HomeMy WebLinkAboutENERGY EFFICIENCY CODE. N -c)(0 --- SCANNkU FORM R405-2017��99�F���9��0�` FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE MAJESTIC Builder Name: Street: THE MAJESTIC ( City, State, Zip: FT. PIERCE, FL,- v�\��� Permit Office: ST. LUCIE COUNTY Permit Number: Owner: WYNNE DEV. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1512.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1128.00 ft2 b. Frame - Wood, Exterior R=11.0 384.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1608.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1608.00 ft2 6. Conditioned floor area above grade (ft2) 1608 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(141.9 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 275 a. U-Factor: Sgl, U=0.54 101.94 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.254 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1608.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1608.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.088 Total Proposed Modified Loads: 50.22 PASS Total Baseline Loads: 50.28 I hereby certify that the plans and specifications covered by Review of the plans and %EKE Si - this calculation are in compliance with the Florida Energy specifications covered by this �yO _ �0�,. Code. calculation indicates compliance - yk a,,r���''� -' �•�' �� with the Florida Energy Code. nn�, ?�"%.:; jam•;:••. ���,� O PREPARED BY: Before construction is completed - DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance the Florida Energy Code. Florida Statutes. cob with OWNER/AG BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COPY 6/27/2018 1:24 PM EnergyGauge@) USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INFLI I SUMMAKY (. NLUKL1, I Kr-VUK I PROJECT Title: WYNNE THE MAJESTIC Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1608 Lot # Owner Name: WYNNE DEV. Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 225 Street: THE MAJESTIC Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1608 12864 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 238 1904 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 589 4712 No 0 1 Yes Yes Yes 8 KITCHEN 228 1824 Yes 0 1 Yes Yes Yes 9 BATH 2 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 82 656 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 38 ft 0 238 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 ____ 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft2 _--- 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ---- 0 1 0 6/27/2018 1:24 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT 5UMMAKY (:lit(:KL.I5 I KtPUK I FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist k-Value Tile Wood Carpet 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 589 ft2 ---- 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 12 ft 0 228 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 2 5 ft 0 50 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 ---- 0 1 0 11Slab-On-Grade Edge Insulatio FOYER 9 ft 0 82 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1695 ft2 0 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1608 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 238 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 589 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 228 ft2 0.1 Wood 9 Under Attic (Vented) BATH 2 30 Blown 50 ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 82 ft2 0.1 Wood WALLS Ornt Adjacent Space CavR_Vaity Width TO Wall T_ Height Sheathing Framing Solar Below 1 NE=>W Exterior