Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CONSTRUCTION PLANS
❑ / ITT F-- x ON I`7V 0 - DSO r RC2 I i 1. ... PL 2 1B -2 L adz_ _ adz -- PLC c� b�... b�- -a� a�1 an � RC3 1B2 1� 74 1g� 4 1B24, 1B22 1B2, a1�—I ,'i LV 0 1 B2-2 1 B2-2 GENERAL NOTES 1. ALL 2'R4' LUMINAIRES SHOWN ARE TYPE'A', UNLESS INDICATED OTHERWISE 2. REFERENCE THE LUMINAIRE SCHEDULE AND GENERAL NOTES ON SHEET E-0.1. 3. REFERENCE THE LIGHTING ROOM CONTROLLER WIRING DIAGRAM ON SHEET E-a. REFERENCE NOTES U LUMINAIRL SUBSCRIPTS IN THIS ROOM INDICATE A SINGLE BUTTON (ONE ZONE) CONTROLLING GENERAL LIGHTING ZONE A. O PLUG LOAD ROOM CONTROLLER FOR EACH RECEPTACLE INDICATED FOR PLUG LOAD CONTROL FOR THIS ROOM ON SHEET E-1. O LUMINAIRE SUBSCRIPTS IN THIS ROOM INDICATE SWITCHING/DIMMING CONTROLS FOR CONTROLLING TWO ZONES: GENERAL LIGHTING ZONE A, AND DAYLIGHTING ZONE ADZ. ® LUMINAIRE SUBSCRIPTS IN THIS ROOM INDICATE SWITCHING/DIMMING CONTROLS FOR CONTROLLING THREE ZONES: GENERAL LIGHTING ZONES A,B, AND C. OS CONNECT ALL THREE OCCUPANCY SENSORS IN THE CORRIDOR AND LOBBY USING 120V TO 24V POWER PACK SUCH THAT ACTIVATION OF ANY SENSOR TURNS ALL LUMINAIRES ON IN LOBBY AND CORRIDOR. ®I PLC LV,a LV 1B24 1B2-2 1 _2 L. - 3 PL � O b LV RC _.c ' a 1 1 B2-4 bn a� a - .- dz 182i4 � j,j I RC3 ao a B2 4 1B12 1B1 2 c� bn b�®" a1 j�j DSLV DSLV 1B2-4 1B24Q9 LV,a,b,c 1B2-4 ' a� u;G a 1 B2-2 162-2 . -- F JI!OS OS \. _ - Lk - 11 . . . . ...... . . ... IF -7 p�_l NL _ r NL 161- 12 1B.112 I 1B112 5 1B1-12 f 1B11 ID1�� �� H 1 L j 10 H1 4 I -- -. J � M H1 ---a _ DSLV 1D1� ®V. -- --cn -- 1C1-4 — — 1C1 j 1D1 2T DSLV c� cc0 I Vcc� co 1C1-2 1C1-2 1� 1DI-2 1D1-2 1D1- 1 1.2' i I ICI-2 1C1-2—I 1 \ __ 1D1-2 1D1-2 1D1-2 -- Y ` C� _..._ c�__._...._c' -ICU I l co -I cE I 2r 11(l 2� ® GIB it 1 1-21 u1 -- I c'" __ •Ill EPA r{' bE bo b�.. - _ bE bjb�1D12. �1D1-2 1C1-2 101-2 1C1-21G1-21 1D1-2 b -' 1D1-2 RC3 3 DSLV DSLV RC I bnl bo b b b 1l01-2 1G1 2, 1G1 2, 101-2 1D1-2 1D1-2 1D1-2 1D1-2 ^ � I LANS.ANDALL PROPOSED Wl _ AI,E SUB�CCT TQ AN 12 1 "� I I I REOUIR� it G(�f 1 C'ilCi°i5 Ile, rQ r=z _U av t,.:�� rr.spccTCjr' . a _ 1C1-4 m 1 MAY BE Ni:CESSARy 1N G'fls_ I I ' o CC:"!YVYIT✓•IAL APr"L.ivA ECOTE VDS a a ja a a a C14 1 C1-2 1 C1-2 1 D1-2 1 D1-2 1 D1 2, ul h _ I®LV _ ® i' RC2 alul P a 1 - a � a'� V._.....—a 0D1 _ �... = 1C1-2 1C1-2 1 1-2 14 1D1 1 �I.�I `........... .._ ®' LV,a,b c Ly a b c ®D1 r tI j —--_-L1�- U 13y 1 FILL Gw ---------- :1) FLOOR PLAN - LIGHTING 2 J 1/80 = V-0" R'ALEXj����i GE11s � �C: • to i No. 55422 = 4�k')w,6 O 1111 � 0NAI 10`\\� Sims Wilkerson Cartier Engineering, Inc. 12124 High Tech Avenue - Suite 200 Orlando, Florida 32817 FL. ERT. OF AUTH. O. 6106380-0400 FAX 00 18004 G GARY A. WILKERSON, P.E. 43167 p KYLE J. CARTIER, P.E. 53269 O JEFF A. KIRKMAN, P.E. 65629 G ADAM S. LEVINE, P.E. 77010 ■ SAMUEL R. ALEXANDER, P.E. 55422 Ld • ■■ • • • • • 11 • LLJ • ., - •. Ln ■ • ■■ • Uj ■ • • • Ld • > ■ (llp....r1ll ,nlllllll Ill,r...rrlli ...rn.......... Ifllllpu.......nllllllll .rnlllllllllllllllllllslr. IIIU-I�I�IIII ll-I-�l Ld ppQ lK � UM Q Ld � U m I— Ev u- H U w O lJ JVIl 'IM__ THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF EDWND DRIRNR45 BINNLEY' NiCNDEDTS, PA AND REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN MOLE OR IN PART IS EXPRESSLY PRO- HIBDEO WNHOUT WRITTEN PERMISSION. COMM. NO:120111VB DATE: 2ro FEB. 2016 BY: SWC CH'KD: SRA SHEET NO. EE � 2 WHT UNSWITCHED HOT BLK 277 EARTH GROUND CLASS 2 0-10VDC DIMMING DIMMING ROOM CONTROLLER LMRC-213 M0 0 0 0 0 2L m ® O OY 0> O> LIGHTING RED LOAD a LIGHTING YEL LOAD adz LIGHTING BLU LOAD b 0-10VDC DIMMING BALLAST REQUIRED, LED DRIVER, ETC. NEUTRAL WHT HOT_BLK 120VAC NEUTRAL WHT 120VAC PLUG LOAD CONTROLLER LMPL-101 AM== PLUG LOAD CONTROLLER LMPL-101 IDMDOC RED SWITCHED (OPTIONAL) RED SWITCHED (OPTIONAL) GENERAL NOTES 1. THE LIGHTING ROOM CONTROLLER DIAGRAM ON THIS SHEET REPRESENTS A GENERIC LAYOUT OF THE COMPONENTS THAT ARE REQUIRED USING THE WATTSTOPPER-LEGEND DESIGN SELECTION. REFERENCE THE LIGHTING PLANS FOR QUANTITIES OF COMPONENTS USED IN A GIVEN ROOM. 2. PROVIDE PROPER QUANTITY AND TYPE OF OCCUPANCY SENSORS, SWITCHES, ROOM CONTROLLERS, DAYLIGHTING SENSORS, ETC., PER CODE REQUIREMENT FOR EACH SPACE. 