FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 005 Ft 833 B RHG Den - E
Builder Name:
Street: 5376 OAKLAND LAKE CIR ���6�961h
Permit Office: St. Lucie
City, State, Zip: FT. PIERCE, FL, BY
Permit Number:
Owner: Ran Homes Jurisdiction: 661000
s �} Lucippm, /
1I
Design Location: FL, Fort Pierce `
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1707.3 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1365.00 ft2
b. Frame - Wood, Adjacent
R=11.0 342.33 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (1833.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1833.00 ft2
6. Conditioned floor area above grade (ft2) 1833
b. N/A •
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
11. Ducts
R= ft2
R ft2
7. Windows(168.4 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 366.6
a. U-Factor: Dbl, U=0.54 115.11 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl, U=0.63 53.33 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.32
a. Central Unit
28.0 SEER:14.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
27.8 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.313
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1833.0. sqft.) Insulation Area
EF: 0.900
a. Slab -On -Grade Edge Insulation R=0.0 1833.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
'15. Credits
Pstat
Glass/Floor Area: 0.092 Total Proposed Modified Loads: 57.51
PASS
Total Baseline Loads: 58.29
I hereby certify that the plans and specifications covered by
Review of the plans and
4SiiE STA?'
this calculation are in compliance with the Florida Energy
specifications covered by this
1�� a FOB,
Code.
calculation indicates compliance
with the Florida Energy Code.
If y?Y�a; .,=r '•,.��;� �O
PREPARED BY:
DATE. 08-10-2018
Before construction is completed
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy
COIj 1NE � .
Code.
OWNER/AGENT: i � _
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified fa sea cf�ino 9ce)wittF`_;�i4g
-
- Co
mplianc ;r�q 1sz_p�Airr e>rhtj' jti� tlo I': spection Checklist in accordance with R402.4.1.1 and this project requires an
envelope lea g� t' t rep�Orty h: eriel:4p lei o greater than 7.00 ACH50 (R402.4.1.2).
- Complianc w fi ��o� e x lea a', � � res a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accpd eikptlj/f;1jF)ESNE j /C$dlxp of greater than 0.040 Qn for whole house.
8/10/2018 9:5WAW 11' `"`" ' " ergyGaUdt;® L18A =FIaRes2017 Section R405.4.1 Compliant Software Page 1 of 4
File COPY
rnQnn RnnV_9n17
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 005 F1833 B RHG Den - Bedrooms: 3
User Conditioned Area: 1833
Ryan Homes Total Stories: 1
1 Worst Case: No
Rotate Angle: 0
St. Lucie Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Lot Information
05
Oakland Lake
5376 OAKLAND LAKE
St. Lucie
FT. PIERCE,
FL,
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1833 15947.1
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
1833 15947.1 Yes 4
3
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 157.5 ft 0
1833 ft2
____
0.29 0 0.71
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or Shed Composition shingles 1985 ft2 382 ft2 Dark
0.5
N 0.5
No 0 22.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 1833 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1833 ft2 0.1
Wood
8/10/2018 9:54 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4
FnRAA PAnr,_7n17
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar Below
1
2
3
4
5
S
E
N
W
-
Exterior Concrete Block - Int Insul Main
Exterior Concrete Block - Int Insul Main
Exterior Concrete Block - Int Insul Main
Exterior Concrete Block - Int Insul Main
Garage Frame - Wood Main
4.1 48 0 8
4.1 30 6 8
4.1 28 6 8
4.1 50 6 8
11 39 6 8
8 416.0 ft2
8 .264.3 ft2
8 247.0 ft2
8 437.7 ft2
8 342.3 ft2
0 0 0.5
0 0 0.5
0 0 0.5
0 0 0.5
0 0.25 0.5
0
0
0
0
0
DOORS
#
Ornt Door Type Space
Storms
U-Value Ft
In FtWidthArea
In
1
2
E Insulated Main
Wood Main
None
None
.4 3
.46 2
6 8
8 6 8
20 ft2
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
#
Wall
Ornt ID Frame Panes NFRC
U-Factor SHGC . Imp
Overhang _
Area Depth Separation Int Shade
Screening
1
2.
3
4
E 2 Metal Low-E Double Yes
N 3 Metal Low-E Double Yes
W 4 Metal Low-E Double Yes
W 4 Metal Low-E Double Yes
0.54 0.31 N
0.54 0.31 N
6.54 0.31 N
0.63 0.32 N
49.3 ft2 1 ft 0 in
16.4 ft2 1 ft 0 in
49.3 ft2 1 ft 0 in
53.3 ft2 1 ft 0 in
2 ft 0 in Drapes/blinds
2 ft 0 in Drapes/blinds
2 ft 0 in Drapes/blinds
2 ft 0 in None
None
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
411 ft2 411 ft2
64 ft
8.7 ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000387
1860.5 102.14 192.09 .2825
7
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
HSPF:8.2
27.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts.
