Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT SUMMARY
DIRECTORY OF PAGES PV-1 PROJECT SUMMARY IRV PV-2 SITE PLAN PV-3 SINGLE -LINE DIAGRAM PV-4 SAFETY LABELS X 0 w QUL MODULE DATASHEET INVERTER DATASHEET MOUNTING SYSTEM DATASHEET MOUNTING SYSTEM ENGINEERING LETTER 1703 CLASS A FIRE CERTIFICATION UL 2703 GROUND AND BONDING CERTIFICATION ANCHOR DATASHEET PROJECT DETAILS PROPERTY OWNER CLARENCE CLARKE PROPERTY ADDRESS 5609 SPANISH RIVER RD, FORT PIERCE, FL 34951 US APN ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) AHJ COUNTY OF ST. LUCIE UTILITY COMPANY FLORIDA POWER & LIGHT CO ELECTRICAL CODE 2014 NEC (NFPA 70) FIRE CODE 2015 NFPA 1 CONTRACTOR INFORMATION COMPANY CORONADO SOLAR LICENSE NUMBER CVC56809 (STATE CERTIFIED SOLAR CONTRACTOR) ADDRESS 3001 CEDORA TER 3001 CEDORA TERRACE, SEBRING, FL 33870 PHONE NUMBER (863) 381-6083 CONTRACTOR SIGNATURE C m :n 0 . 0 t ,� Z CD ST-LUCIE COUNTY PLAN REVIEW BLDG: DATE: ELE DATE: -/ PLUMB: DATE:_ MECH._�_ DATE rn Map data @2018 Google 1 PLOT PV-1 SCALE: NTS r _ 1 � r - o£U7} —Al rlor"sdaRidgee n Park o o u c ---mot 4j; 110'FC1 '$rce� �y t /aQUr7�PC��' 4' r� Y t,f PP tttq fa i 4 4� itPe I� � e� ,t I Treasure Coastz -, ,.�•� r it International u w , Airport anti ie St LucNYt UDTS�EA�L t � Business Park i s e u 44411111vv lllkk4 � � r s. } 7i,r�fi� 9 Pl data @2019 Gca^i=! 2 LOCALE PV-1 SCALE: NTS SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF SOLAR PANELS. THE SOLAR PANELS WILL BE RACKED USING A PREENGINEERED RACKING SYSTEM. THE RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THIS DOCUMENT. SYSTEM DETAILS DESCRIPTION NEW GRID -INTERACTIVE PHOTOVOLTAIC SYSTEM WITH NO BATTERY STORAGE DC RATING OF SYSTEM 5,10OW AC RATING OF SYSTEM 5,000W AC OUTPUT CURRENT 24.OA INVERTER(S) 1 X SMA SB 5.0-1SP-US-40 MODULE HELIENE 72M340 ARRAY WIRING 1) STRING OF 9 (MPPT #1) �1) STRING OF 6 (MPPT #2) INTERCONNECTION DETAILS POINT OF CONNECTION NEW SUPPLY SIDE AC CONNECTION PER NEC SECTION 705.12(A) UTILITY SERVICE 120/240V 1(I) SOLAR DISCONNECT EATON DP221NRB, 2-POLE, 30A, 240VAC SITE DETAILS ASHRAE EXTREME LOW 0°C (32°F) ASHRAE 2% HIGH 33°C (91 OF) CLIMATE DATA SOURCE VERO BEACH MUNICIPAL AIRPORT (KVRB) WIND SPEED 150 MPH (ASCE7-10) RISK CATEGORY II WIND EXPOSURE CATEGORY B GROUND SNOW LOAD OA i P-89756 W CD w Lu 0 0 0 uj �/����uoomo omow Lo LLJ cy) J LL = LL1 Cn U Z W a a U) �.. O � 0 0 LO LL PROJECT REVISIONS Pv_l r: P-89756 tag N� rooado i ustom�Homo� i d W x, Cl) is p s LL'Lo s .... W M " W > J LL O W c= U W Q U) U H Ll.l � Lo l SITE PLAN AERIAL VIEW PV-2 SCALE: 1" = 20. SITE PLAN DOC ID: 89756-111520-1 DATE: 6/1/18 CREATOR: D.M. REVIEWER: REVISIONS PV-2 GENERAL NOTES EQUIPMENT LIKELY TO BE WORKED UPON WHILE 1 ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC SECTION 110.26. 