Loading...
HomeMy WebLinkAboutREVISION 12-13-18OFFICE USE NLY: DATE FILED: REVISION FE RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772)462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LO TION/SITE REVIS101 ADI REZ6,,_ Al,F Mtt'j ULte -fLfL4 DEI klLED DESCRIPTION OF PROJECT RE SIONS: e h a D CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: b(Ij BUSINESS NAME: I f I o h h ( rbinl Win STATE: (DAYTIME): - 739.7 UBUILDER INFORMATION: (DAYTIME: NA_ ADDRESS: ST. LUCIE CO CERT. #: _ ZIP: FAX: STATE: FAX: INFORMATION: CI STATE: ZIP: PHO (DAYTIME): _ FAX: cr►��. RECEIVED SLC :9123109 By Revi d 06130117 StorloNlItl+ DEC 13 2018 �• COP Permitting Department St. Lucie County, FL i k V � �'��VI> [I I� K' , '4 1_5, I EX. 12" WM I. 1� EX. 6 G.V ....._ _. '" EX.12' U E. _.. .. ............ .. .. __ - O.R.B. 1295, PG. 1926 _. I I KITTERMAN ROAD EX. 8 FM EX 16" WM. ., \\\ PROP. 2'xl" REDUCER r� 1" METER E .AND 1" RPZ-BFP '�—' • - ° ° T- " EX. 2" FM ' PROP. 6"x2" DBL STRAP SADDLE, EX FH PROP. 82±LF 6 PVC _ 2" GATE VALVE, 6t LF 2" POLY, - FIRE SERVICE ¢ f: 3" BRASS 90° BEND, St LF 2" BRASS I �p O S PROP. 1" PE /1 ..............w. PIPE, 2" BRASS ANGLE VALVE POTABLE SERVICE (PER PSLUSD DETAIL W-02) REMOVE CAP AND PLUG AND PROP LIGHT PO[ F (T1P) EXTIND EX. 6" WM AS NECESSARY ......... .. E.'s PROP. 6" ISOLATION VALVE - PER PSLUSD DETAIL W-07 (POINT OF SERVICE) I R I V AND P.LV. FDC' PROP. FDCCONTROL ° Y PROP. 6" DDC PROP (AFTER VALVE PER FIRE PLANS) I PROP. 68±LF 4" PVC PROP. 6"x6"x6" TEE _ I AND 6"x4" REDUCER PROP. 6"x6"x4 TEE, AND °p 15x LF 4" PVC _•_„„ I BLDG C t Ex:12.00' U.E. I PROP. 27N 6" PVC BLDG D 72,750 SF.{�� I 3 6,675 SF F.F.E. - 13.50'NAVD k' E F.F.E.=13.50'NAVD I I i a I PROP. 6" CO INV. EL. 10.55' I I I � I 12' VEHICULAR AND — 1 PEDESTRIAN EASEMENT , xr IROP PDc) (ORB 2930 PG 29) PROP. 6'x6"x4" TEE, I " : ° PROP. 106 6" PVC LATERAL i BLDG B AND 6t LF 4 PVC @ @ e"/FT MIN. SLOPE EX. PUMP STATION 11,250 SF PROP. 6"x6"x6" TEE, 6" F.F.E.aso'rvnw PROP. 6"CO PROP. WYE CONNECTION TO 0 6"x4" REDUCCERER INV. EL. 9.45' EX, @ INV. EL. 8.75'± X. L PROP. 26m LF 6' PVC AND ° FIRE HYDRANT ASSEMBLY ` ...... ...,. PROP. 26t LF 4" PVC I I \ .,".. �) P.O.S; ' 0,1 5 SF F.F.E.