Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE- HVAC LOAD CALCULATIONS�iCANNkQ 1. FORM'R405-2014 o�QPPP WE FLORIDA ENERGY EFFICICODE -FOR BUILDING CONSTRUCTION F76ilda Department of Business and-Profession6l'Regu�latioii - Residential Performance Method Project Name: Standard Pacific RB Stamford Lot 39 Builder Name: Standard Pacific Homes Street: - 3cy,- ( A�w f,.(c(,44_- - Permit Office: St. Lucie City, State, Zip: Port St. Lucie , FL, J Permit Number: Owner: Standard Pacific Homes Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (3971.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 3646.00 ft2 b. Frame -Wood, Adjacent R=11.0 325.43 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms •4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (3483.0 sqft.) Insulation Area a. Under Attic (Vented) R=38.0 3483.00 ft2 ' 6. Conditioned floor area above grade (ft2) 3483 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(508.6 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AC 1 First Floor 6 580 a. U-Factor: Dbl, U=1.07 335.58 ft2 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=1.05 80.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a. Central Unit 56.5 SEER:16.00 c. U-Factor: Dbl, U=1.00 68.99 ft2 SHGC: SHGC=0.32 .13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 24.00 ft2 a. Electric Heat Pump 57.0 HSPF:9.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 7.303 ft. Area Weighted Average SHGC: 0.296 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (3483.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 3483.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= 'ft2 15. Credits Pstat Total Proposed Modified Loads: 87.52 Glass/Floor Area: 0.146 PASS Total Baseline Loads: 97.63 I hereby certify that the plans and specifications covered by Review of the plans and 0IME S,a� this calculation are in compliance with the Florida Energy specifications covered by this 0 b _ . O Digitally signed by Chris wildroudt Code. DN: cn=Chris Wlldroudt, c=US, Chris calculation indicates compliance a f� o=En ineered Air, LLC, ou=New s with the Florida Ener Code. Energy l4 rr��,?�,, .,;,r .;; •, �� O Construction Sales and PREPARED BY: Before construction is completed • :. :v ,.nn -•- *1,j ..+ DATE: WAIrInn, lr�email=cfirisw(a)enaineeredairlic. this building will be inspected for ii -' ty Date: 2015.12.0314:12:51 -0600' compliance with Section 558.908 I hereby certify that this building, as •de ' ed, is in compliance Florida Statutes. with the Florida Energy Cade. f''Op WS OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factorysealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. ILE C 12/31.201 &2:10 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1• of 5 raneer�onn Dent A PROJECT Al VL Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Standard Pacific RB Stamford User Standard Pacific Homes I Standard Pacific Homes St. Lucie Single-family New (From Plans) Bedrooms,:-, R-,4 Conditioned Area: 3483, Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Lot Information. Lot # 39 BlocktSubDivislon: Riverbend PlatBook: Street: County: St. Lucie City, State, Zip: Port St. Lucie , FL, CLIMATE v Design Location TMY Site IECC Design Temp Zone 97.5% 2.5% Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL-ST-LUCIE-CO-INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume Blockl 3483 37334.9 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled . Heated I AC I First Floor 3483 37334.9 No 5 4 1 Yes Yes Yes FLOORS v# Floor Type Space Perimeter