 in 74.0 in 46.0 in 1260 lb 60.52 Psf 30RES 30KW 34.0 in 72.8 in 36.8 in 1046lb UP TO EXPOSURE 60.52 Psf D 186 MPH Y 30REOL6 30KW 34.0 in 78.7 in 50.2 in 15601b 60.52 Psf B&S 076000 30KW 34.0 in 50.2 in 1560 lb 60.52 Psf UP TO EXPOSURE GE 076034 30KW 39.5 in �G.Oinj 41.5 in 1800 lb 60.52 Psf ! D 186 MPH It Cummins R522 / C22 N6 22KW 72.0 in 45.5 in 1109 lb 41.65Psf EXP C 170 MPH GENERATOR MOUNTING CONFIGURATION: GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE GENERATOR W/ (4) #SO SS 316 SELF -DRILLING SCREWS TO GENERATOR (SEE GENERATOR SPECS) WIND DESIGN REOUIREMENTS- (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE SIXTH EDITION (2017)) AT -GRADE SIGN METHOD ULTIMATE DESIGN WIND SPEED VUlt = 186 mph NOMINAL DESIGN WIND SPEED iVasd = 144 mph RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= 0.85 ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H qh = 77.56 Ib/ft2 FORCE COEFFICIENT Cf = 1.53 ' WIND PRESSURE: P = qh G Cf = 60.52 Ib/ft2 (ASD) GENERAL NOTES ANCHOR TO PAD SCHEDULE: SUBSTRATE DESCRIPTION (4)-3/8.0 TITEN HD CONCRETE: OR EQUIVALENT,2" (6000 PSI FULL EMBED TO MIN.) CONCRETE, 3" MIN. EDGE DISTANCE, 6" MIN. SPACING TO ANY ADJACENT ANCHOR. NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2. EMBEDMENT AND EDGE DISTANCE f ". EXCLUDES FINISHES, IF APPLICABLE; --w._ -3,.. ' ENSURE MINIMUM,E , DISTANCE _--AS NOTED IN ANCHOR SCHEDULE. _A; ENSURE MINIMUM SPACING TO ANY ADJACENT'ANCHORS. f 5 i FOLLOW MANUFACTURER'S :� '1 INSTALLATION INSTRUCTIONS TO - INS TALLANCHORS.',. GENERAE- OR 9� ATTACHMENT VARIES WITH MOSEE GENERATOR'S3/8"SIMPSON TITEN HSEE ANCHOR SCHEDU2"x3"x3/8" GALV. STEEL WASHER RUBBERVIBRATION PAD TH ICK ® T® GALVANIZED WASHER (� & RUBBER VIBRATION -PT _F AD ♦- F GENERATOR Z 0 (SEE CONCRETE PAD SCHEDULE FOR i w w CONCRETE PAD = I = DIMENSIONS &WEIGHT REQUIRED) 6;000. PSI x�/ LIGHTWEIGHT'-- �` CONCRETE MIX In NOTES } r 1! - =Y DISTANCE`DEPENDION GENERATOR BASE LENGTH, NO LESS T,HAN`2!"OR ANCHOR REQUIREMENT. 47" WIDTH } �- 45" LENGTH } 45" LENGTH } ;'__ _ ,'`' -12 ` x;DisTA_NCE 3"_;FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS SIDE VIEW FRONT VIEW THAN ANCHOR REQUIREMENTS CONCRETE PAD iv 6,000 PSI n LIGHTWEIGHT / I1 CONCRETE MIX MAST MAC 100 & ROAD MESH 2" FOAM CORE 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE SIXTH EDITION (2017). 2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN -ACCORDANCE WITH THE APPLICABLE -BUILDING CODE SHALLBE LESS_THAN-OR EQUAL TO THE DESIGN-PRESSURE"ASD CAPACITY VALUES LISTED HEREIN FORA NYASSEMBLYiAS SHOWN 3. DIMENSIONS AND WEIGHT OF UNITS SHALL'CONFORM TO SPECIFICATIONS'STATED HEREIN. 4. UNITS MUST BE CENTERED ON'PAD,WITH OPPOSITE SIDES HAVING EQUAL CLEARANCE A -MINIMUM DISTANCE'FROM UNIT TO PAD EDGE ISSPECIFIED.' 5. THE AREA UNDER CONCERETE-SLAB ON -GROUND -SHALL HAVE ALL VEGETATION STUMPS R 1 OOTS AND FOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY.OTHERS 6. RESISTANCE,TO_SLIDING_OF THE.PAD OWTHE GROUNDAS NOT PART OF THIS DOCUMENT AS ki'C2 HARACTERISTICS AND PAD PLACEMENT VARIES-. 7. ELECTRICAL GROUND' WHEN REQUIRED TCi BE�DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 8. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 9. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 10. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL_ BE COORDINATED BY THE PERMITTING CONTRACTOR: - 11. THIS DOCUMENT IS GENERIC AND. DOES NOT PERTAIN -TO ANY SPECIFIC PROJECT SITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR -SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL N&AdE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS. OR INACCURATE DATA a OR MEASUREMENTS'DIMENSIONS ARE SHOWN TO.ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA THEY•MAY VARY SLIGHTLY,' BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK:SHALL BE FIEL'D,VERIFIED BY OTHERS PRIOR TO CONSTRUCTION ,ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY `., ``" INACCURATE -INFORMATION PRIOR'TO MODIFICATION OF - -" EXISTING FIELD CONDITIONS AND ,,ERATIFABRICATIDWAND' INSTALLATION OF;MATERIAUK ALTONS_OR.ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. 12. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. VK L. BENNPffO, P.E. 0046549 01 1T4/jf 2018 L. BENAARDO, P.E. MATURE ON SHEET 1, THIS -ET IS PART OF A DIGITALLY iNED FILE, SHALL REMAIN IN iITAL FORMAT, & PRINTED PIES OF THIS DOCUMENT E NOT CONSIDERED SIGNEI D SEALED. IF THERE IS NO ;ITAL SIGNATURE ON SHEET 1 THIS SHEET DOES NOT VTAIN AN ENGINEER'S IGINAL SIGNATURE & SEAL, u 0 N Z �� ­1 It 00 E-1® W M ui v HMS u)U 111H oIn (Lu . In 00 WE LLNLLmXV)01 zW O 2 �C�aaf rrnn Fw>UV�xa U�Q W �QW.wL70 WWOLmo(D �;'O_zw- O N J m w w U 0'� W N O y v J l J U) cy E= w I O WL w O I] f� In 0 a z O J .~ C7 0 V / q tL In y = U] U°F- w " `" �7, W Ce .1 df w w -S a U) O W m�^ v g G o OLL a In Y w I m (D 0 O Lu r 'o 0 0 o i53� Yamm Uz _'J J zONp6 IL U a � J 12 6 z �+ O 0 O oow o g 3 5 zoa�� w�zz 0 a�g aw a w � �mNo 0 o zoz�o U)o jzoo�d' Y w o Q�Izurfo 0! h m . rnwLL r+FEoS � m ~ o f E ? s R COPYRIGHT ENGINEERING EXPRESS 17-3961.2 SCALE: NTS UNLESS NOTED OF