2 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL 3 EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. WHERE DC PV SOURCE OR DC PV OUTPUT CIRCUITS ARE RUN INSIDE THE BUILDING, THEY SHALL BE 4 CONTAINED IN METAL RACEWAYS, TYPE MC METAL - CLAD CABLE, OR METAL ENCLOSURES FROM THE POINT OF PENETRATION INTO THE BUILDING TO THE FIRST READILY ACCESSIBLE DISCONNECTING MEANS, PER NEC SECTION 690.31(G). _ PV MODULE PM1-15 I I 340W AA I I j 91N 1 61N ISTRING ISTRIN I I I I I I r- RAPID SHUTDOWN r im, DEVICES �'--�TRS1-2 I 2 INVERTER I ; ; 115,000w I O4 5 D L� I r�� I I I ; ; j F11-2 L _ _ 30A )30A r-- Sw1 ( I 6 AC SERVICE DISCONNECT GEC AND MAIN DIST. PANEL (200A MSP W/200A MBR) KWHR UTILITY METER 240/120V 10, 3W MODULES RE. QTY. MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OFVOC FUSE RATING�j PM1.15 15 HELIENE 72M340 34OW 303W 9.49A 8.89A 47.0V 38.5V -0.146W'C (-0.31%PC) 15A INVERTERS REF. QTY MAKE AND MODEL AC VOLTAGE I GROUND I MAX OCPD RATING RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INpUiVOLTAGE CEC WEIGHTED EFFICIENCY 11 1 SMASB5.41SP-US-00(240VAC) 240V I UNGROUNDED 50A 5,000W 24.OA 30.OA 600V 97.0% OCPDS REF. I OTY. I RATED CURRENT MAXVOLTAGE F1.2 2 30A 240VAC NOTES ,, UNGROUNDED SYSTEM DC CONDUCTORS SHALL BE COLOR -CODED AS FOLLOWS. DC POSITIVE SHALL BE RED (OR MARKED RED) AND DC NEGATIVE SHALL BE BLACK (OR MARKED BLACK) ® MAX DC VOLTAGE OF ARRAY IS EXPECTED TO BE455.4VAT0'C((O'C-25'C)X-0.146VIC+46.95V)X9=45SAV). RAPID SHUTDOWN DEVICES COMPLIANT WITH REQUIREMENTS AS PER NEC SECTION 690.12. CONTRACTOR ® SHALL INSTALL DEVICE(S) AT LOCATIONS SUCH THAT PV SOURCE CIRCUITS CONDUCTORS MORE THAN 5 FEET INSIDEA BUILDING OR MORE THAN 10 FEET FROM AN ARRAY WILL BE LIMITED TO A MAXIMUM OF 30VAND 24OW WITHIN 10 SECONDS OF RAPID -SHUTDOWN INITIATION. THE SMA INVERTER IS NON -ISOLATED. NEITHER THE NEGATIVE NOR POSITIVE CONDUCTOR IS GROUNDED AND THEREFORE NO DC GEC IS REQUIRED. ® INTEGRATED DC DISCONNECT IS PROVIDED WITH INVERTER. DISCONNECT IS LISTED FOR USE WITH SMA UL 1741 LISTED STRING INVERTERS. ® PVSYSTEM POINT-OFLONNECTIONISONTHE SUPPLY SIDE OFSERVICE DISCONNECT. CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS CURRENT-CARRYINGTEMP, CORR. CONDUIT FILL CONT. MAX CURRENT BASE DERATED TERM. AMP. @ TERM. D TYPICAL CONDUCTOR CONDUIT CONDUCTORS IN OCPD EGC I FACTOR FACTOR CURRENT (125%) AMP. AMP. TEMP. RATING TEMP. RATING CONDUIT 1 1 10 AWG PV WIRE, FREE AIR NIA WA 6 AWG BARE, 0.76 (55'C) 1.0 11.B6A 14.82A 55A 41.8A 75'C 50A COPPER COPPER 2 1 8AWG THWN-2, 0.75'DIH.FLEXIBLE 2 NIA 14AWG THINK 0.96(33-C) 