HomeMy WebLinkAboutREVISION-ENERGY EFFICIENCY CODEiSCANNtO FORM R405-2014 By FLORIDA ENERG`VWOCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Standard Pacific RB Stamford Lot 39 Builder Name: Standard Pacific Homes Street: 13300 NW Baywood PI Permit Office: St. Lucie City, State, Zip: Port St. Lucie , FL, Permit Number: Owner: Standard Pacific Homes Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (3971.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 3646.00 ft' b. Frame - Wood, Adjacent R=11.0 325.43 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 4 d. N/A R= ft' 10. Ceiling Types (3483.0 sqft.) Insulation Area 5. Is this a worst case? No a. Cathedral/Single Assembly (Unvented) R=20.0 3483.00 ft' 6. Conditioned floor area above grade (ft') 3483 b. N/A R= ft' Conditioned floor area below grade (ft') 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(508.6 sqft.) Description Area a. Sup: AC 1 First Floor, Ret: AC 1 First Floor, AH: A 6 580 a. U-Factor: Dbl, U=1.07 335.58 ft' SHGC: SHGC=0.301 b. U-Factor: Dbl, U=1.05 80.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a. Central Unit 56.5 SEER:16.00 c. U-Factor: Dbl, U=1.00 68.99 ft' SHGC: SHGC=0.32 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 24.00 ft' a. Electric Heat Pump 57.0 HSPF:9.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 7.303 ft. Area Weighted Average SHGC: 0.296 14. Hot water systems a. Electric Cap: 50 gallonsEF: 8. Floor Types (3483.0 sqft.) Insulation Area 3.100 a. Slab -On -Grade Edge Insulation R=0.0 3483.00 ft' b. Conservation features b. N/A R= ft' None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.146 Total Proposed Modified Loads: 79.36 PASS Total Baseline Loads: 96.79 I hereby certify that the plans and specifications covered by Review of the plans and _S�A?� this calculation are in compliance with the Florida Energy specifications covered by this OgVE Code. Digitally signed by Chris Wildroudt r DN: cn=Chris Wildroudt, SUS, C h calculation indicates compliance y ' ='; ��, ti 1 I S with the Florida Energy Code. �. 11JJf .'* �• %l q O o=Engineered Air, LAC, ou=Sales PREPARED BY: and Eogio------ Before construction is completed email=_Chdsw@englneeredairllc. DATE: this building will be inspected for compliance with Section 553.908 } o a �; _ Qom- /d Date: 201610.18'13:10:08 -04'00' (/ I hereby certify that this building, as oesigned, is in compliance with the Florida Energy Code.`. Florida Statutes. OWNER/AGENT: BUILDING DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the a i encIW6'6 certified factory -sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accorda % it R4`a A. test report in accordance with R402.4.1.2. 10/18/2016 1:08 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software duals ies- s' v e le age Page 1 of 5 FORM R405-2014 PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Standard Pacific RB Stamford User Standard Pacific Homes 1 Standard Pacific Homes St. Lucie Single-family New (From Plans) Bedrooms: 4 Conditioned Area: 3483 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Lot Information 39 Riverbend 13300 NW Baywood PI St. Lucie Port St. Lucie , FL, CLIMATE Design Location TMY Site IECC Design Temp Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 3483 37334.9 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 AC 1 First Floor 3483 37334.9 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio AC 1 First Floor 372 ft 0 3483 ft2 __ 0 0 1 ROOF J V # Type Materials Roof Gable Roof Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Barrel tile 3773 ft2 0 ft2 Light 0.5 No 0.5 No 20 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 No attic Unvented 0 3483 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Cathedral/Single Assembly (UnveA'@dl First Floor 20 3483 ft2 0.11 Wood 10/18/2016 1:08 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 3701NITIIM,bre-b.111ElI WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo w nrnt To Wall T-V PI, SpaceArea 