HomeMy WebLinkAboutSEWAGE- CONSTRUCTION INSPECTION & FINAL APPROVALAPPLICATION #:AP1214944 STATE OF FLORIDA ICo Q l U - PERMIT #:56-SF-1645915 DEPARTMENT OF HEALTH I DOCUMENT #:Ff1088096 ' ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:12/03/2015 Sw✓ NN� FEE PAID:400.00 RECEIPT #:56-PID-2855407 APPLICANT: Standard Pacific of Florida GP,, Inc. QO Q 0Afy6-fnpj<< AGENT: The Milbor Group, Inc. PROPERTY ADDRESS: '3061 NW Radcliffe Way Palm City, FL 34590 LOT: 39 BLOCK: SUBDIVISION: Riverbend ID#: 4426-703-0044-000-5 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [11 900.00 [21 750.00 [ 1 [271 SURFACE WATER FT [ ] [021 TANK MATERIAL Concrete [ 1 [281 DITCHES FT [ ] [031 OUTLET DEVICE. [ ] [291 PRIVATE WELLS FT [ 1 [041 MULTt-CHAMBERED [ L_Yj N ] [ ] [30.1 PUBLIC WELLS FT [ ] [051 OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT [ ] [06] LEGEND 1., 28-015-04SC3 2. 28-015-01SC3 [ ] [321 POTABLE WATER 65 FT ( ] (071 WATERTIGHT [ ] [331 BUILDING FOUNDATIONS. 5 FT [ ] [081 LEVEL [ 1 [341 PROPERTY LINES 5 FT [ ] [691 DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ 1 [101 AREA [11 656.56 [2] SQFT [ 1 [361 DRAINFIELD COVER ( ] [111 DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS. [121 NUMBER OF DRAINLINES 1. 4.00 2. [ 1 [381 SLOPES ✓ [131 ] DRAINLINE SEPARATION [ ] [391 STABILIZATION 12/19/2016 [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 24.00 [ ] [401 UNOBSTRUCTED AREA [ ] [.17] SYSTEM LOCATION [ ] [411 STORMWATER'RUNOFF [ ] [181 DOSING PUMPS 1.00 [ ] [421 ALARMS [ ] [191 AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT` [ ] [201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL I ] [46] FINAL SITE GRADING [] [221 FILL AMOUNT [ ] [.471 CONTRACTOR Brian Davis (Brian Davis Sep [ ]. [231 FILL TEXTURE [ ] [481 OTHER INFILTRATOR Quick4 Plus. EQ36 LP [ ] (241 EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED & FILLED Comments: Comments are on.page 2. CONSTRUCTION [ APBROyED / DISAPPROVED ] : St. Lucie CHI) DATE: 1.0/26/201¢ Environmental Sp i�a st II Brian J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM ] [. APPROVED :/ DISAPPROVED St. Lucie CHD DATE: 2/19/ 16 Environment pec st (Explanation ofViolat'iona on following page) ran Ingram E LTH) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC P d 2 of 3 EH Database v 1.0.1 AP1214944 E101646916 RECEIVED DEC 21 2016