3. FOLLOW MANUFACTURER INSTRUCTIONS FOR PROPER PRODUCT PLACEMENT, INSTALLATION, WIRING AND OPERATION. 4. USE PRE -TERMINATED CAT5E CABLES WITH SPUTTERS AND COUPLERS AS NEEDED USING A FREE TOPOLOGY WIRING ARRANGEMENT TO CONNECT LIGHTING CONTROL DEVICES. SEQUENCE OF OPERATIONS 1. GENERAL LIGHTING (a, adz, b) AUTO ON TO 50% AND CONTROLLED RECEPTACLES AUTO ON WHEN OCCUPANCY DETECTED, 2. MANUAL ON/OFF/DIM GENERAL LIGHTING (a, adz, b) WITH DIMMER SWITCHES. 3. LIGHTING IN DAYLIGHT ZONE adz WILL CONTINUOUSLY DIM BASED ON DAYLIGHT CONTRIBUTION TO MAINTAIN AT LEAST 35fc AT TASK LEVEL. 4. AUTO OFF ALL LIGHTING AND CONTROLLED RECEPTACLES WITHIN 20 MINUTES OF OCCUPANTS LEAVING. 5. EMERGENCY LIGHTING TRANSFERS TO EMERGENCY POWER SOURCE BASED ON BATTERY DRIVER LUMEN OUTPUT AND FULL ON WITHLOSS OF NORMAL POWER. "BREAK -OFF REMOVAL ON HOT SIDE REQUIRED FOR SPLIT -CONTROL WIRING. "BREAK -OFF REMOVAL ON HOT SIDE REQUIRED FOR SPLIT -CONTROL WIRING, DUALTECHNOLOGY DUAL TECHNOLOGY SENSOR SENSOR MULTI ZONE DIMMER LMDC-100 LMDC-100 LMSW-105 LOCAL LIGHTING ROOM CONTROLLER WIRING DIAGRAM 1 E4 NOT TO SCP -E 120VAC CLOSE LOOP PHOTOSENSOR LMLS-400 0 0 0 0 MULTI ZONE DIMMER LMSW-105 PLUG LOAD CONTROLLER LMPL-101 A0' = RED SWITCHED (OPTIONAL) "BREAK -OFF REMOVAL ON HOT SIDE REQUIRED FOR SPLIT -CONTROL WIRING. THE ufi PLANS AND ALL PROPOSED WC)N PSE SUBJECT TO ANY COF?REC7IOf4s REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORD2R TO COI IPI'Y WITH ALL APPUCAME CCVES. Sims Wilkerson Cartier Engineering, Inc. 12124 High Tech Avenue - Suite 200 Orlando, Florida 32817 (407)380-0400 FAX (4 7)380-5900 FL. CERT. OF AUTH. NO. 6106 18004 0 GARY A. WILKERSON, P.E. 43167 0 KYLE J. CARTIER, P.E. 53269 0 JEFF A. KIRKMAN, P.E. 65629 G ADAM S. LEVINE, P.E. 77010 ■ SAMUEL R. ALEXANDER, P.E. 55422 t r w � a o _ Z_ CL W H (n cD 0tV Q N C4 O CN Q O ro W Mr7 in Ln a zo I Z ED U o a O-rn SOU) J N Q� 0 Z H = J Lij U >_ DO �j O J a 0 o TWO w to>D- N U W ~ o _ U (N +n ¢ Q z J Q W W 1 U Z LU 0 M U m V U_ U1 m �nU_ U LLJ O Of o O O_ L Z z 0 to w Izo J�_a__ THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE � PROPEIrtY OF MUND DPoTEHBPS 81%L MCHIIECTS, P.A AND REPRODUC➢ONS, DISCLOSURES OR USE THEREOF IN MHOIE OR IN AM IS UPRESSLY PRO- HIBRED IMNOUT WRITTEN PERMISSION, COMM. NO:1201PIVB DATE: 26 FE5. 2018 BY: 50JC CH'KD: BRA SHEET NO. E�4 EQUIPMENT BRANCH -CIRCUIT SCHEDULE JOB NUMBER: 180(4 DATE: 2/23/18 EQUIPMENT DESCRIPTION LOCATION VOLTS PH NEUT Y OR N MOTOR (LARGEST) ADDITIONAL. MOTORS NEATER OR LIGHTING LOAD MISC AMPS TOTAL AMPS PNL CKT BKR AMPS PANEL NAME DISCONNECT SNATCH STARTER VOLTAGE DROP WIRE PER PHASE NEUT WIRE GND WARE # OF RUNS CONWIT SIZE NOTES NAME SIZE AMPS FUSE SIZE AMPS SIZE NEMA TYPE 711577 HIP FiA kW AMPS INTERIOR LIGHTING TENANT SPACE 220 1 Y 90 i1,,;, 20 TENANT PNL 1;65% 012 012 #12 RECEPTACLES TENANT SPACE 120 1 Y : 7 5 IiG 20 TENANT PNL 1:60 #12 #12 #12 1 112" OWNER DEMAND METER ELECTRIC ROOM (SE) 120 3 Y 23 $,N 20 EXIST IS1 0.05% #12 #12 #12 1 1f2' ELECTRIC WATER EWH-1 MENS RESTROOM 208 1 N 3 5 16:a 17 25 EXIST 1B1 DS/EWH-1 30 NF 1.42% #8 #10 1 314" (g) ELECTRIC WATER EWH-2 WOMENS RESTROOM 208 t N ,15 168 17 25 EXIST 1B1 1%IEVJH-2 30 NF 1.42% #8 #10 1 3/4' (g) ELECTRIC WATER 3 STORAGE#1 208 1 N 60 28.8 29 40 _ICI fEWH-3 60 NF 0:87 >i6 010 1 3/4' (g) AIR HANDLER UNIT AHU5 MECHRM#1 (TENANT SPACE 81 208 3 IN 5.6 : 6 15 162 0.66' #12 2 1 V2• (c) DUCT HEATER D'+5 TENANT SPACE B 2ea 3 N 12 8 33 ? 33 45 182 DSlDH5 50 NF 1.52% #6 #t0 1 3l4' CONDENSING UNIT CU-5 EXTERIOR (TENANT SPACE B) 208 3 N 149 15 30 182 DSICU-S 30 30 1.59% #10 ON 1 3W (h) _ BLOWER COIL 3C-6 MECH RM #1 (TENANT SPACE C) 208 1 3 N 51 5 15 1C1 0.16 #12 #12 1 1I2' (c) MOTORIZED DAMPER MECH RM 01 (TENANT SPACE C) 120 ' 1 Y , ,, 1 15 ICI D,23% #12 #12 #12 1 112' DUCT HEATER DH-6 TENANT SPACE C 208 3 IN a 222 22 30 1C1 DS/DH-6 30 NF D.41 #10 #10 1 1/2- CONDENSING UNIT CU-6 EXTERIOR (TENANT SPACE C! 2D8 13 N 14 n 15 :: 30 /C1 DSICU-6 30 30 1:44 #10 _9 _1 3/4' (h) SLOWER COIL BC-7 MECHRM#2 (TENANT SPACE D) 208 - 3 N - 5.1 5 15 1D1 0.08 #12 #12 1 V2' (c) CONDENSATE PU'MPCP'9C7 MECHRM #2 (TENANT SPACE LA 120 _ 1 Y 2.0 2 15 1D1 MMS NF D.46% 1 412 #12 #12 1 V2" MOTORIZED DAMPER MECHRM42(TENANT SPACE D) 120 1 Y 1.7 1 15 101 0,23:. 