1
Central Unit Split
SEER: 14
28 kBtu/hr 840 of 0.75 1
sys#1
8/10/2018 9:54 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4
FnRnn RenF-gn17
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.9 50 gal
60 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector
Model
# Area
Volume
FEF
None
None
ft2
DUCTS
/
---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
�/ #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN RLF
Heat Cool
1
Attic
6 366.6 ft
Main
91.65 ft Proposed Qn
Main
--- cfm
73.3 cfm 0.04
0.50
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
HeatinJan
j Feb
Feb
Mar
Mar
Apr
Apr
May X� Jun Jul
May ] Jun E Jul
1 AugSep
] Aue
Oct
Oct
Nov
Nov
Dec
Dec
Ventin (J Jan
t
lXJ
I ]Feb
Mar
Apr [
l
May l ]Jun [ Jul
l
] Aug
e
IXXX]]]
l
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
8/10/2018 9:54 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 5376 OAKLAND LAKE CIR Permit Number:
FT. PIERCE, FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing
methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Instal lation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building. thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended
weatherstripping or other infiltration control measures.
2. Dampers including exhaust, intake; makeup air, backdraft and flue dampers shall be closed, but not sealed beyond
intended infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
R402.4.3 Fenestration air leakage Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or
AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
8/10/2018 9:55 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 1 of 5
MANDATORY REQUIREMENTS . (Continued)
R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls.
R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the
manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C)
or below 55OF (13°C) shall be insulated to a minimum of R-3.
R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return
pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
8/10/2018 9:55 AM EnergyGaugeOO USA - FlaRes2017 - FBC 6th Edition (2017) Complian Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 31/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100°F to 140°F (38°C to 60°C).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of
combustion types of service water -heating systems to be turned off.
R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that
affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFLOW RATE MAXIMU
(CFM)
Range hoods
Any
2.8 cfm/watt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
Bathroom, utility room
90
2.8 cfm/watt
Any
For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916
8/10/2018 9:55 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.7.1.1 Cooling equipment'capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50OF (10 °C), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40IF (4.81C).
R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on.according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool'and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
8/10/2018 9:55 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 4 of 5
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas (Mandatory)he energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps.
Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
8/10/2018 9:55 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 5 of 5
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
5376 OAKLAND LAKE CIR, FT. PIERCE, FL,
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family .
4. Number of Bedrooms
5. Is this a worst case?
B. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Dbl, U=0.54
SHGC: SHGC=0.31
b. U-Factor: Dbl, U=0.63
SHGC: SHGC=0.32
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
New (From Plans)
9. Wall Types
Single-family
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Adjacent
1
c. N/A
3
d. N/A
10. Ceiling Types
No
a. Under Attic (Vented)
1833
b. N/A
c. N/A
Area
11. Ducts
115.11 ft2
a. Sup: Attic, Ret: Main, AH: Main
53.33 ft2
12. Cooling systems
ft2
a. Central Unit
ft2
1.000 ft.
0.313
8. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1833.00 ft2
b. N/A R= ft2
c. N/A R= ft2
13. Heating systems
a. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: n gUJ_,Q DatE
Address of New Home: �SSD kD LdNQ C`\ f
RA(3•00
City/FL Zip:';rA'?',0<-L,Q
3kA 01
Insulation Area
R=4.1 1365.00 ft2
R=11.0 342.33 ft2
R=
ft2
R=
ft2
Insulation
Area
R=30.0
1833.00 ft2
R=
ft2
R=
ft2
R ft2
6 366.6
kBtu/hr
Efficiency
28.0
SEER:14.00
kBtu/hr Efficiency
27.8 HSPF:8.20
Cap: 50 gallons
EF: 0.9
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8/10/2018 9:55 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Lot 005 F1833 B RHG Den - E Builder Name:
Street: 5376 OAKLAND LAKE CIR Permit Office: St. Lucie
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Ryan Homes Jurisdiction: 661000
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
,�.Ytnnrj behind piping and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover nlatps and walls or ceelmnas.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
8/10/2018 9:55 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Summary Job: Lot005 F1833 B RHG Den
Project S
...
-�- wrightsoft® r Date: 05/14/2018
Entire House BY XF/RI/MC
One Stop Cooling and Heating
7225 Sandscove Cout. W irter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: ww vaOneStopCooling.com License: CAC032444
Project Information
For: Ryan Homes
5376 OAKLAND LAKE CIR, FT. PIERCE, FL
Notes:
Design Information
Weather: Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42
cF
Outside db
90
OF
Inside db 68
OF
Inside db
72
°F
Design TD 26
OF
Design TD
18
OF
Daily range
M
Relative humidity
50
%
Moisture difference
68
gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 17290
Btuh
Structure
17400
Btuh
Ducts 1765
Btuh
Ducts
3492
Btuh
Central vent (0 cfm) 0
Btuh
Central vent (0 cfm)
0
Btuh
(none)
(none)
Humidification 0
Btuh
Blower
0
Btuh
Piping 0
Btuh
Equipment load 19055
Btuh
Use manufacturer's data
n
Rate/swing multiplier
Equipment load
0.95
19848
Btuh
Infiltration
sensible
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
3259
Btuh
Ducts
890
Btuh
Central vent (0 cfm)
Btuh
Heating
Cooling
(none)
Area (ft2) 1838
1838
Equipment latent load
4158
Btuh
Volume (ft3) 15991
15991
Air changes/hour 0.38
0.20
Equipment Total Load (Sen+Lat)
24005
Btuh
Equiv. AVF (cfm) 101
53
Req. total capacity at 0.75 SHR
2.2
ton
Heating Equipment Summary
Cooling Equipment Summary
Make Goodman Mfgg.