=1350NAVD / I ' I w llllll IIIIIII IIIIII IIIII I ` JIIIIIIIIII I � IIIII I�Ilji �,, IIIII I�IIIII III .IIIII I I I PROP. 4+N� 5° BENDS PROP. 67 LF 6" PVC LATERAL @ }'YFT MIN. SLOPE i I N co m O � i Z � o �, UTILITY NOTES O ­4 O O ;;u ;u = I 1. ALL FILL MATERIAL IS TO BE IN PLACE, AND COMPACTED BEFORE INSTALLATION OF PROPOSED UTILITIES. I 2. CONTRACTOR SHALL NOTIFY THE UTILITY AUTHORITIES INSPECTORS 72 HOURS BEFORE CONNECTING TO ANY EXISTING = = (ZD � --1 = 3. LINE. SANITARY SEWER LATERALS SHALL BE 6" PVC SCHEDULE 40 Vco00 4. MINIMUM TRENCH WIDTH SHALL BE 2 FEET. /) 5. CONTRACTOR SHALL MAINTAIN A MINIMUM OF 3 FT. OF COVER ON ALL WATER MAINS. = 6. EXISTING UTILITIES SHALL BE VERIFIED IN FIELD PRIOR TO INSTALLATION OF ANY NEW LINES. fm D D I 7. REFER TO INTERIOR PLUMBING DRAWINGS FOR TIE-IN OF ALL UTILITIES. 8. CONTRACTOR IS RESPONSIBLE FOR COMPLYING TO THE SPECIFICATIONS OF THE LOCAL AUTHORITIES WITH REGARDS TO v D I MATERIALS AND INSTALLATION OF THE WATER AND SEWER LINES. O 9. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS z ON THESE PLANS IS ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, Cs MEASUREMENTS TAKEN IN THE FWN IELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE, THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 10. CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY INSPECTIONS AND/OR CERTIFICATIONS REQUIRED BY CODES AND/OR UTILITY SERVICE COMPANIES. 11. CONTRACTOR SHALL COORDINATE WITH ALL UTILITY COMPANIES FOR INSTALLATION REQUIREMENTS AND SPECIFICATIONS. 12, ADD BENDS OR DEFLECT AS NECESSARY TO MAINTAIN PROPER PIPE CLEARANCES. MINIMUM T OF COVER OVER WATER LINE. IF 6" MINIMUM CLEARANCE OVER CONFLICT CANNOT BE MAINTAINED, THEN INSTALL WATER BELOW CONFLICT WITH 1' MINIMUM SEPARATION. sc lay� styildormol F 11 L E COPY t 7 �'D MINIMUM SEPARATION BETWEEN PSLUSD FACILITIES AND OTHER UTILITIES yy°t .lp�l m P9� uq 4 yg�yT^_4yn Sym`y 0 �E mt N z A D mO Da C A O IR N 3m ITT N1 (1) WATER MAIN SHOULD CROSS OVER OTHER PIPE, WHEN WATER MAIN MUST BE BELOW OTHER PIPE, THE MINIMUM SEPARATION IS iB". Q (2) RECLAIMED WATER REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C. Z (3) RECLAIMED WATER NOT REGULATED UNDER PART III OF CHAPTER 62-610, FA.C. (4) A PSLUSD FACILITY INCLUDES MAINS AND STRUCTURES FOR POTABLE WATER, WASTEWATER AND RECLAIMED WATER. WHEN A GRAVITY SEWER IS TO BE INSTALLED PARALLEL TO A DRAINAGE PIPE GREATER THAN 15" DIAMETER A MINIMUM HORIZONTAL SEPARATION OF 15' SHALL BE MAINTAINED; GREATER SEPARATION MAY BE REQUIRED BY PSLUSD FOR PIPES LARGER THAN 24" IN DIAMETER. WHEN A FORCE MAIN OR RECLAIMED WATER MAN z >° IS TO BE INSTALLED PARALLEL TO A DRAINAGE PIPE A MINIMUM HORIZONTAL SEPARATION OF 8' SHALL BE MAINTAINED; A GREATER SEPARATION MAY > BE REQUIRED FOR DRAINAGE PIPES LANCER THAN 48" IN DIAMETER, G � c WANT mum OTHER PIPE HORIZONTAL SEPARATION CROSSINGS (1) JOINT