012 012 #12 1 1/2' DUCT HEATER DH-7 TENANT SPACE E 208 3 N 83 22.2 22 30 101 DSIDH-7 30 NF 0, #10 *10 1 1/2' CONDENSING UNIT CU-7 EXTERIOR (TENANT SPACE D! 2tl8 3 N 149 15. 30 1D1 DS!CU-7 30 30 0.98 #t0 AB 1 374" (h) EXHAUST FAN EF-4 MENS R ST 120 1 Y 10 1 AS EXHSf 1 1 MI 5 iF .3 .. 42 M2 2 112 EXHAUST FAN EF-5 WUMENS RESTROOM 120 1 Y - 10 1 15 EXIST IB1 MMS WF 0.37% #A2 012 #12 1 112' (b) (1) - PROVIDE DSC. SW. AT ALL PIECES OF EQUIPMENT, UNLESS OTHERWISE TED ON THIS SCHEDULE. (2) - C.B STARTER, DISC. & FUSE SIZES SHOWN FOR REFERENC:_ ONLY, SIZ AS RECOMMENDED BY EQUIPMENT MANUFACTURER. VERIFY REQUIREMENTSWUHAPPP,,OVEDEQUIPMENT SHOP DRAWING& (3) . PROVIDE NEMA OUTDOOR RATED ENCLOSURES FOR ALL DSO. SM MOUNTED OUTDOORS. (4) • COORDINATE STARTER TYPE WITH EQUIPMENT PROVIDER, (5) • E. C. TO VERIFY THAT C. R'S FOR MOTORS ARE SUFFICIENT TO ALLOW 81 IIRTING OF MOTOR, IF REQUIRED FOR STARTING C.B. TO BE INCREASED TO A MAX OF 225%OF ARGEST MOTOR F.L.A. (6) • INCREASE FEEDER SIZES AS REQUIRED TO MAINTAIN A MAXIMUM OF 2.5 VOLTAGE DROP BASED ON ACTUAL FEEDER LENGTH$ AS INSTALLED. (7) - TOTAL AMPS SHOWN DO NOT INCLUDE NON -COINCIDENTAL LOADS - _ (a) - CONNECT VIA LINE VOLTAGE T'STAT, FURNISHED BY CIV, (b) - CONNECT VA ROOM LIGHTING OCCUPANCY SENSOR (c)-CONNECT VIA VFDFURNISHED BYDIV.15CONTRACTOR. (d) - CONNECT VA STARTER FURNISHED BY DIV. 15 CONTRACTOR- (a) - CONNECT VA UNIT WO DISC, SW. FURNISHED BY [AV 15. (I - CONNECT VIA STARTER FURNISHED WITH EQUIPMENT, (g) - LOCATE DISCONNECT SWITCH ADJACENT TO UNIT SERVED. (h) - PROVIDE DISCONNECT SWTCH W1TH NEMA 4X STAINLESS (i) - CONNECT VIA HOOD CONTROL SYSTEM. 15 CONTRACTOR STEEL ENCLOSURE ABBREVIATIONS: MCP= MOTOR CIRCUIT PROTECTOR C.B. MMS = MAN. MTR. STARTER 20A SW. WITH O.L. AND PILOT MSS =MOTOR STARTING 20A SW. WITHOUT 01 VFD = VARIABLE FREO, DRIVE UNIT. CSMC = COPS. DISC(MCP) AND MAG MOTOR STARTER(MMC) MMC = MAGNETIC MOTOR CONTROLLER VWO.I_ NF = NON -FUSED O.L. =THERMAL OVER LOAD ELEMENT I = NEMA I ENCLOSURE. 1 3R = NEW 3R ENCLOSURE 4SS = NEMA 4 W.P. STAINLESS STEEL ENCL. VOLTS L-N : 120 MAIN OPTIONS REQUIRED PANEL: 1132 ENCLOSURE DATA VOLTS PH. 208 SE RATED: NIA MCB: 100 AMPS NEMI PHASE:3 GFI PROT, NIA MLO NIA AMPS SECTIONS:1 MOUNTING: SURFACE SHUNT TRIP: NIA WIDTHVSECT.: 20 MFR: SCUARED DEPTH: 5.75 TYPE: HOOD AIC RATING (FULLY RATED): 42 kA (MINIMUM) NOTES DESCRIPTION LOAD AMPS AMPS AMPS C.B. C.B. CKT. CKT. C.8. C.B. AMPS AMPS AMPS LOA1 I DESCRIPTION NOTES CONN AMPS POLES NUM, NUM. POLES AMPS CON Recept-Reception 4 20 1 1 2 1 20 5 ! I 600 Ltg- 01 #1 NOW lReceplion Recept-Reception .-_ 20 1 3 4 1 20 5 600 Lrg- Classroom Recept- Conference 20 1 5 6 1 20 C SPARE - Recept-OKce - 20 1 7 8 1 20 SPARE Recept - Gass room 20 1 9 10 1 20 SPARE Recept - Classroom - - 20 1 11 12 1 20 - SPARE Recept-Classroom -- 3---- 20 1 13 14 1 20 0:.. SPARE SPARE - 20 1 15 16 1 20 r SPARE SPARE _ - j-_.' 20 1 17 18 1 20 �� -_- SPARE SPARE 20 1 19 20 1 20 , SPACE SPA.'.. 1:... 20. 1 21 22 1 20 C SPACE SPARE -i :! 20 1 23 24 1 20 7 -- SPACE AIR HAND F , ;,1 alU 5 c 15 3 25 25 1 20 1 SPACE 27 28 1 20 L SPACE 29 30 1 20 7 SPACE DUCT HEATER D[N,3 : 45 3 31 32 1 20 SPACE 33 34 1 20 C SPACE =s o f t -__ _= 35 36 1 20 C SPACE i CONDENSING JNI- CU 5 30 3^ 37 38 3 30 .'i SURGE PROTECTION DEVICE AMPS kVA 77 :AMPS PHASE A ACTUAL CONN. LOAD 69 25 67 AMPS PHASE B NEC DEMAND 69 25 65 : AMPS PHASE C PANEL NOTES, VOLTS L-N : 120 VOLTS PH.: 208 PHASE: 3 MOUNTING: SURFACE MFR: SQUARE D TYPE :NOOD MAIN OPTIONS REQUIRED. PANEL: S.E. RATED: NIA MCB: GFI PROT, : NIA MLO : SHUNT TRIP: WA ABC RATING (FULLY RATED): 1C1 225 AMPS NIA AMPS 42 kA (MINIMUM}. ENCLOSURE DATA NEMA:1 SECTIONS : I VWDTKSECT.: 20 DEPTH. 5,75 NOTES DESCRIPTION Recept- Mach Rm #1 LOAD COIN 2 AMPS 3 AMPS AMP S .,,N, { C.B. AMPS 20 C B POLES 1 CKT, NUM 1 CKT. NUM. 2 C.B. POLES 1 C.B, AMPS 20 AMPS 9 AMPS ' AMPS LOA D CONN ': 650 PT1 DESCRI ON L19 • Food Processing #1 NOTES Recept - Food Proe 01 4 11 20 1 3 4 1 20 111 1 500 Ug - Mech #1/Sror #t101f#2,#3 Recap- Food Proc # 1Sfer 1fl 5 P 20 1 5 8 1 20 ,,, J C SPARE Recall -Olice#2 4 i 20 1 7 8 1 20 0 SPARE SPARE _ : o _ 20 1 9 10 1 20 SPARE SPARE C 20 1 it 12 1 20 1 0 SPARE SPARE 20 1 1 13 14 1 20 0 -' SPARE SPARE- C 20 1 15 16 1 20 1: j SPARE SPARE .. ? 