Make Goodman Mfg.
Trade GOODMAN; JANITROL; AMANA
DIST[...
Trade GOODMAN; NITROL;
JA
AMANA DIST[...
Model GSZ140301 K
Cond GSZ140301 K
AHRI ref 7995113
Coil ARUF31 B14A
AHRI ref 7995113
Efficiency 8.2
HSPF
Efficiency 12.0 EER,14 SEER
Heating Input
Sensible cooling
21000
Btuh
Heating output 27800
Btuh @ 470F
Latent cooling
7000
Btuh
Temperature rise 0
cF
Total cooling
28000
Btuh
Actual airflow 0
cfm
Actual airflow
933
cfm
Air flow factor 0
cfm/Btuh
Airflowfactor
0.045
cfm/Btuh
Static pressure 0.50
in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.83
Capacity balance poi nt = 33 OF
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-PW wrightsoTt' 2018-Aug-10 09:4320
ACA•�^ � � Right-Sute®Uriversal201818.0.19 RSU23249 Page 1
or\Desktop\TEMP\Lot005 F1833 B RHG Den- E rLp Calc= MJ8 Frond Door faces: E
wrightsoftRight-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwuOneStopCooling.cem License: CAC032444
Job: Lot 005 F1833 B RHG Den.- E
Date: 05/14/2018
By. XF/RI/MC
1
Room name
Entire House
WED
2
3
Exposed ydl
Room height
157.5 ft
8.7 ft d
31.0 ft
8.7 ft heaUcool
4
5
Room dimensions
Room area
1838.0 ft2
14.0 x 17.0 ft
238.0 fly
Ty
Construction
number
U-value
(BtuhAC-'q
Or
HTM
(BtuhM)
Area ("
or perimeter (ft)
Load
(Btuh)
Area ("
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
. _f-
13A-flocs -
4A5-2om
13A-4ocs
4A5-2om
11 DO _ _
13A:4ocs. _ _ ._ _ _
13A-4ocs
4A5-2om
4A5-2omd
12C-Osw
------
16B-30ad
22A-cprlt - - _ - -
0.143
0.540
0.143
0.540
0.390
_ - _ 0.143
0.143
0.540
0.630
0.091
0.390
0.032
1.160
n
_n
a
e
a
_. _s
w
w
- w,
-n_
_- .
3.72
_ 14.04
3.72
14.04
10.14
_ . 3:72
3.72
14.04
16.38
2.37
_ .10.14
_ , 0.83
30.68
2.62
_14.36
2.62
34.14
11.50
_ _' 2.62
2.62
34.14
42.09
1.33
_..11.50
1.70
_0.00
248
.. , . . _ 16
265
49
20
418
439
49
54
344
__18
1838
1838
232
_ 0
196
0
20
_ -_. 418
337
0
0
326
_--.18.__._181
_ 1838
.. 158
861
_ . _ .229
730
688
204
_ 1553
1252
688
- 878
771
, 1529
. 4832
606
235
514
1674
231
_1093
881
1674
- 2256
433
__.-206
, _ _ 3117
- 0
0
. 0
0
0
0
148
122
33
0
0
...0
238
-. 238
0
0
0
0
0
.148
89
0
0
0
0
238
_..31
0
0
0
0
0
550
331
459
0
0
.0
_ ___ _198
991
0
_
.- 0
0
0
0
387
233
1116
0
0
_. _0
404
- 0
-G
LLL
---DDD
W- _ .
V�1
�G
-_(
P
_�.11DO-__.___
C _ _
F. .--,
6
c) AED excursion
807
318
Envelope loss/gain
14396
13726
2489
2458
12
a) Infiltration
2894
1054
570
208
b) Room ventilation
0
0
0
0
13
Internal gains: Oocupants@ 230
4
920
2
460
Applianoesrother
1700
0
Subtotal (lines 6 to 13)
1 17290
17400
30591
3125
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
17290
17400
3059
3125
15
Dud loads
101%
20%
1765
3492
10'/a
20%
312
627
Total room load
19055
20892
3371
3752
Air required (cfm)
0
933
01
168
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-rk- 2018-Aug-1009.4320
At& Right-Scrite®Universal 201818.0.19 RSU23249 Page 1
...or\Desktop\TEMP1Lct005F1833BRHGDen- E.np Calc=MJ8 Front Door faces: E
- wrightsoft Right-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sardscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: w w 0neStopCoolirg.com Liceme: CAC032444
Job: Lot 005 F1833 B RHG Den - E
Date: 05/14/2018
By- WRING
1
Room name
KETH
MWIC
2
3
Exposed well
Room height
14.5 It
8.7 It heatl000l
0 ft
8.7 It heaUcool
4
5
Room dimensions
Room area
1.0 x 109.5 It
169.5 ftz
6.5 x 10.5 It
68.3 IF
Ty
Construction
number
U-value
(BtuW'o
Or
HTM
(Btuh/fM
Area ("
or perimeter (ft)
Load
(Btuh)
Area M
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
NiP/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
1'1
UN
13A-4ocs -
4A5-2om -
13A-4ocs
4A5-2om
11 DO -
13A-4ocs
4A5-2om
0.143
0 540
0.143
0.540
0.390
0.143
0.143
0.540
n
. n-
a
e
_ e
s-
w
w
3. 2
_ 14.04
3.72
14.04
10.14
3.72
3.72
14.04
2.62
14.36
2.62
34.14
11.50
2.62
2.62
34.14
0
_ - 0
0
0
0
.. _ _-126
0
0
0-
0
0
0
0
126
0
0
6
_ . . _ 0
0
0
0
- - _ 469
0
0
0
_0
0
0
0
.330
0
0
0
'. _ ..... 0
0
0
0
0
0
0
- 6
-, _ 0
0
0
0
_ _ _0
0
0
:- 0-
-0
0
0
0
0
0
0
0
0
0
0
0
0
_�.