1.0 11.86A 14.82A 55A 52,8A 60'C 40A COPPER STEEL COPPER 3 1 10 AWG PV WIRE, FREE AIR NIA WA 6 AWG BARE, 0.76 (55-C) 1.0 11.86A 14.82A SSA 41.8A 75'C 50A COPPER COPPER 4 1 6AWG THWN-Z 0.75' DIA. FLEXIBLE 2 NIA 14AWG THWN-2, 0.96 (33'C) 1.0 11.86A 14.82A TSA 72A 60'C 55A COPPER STEEL COPPER 5 1 10AWG THWN-2, 1' DL4. LFMC 2 MIA 10 AWG THWN-2, 0.96 (33'C) 1.0 24A 30A 40A 38.4A 60'C 30A COPPER COPPER 6 1 6AWGTHWN-2, 1' DUL LFMC 2 30A X 2 I 10 AWGTHWN-2 0.9fi (33'C) 1.0 24A 30A 75A 72A 75-C 65A COPPER COPPER GROUNDING NOTES ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE 1 REQUIREMENTS OF NEC ARTICLES 250 & 690 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY -IN LUGS. 3 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A 4 VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) 5 SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED 6 ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE GROUNDING AND BONDING CONDUCTORS, IF INSULATED, 7 SHALL BE COLOR CODED GREEN, OR MARKED GREEN_ IF #4AWG OR LARGER SINGLE -LINE DIAGRAM PV-3 SCALE: NTS THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH ALLAPPDCABLE CODES AND REGULATIONS. THE DOCUMENT SHOULD NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION MANUALS. INSTALLER SHALL INSTALLALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTALLATION MANUALS. NOTHING IN THIS DOCUMENT SHOULD BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN MANUFACTURER INSTALLATION MANUALS. P-89756 I I db '�11 /ii o',,, m c0�008d0 otomHomes SINGLE -LINE DIAGRAM PROJECT ID: 89756 DATE: 06/01/18 CREATED BY: D.M. CHECKED BY: REVISIONS PV-3 DC RACEWAYS 2 EACH DISCONNECTING MEANS FOR 1 O PHOTOVOLTAIC EQUIPMENT (RS1, RS2,11) O RS1- RAPID SHUTDOWN DEVICE EL - RIC SHQC' MODEL NOT SPECIFIED TERMINALS. 7EFt LOAD S1©ES MAY I NEC SECTION 690.17(E) (- RAPID SHUTDOWN DEVICE MODEL NOT SPECIFIED O DC DISCONNECT (MPPT CHANNEL B OF 11) (11) MO O O RATED MPP CURRENT: 8.9A RATED MPP VOLTAGE: 231V ( INVERTER SMA SB 5.0-1SP-USMAX SYSTEM VOLTAGE: 550V SM OO O4 O NEC SECTION 690.53 SW1- DISCONNECT O AC SOLAR DISCONNECT (SW1) EATON DP221NR8 O O O O PHOTOVOLTAIC AC DISCONNECT UTILITY METER ONEC SECTION 690.13(B) OEACH DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE. (RS1, RS2,11) NEC SECTION 690.35(F) OSEE NOTE NO.4 (SW1) NEC SECTION 690.56(C) AND IFC 605.11.1 OAC DISCONNECT (SWI) MAXIMUM AC OPERATING CURRENT: 24.OA MAXIMUM AC OPERATING VOLTAGE: 240V NEC SECTION 690.54 ODC DISCONNECT (MPPT CHANNEL A OF 11) (11) RATED MPP CURRENT: 8.9A RATED MPP VOLTAGE: 346V MAX SYSTEM VOLTAGE: 550V NEC SECTION 690.53 OANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (SW1, UTILITY METER) NEC SECTION 705.12(D)(3) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC AND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD 2 HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH NEC SECTION 110.21(B). A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE 3 DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC SECTION. 