20 1 17 18 1 20 J SPACE SPARE J r 20 1 19 20 1 20 0 SPACE SPARE { 20 1 21 22 1 20 SPACE SPARE 20 1 23 24 1 20 , I 0 SPACE BLOVIER COIL BC 5 ;a. 15 3 25 26 1 20 0 SPACE _= 5 ) = 2' 28 1 20 1 SPACE _= 5 D --- -= 29 30 1 20 - SPACE DUCT HEATER DH6 22 30 3 31 32 1 20 0 ----�--�- SPACE — - _= 22 _ -= 33 34 1 20 ,� SPACE _= 22 - 22 =_ == 35 36 1 20 1 MOTORIZED DAMPER CONDENSING UNIT CU-6 15 1 , 30 3 37 38 3 30 C SURGE PROTECTION DEVICE is 4-0 6D 52 51 :AMPS PHASE A : AMPS PHASE B AMPS PHASE C ACTUAL CONN. LOAD: NEC DEMAND: AMPS 54 54 kVA 20 20 PANEL NOTES? VOLTS L-N : 120 MAIN OPTIONS REQUIRED PANEL: EXISTING PANEL iB1 ENCLOSURE DATA VOLTS PH 208 S. E. RATED: NIA VICE. 225 AMPS NEMA:1 PHASE :3 GFI PROT.: NIA ILO. NIA AMPS SECTIONS; 1 MOUNTING SURFACE SHUNT TRIP:. NIA WADTHSECT.:2D MFR : SQUARE D RENOVATE EXISTING PANEL DEPTH: 5 75 TYPE:NOOD AIC RATING (FUILLY RATED), 42 kA (MINIMUM) NOTES DESCRIPTION LOAD AMPS AMPS AMPS C.B. C.B. CKT, CKT. C.B. C.B. AMPS AMPS AMPS LOAD DESCRIPTION NOTE5 CONN AMPS POLES NUM. NUM, POLES AMPS CONN ELEC. CHRG ST EVST1 30 30 ' l 40 2 i 2 2 40 : 30 ELEC CH#2G ST EVST2 LTG-StEWMECH./ELEC. 780 20 1 5 6 1 2C SPARE 2) RECEPT -REBTROOMS 2 S ( 20 1 7 8 1 2C 1 285 LTG EXTERIOR !), LTG- SITE (double heads) 737 6 h r- 20 1 9 10 1 2C 737 LTG- SITE (single heads) 2) EX FANS Ef•4,EF•5 _ 2 29 i it 12 1 2C --00 LTG-LOBBYICORRIRESTRMS 21 RECEPT. SHELL 20 1 13 14 1 20 5 RECEPT SHELL RECEPT. EXTERIOR ^+ c 20 1 15 16 1 20 -3 RECEPT. ELECT.I EXT. 1) OWNER DEMAND METER 12- i 20 3 17 18 2 25 1 17 ELEC WTR HTR EWH-1- _ -- 21 22 2 1 25 - -�I t7 ELEC WTR HTR EWH-2 i) RECEPT, CORRIDOR 5 I r 20 1 23 24 == __- 1' 17 == 1) RECEPT. EXTERIOR 4 - 20 1 25 26 1 2CI SPARE RECEPT ELEC. RM 2 20 1 27 28 2 50 -.- 25 LIFT STATION PUMP .III(!! SPARE C 15 1 29 30 — _= �5 25 ==_ FIRE ALARM CNTRL PNL 5 0 1 20 1 31 32 1 20 1 - - 10 IT EQUIPMENT RACK SPARE I" :� 20 1 33 34 1 20 ,. 10 IT EQUIPMENT RACK SPARE 20 1 35 36 1 20 SPARE 1), 3) Panel 182 70 7� - 100 9 37 38 3 3C - SURGE PROTECTION DEVICE 1), 3) = 7011:"-, '' — 39 40 7, =_ 70 70 AMPS KVA 192 : AMPS PHASE A ACTUAL CONN. LOAD', 163 66 208 : AMPS PHASE B NEC DEMAND: 183 66 150 : AMPS PHASE C PANEL NOTES: 1) PROVIDE BREAKER INDICATED TO SERVE LOAD SHOWN, BREAKER SHALL HAVE SHORT CIRCUIT CURRENT RATING(SCOR) TO MATCH PANEL SCCR AT 240VAC 2) CONNECT NEW LOAD INDICATED TO SPARE BREAKER IN PANEL. 3) PROVIDE BRANCH CIRCUIT POWER METER TO MONITOR THIS LOAD AS INDICATED ON SHEET E-6 GENERALNOTES, 1. UPDATE PANEL LOAD DESCRIPTION AS INDICATED FOR LOAD DESCRIPTION IN BOLD TYPE. THESE PLANS AND ALL PROPOSED WOPiC ARE SUBJECT TO ANY COrMECTICNS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORD2M TO COF9PLY WiTH ALL APPLICABLE CGUE3. VOLTS U-N: 120 VOLTS PH : 208 PHASE : 3 MOUNTING: SURFACE MFR:SQUARED TYPE:NQOD MAIN OPTIONS REQUIRED PANEL: S.E. RATED: NIA VICE GFI PROT. WA MLC SHUNT TRIP: NIA AIC RATING (FULLY RATED): 1 D1 225 AMPS WA AMPS 42 kA (MINIMUM) ENCLOSURE DATA NEMA. 1 SECTIONS : 1 WDTHSECT.: 20 DEPTH:5.75 NOTES DESCRIPTION LOAD CONN AMPS AMPS AMPS C.B. AMPS O8, POLES CKT. NUM. CKT. NUM. C.B. POLES C, B, AMPS AMPS AMPS AMPS LOAD CONN DESORPTION NOTES Recept - Mach Rm lR 1 2 20 1 1 2 1 20 1 10 1150 Ug - Food Processing W Recept- Food Proc V 4 3 20 1 3 4 1 ,. : 3DO Lily- Mech 42,3tor #110fice #3 Recept- Foal Roc 0213tor 02 5 1" 20 1 5 6 1 - --- SPARE Recept- 011#3 4 Pce, 20 1 7 8 1 4201--- SPARE SPARE -'-' - 20 1 9 10 I SPARE SPARE 20 1 11 12 1 20 ;, SPARE SPARE C 20 1 13 1 14 1 20 1 SPARE SPARE „ 20 1 15 16 1 20 R _ SPARE SPARE 20 1 17 18 1 211 ., SPACE SPARE 20 1 19 20 1 20 ,!;:a SPACE SPARE ., T l_ 20 1 21 22 1 20 1' SPACE SPARE -�- C 20 1 23 24 1 20 i1 : 0 SPACE BLOWER COIL BC-7 6 C 15 3 25 28 1 20 SPACE 5 5 - -= 27 28 1 20 i I)„. SPACE 5 _ _= 29 30 1 20 0 SPACE DUCT HEATER D-1-7 22 22 33 3 31 32 1 20 SPACE -- 22 22 33 34 1 20 SPACE — 22 35 36 1 20 3 C PMP CP/BC•7 f MTR CMPR CONDENSING UNIT.CU-7 15 3p 3 37 38 3 30 0 SURGE PROTECTION DEVICE 39 40 0 54 51 53 15 .11 I : AMPS PHASE A : AMPS PHASE B : AMPS