FIELD AND LABORATORY REPORT COVER PAGE
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Estates Subdivision House Lot Investigation Lot 5
5376 Oakland Lake Circle, Ft. Pierce, St. Lucie County, FL
RECEIVED
OEC:21 2018
=ermitting Departmen
., Lucie County
As requested, Universal Engineering Sciences, Inc. (UES) representative(s) performed construction materials testing and/or
field inspection services on the above project.. Testing results and/or inspection observations are reported on the attached
sheets. The contents of this package,are summarized below:
Scope of Work
Work Order No.
Date
Type of Report
66331-1
10/11/2017
In -Place Density Test Report w/Activity Record
We hope this information
the undersianed.
is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact
Sincerely,
Universal Engsnee_rling,Sciences, Inc.
Certificate of Auth6riza'd ,n No. 000005 49
� 1
Richard E. Hoaglin, P.E.
FLORIDA
Professional Engineer No. 48796
ICC Email: jomcalli@nvrinc.com; tridley@nvrinc.com
Activity Record
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Estates Subdivision House Lot Investigation
Oakland Lake Circle, Ft. Pierce, St. Lucie County, FL
Date of Activity: Wednesday, 11 October, 2017
Technician: Cliff Cherrnay
As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for
the, purpose of earthwork testing for Lot 5.
DENSITY TEST
While on site, the technician observed the general condition of the areas to be tested and performed 1 density test for Lot 5 at
5376 Oakland Lake Cir. This test was performed in accordance with the ASTM D-6938 Nuclear Gauge Method and found
to meet the project compaction requirements of 95% of the maximum dry density per ASTM D-1557.
BEARING CHECK
Technician also hand augered to a depth of 5' and no organic material was found.'
The fill soils appear to be suitable, granular materials without expansive clays and are in accordance with
the assumed building code soil conditions of 2,000 psf that the designer noted was used for design of the foundations.
UNIVERSAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences,
Geophysical,5eniices •;Materials,Testing' • Threshold;lnspection
Building -Code Administration,.Com' pliance Inspection & Plan Review,
820 Brevard Avenue, Rockledge, FL 32966 - P: 321.638.0808 - F: 321.638.0978
UES Project No: 0310.1700455.0000
UES DOCS No:
UES. Report No: 66331-1 DT 101117
In -Place Density Test Report
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Estates Subdivision House Lot Investigation
Oakland Lake Circle, Ft. Pierce, St. Lucie County, FL
Area Tested: Lot 5
Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 10/11/2017
Lab: ASTM D1557 Modified Proctor
Technician: Cliff Cherrnay
Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
oniv and do not address the condition of the underivina soils below the tested deaths.
Field Dry
Field
Test
Depth
Proctor
Density
Moisture
%
Comments
No.
Location of Test
Range
(inch)
(2)
(PCF)
%
Compaction
(3)
1
Lot 5
0-1 ft
12.00
7492
115.5
13.8
100
A
(1) Ref. Datum: 0 = Top of Final Grade
(2)
Maximum
Optimum
Proctor
Dry
Moisture
#
Density
Content
7424
115.0
12.0
This test was performed without deviation from ASTM procedures.
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested,'Meets Requirements
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.
u's
UNIVERSAL
No.:
Date Typedt
Aug t 27?2018023
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
! 0 6 G 0
0
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Construction Materials Testing Services
FIELD AND LABORATORY REPORT COVER PAGE
RECEIVED
Client: Ryan Homes
AUG 3 1018
1450 Centrepark Blvd Suite 340
permitting t)e
West Palm. Beach, FL 33401
St. Lucie cou�tyent
Project: Oakland Lake Subdivision Lot 5
5376 Oakland Lake Circle Permit # 18060500, Fort Pierce, St. Lucie County, FL
As requested, Universal Engineering Sciences, Inc. (UES) representative(s) performed construction
materials testing and/or
field inspection services on the above project. Testing results and/or inspection observations are
reporte&on the attached
sheets. The contents of this package are summarized below:
Scope of Work
Work Order No: Date Type of Report
100053-1 08/24/2018 In -Place Density Test Report w/Activity Record
We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact
the undersigned.