_
y/
P
4A5.2omd
12C-0sw
_ 0.630
0.091
w
16.38-
2.37
_ _42.09
1.33
-_ ._ _ - 0
0
0
6
_ 0
0
_ 0
0
._ 0
0
,. 0
0
0
0
0
0
D.
C
11 D0 __ _. -.
16B-30ad
0.390
0.032
_ n _
-
.. 10.14.
-1150
1.70
. __ ---0
0
110
A
_ 91
186.
68
0
- .68
_0
57
0
_ 116
-
F
_
22A-cpm
1.180
.
,. _ _0.83
30:66
0.00
- . _ _ -110
110
15
_ -
_445
0
- -. 68
0
- _ 0
0
6
c) AED excursion
-48
-9
Envelope loss/gain
1005
468
57
107
12
a) Infiltration
266
97
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliancesother
0
0
Subtotal (lines 6 to 13)
1271
565
57
107
Lessexternalload
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
1271
565
57
107
15
Dud loads
10%
201/.
130
113
10%
20%
6
21
Total room load
1401
678
63
128
Air required (dm)
0
30
0
6
Calculations approved byACCAto meet all requirements of. Manual J &h Ed.
'+ wrigtitsolFt� 2018-Aug-10 09.4320
�F. Right-SuteO Uriversal 201818.0.19 RSU23249 Page 2
...or\Desldop\TEMP\Lot005F1833BRHGDen -E.np Cale =MJ8 Front Door faces: E
- wrightsoft° Right-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwaOneStopCooling.cem License: CAC032444
Job: Lot 005 F1833 B RHG Den - E
Date: 05/14/2018
By: XF/RI/MC
1
Room name
DEN
FOY
2
3
Exposed wall
Room height
30.0 ft
8.7 ft heaV000l
5.5 ft
8.7 ft heaUcool
4
Roomdimensions
13.5 x 13.0 it
5.5 x 9.0 ft
5
Room area
175.5 ftz
49.5 ftz
Ty
Construction
number
U-value
(BtuW F)
Or
HTM
(Btuh/ftq
Area M
or perimeter (ft)
Load
(Btuh)
Area (M
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
NrP/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
yjJ
13A-4as
4A5-2om --
13A-flocs
4A5-tom
11 DO
13A-4ocs - _ -
13A-40cs
4A5-2om
6.143
0:540
0.143
0.540
0.390
0.143
0.143
0.540
ri -
_ n
a
a
a
- s
w
w
3.72
14.04
3.72
14.04
10_14
_- 3.72
3.72
14.04
- 2.62
14.36
2.62
34.14
11.50
: 2.62
2.62
34.14
-30
- - -- . 0
117
16
0
_ -_ 113
0
0
30
_ - - -- 0
101
0
0
_ 113
0
0
113
. _ 0
376
229
0
-__ . _ 421
0
0
-80
-. _ _ .. -. 0
265
558
0
_ - _ �.296
0
0
0
__0
48
0
20
. 0
0
0
0
0
28
0
20
- -- . -0
0
0
0
-- _ _ _A.
103
0
204
_
0
0
0
_ _ 0
73
0
. 231
0
0
0
W
y/
II�G
PII.
4A5.2omd
12C=osei
0.630
0.091
- w-
-
- 16.38
2.37
. 42.09
1.33
0
0
0
0
.0
0
0
0
0
0
_ 0
0
0
0
0
0
�--D
C_
11D0:- _ -_ ._ _
1613-30ad
..0.390
0.032
. n-
10.14
0.83
-._11.50
1.70
-- .-0
176
_ _.0
,- 176
._ 0
-. 146
_ _ _-0._,-
- 298
-0
50
._.0
50
_ 0
_ 41_
- _ _.0
- 84
_
F
-
22A-cpm-
1.180
- ..-_ _
-
_ k68
_ - _
0.00
, -
- 176
-
30
.- 920
_
0
_50
6
_ 169
0
6
c) AED excursion
8
-33
Envelope loselgain
2205
1504
517
355
12
a) Infiltration
551
201
101
37
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
12757
1705
618
391
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
237
150
-618
-391
14
Subtotal
2993
1854
0
0
15
Ductloads
10/
20%
305
372
101/.
201/.
0
0
Total room load
3299
2227
0
0
Air required (ctm)
0
99
oi
A
Calculations approved bVACCAto meet all requirements of Manual J 0 Ed.
