HomeMy WebLinkAboutENERGY EFFICIENCY CODE- HVAC LOAD CALCULATIONS�iCANNkQ
1. FORM'R405-2014 o�QPPP WE
FLORIDA ENERGY EFFICICODE -FOR BUILDING CONSTRUCTION
F76ilda Department of Business and-Profession6l'Regu�latioii - Residential Performance Method
Project Name: Standard Pacific RB Stamford Lot 39
Builder Name: Standard Pacific Homes
Street: - 3cy,- ( A�w f,.(c(,44_- -
Permit Office: St. Lucie
City, State, Zip: Port St. Lucie , FL, J
Permit Number:
Owner: Standard Pacific Homes
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (3971.5 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 3646.00 ft2
b. Frame -Wood, Adjacent
R=11.0 325.43 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms •4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (3483.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=38.0 3483.00 ft2
' 6. Conditioned floor area above grade (ft2) 3483
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(508.6 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AC 1 First Floor 6 580
a. U-Factor: Dbl, U=1.07 335.58 ft2
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=1.05 80.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.28
a. Central Unit
56.5 SEER:16.00
c. U-Factor: Dbl, U=1.00 68.99 ft2
SHGC: SHGC=0.32
.13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 24.00 ft2
a. Electric Heat Pump
57.0 HSPF:9.00
SHGC: other (see details)
Area Weighted Average Overhang Depth: 7.303 ft.
Area Weighted Average SHGC: 0.296
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (3483.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 3483.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= 'ft2
15. Credits
Pstat
Total Proposed Modified Loads: 87.52
Glass/Floor Area: 0.146
PASS
Total Baseline Loads: 97.63
I hereby certify that the plans and specifications covered by
Review of the plans and
0IME S,a�
this calculation are in compliance with the Florida Energy
specifications covered by this
0
b _ . O
Digitally signed by Chris wildroudt
Code. DN: cn=Chris Wlldroudt, c=US,
Chris
calculation indicates compliance
a f�
o=En ineered Air, LLC, ou=New
s
with the Florida Ener Code.
Energy
l4 rr��,?�,, .,;,r .;; •, �� O
Construction Sales and
PREPARED BY:
Before construction is completed •
:. :v ,.nn -•- *1,j
..+
DATE: WAIrInn, lr�email=cfirisw(a)enaineeredairlic.
this building will be inspected for
ii -' ty
Date: 2015.12.0314:12:51 -0600'
compliance with Section 558.908
I hereby certify that this building, as •de ' ed, is in compliance
Florida Statutes.
with the Florida Energy Cade.
f''Op WS
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factorysealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
ILE C
12/31.201 &2:10 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1• of 5
raneer�onn Dent
A
PROJECT
Al
VL
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Standard Pacific RB Stamford
User
Standard Pacific Homes
I
Standard Pacific Homes
St. Lucie
Single-family
New (From Plans)
Bedrooms,:-, R-,4
Conditioned Area: 3483,
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type: Lot Information.
Lot # 39
BlocktSubDivislon: Riverbend
PlatBook:
Street:
County: St. Lucie
City, State, Zip: Port St. Lucie ,
FL,
CLIMATE
v Design Location TMY Site
IECC Design Temp
Zone 97.5% 2.5%
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL-ST-LUCIE-CO-INTL 2 39 90
70
75 722 62 Low
BLOCKS
Number
Name Area
Volume
Blockl 3483
37334.9
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled . Heated
I
AC I First Floor 3483
37334.9 No 5
4
1 Yes Yes Yes
FLOORS
v#
Floor Type Space
Perimeter R-Value
Area
Tile Wood Carpet
I Slab -On -Grade Edge Insulatio AC 1 First Floor 372 ft 0
3483 ft2
0 0
ROOF
V #
Type Materials
Roof Gable Roof
Area Area Color
Solar
Absor.
SA Emitt Emitt Deck Pitch
Tested Tested Insul. (deg)
I
Hip Barrel tile
3773 ft2 0 ft2 Light
0.6
No 0.75 No 38 22.6
ATTIC
V #
Type Ventilation Vent Ratio (1 in)
Area
RBS IRCC
I
Full attic Vented 150
3483 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac Truss Type
1
Under Attic (Vented) AC 1 First Floor 38 3483 ft2
0.11 Wood
1213/20152:10PM
I.
EnergyGauge@ USA- FlaRbs2014 Section R405-4-1 Compliant Software
Page 2 of 5
FORM R40572014 ..--.