PHASE C 15'. --_ -= 41 42 =- __= ACTUAL CONN. LOAD NEC DEMAND : 0 AMPS 53 63 KVA 19 19 PANEL NOTES. `„� y$ 4 Is 1A li&� RIN fro @IA 'r I (i CEIVSR9L0ii�� �Q1 No. 55422 ��A STATE OF OR AA" I Sims Wilkerson Cartier Engineering, Inc. 12124 High Tech Avenue - Suite 200 Orlando, Florida 32817 F7)380-0400 FAX C4ERT. AUTHNO 6106� L.OF 18004 0 GARY A. WILKERSON, P.E. 43167 0 KYLE J. CARTIER, P.E. 53269 0 JEFF A. KIRKMAN, P.E. 65629 0 ADAM S. LEVINE, P.E. 77010 ■ SAMUEL R. ALEXANDER, P.E. 55422 • ■ Ji 11 • • • 11 V) coo ■ Cl • • ■ • Lij •■ • LLJ ■ • . • • In La M LLI • > ■ n�lllllllll,_,11111111111� IIIIII,Ip,.....n11,IIIlII • .Aelllllllllllllllllllnk. II 'I U10 Z L[J 4 � m (k u 'Q 1: LLl U O LU 01 N 1L F-- U O ILL. U QC U LU w 1 Z ,^ w O ui > oc p L.I Ui a V o � z © JI-AINL_I'a_ THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF OWND DRRENe15 DNXIEY AROHI71M, PA. AND REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART a EXPRESSLY PR0- HIBITED WITHOUT WRITTEN PERMISSON. COMM. NO:12011IVB DATE: 26 FEES, 2010 BY: SU1C CH'KD: BRA SHEET NO. E ELECTRICAL 100 PANEL FEEDER SCHEDULE JOB NUMBER: 18004 DATE: 02123/18 FEEDER FEEDNG CIRCUIT BREAKER FEEDER CAPACITY FEEDER LENGTH(l) FEEDER VOLT DROP % FEEDER AMP SIZE VOLTS PHASE PARALLEL RUNS PHk`' WIRE NEUTRAL TMRE ORCUND WIRE ISOLATED GROUND COPPER/ ALUMINUM CONDUIT SIZE PANEL 1B2 100 293 3 115 120 1,64 1 02 42 06 NIA COPPER 1-112- PANEL 1C1 225 206 3 230 60 0 71 1 #4,`0 010 #7 NIA COPPER 2-112' PANEL 1DI 225 23S 3 230 90 1.M 1 #11C #110 44 NIA COPPER 2-112' 2O� 2 - POWER RISER DIAGRAM NOT TO SCALE FA RISER REFERENCE NOTES O EXISTING 120 VAC DEDICATED CIRCUIT TO FIRE ALARM EQUIPMENT. O EXTEND EXISTING SIGNALING LINE CIRCUIT WITH NEW DEVICES SO AS TO REMAIN WITHIN FIRE ALARM SYSTEM VOLTAGE DROP AND BATTERY SIZING LIMITATIONS. O EXTEND EXISTING NOTIFICATION APPLIANCE CIRCUIT WITH NEW APPLIANCES SO AS TO REMAIN WITHIN THE FIRE ALARM SYSTEM VOLTAGE DROP AND BATTERY SIZING LIMITATIONS. DEVICES AT BACKFLOW PREVENTER FIRE ALARM RISER DIAGRAM NOT TO SCALE POWER RISER REFERENCE NOTES 0 EXISTING # 3/0 AWG COPPER GROUNDING ELECTRODE TAP CONDUCTOR. 2O EXISTING # 3/0 AWG COPPER GROUNDING ELECTRODE CONDUCTOR FROM MAN GROUND BUS (MGB) TO GROUND RODS. 3O EXISTING # 4 AWG COPPER GROUNDING ELECTRODE CONDUCTOR TO MADE ELECTRODES. ® EXISTING # 3/0 AWG COPPER GROUNDING ELECTRODE CONDUCTOR TO TELECOMMUNICATIONS GROUNDING BUSBAR (TGB) IN ELECTRICAL ROOM 100. O5 EXISTING (4) SETS OF 250kcmil IN 2-1/2" CONDUIT BETWEEN EQUIPMENT INDICATED. © ENCLOSURE MOUNTED TYPE 2 SURGE PROTECTION DEVICE. LOCATE SPD SOURCE BREAKER IN PANEL AS CLOSE AS PRACTICABLE TO SPD THAT IT SERVES. O EXISTING 400A RATED, 60OV, NEMA 1 ENCLOSURE DISCONNECT SWITCH FUSED AT 250A. REPLACE THE 250A FUSES WITH 225A FUSES. ® MAKE CHANGES TO EXISTING PANEL AS INDICATE ON PANEL SCHEDULES SHEET E-5. PROVIDE A BRANCH CIRCUIT POWER METER TO MONITOR THE POWER DEMAND AND ENERGY USAGE ON THE LOADS FROM PANEL 1B2 (TENANT B). PROVIDE METER WITH 5A CURRENT TRANSFORMER, AND WITH THE MINIMUM FOLLOWING REQUIREMENTS: ACCURACY: ANSI C12.20 CLASS 0.5 FOR REVENUE METERS COMMUNICATIONS: ETHERNET VIA UNSHIELDED TWISTED PAIR CABLES MEASURED VALUES: RECORD AND SAVE IN NONVOLATILE MEMORY, THE MINIMUM AND MAXIMUM VALUES OF ALL LISTED VALUES SINCE LAST RESET. REAL-TIME READINGS: CURRENT, VOLTAGE, REAL POWER (kW), REACTIVE POWER (kVAR), APPARENT POWER (kVA), ACTIVE ENERGY (kWh), REACTIVE ENERGY (kVARh), APPARENT ENERGY (kVAIT), POWER FACTOR, FREQUENCY, TOTAL HARMONIC DISTORTION DESIGN SELECTIONS: SCHNEIDER ELECTRIC POWER LOGIC METER #METSEPM5340 OR APPROVED EQUAL, PROVIDE WITH CORRESPONDING METER ENCLOSURE CONTAINING CURRENT TRANSFORMER SHORTING BLOCKS AND WIRING HARNESS. SEE SHEET E-1 FOR MOUNTING REQUIREMENTS. FA RISER GENERAL NOTES 1. SCREENED ITEMS ARE EXISTING TO REMAIN, AND BOLD ITEMS ARE NEW. 2. ALL CIRCUITS SHALL BE RATED POWER LIMITED IN ACCORDANCE WITH NEC ARTICLE 760. 3. CABLE INSTALLATION IN AREAS SUBJECTED TO MECHANICAL DAMAGE SHALL BE INSTALLED IN UL LISTED METAL CONDUIT OR RACEWAY. 4. ALL NOTIFICATION CIRCUITS SHALL BE 14 AWG MINIMUM JACKETED TWISTED PAIRS OR PER MANUFACTURERS REQUIREMENTS. 