Concrete Block - Ext Ins)JASTER BE 4.1 17 0 8 0 136.0 ft2 0 0 0.5 0 2 SW=>E Exterior Concrete Block - Ext InsMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 _ 3 NW=>S Exterior Concrete Block - Ext InsMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 4 NE=>W Exterior Concrete Block - Ext IndUASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 5 NE=>W Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 6 NE=>W Exterior Concrete Block - Ext InMEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0 7 SW=>E Exterior Concrete Block - Ext IndXNING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.5 0 8 NW=>S Exterior Concrete Block - Ext IndANING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0 6/27/2018 1:24 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 r:r)PRn Ranr%_9nl7 IMPI IT Al IMMARY CHFCKI IRT REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Z Ornt In Wall Typepace Sle In Et In Area R-Value Er-artonn AhSnr Grade% 9 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0 10 NE=>W Exterior Concrete Block - Ext Insul BATH 2 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 13 N=>SW Exterior Frame - Wood MASTER BE 11 26 8 208.0 ft2 0.23 0.5 0 14 E=>NW Exterior Frame - Wood MASTER BE 11 11 8 88.0 ft2 0.23 0.5 0 15 W=>SE Exterior Frame - Wood MASTER BE 11 11 8 88.0 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft 'In 1 SE=>N Insulated FOYER None .28 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.54 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.54 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.54 0.25 N 16.4 ft2 1 ft 0 in 1 ft 4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 N 20.6 ft2 1 ft 0 in 1 ft 4 in None None 5 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 N 25.1 ft2 1 ft 0 in 1 ft 4 in None None 6 NW=>S 8 Metal Low-E Single Yes 0.55 0.25 N 40.0 ft2 9 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1040 ft2 1040 ft2 48 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1500.8 82.39 154.95 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 6/27/2018 1:24 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 4 of 5 't FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS — Supply — ---- Return -- Air CFM 25 CFM25 HVAC # V/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 275 ftZ Attic 85 ftZ Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb Mar Apr Mn Jun X Jul Au Se Oct Nov Dec Jan Feb Venting Mar �X� pr Jun Jul ri A rj Oct Nov JXJ Dec Jan Feb X Mar Ae May Jun Jul Aug Sep Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (VVD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftZ Oft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ftz ft 0.3 WIC Default(8 Ibs/sq.ft. ftZ ft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ftz ft 0.3 M. BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUDRY Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ftz ft 0.3 DINING/GREAT R Default(8 Ibs/sq.ft. ftZ ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ftz ft 0.3 HALL Default(8 Ibs/s .ft. ftz ft 0.3 FOYER Name: Test Rater i�'i%1 a��l�'/l/ • �� Rating Compant: Test Rater Date: 0 "��—� 6/27/2018 1:24 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 2617 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE MAJESTIC Builder Name: Street: THE MAJESTIC Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: U Owner: WYNNE DEV. Jurisdiction: w Design Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind popong and wiring- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceiling a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. 