R-Value Area Tile Wood Carpet I Slab -On -Grade Edge Insulatio AC 1 First Floor 372 ft 0 3483 ft2 0 0 ROOF V # Type Materials Roof Gable Roof Area Area Color Solar Absor. SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) I Hip Barrel tile 3773 ft2 0 ft2 Light 0.6 No 0.75 No 38 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC I Full attic Vented 150 3483 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) AC 1 First Floor 38 3483 ft2 0.11 Wood 1213/20152:10PM I. EnergyGauge@ USA- FlaRbs2014 Section R405-4-1 Compliant Software Page 2 of 5 FORM R40572014 ..--. WALLS Adjapent y;,,,Gauity,t.._ Width Height ;z Sheathing Framing; ;,,Solar fBelgyy�,G jace' Wall Type o _ 1 E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 13 0 10.67 0 138.7 ft2 0.4 0 0.4 0 2 E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 10 0 10.67 0 106.7 ft2 0.4 0 0.4 0 _ 3 E Exterior Concrete Block - Int InsAC 1 First Flo : 4.1 13 0 10.67 0 138J ft2 0.4 0 0.4 0 _ 4 E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 12 0 10.67 0 128.0 ft2 0.4 0 0.4 0 _ 5 S Exterior Concrete Block - Int InsAC 1 First Flo 4.1 80 0 10.67 0 853.6 ft2 0.4 0 0.4 0 _ 6 S Exterior Concrete Block - Int InsAC 1 First Flo 4.1 13.5 0 10.67 0 144.0 ft2 0.4 0 0.4 0 7 W Exterior Concrete Block - Int InsAC 1 First Flo 4.1 34 0 10.67 0 362.8 ft2 0.4 0 0.4 0 8 W Exterior, Concrete Block - Int lnsAC 1 First Flo 4.1 20 0 12.67 0 253.4 ft2 0.4 0 0.4 0 9 N Exterior Concrete Block - Int InsAC 1 First Flo 4.1 14 0 10.67 0 149.4 ft2 0.4 0 0.4 0 10 N Exterior Concrete Block - Int InsAC 1 First Flo 4.1 24 0 10.67 0 256.112 0.4 0 0.4 0 _ 11 N Garage Frame - Wood AC 1 First Flo 11 8 0 10.67 0 85.4 ft2 0.4 0.4 0 _ 12 W Garage Frame - Wood AC 1 First Flo 11 6 0 10.67 0 64.0 ft2 0.4 0.4 0 13 W Exterior Concrete Block - Int InsAC 1 First Flo 4.1 18 0 10.67 0 192.1 ft2 0.4 0 0.4 0 14 N Exterior Concrete Block - Int InsAC 1 First Flo 4.1 50 0 10.67 0 533.5 ft2 0.4 0 0.4 0 15 S Exterior Concrete Block - Int InsAC 1 First Flo 4.1 6 0 10.67 0 64.0 ft2 0.4 0 0.4 0 16 E Garage Frame - Wood AC 1 First Flo 11 16.5 0 10.67 0 176.1 ft2 0.4 0.4 0 17 S Exterior Concrete Block - Int InsAC 1 First Flo 4.1 12 0 10 0 .120.0 ft2 0.4 0 0.4 0 18 E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 20.5 0 10 0 205.0 ft2 0.4 0 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated AC 1 First Flo None .6 2.7 8 21.4 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Double Yes 1 0.32 21.3 ft2 23 ft 0 in 2 ft 0 in None None 2 E 2 Metal Low-E Double Yes 0.77 0.22 24.0 ft2 13 ft 0 in 2 ft 0 in None. None 3 E 3 Metal Low-E Double Yes 1.07 0.3 16.2 ft2 6 ft 0 in 2 ft 0 in None None 4 S 5 Metal Low-E Double Yes 1.07 0.3 58.5 ft2 2 ft 0 in 2 ft 0 in None None 5 S 5 Metal Low-E Double Yes 1.07 0.3 22.7 ft2 2 ft 0 in 2 ft 0 in None None 6 S 5 Metal Low-E Double Yes 1.07 0.3 9.2 ft2 2 ft 0 in 2 ft 0 in None None 7 S 6 Metal Low-E Double Yes 1.05 0.28 8b.0 ft2 18 ft 0 in 2 it 0 in None None 8 W 7 Metal Low-E Double Yes 1.07 0.3 58.5 ft2 2 ft 0 in 2 ft 0 in None None 9 W 8 Metal Low-E Double Yes 1 0.32 24.9 ft2 12 ft 0 in 1 it 0 in. None None 10 N 10 Metal Low-E Double Yes 1.07 0.3 22.7 ft2 9 ft 0 in 2 ft 0 in None None 11 W 13 Metal Low-E Double Yes 1.07 0.3 58.5 ft2 6 ft 0 in 2 ft 0 in None None 12 N 14 Metal Low-E Double Yes 1.07 0.3 27.3 ft2 2 ft 0 in 2 ft 0 in None None 13 N 14 Metal Low-E Double Yes 1.07 0.3 19.5 ft2 2 ft 0 in 2 ft 0 in None None 14 N 14 Metal Low-E Double Yes 1.07 0.3 9.2 ft2 2 ft 0 in 2 ft 0 in None None 15 N 14 Metal Low-E Double Yes 1 0.32 