5. ALL STROBE FLASH RATES SHALL BE SYNCHRONIZED AS PER NFPA 72. 6. ALL FIRE ALARM EQUIPMENT 120 VAC CIRCUITS SHALL BE PROVIDED WITH SURGE PROTECTION AND BREAKER LOCKOUT. 7. SECONDARY POWER SUPPLY CAPACITY SHALL BE 24 HOUR STANDBY WITH 5 MINUTES OF ALARM. BATTERY BACKUP SHALL NOT BE LOADED MORE THAN 80%. 8. NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE LOADED MORE THAN 80% OF ITS LISTED OUTPUT. 9. VOLTAGE DROP ON ALL CIRCUITS SHALL BE NO GREATER THEN 15%. 10. COORDINATE DUCT SMOKE DETECTOR MOUNTING WITH MECHANICAL CONTRACTOR. DUCT SMOKE DETECTORS SHALL BE FURNISHED BY ELECTRICAL CONTRACTOR MOUNTED BY MECHANICAL CONTRACTOR AND WIRED BY ELECTRICAL CONTRACTOR. 11. ALL INITIATION DEVICES SHALL BE ADDRESSABLE POINT IDENTIFIED. 12. REFER TO FLOOR PLAN FOR FIRE ALARM EQUIPMENT COUNTS. NOT ALL FIRE ALARM EQUIPMENT IS SHOWN ON FIRE ALARM RISER. 13. ALL UNDERGROUND CABLES SHALL BE LISTED FOR WET LOCATION USE. 14. ALL FIRE ALARM JUNCTION BOXES AND CONDUIT SHALL BE IDENTIFIED AS BEING USED FOR FIRE ALARM USE. POWER RISER GENERAL NOTES 1. SCREENED ITEMS ARE EXISTING TO REMAIN, AND BOLD ITEMS ARE NEW. 2. REFER TO THE PANEL FEEDER SCHEDULE ON THIS SHEET FOR PANEL FEEDER SIZES. 3. REFER TO GENERAL NOTES ON DRAWING E-0.1. 4. REFER TO THE EQUIPMENT BRANCH CIRCUIT SCHEDULE, AND THE ELECTRICAL PANEL SCHEDULES ON SHEET E-5. THMZ Pt,M AND ALL PROPOK-D WORK ARE SUBJECT TO ANY C©P.REMICNS R£OUIR£D BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORD2M TO COMPLY WITH ALL AP PUCABLE CIODES. ALEX� CENS�c.tiO� ' No. 55422 � STATE 4/ i p.F F •. <ORI � /��/SS/ONAI1i`E?o\�\ Sims Wilkerson Cartier G� 1991 Engineering, Inc. W 12124 High Tech Avenue -Suite 200 Orlando, ro ' Orlando, Florida 32817 c PL CER . OF AUTH4 NO. 610600 18004 -rN 'Ims Wilkerson , Me i 0 GARY A. WILKERSON, P.E. 43167 ED,1DCCrIR 0 KYLE J. CARTIER, P.E. 53269 ndF16yL�' 0 JEFF A. KIRKMAN, P.E. 65629 L Ng1'i.'�ylt` ■ SAMUEL A. A EXANDER, P.E. 55422 r w V o Z w w m w �C) (n Q O m N LI-I M 1`0 m V, N o o ~ Q Z D I Z w Q C) o Z a a- Q a Li ^ 12CO J N Q Q H JQ� Z = U Q w ? DO ' J Q w O Z In 0:� O .O w 2 w CID > IL J Q w N Q II IY/ d L 4JI//� a 0 ll w�I m N LL U Ed O Q:� CL. O LL- U W LU 1 N Ln z 0 > w Q w ILA/ � W a 0 V z z © J-4N-_I�Pd__ THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF EDLUNO DRDEN&d BWKLEY MCHITECTS, PA. AND REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS EXPRESSLY PRO - METED WRHOUT WRITTEN PERMISSION. COMM. NO:12011IVB DATE: 26 PEE3.20I8 BY: SWC CH'KD: SRA SHEET NO. GENERALNOTE THE PLUMBING CONTRACTOR SHALL FIELD VERIFY CONDITIONS PRIOR TO ORDERING MATERIALS OR FABRICATING PIPING. GREASE TRAP SHALL BE FULLY ACCESSIBLE. FLOW CONTROL FITTING EQUAL TO ZURN Z-1108 — E.F. CONNECT NEW 2" GREASE LINE INTO GREASE INTERCEPTOR 1-1/2" VENT IN WALL TO ATMOSPHERE GENERAL NOTES 1. ALL FLOOR DRAINS SHALL BE PROVIDED WITH 1/2" TRAP PRI'4ER VALVE, PIPING, AND FITTINGS. 2. FIELD VERIFY ALL MEASUREMENTS PRIOR TO LAYING AND CONNECTING ANY PIPING, NOTIFY ARCHITECT OF ANY DISCREPANCIES. 3. PROVIDE SHOCK ARRESTORS FOR PREVENTING WATER HAMMER AT EACH BATTERY OF FIXTURES ON THE COLD AND HOT WATER SUPPLIES. PROVIDE SHOCK ARRESTORS AT ISOLATED PLUMBING FIXTURES. SHOCK ARRESTORS SHALL BE FACTORY FABRICATED AND LOCATED FULLY ACCESSIBLE. SHOCK ARRESTORS SHALL BE SIZED PER PLUMBING AND DRAINAGE INSTITUTE STANDARD WH-201. AIR CHAMBERS ARE NOT ACCEPTABLE. 4. MAINTAIN FIRE RATING AND WEATHERPROOFING INTEGRITY OF ALL PIPING PENETRATIONS. 5. ROUTE ALL PIPING ABOVE CEILINGS, WITHIN WALLS, OR IN CHASES EXCEPT AS SPECIFICALLY NOTED, L 6. PROVIDE ACCESS PANELS TO ALL VALVES WITHIN CHASEABOVE NON -ACCESSIBLE CEILINGS. SEE ARCHITECTURAL DRAWINGS FOR CEILING S ES. 7. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OLUMBING FIXTURE MOUNTING HEIGHTS AND DIMENSIONS. DO NOT SCALE DRA INGS. DRAWINGS ARE DIAGRAMATIC AND ARE INTENDED TO SHOW GENERAL ROUTING. 8. VERIFY ELEVATIONS OF SEWER PIPING TO WHICH NEW SEWERS ARE TO BE CONNECTED PRIOR TO INSTALLATION OF ANY PIPING. 9. THE CONTRACTOR IS EXPECTED TO ORDER MATERIALS IN SI FFICIENT TIME TO AVOID DELAYING THE COMPLETION OF THE PROJECT. DELAY IN DE IVERIES WILL NOT BE CONSIDERED A JUSTIFIABLE REASON FOR SUBSTITUTION OF MATERIALS. 