-0}o- wrYg* t cxim- 2018-Aug-10 09.4320
AC�A Right -Suite® Uriversal 201818.0.19 RSU23249 Page 3
...orlDesIdop\TEMP\Lot005F18338RHGDen -E.nQ Cale =MJ8 Front Door faces: E
-�- wrightsoft° Right-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wvAKOreStopCooling.com License: CAC032444
Job: Lot 005 F1833 B RHG Den - E
Date: 05/14/2018
By. XF/RI/MC
1
Room name
DIN
KrF
2
3
Elposed wall
Room height
15.0 ft
8.7 ft heaUmol
0 It
8.7 It heaUmol
4
5
Room dimensions
Room area
11.5 x 12.5 ft
143.8 ftz
1.0 x 297.8 It
297.8 IF
Ty
Construction
number
U-value
(Btuh4tzfl
Or
HTM
(BtuW
Area (M
or perimeter (ft)
Load
(Btuh)
Area M
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
NIPS
Heat
Cool
Gross
NIPS
Heat
Cool
6
13A-4ocs
4A5 tom. -. _ _ . _ -
13A-4ots
0.143
- _- 0 540
0.143
n
n
a
3.72
14.04.
3.72
2.62
_ ..14.36
2.62
0
._- . _ 0
100
0
0
67
0
... - _- 0
250
6
. _ _0
176
0
-- -- 0
0
0
- 0
0
0
0
0
0
0.
0
11
4A5-2om
11 DO
0.540
0.390
e
a
14.04
10.14
34.14
11.50
33
0
0
0
459
0
1116
0
0
0
0
0
0
0
0
0
W_
13A-4ocs: _ _ . - - - -
13A-4ocs
4A5-2om
- - - . 0.143
0.143
0.540
_. s -
w
w
3.72
3.72
14.04
._ 2.62
2.62
34.14
_ - 30
0
0
- - - - 30
0
0
- - -113
0
0
_ . _ _ 80
0
0
- _ - - 0
0
0
. _ 0
0
0
. 0
0
0
- -6
0
0
PI
D.
4A5-2omd-- -
12C-Osw
11DO---_._ . -_- -.-.--
168-30ad
0.630
_ 0.091
.0.390
0.032
w
.n_
16.38
2.37
_-__10.1.4
0.83
42.09
1.33
__.11.50
1.70
0
109
_ --- --0
144
0
109
- 0
144
0
257
_._ __0
_ 120
0
144
__ _ _.0
244
0
61
- 0
298
0
61
---0
298
0
144
--- ._..._0
- -. 248
0
81
.._. - -0
505
'.._
C,
_
F.
22A-cpm - -- ----- -- -
- --- 1..180
r
_ 30.68..
- 0.00
144
_.1_.5.
,
460
0
_ 298
0
. _ 0
0
6
c) AED excursion
136
-140
Envelopeloss/gain
1660
1896
392
446
12
a) Infiltration
276
100
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
1200
Subtotal (lines 6 to 13)
1935
1996
392
1646
Less external load
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
237
150
145
92
14
Subtotal
2172
2146
536
1738
151
Ductloads
10%
20%
222
431
101%
20%1
55
349
Total room load
2394
2577
591
2086
Air required (cm)
1
0
115
0
93
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-rw 2018-Aug-10 09:4320
At& Right-SuiteOUniversal 2018 18.0.19 RSU23249 Page 4
....ADesktop\TEMP1Lot005F1833BRHGDen- E.rup Calc=MA Front Door faces: E
-�- wrightsoftRight-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove Cart, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wewvOreStopCooling.com License: CAG032444
Job: Lot 005 F1833 B RHG Den - E
Date: 05/14/2018
By: XF/RI/MC
1
Room name
GRT
BTH1
2
Exposed wall
16.5 ft
6.0 ft
3
Room height
8.7 ft heaUeool
8.7 It heaticool
4
Room dimensions
16.5 x 15.5 ft
1.0 x 79.5 It
5
Room area
255.8 ftz
79.5 fl2
Ty
Construction
U-value
Or
HTM
Area (ft�
Load
Area (f22)
Load
number
(Btuh/tz'F)
(BtuhAtz)
,
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
NIPS
Heat
Cool
Gross
NrPnS
Heat
Cool
6
W.. _
13A-4ocs
0.143
n
5J7
- 2.62
0
0
0
0
0
0
0
0
4A572om_
0540
n
14.04
14.36
0
__ 0
0
_ _ 0
0
0
._G
13A-4ocs
0.143
a
3.72
2.62
0
0
0
0
0
0
0
0
4A5-2om
0.540
e
14.04
34.14
0
0
0
0
0
0
0
0
11
11 DO
0.390
a
10.14
11.50
0
0
0
0
0
0
0
0
- -- cs_ -
13A-4a
---143__-
0
s_ -
-- .3.72_
. _ _ .2:62
- _ ...
0
-
_ _ .. 0
-
_ _ -0
'. .. • _.. 0
_ '0
.. _ ,. 0
.. ._ 0
.. 0
v�f
.-
13A-4ocs
0.143
_
w
-
3.72
2.62
144
90
334
235
52
52
194
137
4A5-2om
0.540
w
14.04
34A4
0
0
0
0
0
0
0
0
4A5-2omd.
0.630
w
16.38
42.09
54
0
878
2256
0
0
0
0
�0
f
12C-Osw
0.091
2.37
_
1.33
6
_ _
0
_ _
0
0
0
0
0
_ 0.390
-n-
_ 10.14
_ :_11 50
_- ---..-.0
0
:_ _
_.. 0
_0
. _ _ 0
__. _ _0
O
1613-30ad.