Attachments (1)
Sincerely, l'
UniversaVE' ig"m4anng Sciences, Inc.
Certificate, rf,Ai"!thorzatio `a:0000 Et49�
Air
Richard, Richard E. Hoaglin, P.E.
FLORIDA
Professional Engineer No. 48796
This item has-been electronically signed and sealed by
Richard E. Hoaglin, P.E. using a Digital Signature. Printed
copies of this document are not considered signed and
sealed and the signature must be verified on any electronic
copies.
ICC Email: cbugg@nvrinc:com; elibrihi@nvrinc:com; Imhoff, Bryan [BIMHOFF@nvrinc.com]; jomcalli@nvrinc.com; rofingar@nvrinc.com; sign/seal MAIL to
ryan homes at 1777 Willows Square, Vero Beach, FL 32966
Revised May 2015
N
' ERSA
'_ I UES ►4j2ct No: 0310.1700251.0023
UES DOCS No:
UES Report No: 100053 1 ARC 082418
N1ENGINEERING SCIENCES On-SiteTime (hrs):1.00
Consultants In: Geotechnical Engineering @ Environmental Sciences Lab Time (hrs): 0.00
Geophysical Services - Materials Testing , Threshold Inspection Travel Time (hrs): 1.00
Building Code Administration, Compliance Inspection & Plan Review Total Time (hrs): 2.00
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Activity Record
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Subdivision Lot 5
5376 Oakland Lake Circle Permit # 18060500, Fort Pierce, St. Lucie County, FL
Date of Activity: Friday, 24 August, 2018
Technician: Cliff Cherrnay
As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of
earthwork testing for the House pad.
While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for House
pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet the
project compaction requirements of 95% of the maximum dry density per ASTM D-1557.
The Contractor was notified of the test results or a copy was left for their records.
UES Project No: 0310.1700251.0023
UNIVERSAL UES DOCS No:
ENGINEERING SCIENCES UES. Report No: 100053-1 DT 082418
Consultants In: Geotechnical Engineering Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue,: Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
In -Place Density Test Report
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Subdivision Lot 5
5376 Oakland Lake Circle Permit # 18060500, Fort Pierce, St. Lucie County, FL
Area Tested:' House pad
Type of Test: Field: ASTM D-6938 Nuclear Gauge Method 'Date of Test: 08/24/2018
Lab: ASTM D1557 Modified Proctor
Technician: Cliff Cherrnay
Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
only and do not address the condition of the underlvinq soils below the tested depths.
Test
No.
Location of Test
Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
%
Compaction
Comments
(3)
1
N/W test
0-1 ft
12.00
21180
109.1
11.5
97
A
2
S/W test
0-1 ft
12.00
21180
107.6
13.0
96
A
3
S/E test
0-1 ft
12.00
21180
108.8
11.6
97
A
4
N/E test.
0-1 ft
1 12.00
21180
107.5
1 11.9
96
A
(1) Ref. Datum: 0 = Top of Final Grade
(2)
Maximum
Optimum
Proctor
Dry
Moisture
#
Density
Content
21180
112.0
11.0
This test was perfdfined without deviation from ASTM procedures.
