HomeMy WebLinkAboutREVISION-ENERGY EFFICIENCY CODEiSCANNtO
FORM R405-2014 By
FLORIDA ENERG`VWOCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Standard Pacific RB Stamford Lot 39
Builder Name: Standard Pacific Homes
Street: 13300 NW Baywood PI
Permit Office: St. Lucie
City, State, Zip: Port St. Lucie , FL,
Permit Number:
Owner: Standard Pacific Homes
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (3971.5 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 3646.00 ft'
b. Frame - Wood, Adjacent
R=11.0 325.43 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 4
d. N/A
R= ft'
10. Ceiling Types (3483.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Cathedral/Single Assembly (Unvented) R=20.0 3483.00 ft'
6. Conditioned floor area above grade (ft') 3483
b. N/A
R= ft'
Conditioned floor area below grade (ft') 0
c. N/A
R= ft'
11. Ducts
R ft'
7. Windows(508.6 sqft.) Description Area
a. Sup: AC 1 First Floor, Ret: AC 1 First Floor, AH: A 6 580
a. U-Factor: Dbl, U=1.07 335.58 ft'
SHGC: SHGC=0.301
b. U-Factor: Dbl, U=1.05 80.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.28
a. Central Unit
56.5 SEER:16.00
c. U-Factor: Dbl, U=1.00 68.99 ft'
SHGC: SHGC=0.32
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 24.00 ft'
a. Electric Heat Pump
57.0 HSPF:9.00
SHGC: other (see details)
Area Weighted Average Overhang Depth: 7.303 ft.
Area Weighted Average SHGC: 0.296
14. Hot water systems
a. Electric
Cap: 50 gallonsEF:
8. Floor Types (3483.0 sqft.) Insulation Area
3.100
a. Slab -On -Grade Edge Insulation R=0.0 3483.00 ft'
b. Conservation features
b. N/A R= ft'
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.146 Total Proposed Modified Loads: 79.36
PASS
Total Baseline Loads: 96.79
I hereby certify that the plans and specifications covered by
Review of the plans and
_S�A?�
this calculation are in compliance with the Florida Energy
specifications covered by this
OgVE
Code. Digitally signed by Chris Wildroudt
r DN: cn=Chris Wildroudt, SUS,
C h
calculation indicates compliance
y ' ='; ��,
ti
1 I S
with the Florida Energy Code.
�.
11JJf .'* �• %l q O
o=Engineered Air, LAC, ou=Sales
PREPARED BY: and Eogio------
Before construction is completed
email=_Chdsw@englneeredairllc.
DATE:
this building will be inspected for
compliance with Section 553.908
}
o a
�; _ Qom-
/d Date: 201610.18'13:10:08 -04'00'
(/
I hereby certify that this building, as oesigned, is in compliance
with the Florida Energy Code.`.
Florida Statutes.
OWNER/AGENT:
BUILDING
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the a i encIW6'6
certified factory -sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accorda % it R4`a A.
test report in accordance with R402.4.1.2.