6/27/2018 1:24 PM EnergyGaugeO USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 7 '2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1608 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.543 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 34.8 c) Area 7c. 141.9 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 11.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: THE MAJESTIC City/FL Zip: FT. PIERCE. FL > ACA 1 6/27/2018 1:24:14 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 -- wrightsoft° Project Summary Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 172466-6799 Fax 772-466-6796 Email: QUICKCALCS APL.COM- • - Information For: WYNNE DEV. THE MAJESTIC, FT. PIERCE, FL Notes: � o (�a� Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17339 Btuh Structure 17620 Btuh Ducts 5899 Btuh Ducts 8920 Btuh Central vent (0 cfm) 0 Btuh Central vent (0, cfm) 0 Btuh e) Humnone idification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23239 Btuh Use manufacturer's data n Rate/swing multiplier Equipment 0.95 Infiltration sensible load 24643 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3339 Btuh Ducts 2433 Btuh Central vent (0 cfm) 0 Btuh Heating Area Coolingg (none) (ft2) 1608 1608 Equipment latent load 5772 Btuh Volume (W) 13924 13924 Air changeslhour 0.38 0.20 Equipment total load 30415 Btuh Equiv. AVF (cfm) 88 46 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25H BC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Airflow factor Static pressure Space thermostat. Capacity balance point = 32 OF 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm 0.050 cfm/Btuh 0.50 in H2O Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.82 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrightsoft` Right -Suite® Universal 201717.0.14 RSU08101 2017-Apr-11 09:28:14 ACCA Page 1 ...k CaIcslDocumentslWYNNE-MAJESTIC MODEL-1608.rup Calc = MJB Front Door faces: N wrightsoft Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@\OL.COM 1 Room name Entire House MASTER BEDROOM 2 E)q)osed wall 141.0 ft 46.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 294.0 ft 5 Room area 1608.0 ft2 294.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft'-°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AAocs 0.143 ne 4.00 2.55 454 408 1634 1039 56 56 224 143 4A5.2om 0.770 ne - 21.56 36.90 21 0 446 764 0 0. 0 0 4A5-2om 0.770 : ne 21.56 . 36.90 25 0 543 930 0 0 0 . 0 11 y/ -D 13A4ocs 1100 0.143 0.390 se se 4.00 10.92 2.55 11.31 64 23 41 23 165 248 105 257 0 0 0 0 0 0 0 0 13A4ocs_ " 1Ac1oirr 0.143 1.270 sw.. ='sw. 4.00 35i56 2.55 42 91 392, 7 369 5 1476 -" 247 939 . ... 298 -200 " 0 200 0 801 ` A 509: 0 1Ax1om 1.270 ;sw- 35:56 , 54:02 16 8 581 : 883 - 0 0 0 : 0 �1 13AAocs 0.143 nw 4.00 2.55 308 235 939 597 112 79 318 202 F-C 1A-clom 1.270 nw 35.56 45.24 33 0 1162 1478 33 0 1162 1478 �--(� 4A5.2omd 12C-0sw' 0.770 0.091 nw - 21.56 2.55 36.90 1-1:28 41 376 0 376 880 958 1505 . ' 482 0 0 0 0 0 :. 0 0 6 :R ` C 16A-30md 0.032 - 0.90 2.32 1608 1608 1441 3731 294 294 263 682 . F-, ; 22A-tpl 0.989 • -- . 27.69 '.. 