WALLS
Adjapent y;,,,Gauity,t.._
Width Height
;z
Sheathing
Framing; ;,,Solar
fBelgyy�,G
jace'
Wall Type
o
_ 1
E
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
13
0 10.67 0
138.7 ft2
0.4
0
0.4
0
2
E
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
10
0 10.67 0
106.7 ft2
0.4
0
0.4
0
_ 3
E
Exterior
Concrete Block - Int InsAC 1 First Flo
: 4.1
13
0 10.67 0
138J ft2
0.4
0
0.4
0
_ 4
E
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
12
0 10.67 0
128.0 ft2
0.4
0
0.4
0
_ 5
S
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
80
0 10.67 0
853.6 ft2
0.4
0
0.4
0
_ 6
S
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
13.5
0 10.67 0
144.0 ft2
0.4
0
0.4
0
7
W
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
34
0 10.67 0
362.8 ft2
0.4
0
0.4
0
8
W
Exterior,
Concrete Block - Int lnsAC 1 First Flo
4.1
20
0 12.67 0
253.4 ft2
0.4
0
0.4
0
9
N
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
14
0 10.67 0
149.4 ft2
0.4
0
0.4
0
10
N
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
24
0 10.67 0
256.112
0.4
0
0.4
0
_ 11
N
Garage
Frame - Wood AC 1 First Flo
11
8
0 10.67 0
85.4 ft2
0.4
0.4
0
_ 12
W
Garage
Frame - Wood AC 1 First Flo
11
6
0 10.67 0
64.0 ft2
0.4
0.4
0
13
W
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
18
0 10.67 0
192.1 ft2
0.4
0
0.4
0
14
N
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
50
0 10.67 0
533.5 ft2
0.4
0
0.4
0
15
S
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
6
0 10.67 0
64.0 ft2
0.4
0
0.4
0
16
E
Garage
Frame - Wood AC 1 First Flo
11
16.5
0 10.67 0
176.1 ft2
0.4
0.4
0
17
S
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
12
0 10 0
.120.0 ft2
0.4
0
0.4
0
18
E
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
20.5
0 10 0
205.0 ft2
0.4
0
0.4
0
DOORS
#
Ornt
Door Type Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated AC 1 First Flo
None .6
2.7
8
21.4 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Area
Depth
Separation
Int Shade
Screening
1
E 1
Metal Low-E Double Yes
1
0.32
21.3 ft2
23 ft 0 in
2 ft 0 in
None
None
2
E 2
Metal Low-E Double Yes
0.77
0.22
24.0 ft2
13 ft 0 in
2 ft 0 in
None.
None
3
E 3
Metal Low-E Double Yes
1.07
0.3
16.2 ft2
6 ft 0 in
2 ft 0 in
None
None
4
S 5
Metal Low-E Double Yes
1.07
0.3
58.5 ft2
2 ft 0 in
2 ft 0 in
None
None
5
S 5
Metal Low-E Double Yes
1.07
0.3
22.7 ft2
2 ft 0 in
2 ft 0 in
None
None
6
S 5
Metal Low-E Double Yes
1.07
0.3
9.2 ft2
2 ft 0 in
2 ft 0 in
None
None
7
S 6
Metal Low-E Double Yes
1.05
0.28
8b.0 ft2
18 ft 0 in
2 it 0 in
None
None
8
W 7
Metal Low-E Double Yes
1.07
0.3
58.5 ft2
2 ft 0 in
2 ft 0 in
None
None
9
W 8
Metal Low-E Double Yes
1
0.32
24.9 ft2
12 ft 0 in
1 it 0 in.