10/18/2016 1:08 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software
duals ies- s'
v e le age
Page 1 of 5
FORM R405-2014
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Standard Pacific RB Stamford
User
Standard Pacific Homes
1
Standard Pacific Homes
St. Lucie
Single-family
New (From Plans)
Bedrooms: 4
Conditioned Area: 3483
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Lot Information
39
Riverbend
13300 NW Baywood PI
St. Lucie
Port St. Lucie ,
FL,
CLIMATE
Design Location TMY Site
IECC Design Temp
Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90
70
75 722
62 Low
BLOCKS
Number
Name Area
Volume
1
Blockl 3483
37334.9
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
AC 1 First Floor 3483
37334.9 No 5
4
1 Yes
Yes Yes
FLOORS
#
Floor Type Space
Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio AC 1 First Floor 372 ft 0
3483 ft2
__
0 0 1
ROOF
J
V #
Type Materials
Roof Gable Roof
Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip Barrel tile
3773 ft2 0 ft2 Light
0.5
No 0.5
No 20 22.6
ATTIC
/
V #
Type Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
No attic Unvented 0
3483 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac
Truss Type
1
Cathedral/Single Assembly (UnveA'@dl First Floor 20 3483 ft2
0.11
Wood
10/18/2016 1:08 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
3701NITIIM,bre-b.111ElI
WALLS
Adjacent
Cavity
Width Height
Sheathing Framing
Solar
Belo w
nrnt
To
Wall T-V PI, SpaceArea
1 E
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
13
0 10.67 0
138.7 ft2
0.4
0
0.4
0
2 E
Exterior
Concrete Block - Int lns0NC 1 First Flo
4.1
10
0 10.67 0
106.7 ft2
0.4
0
0.4
0
3 E
Exterior
Concrete Block - Int InsiNC 1 First Flo
4.1
13
0 10.67 0
138.7 ft2
0.4
0
.0.4
0
4 E
Exterior
Concrete Block - Int InsiNC 1 First Flo
4.1
12
0 10.67 0
128.0 ft2
0.4
0
0.4
0
5 S
Exterior
Concrete Block - Int Ins9C 1 First Flo
4.1
80
0 10.67 0
853.6 ft2
0.4
0
0.4
0
6 S
Exterior
Concrete Block - Int InsiNC 1 First Flo
4.1
13.5
0 10.67 0
144.0 ft2
0.4
0
0.4
0
7 W
Exterior
Concrete Block - Int InsiNC 1 First Flo
4.1
34
0 10.67 0
362.8 ft2
0.4
0
0.4
0
8 W
Exterior
Concrete Block - Int InsiNC 1 First Flo
4.1
20
0 12.67 0
253.4 ft2
0.4
0
0.4
0
9 N
Exterior
Concrete Block - Int Ins9C 1 First Flo
4.1
14
0 10.67 0
149.4 ft2
0.4
0
0.4
0
10 N
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
24
0 10.67 0
256.1 ft2
0.4
0
0.4
0
11 N
Garage
Frame - Wood AC 1 First Flo
11
8
0 10.67 0
85.4 ft2
0.4
0.4
0
12 W
Garage
Frame - Wood AC 1 First Flo
11
6
0 10.67 0
64.0 ft2
0.4
0.4
0
13 W
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
18
0 10.67 0
192.1 ft2
0.4
0
0.4
0
14 N
Exterior
Concrete Block - Int Ins9C 1 First Flo
4.1
50
0 10.67 0
533.5 ft2
0.4
0
0.4
0
15 S
Exterior
Concrete Block - Int InsiNC 1 First Flo
4.1
6
0 10.67 0
64.0 ft2
0.4
0
0.4
0
16 E
Garage
Frame - Wood AC 1 First Flo
11
16.5
0 10.67 0
176.1 ft2
0.4
0.4
0
17 S
Exterior
Concrete Block - Int InsiNC 1 First Flo
4.1
12
0 10 0
120.0 ft2
0.4
0
0.4
0
18 E
Exterior
Concrete Block - Int InsiNC 1 First Flo
4.1
20.5
0 10 0
205.0 ft2
0.4
0
0.4
0
DOORS
#
Omt
Door Type Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated AC 1 First Flo
None .6
2.7
8
21.4 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Area
Depth
Separation
Int Shade
Screening
1
E 1
Metal Low-E Double Yes
1
0.32
21.3 ft2
23 ft 0 in
2 ft 0 in
None
None
2
E 2
Metal Low-E Double Yes
0.77
0.22
24.0 ft2
13 ft 0 in