16.2 ft2 2 ft 0 in 2 ft 0 in None None 16 N 14 Metal Low-E Double Yes 1 0.32 6.7 ft2 2 ft 0 in 2 ft 0 in None None 12/3/2015 2:10 PM I. EnergyGaugeB USA « FlaRes2014 Section R405,4.1 Compliant, Software Page 3 of 5 cnonn DAr1r;_')nIn WINDOWS Orientation shown is the entered, Proposed orientation.. • • V, All / �/ # Wall �. _,...v .. s Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 17 18 S 15 Metal Low-E Double Yes S 17 Metal Low-E Double Yes 1.07 0.3 13.7 ft2 2 ft 0 in 2 ft 0 in None 1.07 0.3 19.7 ft2 2 ft 0 in 1 ft 0 in None None None GARAGE # Floor Area Ceiling Area. Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 660 ft2 660 ft2 72 ft loft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000341 3111.2 170.8 321.22 .2486 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:9 57 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 56.5 kBtu/hr 1900 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type •SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V # — Supply --- Location R-Value Area Return -- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT . OUT QN RLF HVAC # Heat Cool 1 Attic 6 580 ft2 Attic 160 ft2 Default Leakage AC 1 First F (Default) (Default) 1 1 G 12/3/2015 2:100M EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 e TEMPERATURES �Programable Thermostat: Y Ceiling Fans: Coolin [[ ]]Jan j Feb [ ]Mar [ ] A r [ ] Ma [X] Jun [X] Jul [X] Au Se f Oct [ j Nov Dec Heating [X] JanFeb [X) Mar [ ]Apr [ ] May [ ] Jun [ ] Jul [ ] Aug Sep rj Oct [X] Nov X Dec Ventin [[ ]] Jan [ l Feb [X] Mar [X] A r [ 1 Ma [ ]Jun [ ]Jul [ ] Au Se [X Oct [Xl Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78' 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH) AM PM 66 68 6 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 8 68 68 66 68 66 1t2/3/2015 2:10 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software I .. ' . Page 5 of 5 FORM R4,95-2014 ENERGY LEVEL ,PERFORMANCE .(EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 90 The lower the EnergyPerformance Index, the more efficient the home. Port St. Lucie; FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 3646.00 ftz b. Frame - Wood, Adjacent R=11.0 325.43 ft 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 4 d. N/A R= ftZ 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=38.0 3483.00 ftZ 6. Conditioned floor area (ftZ) 3483 b. NIA R= ftZ c. NIA R= ft 7. Windows- Description Area 11. Ducts z R ft a. U-Factor: Dbl, U=1.07 335.58 ftZ a. Sup: Attic, Ret: Attic, AH: AC 1 First Floor 6 580 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=1.05 80.00 ftZ SHGC: SHGC=0.28 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=1.00 68.99 ftZ a. Central Unit 56.5 SEER:16.00 SHGC: SHGC=0.32 d. U-Factor: other (see details) 24.00 ftZ 13. Heating systems kBtu/hr Efficiency SHGC: other (see details) a. Electric Heat Pump 57.0 HSPF:9.00 Area Weighted Average Overhang Depth: 7.303 ft. Area Weighted Average SHGC: 0.296 8. Floor Types Insulation Area 14. Hot water systems Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 3483.00 ftZ a. Electric EF: 0.94 b. N/A R= ftZ b. Conservation features c. N/A R= ftZ None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed 4° based on installed Code compliant features. ti Builder Signature: Date: I ( - Address of New Home: to �IlI��, City/FL Zip: 3�i53 �D WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating.. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303,1.3 of the Florida Building Code, Energy Co RIE if : t 12/3/2015 2:11 PM EnergyGauge® USA- FlaRes2014 - Section R405.4.1 Compliant Software - page 1 of 1 Stamford Model HVAC Load Calculations for Standard Pacific Homes VAHV Rhvac is an ACCA approved Manual J and Manual b computer program. Calculations are perform6d. per ACCA Manual J 8fh Edition, Version 2, and Prepared By: Chris Wildroudt Engineered Air LLC CACO45860 2520 N Andrews Ave Ext Pompano Beach, FL 33064 954 974-7277 Monday, February 10, 2014 T COPY ACCA Ma a Rhvac - Residential & Litipt COmrrier0lal'FIVAC Loads-'' ' "", ,i? Elite'Softw_a_ r_e bevelbpment; Engineered Air, LLC ' Stamford Model. Mar at@;,FL 33063. �G ` Pa e2 Pro'ect Report ;General�Proe_ct_Informatlon ,.`;_ _ - - _ • Project Title: Stamford Model Designed By: Chris Wildroudt Project Date: 2-10-14 Client Name: Standard Pacific Homes Company Name: Engineered Air LLC CACO45860 Company Representative: Chris Wildroudt Company Address: 2520 N Andrews Ave Ext Company City: Pompano Beach, FL 33064 Company Phone: 954 974-7277 Company Fax: 954 973-1883 `04 KQata' Reference City: Fort Pierce, Florida Building Orientation: House faces East Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 75 50% 50% 75 42 Total Building Supply CFM: 1,965 CFM Per Square ft.: 0.564 Square ft. of Room Area: 3,483 Square ft. Per Ton: 831 Volume (ft3) of Cond. Space: 35,411 Total Heating Required Including Ventilation Air: 50,280 Btuh 50.280 MBH Total Sensible Gain: 43,180 Btuh 86 % Total Latent Gain: 7,134 Btuh '14 % Total Cooling Required Including Ventilation Air: 50,314 Btuh 4.19 Tons (Based On Sensible + Latent) Notes . Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Riverbend Stamford.rh9 Monday, February 10, 2014, 1:50 PM hXac_- Resideritial & Light Comm'ercial HVAC loads' ' (.^' , : °:E E1jte Software DevelopmenE; dnc: 1. ngineered Air LLC • .� Stamford .Model ; ar ate, FL 33063: Pa g a 3. 1. Tota'i~Building Summary Loads Com orient . = • - ... P - Area Sena Lat ;'Seri. Total. Descn`'tion. :._.. ' . : '. Quarr Loss __ Gain . ' .Gaini .' Gain, Lo-E French Door: Glazing-Low-E French Door, u-value 96 2,068 0 1,552 1,552 0.77, SHGC 0.22 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 46.2. 518 0 578 578 0.4, SHGC 0.31 Lo-E operable: Glazing-Low-E Operable Glass, u-value 155.8 2,622 0 5,308 5,308 0.6, SHGC 0.31 Lo-E French Door: Glazing-Low-E French Door, u-value 40 862 0 924 924 0.77, SHGC 0.22 Lo-E operable: Glazing-Low-E Operable Glass, u-value 316.2 5,319 0 6,275 6,275 0.6, SHGC 0.31 Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value 288 4,760 0 5,532 5,532 0.59, SHGC 0.32 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 22.8 256 0 286 286 0.4, SHGC 0.31 11J: Door -Metal - Fiberglass Core 21.4 192 0 192 192 13A-4ocs: Wall -Block, board insulation only, R-4 board 2476 9,915 0 5,417 5,417 insulation, open core, siding finish 12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud 304.1 311 0 311 311 cavity, no board insulation, brick finish, wood studs 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud 205 298 0 298 298 cavity, no board insulation, siding finish, wood studs 16D-30: Roof/Ceiling-Under Attic with Insulation on Attic 3482.9 3,121 0 3,344 3,344 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-30 insulation 22A-pl: Floor -Slab on grade, No edge insulation, no 372 10,302 0 0 0 insulation below floor, any floor cover, passive, light dry soil Subtotals for structure: 40,544 0 30,017� 30,017 People: 5 1,500 1,400 2,900 Equipment: 2,000 2,400 4,400 Lighting: 0 0 0 Ductwork: 3,017 428 2,591 3,019 Infiltration: Winter