0.032
0.83
1.70
256
- 256
213
-- 434
_ 80
80
-_ 66
_ 135
-_ _
2PA-cpm _
1.180
_ 30.63
_ _
0.00
256
17
506
0
80
6
_ 184
- 0
6
c) AED excursion
640
-24
Envelope loss/gain
1931
3565
444
247
12
a) Infiltration
303
110
110
40
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliancesbther
0
0'
Subtotal (lines 6 to 13)
2235
3676
555
287
Lessexternalload
0
0
0
0
Less transfer
0
0
0
0
Redistribution
5
9
8
15
14
Subtotal
2239
3685
563
302
15
Dud loads
10%
200/.
229
740
10%
200/6
57
61
Total room load
2468
4424
620
363
Air required (cfm)
0
198
0
16
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-�+ wr7g1ht:M.MI - 2018-Aug-10 09.4320
Right -Suite® Uriversal 201818.0.19 RSU23249 Page 5
...orlDesktop\TEMP\Lot005 F1833 B RHG Den- E.rup Calc= MA Front Door faces: E
-11- wrightsoft° Right-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sardscove CoA Winder Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wvmOneStopCooling.cem License: CAC032444
Job: Lot 005 F1833 B RHG Den - E
Date: 05/14/2018
By: XF/RI/MC
1
Room name
BED2
AC
2
3
4
5
Exposed wall
Room height
Room dimensions
Room area
26.0 ft
8.7 It heat/cool
1.0 x 160.5 ft
160.5 ftz
0 It
8.7 It heat/cool
5.5 x 3.5 ft
19.3 ft2
Ty
Construction
number
U-value
(Btuh/ft-9
Or
HTM
(BtuW)
Area (n
or perimeter (ft)
Load
(Btuh)
Area (ft9
or perimeter (ft)
Load
(Btuh)
Heat
Coal
Gross
N/P)S
Heat
Cool
Gross
NtPIS
Heat
Cool
6
11
V!/
.._..
13A-oa--_ts _ . -
4A5.2om-
13A-4ots
4A5-2om
11DO -
13A:4acs
13A-4ocs
4A5-2om
4A5-2omd
12C-Osw
- - --- 0.143
'-W
0.143
0.540
0.390
-
_._0.143
0.143
0.540
0.630
0.091
n
..n
a
e
a
- .
.s .
w
w
, w
-
_ _ 3.72
14.04
3.72
14.04
10.14
---
_ 3.72
3.72
14.04
1.6.38
2.37
2.62
14.36
2.62
34.14
11.50
---._
_. 2.62
2.62
34.14
42.09
1.33
104
_ 0
0
0
0
....... _...
0
122
16
0
0
_ 104
0
0
0
.. 0
_ 0
105
0
0
0
_ 388
--- 0
0
0
0
.. - - -._0
392
229
0
0
273
-_ - 0
0
0
0
_0
276
558
0
0
0
.- _ 0
0
0
0
--
0
0
0
0
0
0
_ --.0
0
0
0_
-.. - 0
0
0
0
0
0
,-_ - 0
0
0
0
_ 0
0
0
0
0
0
0
0
0
_ 0
0
0
0
0
0
W _ LL
v�
�-G
PII
-
.11D0_. _ _
1613-30ad -
__ 0.390
0.032
1.180
..n_
= _
.-_..10.14
_ _0.83
_ 30:68
-._1150
- _ 1.70
6.00
__0
_ 161
161
_ .0
_ 161
26
_ 0
.134
798
10
272
0
.- __0
_ 19
.. 19
_0
19
_ , . 0
-. .0
i 6
- - -0
_ .. 0
- 33
0
IJ
C ._
6
c) AED excursion
129
-3
Envelope loss/gain
1941
1508
16
30
12
a) Infiltration
478
174
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Oaupants@ 230
1
230
0
0
Applianceslother
0
0
Subtotal (lines 6 to 13)
2419
1913
16
30
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
5
9
-16
-30
14
Subtotal
2423
1921
0
0
15
Dud loads
10%
201%
247
386
10%
20%
0
0
Total room load
2671
2307
0
0
Air required (cfm)
0
103
0
0
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
- wrigF�tsoit ° 2018-Aug-10 09:4320
Right-SLiteDUriversal 20l8 i8.0.19 RSU23249 Page 6
...or\Desldop\TEMP\Lot005 F1833 B RHG Den- E.rup Calc= MJ8 Front Door faces: E
-F� wrightsoftRight-J® Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove Curt, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwvzOneStopCooling.com License: CAC032444
Job: Lot 005 F1833 B RHG Den - E
Date: 05/14/2018
By- XF/RIIMC
1
Room name
BED3
LAUN
2
3
Exposed well
Room height
13.0 it
8.7 ft heaV000l
0 it
8.7 ft heaYbool
4
5
Room dimensions
Room area
1.0 x 156.3 it
156.3 ftz
1.0 x 51.3 it
51.3 fl2
Ty
Construction
number
U-value
(Btuhrftz'q
Or
HTM
(Btuw)
Area
or perimeter (it)
Load
(Btuh)
Area (ft)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross .
NAS
Heat
Cool
6
11
T. G
13A-4ocs
4A5-2om , - _ _. _ ._.