2 ft 0 in
None
None
3
E 3
Metal Low-E Double Yes
1.07
0.3
16.2 ft2
6 ft 0 in
2 ft 0 in
None
None
4
S 5
Metal Low-E Double Yes
1.07
0.3
58.5 ft2
2 ft 0 in
2 ft 0 in
None
None
5
S 5
Metal Low-E Double Yes
1.07
0.3
f 22.7 ft2
2 ft 0 in
2 ft 0 in
None
None
6
S 5
Metal Low-E Double Yes
1.07
0.3
9.2 ft2
2 ft 0 in
2 ft 0 in
None
None
7
S 6
Metal Low-E Double Yes
1.05
0.28
80.0 ft2
18 ft 0 in
2 ft 0 in
None
None
8
W 7
Metal Low-E Double Yes
1.07
0.3
58.5 ft2
2 ft 0 in
2 ft 0 in
None
None
9
W 8
Metal Low-E Double Yes
1
0.32
24.9 ft2
12 ft 0 in
1 ft 0 in
None
None
10
N 10
Metal Low-E Double Yes
1.07
0.3
22.7 ft2
9 ft 0 in
2 ft 0 in
None
None
11
W 13
Metal Low-E Double Yes
1.07
0.3
58.5 ft2
6 ft 0 in
2 ft 0 in
None
None
12
N 14
Metal Low-E Double Yes
1.07
0.3
27.3 ft2
2 ft 0 in
2 ft 0 in
None
None
13
N 14
Metal Low-E Double Yes
1.07
0.3
19.5 ft2
2 ft 0 in
2 ft 0 in
None
None
14
N 14
Metal Low-E Double Yes
1.07
0.3
9.2 ft2
2 ft 0 in
2 ft 0 in
None
None
15
N 14
Metal Low-E Double Yes
1
0.32
16.2 ft2
2 ft 0 in
2 ft 0 in
None
None
16
N 14
Metal Low-E Double Yes
1
0.32
6.7 ft2
2 ft 0 in
2 ft 0 in
None
None
10/18/2016 1:08 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V #
Wall
Ornt ID Frame Panes
Overhang
NFRC U-Factor SHGC Area Depth Separation Int Shade
Screening
17
18
S 15 Metal Low-E Double Yes 1.07 0.3 13.7 ft2 2 ft 0 in 2 ft 0 in None
S 17 Metal Low-E Double Yes 1.07 0.3 19.7 ft2 2 ft 0 in 1 ft 0 in None
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
660 ft2
660 ft2 72 ft loft 1
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000341 3111.2 170.8 321.22 .2486 5
HEATING SYSTEM
#
System Type
Subtype Efficiency Capacity Block
Ducts
1
Electric Heat Pump
Split HSPF:9 57 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit
Split SEER: 16 56.5 kBtu/hr 1900 cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location EF Cap Use SetPnt Conservation
1
Electric Heat Pump
Garage 3.1 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
/
V #
-- Supply --
Location R-Value Area
— Return -- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
AC 1 First Flo 6 580 ft2
AC 1 First Flo 160 ft2 Default Leakage AC 1 First F (Default) (Default)
1 1
10/18/2016 1:08 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
Fl1RM RAn.r,-7(11A
TEMPERATURES
.
Programable
Thermostat: Y
Ceiling Fans:
Cooling
H
Jan
Feb
H
Mar
HX
�
Apr
I I
May
I May
Jun
ri Jun
Jul
rl Jul
Aug
ri Aug
ri
Sep
Sep �X�
Oct
Oct
ov
Dec
Venting
Jan
Feb
Mar
Apr
Nov
Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
10/18/2016 1:08 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 82
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows-
Description
a. U-Factor:
Dbl, U=1.07
SHGC:
SHGC=0:30
b. U-Factor:
Dbl, U=1.05
SHGC:
SHGC=0.28
c. U-Factor:
Dbl, U=1.00
SHGC:
SHGC=0.32
d. U-Factor:
other (see details)
SHGC:
other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
13300 NW Baywood PI, Port St. Lucie, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1
3646.00 ft2
b. Frame - Wood, Adjacent
R=11.0
325.43 ft2.
1
c. N/A
R=
ft2
4
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
No
a. Cathedral/Single Assembly (Unvented)
R=20.0
3483.00 ft2
3483
b. N/A
R=
ft2
c. N/A
R=
ft2
Area
11. Ducts
R ft2
3.58 ft2
35
a. Sup: AC 1 First Floor, Ret: AC 1 First Floor, AH: A
6 580
80.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
68.99 ft2
a. Central Unit
56.5 SEER:16.00
24.00 ft2
7.303 ft.