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet•min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This report shall not be reproduced, except:in full, without the written approval of Universal Engineering Sciences:
031u.1
UNIV, I R S A L Date
Project No.: August 7,251.0023
Date Typed: August 27, 2018
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services r Materials Testing r Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Construction Materials Testing Services
FIELD AND LABORATORY REPORT COVER PAGE
Client: Ryan Homes
RECEIVED
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
AUG 2 7101g
Project: Oakland Lake Subdivision Lot 5
5376 Oakland Lake Circle Permit # 18060500, Fort Pierce, St. Lucie County, FL
Permitting Departmenr
St. Lucle County
As requested, Universal Engineering Sciences, Inc. (LIES) representative(s) performed construction
materials testing and/or
field inspection services on the above project. Testing results and/or inspection observations are reported on the attached
sheets. The contents of this package are summarized below:
Scope of Work
Work Order No. Date Type of Report
100053-1 1 08/24/2018 In -Place Density Test Report w/Activity Record
We hope this, information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact
the undersigned.
Attachments (1)
Sincerely,
Universal Engineering Sciences, Inc.
Certificate of Authorization No. 00000549
Richard E.
Hoaglin, P.E.
2018.08.27
13:34:28
l�
Richard E. Hoaglin, RE,
FLORIDA
Professional Engineer No. 48796
F
is item has been election/cally Signed aadS@a/edby
chard E. Hoaglin, p,E„sing a Digital S/gnature. PrlH�@Or
coppies of this document are not considered sighed and
es and the signature must be verified on any eiectron/L
ICC Email: cbugg@nvrinc.com; elibrihi@nvrinc.com; Imhoff, Bryan [BIMHOFF@nvrinc.com]; ]omcalli@nvnnc.com; rofln ar
ryan homes at 1777 Willows Square, Vero Beach, FL 32966
9 @nvrinc.com; sign/seal MAIL to
Revised May
FIN
—=� UES I���.,aCtct No: 0310.1700251.0023 .
UNI.VNIIIIIIIIIRSAL UES DOCS No:
UES Report No..
100053-1 ARC 082418
ENGINEERING SCIENCES On -Site Time (hrs): 1.00
Consultants In: Geotechnical.Engineering • Environmental Sciences Lab Time (hrs): 0.00
Geophysical Services • Materials Testing • Threshold Inspection Travel Time (hrs): 1.00
Building CodeAdministration,Compliance Inspection &Plan Review Total Time (hrs): 2.00
820.13revard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Activity Record
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Project: Oakland Lake Subdivision Lot 5
5376 Oakland Lake Circle Permit # 18060500, Fort Pierce, St. Lucie County, FL
Date of Activity: Friday, 24 August, 2018
Technician: Cliff Cherrnay
As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of
earthwork testing for the House pad.
While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for House
pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet the
project compaction requirements of 95% of the maximum dry density per ASTM D-1557.
The Contractor was notified of the test results or a copy was left for their records.
Iz
, 1
U N.1 V-15 RSA L
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955 P: 321.638.0808 - F: 321.638.0978
Client:
Project:
Area Tested:
Type of Test:
Technician:
Requirements:
In -Place Density Test Report
LIES Project No: 0310.1700251.0023
UES DOCS No:
UES Report No: 100053-1 DT 082418
Ryan Homes
1.450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Oakland Lake Subdivision Lot 5
5376 Oakland Lake Circle Permit # 18060500, Fort Pierce, St. Lucie County, FL -
House pad
Field: ASTM D-6938 Nuclear Gauge Method
Lab: ASTM D1557 Modified Proctor
Cliff Cherrnay
Date of Test: 08/24/201.8
95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
only and do not address the condition of the underlvina soils below the tested depths.
Test
No.
Location of Test
Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
%
Compaction
Comments
(3)
1
N/W test
0-1 ft
12.00
21180
109.1
11.5
97
A
2
SM test
0-1 ft
12.00
21180
107.6
13.0
96
A
3
S/E test
0-1 ft
12.00
21180
108.8
11.6
97
A
4
1 N/E test
0-1 ft
12.00
21180
107.5
11.9
96
A
(1) Ref. Datum: 0 = Top of Final Grade
(2)
Maximum
Optimum
Proctor
Dry
Moisture
#
Density
Content
21180
1,12.0
11.0
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This test was performed without deviation from ASTM procedures.
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.