SPACING ®CROS$INOS (FULL JOINT CENTERED) GRAVITY OR PRESSURE SANITARY SEWER, WATER MAIN WATER MAIN QI 10'MI IMUM SANITARY SEWER FORCE MAIN, HORIZOC ITAL BENDS MIL/ 4° 221/V 45" f-L-� 10I L L"i 90' H Ir Bo° 10'T TEE �' IN -LINE VALVE NOTES: 1. THE REQUIREMENTS SET FORTH ABOVE WERE CALCULATED FOR PVC PIPE BASED UPON THE FOLLOWING ASSUMPTIONS: - SOIL CONDITIONS'. SILTY SAND ISM) TRENCH TYPE:3 (PIPE BEDDED IN 4" MINIMUM OF LOOSE SOIL WITH BACKFILL LIGHTLY COMPACTED) - MINIMUM COVER: 3 FT - SAFETY FACTOR: 15 .TEST PRESSURE: 150 PSI - • SIZE ON SIZE TES & 5' LENGTH ALONG RUN 2. IF FIELD CONDITIONS DIFFER FROM THE ABOVE, THE ENGINEER -OF -RECORD (EOR) SHALL SUBMIT CALCULATIONS BASED ON THE FIELD CONDITION FOR REVIEW AND APPROVAL OF PSLUSD. MIXIMVM CONSTq VCT10N STANOARON FOR DETAIL: D`O9 F � clrr OP PORT aT. wen=. PIPELINE RESTRAINT DATE: 201s '!90D a.a. o.OVX LAIM 'PORT ST. wcle, FL a9aw REQUIREMENTS (HORIZON TAL) SCALEI N.T.B. PHONE (772) aFY6400 PAX(772) 87S6433 HORIZ TAL- L(FEET) DIAMETER 11114° 22-112° 45° 90• TEE* VALVES OR BRANCH DEAD END 4" 2 4 8 18 20 39 6" 3 5 11 25 38 55 B" 4 7 14 33 52 ]2 10" 4 8 16 39 65 8] 12' 5 9 19 45 80 102 14` 5 11 21 51 93 116 i6" 8 12 24 5] 10] 131 18" 7 13 28 63 120 165 20" 7 14 29 66 133 159 24" 8 16 33 79 757 185 30" 10 19 39 93 792 222 36' 11 27 44 106 225 257 42" 12 24 49 117 254 289 48" 13 2fi 53 128 283 321 ROUNDED CONCRETE OR CAP 6" SCH 40 STEEL PIPE OR DIP FILLED_/ WITH AND SET IN CONCRETE TWO COATS OF YELLOW PAINT '.�;SLOPE CONCRETE TO DRAIN-YY EXISTING GRADE, 0.35 YW CONC. MIN. ` ROUNDED CONCRETE OR CAP 6" SCH 40 STEEL PIPE OR DIP FILLED_/ WITH AND SET IN CONCRETE TWO COATS OF YELLOW PAINT '.�;SLOPE CONCRETE TO DRAIN-YY EXISTING GRADE, 0.35 YW CONC. MIN. ` ' (3000 F.B.I.) +1' MINIMUM CONSTRUCTION STANDARDS FOR CITY OF PORT BT, LUCIE 900 B.E. OGDEN LANE PORT ST. LUCIE, FL 34983 •..n"�" PHONE (772) 873-6400 FAX OFa) 373.6433 i PAVEMENT XISTING BASE FILE NAME: 0-15 BOLLARD DETAIL DATE, 2013 SCALE: H.T.S. - SHEET:1 OF 1 DLID COPPER LOCATOR WIRE TRENCH WIDTH BE PLACED ON TOP OF PIPE LOOPED AT EACH BELL FOR ILL WATER AND FORCE MAINS FINAL \ I X 1CKFlLL �-SEE NOTE #4 I- I TAMP) 6" MIN. 6"MIN. ITMAX 12 MAX. �J (FLAT \ f a INITIAL 4 y BACKFILL \\ \ PIPE ONE PIPE A (SIDE TAMP) BEDDING UNDISTURBED SOIL i. FORENCHES REQUIRING SHEETING, SHORING, STAY BRACING, TRENCH JACKS OR TRENCH BOX, DIMEN NS SHALL BE TAKEN FROM THE INSIDE FACE OF THE SUPPORTS. 