3-COMPARTMENT SINK. COORDINATE EXACT LOCATION WITH OWNER. 2" GREASE INTERCEPTOR EQUAL TO ZURN 1171-500, ACID RESISTANT INSIDE AND OUT, RATED AT 20 GPM AND 40 LBS GREASE CAPACITY, 99 LBS, 32-3/8" LONG x 20-314 WIDE X 10" HIGH, 3 GREASE INTERCEPTOR DETAIL p_p NOT TO SCALE CONNECT NEW 3" SANITARY IN EXISTING FIELD VERIFY EXACT HEAT TRAP BALL VALVE LO UNION = (TYP) �— TEMPERATURE & PRESSURE EXPANSION TANK RELIEF VALVE EQUAL TO AMTROL ELECTRIC WATER DRAIN VALVE PIPE FULL SIZE 3" DEEP 24 GAUGE TO FLOOR GALVANIZED SHEET DRAIN M§16kDRAIN PAN 2 ELECTRIC WATER HEATER DIAGRAM p_0 NOT TO SCALE NO RECIRC. PUMP PLUMBING FIXTURE CONNECTION SCHEDULE ITEM DESCRIPTION WASTE TRAP VENT CW HW REMARKS WC-1 WATER CLOSET 4" INTEG 2" 1" FLR MTD FL VLV ADA L-1 LAVATORY 2" 1-1/4" 1 1-1/2" 1/2" 1/2" WL HG ADA L-2 LAVATORY 2" 1-114" 1 1-1/2" 1/2" 1/2" WL HG S-1 3-COMPARTMENT 2" 1-1/2" 1-1/2" 1/2" 1/2" FLR MTD ABBREVIATIONS CTR FLR HG FL VLV COUNTERTOP FLOOR HUNG FLUSH VALVE MTD MOUNTED GAL GALLONS SS STAINLESS STEEL ADA AMERICAN DISABILITIES ACT COMPLIANT WL WALL TK TANK INSTANTANEOUS WATER HEATER SCHEDULE I MARK EWH-1 & 2 GENERAL MANUFACTURER EEMAX MODEL NUMBER SP35 UNIT SIZE (IN) 9"L x 6"H x 3"D. OPERATIONAL WEIGHT (LBS) ELECTRICAL IKW INPUT 3.5 VOLTAGE/PHASE 208/1 ELECTRIC WATER HEATER SCHEDULE MARK EWH-3 MANUFACTURER A O SMITH MODEL DEN-40 STORAGE CAPACITY (GAL) 40 RECOVERY (GPH) 30 @ 80"R UNIT SIZE 45"H x 21" DIA. ENERGY -EFFICIENCY 96% OPERATIONAL WEIGHT (LBS) 446 KW INPUT 6.0 VOLTAGE/PHASE 208V/1 SHOCK ARRESTOR SCHEDULE P.D.I. SIZE FIXTURE UNITS 'SA -A' 1-11 'SA-B' 12-32 TYPICAL LAV4 REFER TO AF ELEVATIONS LAV. CONFIGI GRID STRAIN PROVIDE SET PENETRATIOI TYPICAL FLO( FINISHED FLC MAKE CONNECTION TRAP SEAL PRIMER P_0 NOT TO SCALE TRAP PRIMER VALVE INSTALL AS HIGH AS POSSIBLE UNDER FIXTURE. )LITE 1/2" COPPER PING CONCEALED IN ALL PLUMBING SYMBOL LEGEND SYMBOL/ABBREV. DESCRIPTION SANITARY PIPING GR GREASE WASTE PIPING — — — — — — — — — — VENT PIPING RAINWATER PIPING - - DOMESTIC COLD WATER PIPING DOMESTIC HOT WATER PIPING -- -- ---- --- DOMESTIC HOT WATER RECIRCULATING PIPING G NATURAL GAS PIPING A COMPRESSED AIR PIPING W FLOOR DRAIN OC HUB DRAIN �&— FLOOR SINK PIPING TEE UP O PIPING TEE DOWN 6 O PIPING ELL UP 0 PIPING ELL DOWN D4 GATE VALVE BALL VALVE O FLOOR CLEANOUT EXTERIOR CLEANOUT 11 O WALL CLEANOUT VALVE IN VERTICAL PIPE POINT OF CONNECTION ABBREVIATION DESCRIPTION AFF ABOVE FINISHED FLOOR BFF BELOW FINISHED FLOOR CONT CONTINUATION CW COLD WATER (POTABLE) DW DISHWASHER EWC ELECTRIC WATER COOLER FD FLOOR DRAIN FCO FLOOR CLEAN OUT GWH GAS WATER HEATER HB HOSE BIBB HWRP HOT WATER RECIRC. PUMP JS JANITOR SINK L LAVATORY O.F.C.I. OWNER FURNISHED CONTRACTOR INSTALLED SA SHOCK ARRESTOR LINO UNLESS NOTED OTHERWISE WC WATER CLOSET WH WALL HYDRANT WB WASHER BOX THESE PU UNS AND ALL PROPOS.D WORK ASE SUBJECT TO ANY COMIECTIOP•IS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDZIN TO COMPLY W1 ITH ALL APrPMABLE CCtrES. iy� Y dY � L'•J Y. `�.i iaY F Sims Wilkerson Cartier Engineering, Inc. 12124 High Tech Avenue - Suite 200 Orlando, Florida 32817 FL. ERT. OF AU6106 380-0400 XTH4 NO 000 18004 C GARY A. WILKERSON, P.E. 43167 ■ KYLE J. CARTIER, P.E. 53269 M JEFF A. KIRKMAN, P.E. 65629 G ADAM S. LEVINE, P.E. 77010 0 SAMUEL R. ALEXANDER, P.E. 55422 1Tr5 w Y a ^ o Z a w _ m VT w tz q tz W Q L) In OS O N C14 Q O wMM m Z N o a o ~ Q zo I U Q - 0) O Lo a a �__`^ J U N _ aUj F J Q � Z U >- 07 � w J Q O Z a 0 W Ln w = co > a UU LLJ I— < a o _ U N N � Q o z a J Q w N IIII IIIIIII � LI Z a llll--Illh�-- 1WL Q = LLI Ul �U LLLINOO_ m jI NIL H-- U w O a � O a L� z z 0 N W w a Z © THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPEIRY OF EDLUND DRREI&S BINKLEY ARCHRECTS, PA AND REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PORT IS EXPRESSLY PRO- WRITER WTHOUT WRITTEN PERMISSION. COMM. NO:120117v5 DATE: 2Fi FEB. 2010 BY: 8WC CH'KD: KJC SHEET NO. r,M y% I J rl r 1 1 CI A j, ��I F;XI�T' Il �di AI�111111171G "ICI 2-- — — 6Pi2V \ Lm I0 ' ua 11 ` �', E W H-3 DEMOLISH EXISTING FLOOR DRAINS. CAP EXISTING SANITARY LINE BELOW SLAB AND VENT PIPING ABOVE CEILING. — 1 2" FD-2I—I 4 2„ — _ 3 I S_1 o ` D2 1 I � D1 2 L-2 i LA d'T SF ACz'r I