0.00 1608 141 .3905 0 294 46 127,4 •' •, . •A 6 c)AED excursion 1638 729 Envelope loss/gain 14626 14645 4042 3743 12 a) Infiltration 2714 765 820 231 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 7 1610 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 17339 17020 4862 4205 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17339 17020 4862 4205 15 Duct loads 34% 52% 5899 8920 34% 52% 1654 2204 FTTotal room load 23239 25941 6516 6408 Air required (cfm) 1160 1160 325 287 Calculations approved byACCA to meet all requirements of Manual J.8th Ed. A -- wrightsoTt' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 1 k Calcs\Documents\WYNNE-MAJESTIC MODEL-1608.rup Calc = MJ8 Front Door faces: N - wrightsoft' RighW@ Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC M. BATH 2 Exposed wall 0 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 7.0 x 9.0 ft 63.0 ft2 1.0 x 61.0 ft 61.0 ft2 Ty Construction number U-value (Btuh/ftk-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 4A5 tom ' 0.143 Oi770 0.T(0 ne ne' . ' ne 4.00 21:56 2156 2.55 36:90 36.90 0 0 .0 0 0 0 0 . U ' 0. 0 '0 0 0. ' 0'. 0 0 0 • .0 0 ' 0. 0 0 0 : 4 V�1 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11 11DO 13A41ocs­. 1Ao1om 1Ac1om 0.399 ;0:143 1.270 1.270 se sw. sw-. sw•. 10.92 4:00 35'56 35:56' 11.31 2.55 42:91 S4.0 0 0 0 0 0 - 0 0 0 0 0 0 ­0_ 0 0 : 0 0 0 - .56 .. 7 0 0 •49 5 .0 0 196 ' 247 0 0 126 298' D -0 V G . 93A-4ocs 1Ac1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 lf/ r--G 4A5-2omd 12C=0sw .0.770 0.091 nw -- 21.56 2.55 36.90 1-.26 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ­0 P. C 16A-30md 0.032 - 0.90 2.32 63 63 56 146 61 61 55 142 tpl ' 0.689 - 27;69 0.00 63 0 •0 ': 0 61, 7. 194; , .- 0 6 c)AED ecursion 01 234 Envelope loss/gain 56 146 692 798 12 a) Infiltration 0 0 125 35 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Qines 6 to 13) 56 146 816 833 Less mdemal load 0 0 0 0 Less transfer 0 0 1 0 0 14 Redistribution Subtotal 0 56 0 146 0 816 0 833 151 Duct loads 34% 52% 19 77 34% 52% 278 437 Total room load 76 223 7 1094 1269 Air required (cfm) 4 10 1 55 57 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. �A - wrigt�tsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 2 ...k Calcs\Documents\WYNNE-MAJESTIC MODEL-1608.rup Calc = MJ8 Front Door faces: N 9 • -- wrightsoft° Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUDRY BEDROOM 2 2 Bposed wall 0 ft 12.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 6.0 ft 36.0 ft2 15.0 x 12.0 ft 180.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (W) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs -4 2om 4A5-2om 0.143 wuo 0.770 ne ne' ne 4.00. 21.56 21.56. 2.55 36.90 36.90 0 - 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0. 0 0 0 0: 0 0 0 yJ I-D 11 13AI 11DO 13A-4ocs` 1Ac1om 0.143 0.390 -.0143 1.270 1.270 se se sw sw> sw 4.00 10.92 4:'00 '35 56. 35:56 2.55 11.31 2.55 •42:91' . , 54.02 0 0 . 0 . 0 0 0 0 ' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .. 96 0 16 0 0 •-. :80 0 8 0 0 •.' 319 0 '581 0 0 203 0 81P -G �1 E-C 13A4ocs 1A-clom 0' 143 1.270 nw nw 4.00 35.56. 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 t 4A5-2omd 12"sw, 0.770. 0.091: .nw - 21.56 2 55 36.90 .1:28 0 0 0 0 0 0 0 0 0. 104.. 0 104 0 ' 265 0 . 133 P C 16A-30md 0.032 - 0.90 2.32 36 36 32 84 180 180 161 418 F:. ': ; :.: ;22A tpl .; , 0.989 - . 27.69 0.06 36 . , p . 0 ,. 0; 180 12 332 .., .. -. r0 6 c)AED exrursion 0 507 Envelope loss/gain 32 84 1659 2143 12 a) Infiltration 0 0 214 60 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 32 84 1873 2204 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 15 6 15 14 Subtotal' 38 98 1878 2218 15 Duct loads 34% 52% 13 51 34% 52%1 639 1162 Total room load 51 149 2517 3381 Air required (cfm) 3 7 126 151 Calculations approved byACCA to meet all requirements of Manual .J.8th Ed. �A - wcightsoft` Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Pg ae 3 ... k CalcslDocumentslWYNNE-MAJESTIC MODEL-1608.rup Calc = MJ8. Front Door faces: N 9 - - wrightsoftRighW@ Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name DINING/GREAT ROOM KITCHEN 2 3 Exposed wall Room height 50.0 ft 9.8 ft heat/cool 12.0 ft 8.0 ft heat/cool 4 Room dimensions 1.0 x 589.0 ft 19.0. x 12.0 ft 5 Room area 689.0 ft2 228.