2. IF TH MAXIMUM TRENCH WIDTH MUST BE EXCEEDED, THE AREA OUTSIDE OF THE MAXIMUM EMBEDMENT SHALL BE COMPACTED TO FINAL BACKFILL REQUIREMENTS. IF THE PIPE IS INSTALLED IN A COMPACTED EMBANKMENT. THE EMBANKMENT SHALL BE IN PLACE AND COMPACTED TO 12" MIN. COVER BEFORE INSTALLATION OF PIPE. 3. IF BEDDING IS REQUIRED TO BRING TRENCH BOTTOM UP TO GRADE AND PROVIDE UNIFORM AND ADEQUATE LONGITUDINAL SUPPORT UNDER THE PIPE, THEN A MINIMUM COMPACTED DEPTH OF 4 TO 8 INCHES OF SELECT EMBEDMENT MATERIAL IS REQUIRED, 4. THE INTRACTOR SHALL COMPLY WITH REQUIREMENTS OF THE FLORIDA TRENCH SAFETY ACT 5, AN A ROVED LOCATOR WIRE SHALL BE USED. 6. EARTHWORK, EXCAVATION, BACKFILL AND COMPACTION SHALL BE IN ACCORDANCE WITH PSLUSD (2\ INIMUM CON9TRVCTI0N BFANOgPgB FOR DETAIL; 604 r7„fit'; rrofeonrsr.LueN STANDARD PIPE TRENCH CROSS pare:3ols +� 80 B.E. OpDEX LANE � CRT 6T. LVCIEr EL 99909 SECTION BCPLE: N.T.S. „•,�,-,�., NONE (]731 pT9.p400 TAX (T73)879.0983 "..... • .. • VE ICAL BENDS I-L{ I`I n 1/4 t t/a• az 1/z zz t/z• I L I L � i� 45' 45' HO L VER AL OFFSET-L (FEET) DIAMETER 11-114• -1/2° 45' ee^ UPPER BEND LOWER BEND UPPE BEND LOWER BEND UPPER BEND LOWER BEND UPPER BEND LOWER BEND 4" 4 2 6 3 V 5 39 71 6" 6 2. 11 4 23 7 55 15 8" 8 2 15 4 30 9 72 20 10 9 d iB fi 66 iq 87 24 12" it 3 21 6 43 - 12 102 28 10' 12 4. 24 7 49 14 718 32 i6' 13 4 27 8 55 18 13/ 36 18" 15 4' 29 8 60 17 145 40 20" 18 5 .32 9 68 19 158 44 24" 79 6 37 11 785 51 30" 22 T 45 13 222 fit 38" 26 8 52 15 256 ]742"56 i6 In 289804fl'6418 320 89 NOTES: 1, THE REQUIREMENTS SET FORTH ABOVE WE CALCULATED FOR PVC PIPE BASED UPON THE FOLLOWING A$$DMPTIQNS:, I ' -SOIL CONDITIONS: SILTY SAND ISM) -TRENCH TYPE:3 (PIPE BEDDED IN 4" MINIMU F LOOSE SOIL WITH BACKFILL LIGHTLY COMPACTED) -UPPER SIDE MINIMUM COVER:3 FT -LOWER SIDE MINIMUM COVER: SFT -SAFETY FACTOR: 1.5 - TEST PRESSURE: 150 PSI 2. WHEN CONDITIONS DIFFER FROM THE ABOV THE ENGINEER -OF -RECORD (EOR)01-0ALL SUBMIT CALCULATIONS FOR REVIEW AND APPROVAL PSLUSD. 3, ALL JOINTS BETWEEN UPPER AND LOWERB OS SHALL BE RESTRAINED. MINIMV M GON9TPVCTION 9TAHOapD9 FOp clrr DF PopT ST. wcl¢ PIPELINE RESTRAINT DETAIL: 6-q9 DATE: 2016 9009.E. OOOEN LANE roar an LUCIE, FL aeaea REQUIREMENTS (VERTICAL) scaw: N.T.S.PHoxe (772)e79.6490 PaN (773)ei3.e499 8H6Eh 1 OF 1 REDUCED PRESSURE ZONE (RPZ) BACKFLOW PREVENTION ASSEMBLY METER SIZE METER SPACE 5 2" B SEE CHART FOR METER SPACING VALVE 5 8" % 3 4" 7-1/2" TYPICAL) T.10-3 4° / 1 "-1 2" 13" / 2" 17" ANGLE VALVE METER VALVE J METER '. W/LOCK (BRASS) 12" MIN. ' PACK JOINT 24" MAX. TYPE "K" COPPER UTILITY CUSTOMER OR BRASS MAINTAINED MAINTAINED TO BUILDING SEE STANDARD VALVE / \ BOX DETAIL G-07 / \ FINISHED GRADE I � ''. I VARIES MALE RON PIPE THREAD PACK DINT COUPLING (BRASS) POLYETHYLENE PIPE SERVICE SADDLE 24"�iI WATER, SEWER OR REUSE �•- <" CAST IN COVER AS APPLICABLE 3'0 X }" TH@K BRONZE DISC ANCHORED IN CONCRETE q^ WIRE PORT PAD WITH HOOK DISPLAYING e" DEEP LETTERS CAST INTO DISC ®TATING NUMBER OF TURNS TO OPERATE & SCHEMATIDALLY IDENTIFIED MAIN &VALVE LOCATION 24" A 6°GV A -q}7,. XX, TURNS r•-3 CONCRETE VALVE COLLAR PIN FOR y ANCHOR -"'- ---Ill SECTION A -A Yf4 RESAR 24"X24"XIT' THICK r CONCRETE COLLAR FINISH GRADE MATCH EXISTING SURFACE `•� ROAD MATERIAL WIRE PORT CAST IRON VALVE BOX � VALVE BOX ALIGNMENT DEVICE LOCATOR (SEE NOTE #?) WIRE VALVE RISER PIPE PIPE PER APPROVED PLANS BAG OF CONCRETE MIX NOTES: i. WHEN TOP OF OPERATING NUT IS DEEPER THAN 30", A HIGH STRENGTH STEEL EXTENSION WILL BE REQUIRED TO BRING OPERATING NUT 24"-30" BELOW FINISHED GRADE, A STEEL CENTERING PLATE, WELDED TO THE EXTENSION. IS ALSO REQUIRED. 2. A VALVE BOX ALIGNMENT DEVICE SHALL BE PROVIDED TO ELIMINATE SHIFTING OF THE VALVE BOX AGAINST THE OPERATING NUT. 3. BOLT DOWN COVER SHALL BE USED IN ALL AREAS. 4. C900 P.V.C. RISER PIPE SHALL BE ADDED TO EXTEND THE VALVE BOX IF NEEDED. 5. RPM'S SHALL NOT BE INSTALLED IN CROSSWALKS OR PEDESTRIAN WALKWAYS. 8, THE TOP SIDE OF THE VALVE BOX COVER AND THE INSIDE OF TOP SECTION OF THE VALVE BOX SHALL BE PAINTED BLUE FOR WATER MAINS, GREEN FOR SEWER MAINS AND PURPLE FOR RECLAIMED WATER MAINS. MINIMUM CONSTRUCTION 3T4NOAR08 FOR DETAIL. 0.07 C:TY OF PORT BT, U.,., OgTE: 2015 ' 9009.E.OBDEN LHNE TYPICAL VALVE BOX AND COLLAR Panr 9r. LUCIE, FL a4ae9 ecALel Nas. PHONE (]73)8]Y6400 FAX 1]]2181J-8993 9NElT:1 OF 2 REDUCER L =RETRAINED LENGTH AT LARGER SIZE OF REDUCER (FEET) DIAMETER 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" 42" 48" 4" 29 52 71 89 105 121 736 151 779 217 253 285 318 6" 31 53 74 93 111 727 143 772 211 249 282 315 8" 29 54 76 96 174 131 763 204 243 277 310 10" 30 55 78 98 117 157 795 235 271 305 12" 3D 56 79 100 137 184 226 283 299 14" 30 56 79 120 171 216 255 292 18" 30 56 101 15$ 204 245 283 18" � 30 80 140 190 233 273 20" Sfi 127 175. 221. 263 24" 78 141 192 238 30" 78 140 194 36".. 