4A5-2om
11DO - -
13A--4o(s, -
13A-4ots
4A5-2om
4A5-2cmd _
12C-0 m
0.143
_ ___ _ 0.540
0.143
O-W
_ 0_390
0.143
0.143
0.540
0.630
0.091
n
. n
a
e
e_
s .
w
w
w
3.72
.14.04
3.72
14.04
_ 10.14
3.72
3.72
14.04
16.38
2.37
2.62
14.36
2.62
34.14
1150
2.62
2.62
34.14
_ 42.09
1.33
113
16
0
0
0
-. - -
0
0
,- - . 0
117
47
_10
0
0
0
0
0
. -0
117
36d
229
0
0
0
0
0
0
278
253
. 235
0
0
- _ 0
0
0
0
0
156
6
0
0
0
_0
- .. _ . 0
0
0
_ 0
57
0
0
0
0
0
0
0
0
0
39
0
0
0
0
0
0
0
0
0
051
0
0
0
0
0
- _ _ 0
0
0
0
_
ILE13A-4ocs
-
W _
PI
D.
11D0._ _. _- . _. _
1613-30ad _ -
22A-cpm
: - 0.390
0.032
1.180
n
_ --
10.14
0.83,
30.68
_11.50
_ _ 1.70
. _._ 0.00
_ ..._.0
- - 156
156
_ _..0
156
- . - 13
__0
- _ 130
399
_ _. _ -0
_ _ 265
0
.18
51
51
- _ _ 18
_ 51
0
_ 181
43
0
206
87
0
'
C _ - -
F
6
c) AED excursion
-96
-66
Envelopelosslgain
1396
813
315
278
12
a)- Infiltration
239
87
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: 0ocupants@ 230
1
230
0
0
Appliances/other
0
500
Subtotal (lines 6 to 13)
1635
1130
315
778
Less external load
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
13
25
13
25
14
Subtotal
1648
1154
328
802
15
Ductloads
101/
20%
168
232
101%
20%
34
161
Total room load
1816
1386
362
963
Air required (dm)
0
62
0
43
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
44r 2018-Aug-1009:4320
Right-SUte®Universel 201818.0.19 RSU23249 Page 7
or\Desktop\TEMP\Lot005F1833BRHGDen- E.rLp Calc=MJ8 FrontDoorfaces: E
- wrightsofV Right-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling.com License: CAC032444
Job: Lot 005 F1833 B RHG Den - E
Date: 05/14/2018
By: XF/RI/MC
1
Room name
H1
2
EVosed wall
0 ft
3
Room height
8.7 ft heaV000l
4
Room dimensions
9S x 3.5 It
5
Room area
33.3 ft2
Ty
Construction
U-value
Or
HTM
Area (ft�
Load
Area
Load
number
(Btuh4t2-F)
(Btuhuf2)
or perimeter (ft)
(Btuh)
or perimeter
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/PVS
Heat
Cool
6
1M -
13A-4ocs
0.143
n
3.72
2.62
0
0
0
0
4A5-2om
13A-4ocs
10.540
0.143
n
a
14.04
3.72
14.36
2.62
- - 0
0
0
0
. _ _ 0
0
- 0
0
__ _
11
4A5-2om
11 DO
MAU
0.390
a
a
14.04
10.14
34.14
11.50
0
0
0
0
0
0
0
0
jN
Vl/
13Aa4ocs-- _
13A-4ocs
4A5-2om
-- 0.143
0.143
0.540
_ s_
w
w
.._ _ 3.72
3.72
14.04
: --2.62
2.62
34.14
.: . _ _ 0
0
0
_ 0
0
0
- _ . 0
0
0
-- _ 0
0
0
-
L�—CC
_
P
4A5.2cmd
12C-0sw
0.630
6.091
w
-
16.38
2.37
42.09
1.33
0
0
0
0
0
0
O
0
11130_._-.
1613-30ad-
_ 0.390
0.032
n
10.14
0.83,
11.50
1_.70
-- 0
33
0
33
. . . . - 0'--
28
_ -0
- _ _ 56
-
.
C
F -
_
22A-cpm_ . - -. ._ _
1.180
- _ _
-
30,68
_-
. 0.00
33
0
0
..._ 0
_ ..
6
0) AED excursion
-4
Envelopelossrgain
28
52
12
a) Infiltration
0
0
b) . Roomventilation
0
0
13
Internal gains. Occupants@ 230
0
0
Appliances/other
0
Subtotal (lines 6 to 13)
28
52
Less external load
0
0
Lesstransfer
0
0
Redistribution
-28
-52
14
Subtotal
0
0
15
Duct loads
10%
20%
0
0
Total room load
0
0
Air required (dm)
0
0
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
.�„ —41- 2018-Aug-10 09A320
1015A Right-SUte9Uriversal201818.0.19RSU23249 Page
...orTesktoplTEMP\Lot005F1833BRHGDen- E.np Calc=W8 Front Door faces: E
Static Pressure and Friction Rate Job: Lot005 F1833 B RHG Den...