690.56(B). LABEL(S) WITH MARKING, 'PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN; SHALL BE LOCATED 4 AT POINT -OF -INTERCONNECTION OR AT MAIN SERVICE DISCONNECT THE LABEL SHALL HAVE 3/6° TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND P-89756 ar®nada v�"'� � ustomo omen m W Cn CD w W a_ O Cn W H 0 � Lo W M J LL C= U C zW C/) O � C0 SAFETY LABELS REVISIONS PV-4 B 10 El V WO V I— W Z C7 rroo W E N u cD z 3 0 3 0 za 0 0 0= z= zo ,n z �3 `o Way F 3� 0 o2z z>oz Z�G ♦ V ICERTIFV THAT THE FRAMING OF THIS Lr,.. .-�`!RE I/VILL SAFELY W _ FOR VOLT-200 A' > CONTRACTORRESPONSIBLE TO VERIFYTNEFTTOFTHISARRAYPRIOR\\ NATIOWTHESOLARMODULEARRAY '_-. THE UNIVERSAL PV STRUCTURAL PLAN PER ASCE-7 ACCOMMODATE CALCULATEDW ND UPLIFT AND ATERAL FORCESAND 0 Z DESIGNED lL SHOVM HERE IS BASED ON THE RED DATA PROVIDED BY THE CON =ONTRACTOR SHALL CONTACT ENGMEER IF THE ARRAY RAY NOTFITAS PROJECTED. SATEWTE IMAGERY SHOWN MAY NOTCORRECTLY INDICATE (NO PLAN ON FILE. EACH PERMIT PULLED REQUIRES INDIVIDUAL SEALED PLAN.) EQUIPMENT DEAD LOADS.THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL O FBC 2017 6T" EDITION FLORIDA BUILDING CODE ( ) SS RISK II, EXPOSURE D. W POTENTIAL CURRENT SHADING OF PROPERTY. CONTRACTOR RESPONSIBLE TO VERIFY SU14 EXPOSURE AND SHADING OF INSTALLATION! ON THIS DRAWING AT THE UPPER RIGHT. LU 7 � INSTALLATION PRIOR TO GENERIC PV ROOF MOUNT STRUCTURAL INSTALLATION PLAN. THIS PAPER PLAN IS INTENDED TO PROVIDE THE ESSENTIAL INFORMATION NEEDED BY AHJ (AUTHORITY HAVING JURISDICTION AKA BUILDING DEPARTMENT) AND INSTALLERS. USERS ARE ENCOURAGED TO ACCESS EV (ELECTRONIC VERSION) OF THIS PLAN. ACTIVE HYPERUNKS ON EV PROVIDE EASY ACCESS TO SUPPLEMENTAL INFORMATION. EV ALSO ALLOWS VIEWER TO STUDY THE PLAN DETAILS AT MAGNIFICATION OF VIEWER CHOICE UP TO 6400%. 1. PLAN USERS ARE INVITED TO SUGGEST PLAN IMPROVEMENTS. 2. ENGINEER OF RECORD (EOR) PREFERS EMAIL allen@gezelmanpe.com 3. THIS IS A SINGLE SHEET GENERIC STRUCTURAL PLAN. CONTRACTOR SHALL PROVIDE AM WITH OEM DOCUMENTATION (INSTALLATION INSTRUCTIONS & DATA SHEETS) FOR EQUIPMENT TO BE USED & WHICH ARE HEREBY ADOPTED AS SUPPLEMENTALTO THIS PLAN. 4. SEE OEM DOCUMENTS, NOTES, DRAWINGS, & PHOTO IMAGES HEREON FOR MATERIALS, MEANS, & METHODS INFORMATION. 