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2--°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cocl Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs 0.143 ne .4.00 . 2.55 294 248 993 .632 96 96 384 244 4A5-2om " . 0.770 -ne 21.56 36:90 21 0 446 764 0 0 0 A 4A526m 0.770 . ne 21,56, . 36.90 25 0 543 . .930 0- 0 0 0 yJ 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 -a 13A46cs ' 0.143 sw .4.00 2:55 :0 0 0 0 ' 0 0 . 0 a 1A�1om ;, 1.270 sw 35.56 42.91 • 0 ' 0 . � 0 .. 0 0 ' '- D . ''o 0: 4Ac1om 1:270 . sw:. 35.58 . - '02 0 0 0 0 .. 0 • .. .0 0 ':-0 Vj! 13A4ocs 0.143 nw 4.00 2.55 196 155 621 395 0 0 0 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 l�-GG 'P ,. ". 4A5-2omd 12C-0sw 0.770 0.091 nw ._ 21.56 2.55 35.90 1.28 41 '0 0 : - 0 880 0- 1505 0 0 - :'104 0 104 0 .• 266 0 133 C 16A30md 0.032 - 0.90 2.32 589 689 528 1366 228 228 204 529 F ^::22A tpl' . 0.989 : - 27.69 0;00 589 50 '1385 . 0 228 12 332 :: '° 0 6 c)AED excursion 168 0 Envelope loss/gain 5396 5760 1186 907 12 a) Infiltration 1092 308 214 60 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 6488 6988 1400 1427 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 15 0 0 14 Subtotal 6494 7002 1400 1427 15 Duct loads 34010 52% 2209 3670 34% 52% 476 748 FTTotal room load 8703 10672 1876 2175 Air required (cfm) 1 1434 477 94 97 Calculations approved byACCA to meet all requirements of Manual J.8th Ed. -I* wriojhtsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 :28:14 4 ..k Calcs\Documents\WYNNE-MAJESTIC MOD EL-1 608. rup Calc = MJ8 Front Door faces: N 9 -t - wrightsoft. Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946"Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS AOL.COM 1 Room name BATH 2 HALL 2 Exposed wall 5.0 ft 0 ft 3 Room height 8.0 ft heaticool 8.0 ft heat/cool 4 5 Room dimensions Room area 10.0 x 5.0 ft 50.0 ft2 5.0 x 5.0 ft 25.0 ft2 Ty Construction number U-value , (Btuh/ft2-'F) Or HTM (Btu 2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs 4A5 tom, 4A52om 0143..ne 0 770 0770. ne he 4.00 21.$6 21;56 2.55. 36.90 36.90 0 0 0 0 0 0 0, 0 0. 0 0 0 0 0 0 0 0. 0 6 0 , 0 0 0. 0; 11 y/ t-D 13A�7oca 11D0 13A�tocs, 1A c1om ' 1A glom, _ 0.143 0.390 0143 `1 270 1.270 se se sw.; sW . sw' 4.00 10.92 4. 0: 35 56_ 35 56... 2.55 11.31 2.55 42.91. 54 02 0 0 40 -'0 0 0 0 40 0 0 0 0 160 0 .: 0 0 0 . 102... ; - 0 0 0 0 0 0 . • 0 0 0 , ..01.., .. ' 0 : 0 0 0 ,0 0 . .0 0 0 ;0 0 0 yJ {L-�� 13A4ocs 1A-c1om 0.143 1.270 nw nw . 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P .. ;'12"sw::.'. 4A5.2omd . ' 0.770 0:091 nw .` = 21.56 2.55. 36.90 C28 0 : " 0 0 " _ .0 0 -0: 0 A 0 0;. 0. 0:', 0 0 0 , :0 C 16A30md 0.032 - 0.90 2.32 50 50 45 116 25 25 22 58 0.989 . ,; 27:69 A. .: • . 0.00 , . .. 50. 5 138 :. 0 .: .. :25..' 0 ,, p _ i = 0. 6 c)AED excursion 0 0 Envelope loss/gain 3431 218 22 58 12 a) Infiltration 891 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 433 243 22 58 Less external load 0 0 0 0 Less .transfer 0 0 0 0 Redistribution 6 15 -22 -58 14 Subtotal 438 257 0 0 15 Duct load. 1 34% 52% 149 135 34% 0 0 Total room load 687 392 _52%1 0 0 Air required (cfm) 29 18 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2017-Apr-11 06:28:14 C�A Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5 k CalcslDocuments\WYNNE-MAJESTIC'MODEL-1608.rup Calc = MJ8 Front Door faces: N - wrightsoft Right-J® Worksheet Job: Entire House Date: ay. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946-Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS aI OL.COM 1 Room name FOYER 2 E)q)osed wall 9.0 ft 3 Room height 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 82.0 ft 82.0 ftz Ty Construction number U-value (Btuh/ft2�-°F) Or HTM (Btuh/ft') Area (ft2) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1344ocs 4A5-2om- ,AA5-2om • 0.143 0:770 O.TCO ne �ne ne 4.00 21.56 21.56. 2.55 36.90 36:90 8 0 : 0 8 '- 0 •. 0 32 0 0 20 0 0 11 VI/ t—D 13A4ocs 11DO 13A46cs : lAc1am `- . 1A�clom . 0.143 0.390 0.143 1.270 1:270 se se 6w . sw., SW; 4.06 10.92 4.00 35.56 35.56., 2.55 11.31 2.55 42.91 54.02 64 23 0 .. 0 0 41 23 :0 0 0 165 248 . 0- 0 0, 105 257 0 0 0 —G -: 1--G T=213A-4ocs 1Aclom 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 4A5-2omd ;92C-0sw. 0.770 0:091 nw .= 21.56 2.55: 36.90 - 1.28 0 168 0 168 0 428 0 ' 216 _ P. C 16A-30md 0.032 0.90 2.32 82 82 73 190 F _ •22A-tpl '. 0:989 27`69 0:00 82 9 249 . 0 6 a)AED excursion 0 Envelope loss/gain 1196 788 12 a) Infiltration b) Room ventilation 160 0 45 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 1357 834 14 15 Less e)demal load Less transfer Redistribution Subtotal Duct toads 34% 52% 0 0 0 1357 462 0 0 0 834 437 Total room load Air required (cfm) 191 1818 1271 57 Calculations approved byACCA to meet all requirements of Manual J.8th Ed. . 410- wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr ll 09:28:14 Page 6 ... k CalcslDocumentslWYNNE-MAJESTIC MODEL-1608.rup Calc = MJ8 Front Door faces: N -- wrightsoft Duct System Summary Jo • Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM r-roject Intormation For. WYNNE DEV. THE MAJESTIC, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.266 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250-/ 0.250 in H2O 0.266 in/100ft 1160 cfm 188 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg . (cfm) Design FR Diam (in) H x W (in) Duct Mat[ Actual . Ln (ft) Ftg.Egv . Ln (ft) Trunk BATH 2 h 587 29 18 0.359 4.0 Ox 0 VIFx 24.3 115.0 st1 BEDROOM 2 c 3381 126 15.1 0.372 7.0 Ox 0 VIFx 19.4 115.0 st1 DINING/GREAT ROOM C 3558 145 159 0.351 7.0 OxO VIFx 27.5 115.0 st1 DINING/GREAT.ROOM-A C 3557 145 159 0.287 7.0 Ox0 VIFx 39.4 135.0 st1 DINING/GREAT ROOM-B C 3557 145 159 0.277 7.0 Ox 0 VIFx 45.2 135.0 st1 FOYER h 1818 91 57 0.515 4.0 Ox0 VIFx 2.0 95.0 KITCHEN C 2175 94 97 0.377 6.0 Ox0 VIFx 17.6 115.0 st1 LAUDRY c 149 3 7 . 0.359 4.0 Ox0 VIFx I 24.3 115.0 st1 M. BATH C 1269 55 57 0.274 4.0 Ox0 VIFx 47.4 135.0 st1 MASTER BEDROOM h 3258 163 143 0.266 7.0 Ox 0 VIFx 52.9 135.0 st1 MASTER BEDROOM -A h 3258 163 143 0.276 7.0 Ox0 VIFx 46.1 135.0 st1 wlc C 223 4 10 0.287 4.0 Ox0 VIFx 39.0 135.0 st1 Supply Trunk Detail Table Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1 Peak AVF 1069 1103 0.266 1032 14.0 0 x 0 VinlFlx wri htsoft° 2017-Apr-1109:28:15 � 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 k CalcslDocuments\wYNNE-MAJESTIC MODEL-1608.Np Calc = MA Front Door faces: N Return Branch Detail Table Name Grille Size (in) . Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloo (fpm) Diam (in) H x W (in) Stud/Joist Opening (in).. Duct Matl Trunk rb1 Ox 0. 1160 1160 0 0 0 0 Ox 0 VIFx .� 2017-Apr-1109:28:15 �, � Wil 9htSOft¢ Right-Sufte® Universal 2017 17.0.14 RSU08101 Page 2 ick ...k CalcslDocuments\WYNNE-MAJESTIC MODEL-1608.rup Calc = MJ8 Front Door faces: N