0.296
Insulation Area
R=0.0 3483.00 ft2
R= ft2
R= ft2
13. Heating systems
a. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: �j? it/GJ -&\w� TL. City/FL Zip: �� V71zz \�Q
kBtu/hr Efficiency
57.0 HSPF:9.00
Cap: 50 gallons
EF: 3.1
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtaina, Florida EnergyGauge Rating. Contact the, EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, .contact the Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
10/18/2016 1:08 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
I
Stamford Model
HVAC Load Calculations
for
Standard Pacific Homes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and
Prepared -By:
Chris Wildroudt
Engineered Air LLC CAC
2520 N Andrews Ave
Pompano Beach, F
954 974�2 f
Rhvac - Residential & Light Commercial HVAC.Loads Elite Softwar&'Development, Inc.
Engineered Air, LLC Stamford Model
Margate, FL 33063 ®' Page 2
.Project. Re port
FGeneral Project;lnformation:4=.�•�
Project Title: Stamford Model
Designed By: Chris Wildroudt
Project Date: 2-10-14
Client Name: Standard Pacific Homes
Company Name: Engineered Air LLC CAC045860
Company Representative: Chris Wildroudt
Company Address: 2520 N Andrews Ave Ext
Company City: Pompano Beach, FL 33064
Company Phone: 954 974-7277
Company Fax: 954 973-1883
Reference City: Fort Pierce, Florida
Building Orientation: House faces East
Daily Temperature Range: Medium
Latitude: 27 Degrees
Elevation: 25 ft.
Altitude Factor: 0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 42 39.4 n/a n/a 70 n/a
Summer: 90 75 50% 50% 75 42
Total Building Supply CFM: 1,965 CFM Per Square ft.: 0.564
Square ft. of Room Area: 3,483 Square ft. Per Ton: 831
Volume (ft) of Cond. Space: 35,411 -
Total Heating Required Including Ventilation Air: 50,280 Btuh 50.280 MBH
Total Sensible Gain: 43,180 Btuh 86 %
Total Latent Gain: 7,134 Btuh 14 %
Total Cooling Required Including Ventilation Air: 50,314 Btuh 4.19 Tons (Based On Sensible + Latent)
-Notes:
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Riverbend Stamford.rh9 Monday, February 10, 2014, 1.50 PM
Rhvac - Residential & Light Commercial HVAC Loads
Elite
Software Development, Inc.
Engineered Air, LLC
Stamford
Model
Mar ate', FL 33063 .
Pa e 3
Total Building Summa ,Loads
�� 8 �� ,�AN"�. Area Sens �;
1:P6mponefit r-: Later
Send��sTotalair
�
Description _ ..;�� .
,. ��^ .Quan ,t, .
Loss
Gain
ti ain
wain'
Lo-E French Door: Glazing-Low-E French Door, u-value
96
2,068
0
1,552
1,552
0.77, SHGC 0.22
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
46.2
518
0
578
578
0.4, SHGC 0.31
Lo-E operable: Glazing-Low-E Operable Glass, u-value
155.8
2,622
0
5,308
5,308
0.6, SHGC 0.31
Lo-E French Door: Glazing-Low-E French Door, u-value
40
862
0
924
924
0.77, SHGC 0.22
Lo-E operable: Glazing-Low-E Operable Glass, u-value
316.2
5,319
0
6,275
6,275
0.6, SHGC 0.31
Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value
288
4,760
0
5,532
5,532
0.59, SHGC 0.32
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
22.8
256
0
286
286
0.4, SHGC 0.31
11J: Door -Metal - Fiberglass Core
21.4
192
0
192
192
13A-4ocs: Wall -Block, board insulation only, R-4 board
2476
9,915
0
5,417
5,417
insulation, open core, siding finish
12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud
304.1
311
0
311
311
cavity, no board insulation, brick finish, wood studs
12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud
205
298
0
298
298
cavity, no board insulation, siding finish, wood studs
16D-30: Roof/Ceiling-Under Attic with Insulation on Attic
3482.9
3,121
0
3,344
3,344
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation
22A-pl: Floor -Slab on grade, No edge insulation, no
372
10,302
0
0
0
insulation below floor, any floor cover, passive, light
dry soil
_
__
Subtotals for structure:
40,544
0
30,017
30,017
People:
5
1,500
1,400
2,900
Equipment:
2,000
2,400
4,400
Lighting:
0
0
0
Ductwork:
3,017
428
2,591
3,019
Infiltration: Winter CFM: 218, Summer CFM: 112
6,719
3,206
1,848
5,054
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
AED Excursion:
0
0
4,924
4,924
Total Building Load Totals:
50,280
7,134
43,180
50,314
&i g ures
Check
Total Building Supply CFM: 1,965
CFM Per Square ft.:
0.564
Square ft. of Room Area: 3,483
Square ft.