1 E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 13 0 10.67 0 138.7 ft2 0.4 0 0.4 0 2 E Exterior Concrete Block - Int lns0NC 1 First Flo 4.1 10 0 10.67 0 106.7 ft2 0.4 0 0.4 0 3 E Exterior Concrete Block - Int InsiNC 1 First Flo 4.1 13 0 10.67 0 138.7 ft2 0.4 0 .0.4 0 4 E Exterior Concrete Block - Int InsiNC 1 First Flo 4.1 12 0 10.67 0 128.0 ft2 0.4 0 0.4 0 5 S Exterior Concrete Block - Int Ins9C 1 First Flo 4.1 80 0 10.67 0 853.6 ft2 0.4 0 0.4 0 6 S Exterior Concrete Block - Int InsiNC 1 First Flo 4.1 13.5 0 10.67 0 144.0 ft2 0.4 0 0.4 0 7 W Exterior Concrete Block - Int InsiNC 1 First Flo 4.1 34 0 10.67 0 362.8 ft2 0.4 0 0.4 0 8 W Exterior Concrete Block - Int InsiNC 1 First Flo 4.1 20 0 12.67 0 253.4 ft2 0.4 0 0.4 0 9 N Exterior Concrete Block - Int Ins9C 1 First Flo 4.1 14 0 10.67 0 149.4 ft2 0.4 0 0.4 0 10 N Exterior Concrete Block - Int InsAC 1 First Flo 4.1 24 0 10.67 0 256.1 ft2 0.4 0 0.4 0 11 N Garage Frame - Wood AC 1 First Flo 11 8 0 10.67 0 85.4 ft2 0.4 0.4 0 12 W Garage Frame - Wood AC 1 First Flo 11 6 0 10.67 0 64.0 ft2 0.4 0.4 0 13 W Exterior Concrete Block - Int InsAC 1 First Flo 4.1 18 0 10.67 0 192.1 ft2 0.4 0 0.4 0 14 N Exterior Concrete Block - Int Ins9C 1 First Flo 4.1 50 0 10.67 0 533.5 ft2 0.4 0 0.4 0 15 S Exterior Concrete Block - Int InsiNC 1 First Flo 4.1 6 0 10.67 0 64.0 ft2 0.4 0 0.4 0 16 E Garage Frame - Wood AC 1 First Flo 11 16.5 0 10.67 0 176.1 ft2 0.4 0.4 0 17 S Exterior Concrete Block - Int InsiNC 1 First Flo 4.1 12 0 10 0 120.0 ft2 0.4 0 0.4 0 18 E Exterior Concrete Block - Int InsiNC 1 First Flo 4.1 20.5 0 10 0 205.0 ft2 0.4 0 0.4 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated AC 1 First Flo None .6 2.7 8 21.4 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Double Yes 1 0.32 21.3 ft2 23 ft 0 in 2 ft 0 in None None 2 E 2 Metal Low-E Double Yes 0.77 0.22 24.0 ft2 13 ft 0 in 2 ft 0 in None None 3 E 3 Metal Low-E Double Yes 1.07 0.3 16.2 ft2 6 ft 0 in 2 ft 0 in None None 4 S 5 Metal Low-E Double Yes 1.07 0.3 58.5 ft2 2 ft 0 in 2 ft 0 in None None 5 S 5 Metal Low-E Double Yes 1.07 0.3 f 22.7 ft2 2 ft 0 in 2 ft 0 in None None 6 S 5 Metal Low-E Double Yes 1.07 0.3 9.2 ft2 2 ft 0 in 2 ft 0 in None None 7 S 6 Metal Low-E Double Yes 1.05 0.28 80.0 ft2 18 ft 0 in 2 ft 0 in None None 8 W 7 Metal Low-E Double Yes 1.07 0.3 58.5 ft2 2 ft 0 in 2 ft 0 in None None 9 W 8 Metal Low-E Double Yes 1 0.32 24.9 ft2 12 ft 0 in 1 ft 0 in None None 10 N 10 Metal Low-E Double Yes 1.07 0.3 22.7 ft2 9 ft 0 in 2 ft 0 in None None 11 W 13 Metal Low-E Double Yes 1.07 0.3 58.5 ft2 6 ft 0 in 2 ft 0 in None None 12 N 14 Metal Low-E Double Yes 1.07 0.3 27.3 ft2 2 ft 0 in 2 ft 0 in None None 13 N 14 Metal Low-E Double Yes 1.07 0.3 19.5 ft2 2 ft 0 in 2 ft 0 in None None 14 N 14 Metal Low-E Double Yes 1.07 0.3 9.2 ft2 2 ft 0 in 2 ft 0 in None None 15 N 14 Metal Low-E Double Yes 1 0.32 16.2 ft2 2 ft 0 in 2 ft 0 in None None 16 N 14 Metal Low-E Double Yes 1 0.32 6.7 ft2 2 ft 0 in 2 ft 0 in None None 10/18/2016 1:08 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Ornt ID Frame Panes Overhang NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 17 18 S 15 Metal Low-E Double Yes 1.07 0.3 13.7 ft2 2 ft 0 in 2 ft 0 in None S 17 Metal Low-E Double Yes 1.07 0.3 19.7 ft2 2 ft 0 in 1 ft 0 in None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 660 ft2 660 ft2 72 ft loft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000341 3111.2 170.8 321.22 .2486 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:9 57 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 56.5 kBtu/hr 1900 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Heat Pump Garage 3.1 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / V # -- Supply -- Location R-Value Area — Return -- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 AC 1 First Flo 6 580 ft2 AC 1 First Flo 160 ft2 Default Leakage AC 1 First F (Default) (Default) 1 1 10/18/2016 1:08 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 Fl1RM RAn.r,-7(11A