Loading...
HomeMy WebLinkAboutOSTDS NEWSCANNED my STATE OF FLORIDA st Lop! P161inti,, DEPARTMENT OF HEALTH aa��1111 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION PERMIT CONSTRUCTION PERMIT FOR: OSTDS New APPLICANT: (Standard Pacific of Florida GP, Inc.) PROPERTY ADDRESS: 13300 NW Baywood PI Palm City, FL 34990 PERMIT #:56-SF-1645916 APPLICATION # : AP 1214944 DATE PAID: FEE PAID: RECEIPT #: DOCUMENT #: PR996943 LOT: 39 BLOCK: SUBDIVISION: Riverbend PROPERTY ID #: 4425-703-0044-000-5 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ 1,350 ] GALLONS / GPD Septic CAPACITY A [ ] GALLONS / GPD N/A CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ D [ 650 ] SQUARE FEET SYSTEM R [ ] SQUARE FEET N/A SYSTEM A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [x] MOUND [ ] I CONFIGURATION: [X] TRENCH [ ] BED [ ] N F LOCATION OF BENCHMARK: site BM top of storm drain grate "elev 7.69" I ELEVATION OF PROPOSED SYSTEM SITE E BOTTOM OF DRAINFIELD TO BE .L D FILL REQUIRED: [ 22.003 INCHES 0 T H E R [ 16.0011 INCHES FT ][ABOVE BELOW] BENCHMARK/REFERENCE POINT [ 20.00 ] [INCHES FT ] [ABOVE BELOW ]BENCHMARK/REFERENCE POINT EXCAVATION REQUIRED: [ 60.001 INCHES The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 520 gpd. The licensed contractor installing the system is responsible for installing the minimum category of tank in accordance with s. 64E-6.013(3)(f), FAC. SPECIFICATIONS BY: Brian Davis TITLE: Master Septic Tank Contractor APPROVED BY: 0 TITLE: Environmental Specialist I St. Lucie CHD Brian J 16gram DATE ISSUED: 12/08/2015 EX N DATCA 01017 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) a aIncorporated: 64E-6.003, FAC 3 v 1.1.4 AP1214944 SE978934 NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN # A02, Tallahassee, Florida 32399-1703. The Agency Clerk's facsimile number is 850-410-1448. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a 'final order'. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. 7 d w��f uw h