75 139 42" 75 ' NOTES: 1. THE REQUIREMENTS SET FORTH ABOVE WERE CALCULATED FOR PVC PIPE BASED UPON THE FOLLOWING ASSUMPTIONS: -SOIL CONDITIONS SILTY SANG ISM) -TRENCH TYPE: 3 (PIPE BEDDEDIN d"MINIMUM OF LOOSE SOIL WITH BACKFILL LIGHTLY COMPACTED) -MINIMUM COVER:3 FT -SAFETY FACTOR: LS -TEST PRESSURE: 150 P51 2, IF FIELD CONDITIONS DIFFER FROM THE ABOVE. THE ENGINEEROF-RECORD(FORT SHALL SUBMIT CALCULATIONS BASED ON THE FIELD CONDITION FOR REVIEW AND APPROVAL OF PSLUSD. MIXIMVM CONSTRUCTION STANDARDS FOR DETAIL: O-Ca cr7r OF PORT ST. LuaE PIPELINE RESTRAINT DATE: 2013 voaia'r. rune �Figi49e9 El REQUIREMENTS (REDUCER) aegte: PHONE (T]2)8]a-6480 FAX (TNI eTYe43] aHEET: a OF 3 UTILITY MAINTAINED CUSTOMER MAINTAINED SEE TYPICAL VALVE POINT OF SERVICE (P.O.SJ ' BCK AND COLLAR DETECTOR METER DETAIL c-07 FROM MAIN TO CONSUMER PLAN VIEW all RESILIENT SEAT ' OS&Y GATE VALVE (ttP) TEST PORT (ttP) 90• (TYP) o Oo Y SEE NOTE 2 GRADE GRADE IN (1 4 REBAR 12' MIN. FINISH GRADE 8 24" MAX, MIN. 6" THICK CONCRETE (3,000 PSI) WITH 6X6 WIRE MESH ADJUSTABLE PIPE SUPPORTS RESTRAINED PIPE DEPTH VARIES30" MIN, PER DETAILS & ANCHORED TO PAP SPECIFICATIONS SEE DETAIL G-08 SIDE ELEVATION VIEW NOTES:. 1. ALL PIPE AND FITTINGS SHALL BE CLASS 53 DUCTILE IRON INCLUDING AND IN BETWEEN BURIED ELBOWS. 2, ALL UNDERGROUND FITTINGS SHALL BE RESTRAINED MECHANICAL JOINT TYPE &ALL ABOVE GROUND FITTINGS SHALL BE FLANGE JOINTS WITH FULL FACE NEOPRENE GASKETS, WITH STAINLESS STEEL BOLTS. Z. 'A 3/8" STAINLESS ' STEEL '. CHAIN &LOCK SHALL BE PROVIDED BY CONTRACTOR FOR THE VALVES AS REQUIRED 'BY THE PSLUSD, VALVES TO BE LOOKED L P N OPEN POSITION. ' 4, TO MAINTAIN CONTINUITY OF SERVICE DURING REPAIRS TO THE ASSEMBLY, AN ISOLATION VALVE SHALL BE:. PROVIDED ON THE. UTILITY'S MAIN AS SHOWN. 5, AT THE DIRECTION 'OF THE PSLUSD, BOLLARDS MAY BE REQUIRED 70 PREVENT DAMAGE FROM ACCIDENTS. REFER T0, DETAIL C-iS FOR, BOLLARD INSTALLATION. CITY POST ST. LUS I 8. A BRASS PLUG SHALL BE INSTALLED IN ALL TEST PORTS. MINIMUM CONSTRUCTION BTGNOaROS FOR DETAIL: W.O] 0008 QF OODEN LANE IE FIRE SERVICE DATE: 201E PORT BT. LUCIE FL 24982 BACKFLOW ASSEMBLY RCALE: N.T.S. PNONEIT]Y16]a.8400 FAX ITRI 9T]A9a3 SNEET:1 OF 1 FINISH COVER MARKED "PSL SEWER" MATCH GRADE AND PAINTED GREEN FINISH 6"MIN. I CONCRETE COLLAR SCREW CAP/PLUG ACCESS BOX AND COVER 6" RISER 6" 45' PVC ELBOW MARKER BALL 45' PVC WYE (SEE NOTE �J3) PVC PVC CAP AT NOTES: TERMINUS 1. AN ACCESS BOX AND COVER SHALL BE USED, 2. CLEANOUT ASSEMBLY SHALL BE INSTALLED AT A MAXIMUM 75' INTERVALS AND AT TERMINAL POINT OF THE PSLUSD RESPONSIBILTY. THE LOCATION SHALL BE IN ACCORDANCE WITH THE PSLUSD UTILITY STANDARDS. 3. MARKER BALL SHALL BE STRAPPED TO THE ELBOW, MINIMUM CONSTRUCTION STANDARDS FOR DETAIL: WW.BS CITY OF PORT BT. WCIE E 8068.F. ODDEN LgHF SANITARY SEWER CLEANOUT GATE: 2013 PORT ST. LUCIE, FL 96889 SCALE: N.T.S. PHONE (772) 879.8400 FAX (P318T18933 SHEET: , OF 1