TEMPERATURES . Programable Thermostat: Y Ceiling Fans: Cooling H Jan Feb H Mar HX � Apr I I May I May Jun ri Jun Jul rl Jul Aug ri Aug ri Sep Sep �X� Oct Oct ov Dec Venting Jan Feb Mar Apr Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 10/18/2016 1:08 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 82 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Dbl, U=1.07 SHGC: SHGC=0:30 b. U-Factor: Dbl, U=1.05 SHGC: SHGC=0.28 c. U-Factor: Dbl, U=1.00 SHGC: SHGC=0.32 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 13300 NW Baywood PI, Port St. Lucie, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Int Insul, Exterior R=4.1 3646.00 ft2 b. Frame - Wood, Adjacent R=11.0 325.43 ft2. 1 c. N/A R= ft2 4 d. N/A R= ft2 10. Ceiling Types Insulation Area No a. Cathedral/Single Assembly (Unvented) R=20.0 3483.00 ft2 3483 b. N/A R= ft2 c. N/A R= ft2 Area 11. Ducts R ft2 3.58 ft2 35 a. Sup: AC 1 First Floor, Ret: AC 1 First Floor, AH: A 6 580 80.00 ft2 12. Cooling systems kBtu/hr Efficiency 68.99 ft2 a. Central Unit 56.5 SEER:16.00 24.00 ft2 7.303 ft. 0.296 Insulation Area R=0.0 3483.00 ft2 R= ft2 R= ft2 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: �j? it/GJ -&\w� TL. City/FL Zip: �� V71zz \�Q kBtu/hr Efficiency 57.0 HSPF:9.00 Cap: 50 gallons EF: 3.1 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtaina, Florida EnergyGauge Rating. Contact the, EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, .contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/18/2016 1:08 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 I Stamford Model HVAC Load Calculations for Standard Pacific Homes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and Prepared -By: Chris Wildroudt Engineered Air LLC CAC 2520 N Andrews Ave Pompano Beach, F 954 974�2 f Rhvac - Residential & Light Commercial HVAC.Loads Elite Softwar&'Development, Inc. Engineered Air, LLC Stamford Model Margate, FL 33063 ®' Page 2 .Project. Re port FGeneral Project;lnformation:4=.�•� Project Title: Stamford Model Designed By: Chris Wildroudt Project Date: 2-10-14 Client Name: Standard Pacific Homes Company Name: Engineered Air LLC CAC045860 Company Representative: Chris Wildroudt Company Address: 2520 N Andrews Ave Ext Company City: Pompano Beach, FL 33064 Company Phone: 954 974-7277 Company Fax: 954 973-1883 Reference City: Fort Pierce, Florida Building Orientation: House faces East Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 75 50% 50% 75 42 Total Building Supply CFM: 1,965 CFM Per Square ft.: 0.564 Square ft. of Room Area: 3,483 Square ft. Per Ton: 831 Volume (ft) of Cond. Space: 35,411 - Total Heating Required Including Ventilation Air: 50,280 Btuh 50.280 MBH Total Sensible Gain: 43,180 Btuh 86 % Total Latent Gain: 7,134 Btuh 14 % Total Cooling Required Including Ventilation Air: 50,314 Btuh 4.19 Tons (Based On Sensible + Latent) -Notes: Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Riverbend Stamford.rh9 Monday, February 10, 2014, 1.50 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Engineered Air, LLC Stamford Model Mar ate', FL 33063 . Pa e 3 Total Building Summa ,Loads �� 8 �� ,�AN"�. Area Sens �; 1:P6mponefit r-: Later Send��sTotalair � Description _ ..;�� . ,. ��^ .Quan ,t, . Loss Gain ti ain wain' Lo-E French Door: Glazing-Low-E French Door, u-value 96 2,068 0 1,552 1,552 0.77, SHGC 0.22 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 46.2 518 0 578 578 0.4, SHGC 0.31 Lo-E operable: Glazing-Low-E Operable Glass, u-value 155.8 2,622 0 5,308 5,308 0.6, SHGC 0.31 Lo-E French Door: Glazing-Low-E French Door, u-value 40 862 0 924 924 0.77, SHGC 0.22 Lo-E operable: Glazing-Low-E Operable Glass, u-value 316.2 5,319 0 6,275 6,275 0.6, SHGC 0.31 Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value 288 4,760 0 5,532 5,532 0.59, SHGC 0.32 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 22.8 256 0 286 286 0.4, SHGC 0.31 11J: Door -Metal - Fiberglass Core 21.4 192 0 192 192 13A-4ocs: Wall -Block, board