Per Ton:
831
Volume (ft3) of Cond. Space: 35,411
Build n91 Loy N-(
Total Heating Required Including Ventilation Air:
50,280 Btuh
50.280 MBH
Total Sensible Gain:
43,180 Btuh
86 %
Total Latent Gain:
7,134 Btuh
14 . %
Total Cooling Required Including Ventilation Air:
50,314 Btuh
4.19 Tons
(Based
On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer
program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data
at
your design conditions.
S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Riverbend Stamford.rh9 Monday, February 10, 2014, 1:50 PM
Rhvac - Residential & Light Commercial HVAC Loads
Elite
Software Development, Inc.
Engineered Air, LLC
®
Stamford Model
Margate, FL 33063 .
Page 4
S stem.1 AC 1 - First,Floor Summary:L;oads"
Component 4 o,;,
Area rSen Sen >a l otal
��„ Gaim
Descri tion. ,, .z. _ . ,.� " s .. �;.
Quan.
" � 'Loss
Gain
Gain
t �
Lo-E French Door: Glazing-Low-E French Door, u-value
96
2,068
0
1,552
11552
0.77, SHGC 0.22
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
46.2
518
0
578
578
0.4, SHGC 0.31
Lo-E operable: Glazing-Low-E Operable Glass, u-value
155.8
2,622
0
5,308
5,308
0.6, SHGC 0.31
Lo-E French Door: Glazing-Low-E French Door, u-value
40
862
0
924
924
0.77, SHGC 0.22
Lo-E operable: Glazing-Low-E Operable Glass, u-value
316.2
5,319
0
6,275
6,275
0.6, SHGC 0.31
Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value
288
4,760
0
_ 5,532
5,532
0.59, SHGC 0.32
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
22.8
256
0
286
286
0.4, SHGC 0.31
11J: Door -Metal - Fiberglass Core
21.4
192
0
192
192
13A-4ocs: Wall -Block, board insulation only, R-4 board
2476
9,915
0
5,417
5,417
insulation, open core, siding finish
12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud
304.1
311
0
311
311
cavity, no board insulation, brick finish, wood studs
12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud
205
298
0
298
298
cavity, no board insulation, siding finish, wood studs
16D-30: Roof/Ceiling-Under Attic with Insulation on Attic 3482.9
3,121
0
3,344
3,344
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation
22A-pi: Floor -Slab on grade, No edge insulation, no
372
10,302
0
0
0
insulation below floor, any floor cover, passive, light
dry soil
Subtotals for structure:
40,544
0
30,017
30,017
People:
5
1,500
' 1,400
2,900
Equipment:
2,000
( 2,400
4,400
Lighting:
0
0
0
Ductwork:
3,017
428
2,591
3,019
Infiltration: Winter CFM: 218, Summer CFM: 112
6,719
3,206
1,848
5,054
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
AED Excursion:
0
0
4,924
4,924
_ _ _
System 1 AC 1 - First Floor Load Totals:
50,280
7,134
43,180
50,314
Check Fi urges
Supply CFM: 1,965
CFM Per
Square ft.:
0.564
Square ft. of Room Area: 3,483
Square
ft. Per Ton:
831
Volume (ft3) of Cond. Space: 35,411
' S stern Loads
Total Heating Required Including Ventilation Air: 50,280
Btuh
50.280
MB.H
Total Sensible Gain: 43,180
Btuh
86
%
Total Latent Gain: 7,134
Btuh
14
%
Total Cooling Required Including Ventilation Air:, 50,314
Btuh
4.19
Tons (Based On Sensible
+ Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual
D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads
according to the manufacturer's performance data at
your design conditions.
S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Riverbend Stamford.rh9 Monday, February 10, 2014, 1:50 PM