- :1- wrightsoft, Date: 05/14/2018
Entire House By. XF/RI/MC
One Stop Cooling and Heating
7225 Sandscove Cout, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wawOneStopCooling.com License: CAC032444
Project• •
For: Ryan Homes
5376 OAKLAND LAKE CIR, FT. PIERCE, FL
Available Static Pressure
Heating
Cooling
(in H2O)
(in H2O)
External static pressure
0.50
0.50
Pressurelosses
Coil
0
0
Heat exchanger
0
0
Supply diffusers
0.03
0.03
Return grilles
0.03
0.03
Filter
0.10
0.10
Humidifier
0
0
Balancing damper
0
0
Other device
0
0
Available static pressure
0.34
0.34
Total Effective Length
Supply Return
(ft) (ft)
Measured length of run -out 9 0
Measured length of trunk 20 0
Equivalent length of fittings 120 0
Total length 149 0
Total effective length 149
I
Heating
Cooling
(i n/100ft)
(in/1 001t)
Supply Ducts 0.228 > 0.18
0.228 > 0.18
Return Ducts 0.228 > 0.18
0.228 > 0.18
Supply 4X=35,11 A=20,11 G=5,11 G=5,11 G=5,1 A=35,11 G=5,11 G=5,11 G=5: Total EL=120
Return TotalEL=O
-*- wrightsoft- 2018-Aug-10 09*4321
R1g1t-SUte®Uriversa1201818.0.19RSU23249 Pagel
ACCA ...oADesktop\TEMPU.ot 005 F1833 B RHG Den- E.np Calc= W8 Front Door faces: E
Duct S SJob: Lot 005 F1833 B RHG Den...
-�- wrightsoft° System Date: 05/14/2018
Entire House By. XF/RI/MC
One Stop Cooling and Heating
7225 Sandscove Coin, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: tiw wOreStopGooling.com License: CAC032444
Project• •
For: Ryan Homes
5376 OAKLAND LAKE CIR, FT. PIERCE, FL
External static pressure
Pressurelosses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.50
in H2O
0.16
in H2O
0.34
in H2O
0.170 / 0.170
in H2O
0.228
in/100ft
0
cfm
IE11.1
Cooling
0.50 in H2O
0.16 in H2O
0.34 in H2O
0.170 / 0.170 in H2O
0.228 in/100ft
933 cfm
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BED2
c 2307
0
103
0.291
6.0
Ox 0
VIFx
12.0
105.0
sti
BED3
c 1386
0
62
0.301
6.0
Ox 0
VIFx
12.8
100.0
sti
BTH1
c 363
0
16
0.262
4.0
Ox0
VIFx
15.0
115.0
sti
DEN
c 2227
0
99
0.233
6.0
Ox0
VIFx
36.2
110.0
st2
DIN
c 2577
0
115
0.231
6.0
Ox 0
VI Fx
37.2
110.0
st2
GRIT
c 4424
0
198
0.228
8.0
Ox0
VIFx
29.2
120.0
st2
KIT
c 2086
0
93
0.253
6.0
Ox 0
VIFx
24.6
110.0
st2
LAUN
G, 963
0
43
0.466
4.0
Ox 0
VIFx
3.0
70.0
MBED
c 3752
0
168
0.230
7.0
Ox 0
VIFx
32.8
115.0
st2
MBTH
c 678
0
30
0.239
4.0
Ox0
VIFx
32.5
110.0
st2
MWic
c 128
0
6
0.249
4.0
Ox0
VIFx
26.8
110.0
st2
Supply Trunk Detail Table
Trunk
Htg
Cig
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
s2
PeakAVF
0
709
0.228
663
14.0
0 x 0
VnlFIX
sti
PeakAVF
0
181
0.262
678
7.0
0 x 0
VinIFIX
-�- wrightsoft® 2018-Aug-10 09:4321
1 �wMHIBnSMnwrAw..... Right-Sute®Uriversal2018 18.0.19 RSU23249 Page 1
ACC(...or\Desldop\TEMP\Lot005F1833BRHGDan- E.rLp Calc=MJ8 FrordDooriaces: E
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Mat
Trunk
rbi
Ox 0
0
933
0
0
0
0
Ox 0
VIFx
* wrightsoft® 2018-Aug-10 09:4321
A—t Right-Sute®Uriversal201818.0.19 RSU23249 Page 2
/CCK ...cADesIdop\TEMP\Lot 005 F1833 B RHG Den- E.np Calc= MA Front Door faces: E
EF1 = 50 CFM Fan
EF2 = 80 CFM Fan
EF3 =110 CFM Fan
EFL1 = 50 CFM Fan
EFL2 = 80 CFM Fan
EFL3 =110 CFM Fan
VTR = Vent to Roof
VTW = Vent to Wall
DV = Dryer Vent
RV = Range Vent
= Lineset Chase — —
= Condensate — - —
= Thermostat 18/8 OT
SRB = Small Reduction Box
LRB = Large Reduction Box
FBB = Field Built Box
Job #: Lot 005 F18M B RHG Den - E
Performed by XF/RUMC for:
Ryan Homes
5376 OAKLAND LAKE CIR
FT. PIERCE, FL
Level 1
AC PADS BYGC MIN SIZE
4TX40r
W SEPARATION
16' OFF WALL
" PVC REFRIG LINE CHAS S
BYGC
One Stop Cooling and Heating
7225 Sandscove Court
Winter Park, FL 32792
Phone: (407) 629 - 6920 Fax: (407) 629 - 9307
w u0neStopCooling.com
Scale:1 : 71
Pagel
Right Suite® Universal 2018
18.0.19 RSU23249
2018•Aug-10 09:44:59
lot005 F1833 B RHG Den- E.rup