insulation only, R-4 board 2476 9,915 0 5,417 5,417 insulation, open core, siding finish 12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud 304.1 311 0 311 311 cavity, no board insulation, brick finish, wood studs 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud 205 298 0 298 298 cavity, no board insulation, siding finish, wood studs 16D-30: Roof/Ceiling-Under Attic with Insulation on Attic 3482.9 3,121 0 3,344 3,344 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-30 insulation 22A-pl: Floor -Slab on grade, No edge insulation, no 372 10,302 0 0 0 insulation below floor, any floor cover, passive, light dry soil _ __ Subtotals for structure: 40,544 0 30,017 30,017 People: 5 1,500 1,400 2,900 Equipment: 2,000 2,400 4,400 Lighting: 0 0 0 Ductwork: 3,017 428 2,591 3,019 Infiltration: Winter CFM: 218, Summer CFM: 112 6,719 3,206 1,848 5,054 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 4,924 4,924 Total Building Load Totals: 50,280 7,134 43,180 50,314 &i g ures Check Total Building Supply CFM: 1,965 CFM Per Square ft.: 0.564 Square ft. of Room Area: 3,483 Square ft. Per Ton: 831 Volume (ft3) of Cond. Space: 35,411 Build n91 Loy N-( Total Heating Required Including Ventilation Air: 50,280 Btuh 50.280 MBH Total Sensible Gain: 43,180 Btuh 86 % Total Latent Gain: 7,134 Btuh 14 . % Total Cooling Required Including Ventilation Air: 50,314 Btuh 4.19 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Riverbend Stamford.rh9 Monday, February 10, 2014, 1:50 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Engineered Air, LLC ® Stamford Model Margate, FL 33063 . Page 4 S stem.1 AC 1 - First,Floor Summary:L;oads" Component 4 o,;, Area rSen Sen >a l otal ��„ Gaim Descri tion. ,, .z. _ . ,.� " s .. �;. Quan. " � 'Loss Gain Gain t � Lo-E French Door: Glazing-Low-E French Door, u-value 96 2,068 0 1,552 11552 0.77, SHGC 0.22 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 46.2 518 0 578 578 0.4, SHGC 0.31 Lo-E operable: Glazing-Low-E Operable Glass, u-value 155.8 2,622 0 5,308 5,308 0.6, SHGC 0.31 Lo-E French Door: Glazing-Low-E French Door, u-value 40 862 0 924 924 0.77, SHGC 0.22 Lo-E operable: Glazing-Low-E Operable Glass, u-value 316.2 5,319 0 6,275 6,275 0.6, SHGC 0.31 Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value 288 4,760 0 _ 5,532 5,532 0.59, SHGC 0.32 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 22.8 256 0 286 286 0.4, SHGC 0.31 11J: Door -Metal - Fiberglass Core 21.4 192 0 192 192 13A-4ocs: Wall -Block, board insulation only, R-4 board 2476 9,915 0 5,417 5,417 insulation, open core, siding finish 12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud 304.1 311 0 311 311 cavity, no board insulation, brick finish, wood studs 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud 205 298 0 298 298 cavity, no board insulation, siding finish, wood studs 16D-30: Roof/Ceiling-Under Attic with Insulation on Attic 3482.9 3,121 0 3,344 3,344 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-30 insulation 22A-pi: Floor -Slab on grade, No edge insulation, no 372 10,302 0 0 0 insulation below floor, any floor cover, passive, light dry soil Subtotals for structure: 40,544 0 30,017 30,017 People: 5 1,500 ' 1,400 2,900 Equipment: 2,000 ( 2,400 4,400 Lighting: 0 0 0 Ductwork: 3,017 428 2,591 3,019 Infiltration: Winter CFM: 218, Summer CFM: 112 6,719 3,206 1,848 5,054 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 4,924 4,924 _ _ _ System 1 AC 1 - First Floor Load Totals: 50,280 7,134 43,180 50,314 Check Fi urges Supply CFM: 1,965 CFM Per Square ft.: 0.564 Square ft. of Room Area: 3,483 Square ft. Per Ton: 831 Volume (ft3) of Cond. Space: 35,411 ' S stern Loads Total Heating Required Including Ventilation Air: 50,280 Btuh 50.280 MB.H Total Sensible Gain: 43,180 Btuh 86 % Total Latent Gain: 7,134 Btuh 14 % Total Cooling Required Including Ventilation Air:, 50,314 Btuh 4.19 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Riverbend Stamford.rh9 Monday, February 10, 2014, 1:50 PM