None
None
10
N 10
Metal Low-E Double Yes
1.07
0.3
22.7 ft2
9 ft 0 in
2 ft 0 in
None
None
11
W 13
Metal Low-E Double Yes
1.07
0.3
58.5 ft2
6 ft 0 in
2 ft 0 in
None
None
12
N 14
Metal Low-E Double Yes
1.07
0.3
27.3 ft2
2 ft 0 in
2 ft 0 in
None
None
13
N 14
Metal Low-E Double Yes
1.07
0.3
19.5 ft2
2 ft 0 in
2 ft 0 in
None
None
14
N 14
Metal Low-E Double Yes
1.07
0.3
9.2 ft2
2 ft 0 in
2 ft 0 in
None
None
15
N 14
Metal Low-E Double Yes
1
0.32
16.2 ft2
2 ft 0 in
2 ft 0 in
None
None
16
N 14
Metal Low-E Double Yes
1
0.32
6.7 ft2
2 ft 0 in
2 ft 0 in
None
None
12/3/2015 2:10 PM I. EnergyGaugeB USA « FlaRes2014 Section R405,4.1 Compliant, Software Page 3 of 5
cnonn DAr1r;_')nIn
WINDOWS
Orientation shown is the entered, Proposed orientation.. • •
V,
All
/
�/ #
Wall �. _,...v .. s Overhang
Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
17
18
S 15 Metal Low-E Double Yes
S 17 Metal Low-E Double Yes
1.07 0.3 13.7 ft2 2 ft 0 in 2 ft 0 in None
1.07 0.3 19.7 ft2 2 ft 0 in 1 ft 0 in None
None
None
GARAGE
#
Floor Area Ceiling Area.
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
660 ft2
660 ft2
72 ft loft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000341
3111.2 170.8 321.22 .2486 5
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Heat Pump
Split
HSPF:9 57 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit
Split
SEER: 16 56.5 kBtu/hr 1900 cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type •SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.94 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
V #
— Supply ---
Location R-Value Area
Return -- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT . OUT QN RLF
HVAC #
Heat Cool
1
Attic 6 580 ft2
Attic
160 ft2 Default Leakage AC 1 First F (Default) (Default)
1 1
G 12/3/2015 2:100M EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
e
TEMPERATURES
�Programable Thermostat: Y
Ceiling Fans:
Coolin [[ ]]Jan
j Feb
[ ]Mar
[
] A r [
] Ma [X]
Jun
[X] Jul
[X] Au
Se
f
Oct
[ j Nov
Dec
Heating [X] JanFeb
[X) Mar
[
]Apr [
] May [
] Jun
[ ] Jul
[ ] Aug
Sep
rj
Oct
[X] Nov
X Dec
Ventin [[ ]] Jan
[ l Feb
[X] Mar
[X]
A r [
1 Ma [
]Jun
[ ]Jul
[ ] Au
Se
[X
Oct
[Xl Nov
[ Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78'
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
66
68
66
Heating (WEH)
AM
PM
66
68
6
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
8
68
68
66
68
66
1t2/3/2015 2:10 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software I .. ' . Page 5 of 5
FORM R4,95-2014
ENERGY
LEVEL
,PERFORMANCE
.(EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 90
The lower the EnergyPerformance Index, the more efficient the home.
Port St. Lucie; FL,
1. New construction or existing
New (From Plans) 9. Wall Types Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Int Insul, Exterior R=4.1
3646.00 ftz
b. Frame - Wood, Adjacent R=11.0
325.43 ft
3. Number of units, if multiple family
1 c. NIA R=
ft2
4. Number of Bedrooms
4 d. N/A R=
ftZ
10. Ceiling Types Insulation
Area
5. Is this a worst case?
No a. Under Attic (Vented) R=38.0
3483.00 ftZ
6. Conditioned floor area (ftZ)
3483 b. NIA R=
ftZ
c. NIA R=
ft
7. Windows- Description
Area
11. Ducts
z
R ft
a. U-Factor: Dbl, U=1.07
335.58 ftZ a. Sup: Attic, Ret: Attic, AH: AC 1 First Floor
6 580
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=1.05
80.00 ftZ
SHGC: SHGC=0.28
12. Cooling systems kBtu/hr
Efficiency
c. U-Factor: Dbl, U=1.00
68.99 ftZ a. Central Unit 56.5
SEER:16.00
SHGC: SHGC=0.32
d. U-Factor: other (see details)
24.00 ftZ 13. Heating systems kBtu/hr
Efficiency
SHGC: other (see details)
a. Electric Heat Pump 57.0
HSPF:9.00
Area Weighted Average Overhang Depth:
7.303 ft.
Area Weighted Average SHGC:
0.296
8. Floor Types Insulation Area 14. Hot water systems Cap:
50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 3483.00 ftZ a. Electric
EF: 0.94
b. N/A R=
ftZ
b. Conservation features
c. N/A R=
ftZ
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed 4°
based on installed Code compliant features. ti
Builder Signature: Date: I ( -
Address of New Home: to �IlI��, City/FL Zip:
3�i53
�D WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating.. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section R303,1.3 of the Florida Building Code, Energy Co RIE
if : t
12/3/2015 2:11 PM EnergyGauge® USA- FlaRes2014 - Section R405.4.1 Compliant Software - page 1 of 1
Stamford Model
HVAC Load Calculations
for
Standard Pacific Homes
VAHV
Rhvac is an ACCA approved Manual J and Manual b computer program.