S2 W2 P-2 P-2 I 1 1 5 m m m m C 'Isz I E ::.:. Ll I , INTERICI)IR I 1rFr E.N7 EFLOOR PLAN - PLUMBING P-1 1/8" = 1'-0" f I 1 i 055Y THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR SAW CUTTING AND PATCHING THE FLOOR AS REQUIRED FOR THE NEW PLUMBING FIXTURE INSTALLATION. REFERENCE NOTES 10 CONNECT NEW SANITARY LINE INTO EXISTING BELOW SLAB, FIELD VERIFY EXACT LOCATION. O2 3" SANITARY LINE DOWN TO BELOW SLAB. O ABOVE GROUND GREASE TRAP. EQUAL TO ZURN Z-1 171-500,20 GPM / 70 LBS GREASE. ® INSTALL FLOOR DRAIN TRAP SEAT_ DEVICE EQUAL TO RECTOR SEAL MODEL SS2009V, CONFORMING TO ASSE 1072. O5 CONNECT NEW 1-1/2" COLD WATER INTO EXISTING. FIELD VERIFY EXACT LOCATION. REFERENCE NOTES - DEMO D1 DEMOLISH EXISTING COLD WATER PIPING SERVING THE EXISTING TRAP PRIMER AND CAP WATER AS INDICATED. D2 DEMOLISH EXISTING TRAP PRIMER AND CAP WATER PIPING BELOW SLAB AS INDICATED. PROCEDURE FOR SIZING GREASE INTERCEPTOR ACCORDING TO PDI STANDARD PDI-G101 THREE -COMP SINK: 16" WIDE x 20" LONG x 10.5" DEEP EA. BOWL CUBIC CONTENT: 16"x 20"x 10.5" = 3360 X 3 = 10080 CUBIC INCHES CONTENT IN GALLONS: 10080 231 = 43.36 GALLONS ACTUAL DRAINAGE LOAD: .75 X 43.36 GALLONS = 32.72 GALLONS CALCULATE FLOW RATE FOR 2 MINUTE PERIOD: 32_72 = 16.26 2 MIN. BASIS OF DESIGN: USE 20 G.P.M. FLOW RATE & 40 LBS GREASE CAPACITY THESE PLANS AND ALL PROPOSED WOPK ARE SUBJECT TO ANY CORRECTIONS 'REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL 10PLICAME COMES. GRAPHIC SCALE 0® N0 53269 W � 0-N p ;\\\�\\ Sims Wilkerson Cartier Engineering, Inc. 12124 High Tech Avenue - Suite 200 Orlando, Florida 32817 (40380-0400 FAX FL. CERT. OF AUTH. NO. 610600 18004 G GARY A. WILKERSON, P.E. 43167 ■ KYLE J. CARTIER, P.E. 53269 0 JEFF A. KIRKMAN, P.E. 65629 O ADAM S. LEVINE, P.E. 77010 0 SAMUEL R. ALEXANDER, P.E. 55422 R Ld - Y a o Z w m w O0 Q N O) O (n N Q O m LLJ M I'7 N H a o Zo I Z O-rn LLJI- a ILOU-) zo Q a JW ^ N LAI 0 H J Qv Z Ld U C10 W �Oz J a 0r o o (0>[L Ld H N a W 0 O U EQcis N a � n Q J a w vl IIIIIIII II J LI 1 Z LLI �` 61 LL Q = ui Ill(L �U ILI O m 0- �Nu U W O 0r O CL W N z O N w W a 0 zz © L_t3LY.-UGt__ THESE PIANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF EDLUND DPoRN&S SNIOV AACHTECTS, PA. AND REPRODUC➢ONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS DPRESSLY PRO- HIBTED WITHOUT WRITTEN PERMISSION. COMM. NO:120111V5 DATE: 20 FEE3. 2010 BY: SwC CH'KD: KJG SHEET NO. 2" rd, WASTE AND VENT RISER DIAGRAM NIS WC-1 WC-1 WASTE AND VENT RISER DIAGRAM NTS W1 P-2 1-1/2" E 3/4" (2)SA-'A' 3/4" OLD WATER RISER DIAGRAM SA --'A' 1-1/4" WC-1 1/2" I I L_1 J�vL=1 EWH-2 EWH-1 AND COLD WATER RISER DIAGRAM n S1 W1 P-2 P-2 REFERENCE NOTES 0 INSTALL FLOOR DRAIN TRAP SEAL DEVICE EQUAL TO RECTOR SEAL MODEL SS2009V CONFORMING TO ASSE 1072. 2O CONNECT NEW SANITARY LINE INTO EXISTING BELOW SLAB. (D EXISTING SANITARY LINE BELOW SLAB. FIELD VERIFY EXACT LOCATION. THESE PI.ANdS AND ALL PROPOSED WOFX A,RE SUN:lE'CT TO ANY CORRECTICNS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN O RDM TO CCNSiM INlTH ALL A?PLtCADLE CCt?E5. FILF WC-1 1 3" FD-1 — I WC-1 1 3" FD-1 L_1 CO EWH-2 EW -1 7 L-11 1 ENLARGED RESTROOMS - PLUMBING P-2 1/4" = 1'-0" THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR SAW CUTTING AND PATCHING THE FLOOR AS REQUIRED FOR THE NEW PLUMBING FIXTURE INSTALLATION Sims Wilkerson Cartier Engineering, Inc. 12124 High Tech Avenue - Suite 200 Orlando, Florida 32817 FL. CERT. OF AUTH. NO.6106 7)380-0400 FAX 0 18004 ❑ GARY A. WILKERSON, P.E. 43167 ■ KYLE J. CARTIER, P.E. 53269 0 JEFF A. KIRKMAN, P.E. 65629 0 ADAM S. LEVINE, P.E. 77010 0 SAMUEL R. ALEXANDER, P.E. 55422 Ld J Y a p - Z CL w m W Q COO (n 0) O Q O L+J M 14) En Q otOO ro o H Z 0 I Z U O - Q W 0 a J U CV d2LLJ U Z F— = —J Q QW U ). m O w J a O�0O t0 w 7- (.0 > IL of z a J Q w In LH II-- UA Q IY 4 6T U m D�U LLI O m f� II 1- E4 LLL F- U w O CL w0 11� 1 A 11- z z 0 N > W w a 0 0 z © � _��__ THESE PL S AND THE INFORMATION SHOWN HEREIN ARE THE PROPM OF EDLUND MtRENBIS BINNIEY ARCWTECTS, PA. AND REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS EXPRESSLY PRO- HIBRED WDHOUT WRITTEN PERMISSION. COMM. N0: 12fDII�VB DATE: 26 FEB. 2m18 BY: 5WG CH'KD: KJG SHEET NO. F 2