CFM: 218, Summer CFM: 112 6,719 3,206 1,848 5,054 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 4,924 Total Building Load Totals_ 50,280 _ _ 7,134 _4,924 43,180 50,314 Total Building Supply CFM: 1,965 CFM Per Square ft.: 0.564 Square ft. of Room Area: 3,483 Square ft. Per Ton: 831 Volume (ft) of Cond. Space: 35,411 Total Heating Required Including Ventilation Air: 50,280 Btuh 50.280 MBH Total Sensible Gain: 43,180 Btuh 86 % Total Latent Gain: 7,134 Btuh 14 % Total Cooling Required Including Ventilation'Air: 50,314 Btuh 4.19 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. EJe sure to select a unit that meets both sensible and latent loads 9bcording to the manufacturer`s performance data at intent your design conditions. S:\NEW CONSTRUCTION\Chris Elite Fiiles\Stan Pac Riverbend Stamford.rh9 Monday, February, 10, 2014, 1:50 PM �R V�a! Residential & Light Commercial YAGLgad rcialj, � n� re, 'Air LLC EIR4,SoftWpre Dpvq!9Pn�!q0;11nc,. S1�6fbrd Mq'deif �6 M =b a r ate, FL 83063 Page System I A C I -First Flo -or Summary Loads 7- :Component', en, S, Total. 'etcx On, Gain:...Gain Lo-E French Door: Glazing-Low-E French Door, u-value 96 2,068 0 1,552 1,552 0.77, SHGC 0.22 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 46.2 518 0 578 578 0.4, SHGC 0.31 Lo-E operable: Glazing-Low-E Operable Glass, u-value 155.8 2,622 0 5,308 5,308 0.6, SHGC 0.31 Lo-E French Door: Glazing-Low-E French Door, u-value 40 862 0 924 924 0.77, SHGC 0.22 Lo-E operable: Glazing-Low-E Operable Glass, u-value 316.2 5,319 0 6,275 6,275 0.6, SHGC 0.31 Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value 288 4,760 0 5,532 5,532 0.59, SHGC 0.32 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 22.8 256 0 286 286 0.4, SHGC 0.31 11 J: Door -Metal - Fiberglass Core 21.4 192 0 192 192 13A-4ocs: Wall -Block, board insulation only, R-4 board 2476 9,915 0 5,417 5,417 insulation, open core, siding finish 12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud 304.1 311 0 311 311 cavity, no board insulation, brick finish, wood studs 1213-0sw: Part -Frame, R-1 I insulation in 2 x 4 stud 205 298 0 298 298 cavity, no board insulation, siding finish, wood studs 16D-30: Roof/Ceiling-Under Attic with Insulation on Attic 3482.9 3,121 0 3,344 3,344 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-30 insulation 22A-pl: Floor -Slab on grade, No edge insulation, no 372 10,302 0 0 0 insulation below floor, any floor cover, passive, light dry soil Subtotals for structure: 40,544 0 30,017 30,017 People: 5 1,500 1,400 2,900 Equipment: 2,000 2,400 4,400 Lighting: 0 0 0 Ductwork: 3,017 428 2,591 3,019 Infiltration: Winter CFM: 218, Summer CFM: 112 6,719 3,206 1,848 5,054 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 .0 0 AED Excursion: 0 0 4,924 4,924 System 1 AC 1 - First Floor Load TOWS: Y 50,280 7,134 43,180 50,314 Check Supply CFM: 1,965 CFM Per Square ft.:. 0.564 Square ft. of Room Area: 3,483 Square ft. Per Ton: 831 Volume (fl:3) of Cond. Space: 35,411 Total Heating Required Including Ventilation Air: 50,280 Btuh 50.280 MBH Total Sensible Gain: 43,180 Btuh 86 % Total Latent Gain: 7,134 Btuh 14 % Total Cooling Required Including Ventilation Air: 50,314 Btuh 4.19 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as,building use and weather may vary. mBe);sureto-select a unit that meets both sensible and latent loads-orwoixiingj.torthe •manufacturer's performance data at your design conditions. &\NEW'CONSTRUCTION\Chrisi Elite.Files\Stan Pac Riverbend Stamford.rh9 Monday, February 10, 2014, 1:50 PM