Calculations are perform6d. per ACCA Manual J 8fh Edition, Version 2, and
Prepared By:
Chris Wildroudt
Engineered Air LLC CACO45860
2520 N Andrews Ave Ext
Pompano Beach, FL 33064
954 974-7277
Monday, February 10, 2014
T COPY
ACCA Ma a
Rhvac - Residential & Litipt COmrrier0lal'FIVAC Loads-'' ' "",
,i? Elite'Softw_a_ r_e bevelbpment;
Engineered Air, LLC
'
Stamford Model.
Mar at@;,FL 33063.
�G
` Pa e2
Pro'ect Report
;General�Proe_ct_Informatlon ,.`;_ _ - - _ •
Project Title: Stamford Model
Designed By: Chris Wildroudt
Project Date: 2-10-14
Client Name: Standard Pacific Homes
Company Name: Engineered Air LLC CACO45860
Company Representative: Chris Wildroudt
Company Address: 2520 N Andrews Ave Ext
Company City: Pompano Beach, FL 33064
Company Phone: 954 974-7277
Company Fax: 954 973-1883
`04 KQata'
Reference City: Fort Pierce, Florida
Building Orientation: House faces East
Daily Temperature Range: Medium
Latitude: 27 Degrees
Elevation: 25 ft.
Altitude Factor: 0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 42 39.4 n/a n/a 70 n/a
Summer: 90 75 50% 50% 75 42
Total Building Supply CFM: 1,965 CFM Per Square ft.: 0.564
Square ft. of Room Area: 3,483 Square ft. Per Ton: 831
Volume (ft3) of Cond. Space: 35,411
Total Heating Required Including Ventilation Air: 50,280 Btuh 50.280 MBH
Total Sensible Gain: 43,180 Btuh 86 %
Total Latent Gain: 7,134 Btuh '14 %
Total Cooling Required Including Ventilation Air: 50,314 Btuh 4.19 Tons (Based On Sensible + Latent)
Notes .
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Riverbend Stamford.rh9 Monday, February 10, 2014, 1:50 PM
hXac_- Resideritial & Light Comm'ercial HVAC loads' ' (.^' , : °:E
E1jte Software DevelopmenE; dnc: 1.
ngineered Air LLC •
.�
Stamford .Model ;
ar ate, FL 33063:
Pa g a 3. 1.
Tota'i~Building Summary Loads
Com orient . = • - ...
P -
Area
Sena
Lat
;'Seri.
Total.
Descn`'tion. :._.. ' .
: '. Quarr
Loss __
Gain .
' .Gaini .'
Gain,
Lo-E French Door: Glazing-Low-E French Door, u-value
96
2,068
0
1,552
1,552
0.77, SHGC 0.22
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
46.2.
518
0
578
578
0.4, SHGC 0.31
Lo-E operable: Glazing-Low-E Operable Glass, u-value
155.8
2,622
0
5,308
5,308
0.6, SHGC 0.31
Lo-E French Door: Glazing-Low-E French Door, u-value
40
862
0
924
924
0.77, SHGC 0.22
Lo-E operable: Glazing-Low-E Operable Glass, u-value
316.2
5,319
0
6,275
6,275
0.6, SHGC 0.31
Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value
288
4,760
0
5,532
5,532
0.59, SHGC 0.32
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
22.8
256
0
286
286
0.4, SHGC 0.31
11J: Door -Metal - Fiberglass Core
21.4
192
0
192
192
13A-4ocs: Wall -Block, board insulation only, R-4 board
2476
9,915
0
5,417
5,417
insulation, open core, siding finish
12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud
304.1
311
0
311
311
cavity, no board insulation, brick finish, wood studs
12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud
205
298
0
298
298
cavity, no board insulation, siding finish, wood studs
16D-30: Roof/Ceiling-Under Attic with Insulation on Attic
3482.9
3,121
0
3,344
3,344
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation
22A-pl: Floor -Slab on grade, No edge insulation, no
372
10,302
0
0
0
insulation below floor, any floor cover, passive, light
dry soil
Subtotals for structure:
40,544
0
30,017�
30,017
People:
5
1,500
1,400
2,900
Equipment:
2,000
2,400
4,400
Lighting:
0
0
0
Ductwork:
3,017
428
2,591
3,019
Infiltration: Winter CFM: 218, Summer CFM: 112
6,719
3,206
1,848
5,054
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
AED Excursion:
0
0
4,924
Total Building Load Totals_
50,280
_ _
7,134
_4,924
43,180
50,314
Total Building Supply CFM: 1,965
CFM Per Square ft.:
0.564
Square ft. of Room Area: 3,483
Square ft.
