Soil Nuclear Gauge Client: Project:
Report Date: 3/28/2016 Standard Pacific Homes, South Florida 13-0183.00
Test Method: ASTM D 6938 825 Coral Ridge Drive Riverbend
Coral Springs, FL 33071-4180 St. Lucie County, Florida
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
N
Maximum
Dry Density
(pcf)
In Place
Moisture
(%)
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
N
Remark
43
3/24/16
P-2
NIA
13.0
106.0
8.9
100.2
12
95
95 / 105
Pass
44
3/24/16
P-2
N/A
13.0
106.0
9.0
101.9
12
96
95 / 105
Pass
45
3/24/16
P-2
N/A
13.0
106.0
8.3
100.9
12
95
95 / 105
Pass
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN
Field Technician
43
Below Slab Grade: Lot No. 39, Foundation Pad, Northwest Corner
0-1
Troxler T3430 36442
Rivera, Angel
44
Below Slab Grade: Lot No. 39, Foundation Pad, Center Area
0-1
Troxler T3430 36442
Rivera, Angel
45
Below Slab Grade: Lot No. 39, Foundation Pad, Southeast Comer
0-1
Troxler T3430 36442
Rivera, Angel
Remarks
Comments
Related Tests
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter".
Gauge calibration data on file with the testing agency.
43, 44, 45: 1 - 2 HCP=50+, > 95 % Compaction, PASS. HCP tests are
empirically correlated to the relative density of the soil.
Test #
Related Test #
T Test Type
tAAY 12 2016
-Public WOri4s
.. ? Ltcie Coldrlt;,
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
o`o�A9AA16A1BPe0,�
6�6'7 S3/28/2Q�T6 i
o [ obald W. Molgr, P.E. o Cr-
LU
.Professional Enet 60 m
6Sta &of FI6f� Q •• � w
mmp 0 = F L O F� 0G�C0%
®®9�d gs S A 014 4 �✓ �®
'P,,,F -X'- 1Ia I !-03sC�
Page 1 of 1