Per Ton:
831
Volume (ft) of Cond. Space: 35,411
Total Heating Required Including Ventilation Air:
50,280 Btuh
50.280
MBH
Total Sensible Gain:
43,180 Btuh
86
%
Total Latent Gain:
7,134 Btuh
14
%
Total Cooling Required Including Ventilation'Air:
50,314 Btuh
4.19
Tons (Based On Sensible + Latent)
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
EJe sure to select a unit that meets both sensible and latent loads 9bcording to the manufacturer`s
performance data at intent
your design conditions.
S:\NEW CONSTRUCTION\Chris Elite Fiiles\Stan Pac Riverbend Stamford.rh9 Monday, February, 10, 2014, 1:50 PM
�R V�a! Residential & Light Commercial YAGLgad
rcialj,
� n� re, 'Air LLC
EIR4,SoftWpre Dpvq!9Pn�!q0;11nc,.
S1�6fbrd Mq'deif
�6
M =b
a r ate, FL 83063
Page
System I A C I -First Flo -or Summary
Loads
7-
:Component',
en,
S,
Total.
'etcx On,
Gain:...Gain
Lo-E French Door: Glazing-Low-E French Door, u-value
96
2,068
0
1,552
1,552
0.77, SHGC 0.22
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
46.2
518
0
578
578
0.4, SHGC 0.31
Lo-E operable: Glazing-Low-E Operable Glass, u-value
155.8
2,622
0
5,308
5,308
0.6, SHGC 0.31
Lo-E French Door: Glazing-Low-E French Door, u-value
40
862
0
924
924
0.77, SHGC 0.22
Lo-E operable: Glazing-Low-E Operable Glass, u-value
316.2
5,319
0
6,275
6,275
0.6, SHGC 0.31
Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value
288
4,760
0
5,532
5,532
0.59, SHGC 0.32
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
22.8
256
0
286
286
0.4, SHGC 0.31
11 J: Door -Metal - Fiberglass Core
21.4
192
0
192
192
13A-4ocs: Wall -Block, board insulation only, R-4 board
2476
9,915
0
5,417
5,417
insulation, open core, siding finish
12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud
304.1
311
0
311
311
cavity, no board insulation, brick finish, wood studs
1213-0sw: Part -Frame, R-1 I insulation in 2 x 4 stud
205
298
0
298
298
cavity, no board insulation, siding finish, wood studs
16D-30: Roof/Ceiling-Under Attic with Insulation on Attic
3482.9
3,121
0
3,344
3,344
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation
22A-pl: Floor -Slab on grade, No edge insulation, no
372
10,302
0
0
0
insulation below floor, any floor cover, passive, light
dry soil
Subtotals for structure:
40,544
0
30,017
30,017
People:
5
1,500
1,400
2,900
Equipment:
2,000
2,400
4,400
Lighting:
0
0
0
Ductwork:
3,017
428
2,591
3,019
Infiltration: Winter CFM: 218, Summer CFM: 112
6,719
3,206
1,848
5,054
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
.0
0
AED Excursion:
0
0
4,924
4,924
System 1 AC 1 - First Floor Load TOWS: Y
50,280
7,134
43,180
50,314
Check
Supply CFM: 1,965
CFM Per Square ft.:.
0.564
Square ft. of Room Area: 3,483
Square ft. Per Ton:
831
Volume (fl:3) of Cond. Space: 35,411
Total Heating Required Including Ventilation Air:
50,280 Btuh
50.280 MBH
Total Sensible Gain:
43,180 Btuh
86 %
Total Latent Gain:
7,134 Btuh
14 %
Total Cooling Required Including Ventilation Air:
50,314 Btuh
4.19 Tons
(Based On Sensible + Latent)
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as,building use and weather may vary.
mBe);sureto-select a unit that meets both sensible and latent loads-orwoixiingj.torthe •manufacturer's performance data at
your design conditions.
&\NEW'CONSTRUCTION\Chrisi Elite.Files\Stan Pac Riverbend Stamford.rh9 Monday, February 10, 2014, 1:50 PM