5. CONTRACTOR SHALL IDENTIFY TO AHJ WHICH DETAILS ARE TO BE USED. 6. THIS PLAN MAY BE USED WITH ANY PV MODULE APPROVED BY AN NRTL (NATIONALLY RECOGNIZED TESTING LABORATORY). AXITEC, CANADIAN SOLAR, SOLAR WORLD ARE AMONG THE MANY SUCH - A MORE COMPLETE LISTING MAY BE VIEWED @ http://www.fsec. u cf.ed u/en/certifi cati o n-testing/pv/PVmod ules/registe red_mod u les/index.ph p 7. THIS PLAN OFFERS MULTIPLE INSTALLATION METHODS. SEE NOTES, OEM DOCUMENTS, DRAWINGS & PHOTOS. a. SHEETING METHOD (SLOPED & LO-SLOPE). b. ADHERED BALLAST METHOD (LO-SLOPE) C. LAG INTO TRUSS/JOIST & SPANNER METHOD. d. STANDING SEAM METAL ROOF. USE CLAMP OF CHOICE; I. ACE. http://www.pmcind.com/aceclamp/ ii. S-S. http://www.s-S.com/clamps/ III. TRA. http://trasnowandsun.com/product-category/solar-mounting/ 8. SOLAR EQUIPMENT ADDS LESS THAN 4-PSF GRAVITY LOAD TO STRUCTURE. 9. THERE SHALL BE A PV MODULE TO RAIL MOUNTING CLAMP AT EVERY MODULE/RAIL CROSSING POINT WITH MINIMUM 4 CLAMPS PER MODULE. ADJOINING MODULES SHALL SHARE GROUNDING MIDCLAMPS. MODULES MAY BE LANDSCAPE OR PORTRAIT AT CONTRACTOR OPTION. CONTRACTOR SHALL FURNISH END CLAMPS OF CHOICE. 10. PV RAIL MOUNTING SYSTEM IS 12-GAGE, POWDER -COATED, STEEL, SELF -GROUNDING, PRE -ASSEMBLED UNITS COLLAPSED FOR SHIPPING. 11. RAILS SHALL BE INSTALLED PERPENDICULAR TO ROOF FRAMING -FLUSH MOUNT. REVERSE PITCH WILL BE PARALLEL. 12. SHEETING METHOD: a. ASSEMBLED UNIT WHICH IS SHIPPED IN A FOLDED TOGETHER (COLLAPSED) FORM RAILS SHALLATTACH TO ROOF THRU L-FEET ATTACHED TO 4-INCH SQUARE X 1/8-INCH THICK GALVANIZED STEEL, SHEETING -ONLY, SELF -FLASHING, ROOF ATTACHMENT PLATES. PLATES SHALL ATTACH TO ROOF SHEETING BY FOUR, 014 X 2-INCH SS SHEET METAL SCREWS. FOR SUPPLIER b. SHEETING -ONLY PLATES INSTALLED AS HEREIN SPECIFIED HAVE UNDERGONE EXTENSIVE TESTING, RESULTS GIVE FOLLOWING MAXIMUM ALLOWABLE UPLIFT PER ROOF ATTACHMENT ON ROOFS BUILT SINCE INTRODUCTION OF 2001 FLORIDA BUILDING ON 1 MARCH 2O02: (POUNDS/ROOF ATTACHMENT) SHINGLE 1200, STANDING SEAM CLAMPS 600, V-CRIMP/PBR ON SHEETED DECK 1200, TILE 900, LEGACY ROOFS (BUILT BEFORE 2001 FBC) 900-POUNDS OR INSITU TEST VALUE. 13. MAX SPANS BETWEEN ROOF ATTACHMENTS IN FLORIDA: a. NORTH OF STATE ROAD (SR) 80; PZS=6, PZ2=4, PZ3=2 b. SOUTH OF SR 80; PZ1=4, PZ2=4, PZ3=2 (NO PZ3 USE IN MIAMI-DADE). C. REVERSE PITCH; 4-FT EVERYWHERE. 14. INSTALLATIONS ON TILE ROOFS SHALL BE POSITIONED SO ATTACHMENTS ARE OVER LONG DIMENSION MIDDLE OF TILE, CONTRACTOR SHALL USE MINIMUM'/. -INCH DIAMETER X 1-1/4-INCH TAPCONS, and CONTRACTOR SHALL INJECT DOW FOAM (TILE BOND OR GREAT STUFF) TO FILL CAVITY UNDER TILE BEFORE INSTALLING TAPCONS. IN HVHZ, USE SS, #14, SCREWS OF SUFFICIENT LENGTH TO EMEND 1-INCH BEYOND BOTTOM FACE OF ROOF SHEETING. FOAM PROVIDES ADEQUATE WATER -PROOFING. 15. CONTRACTOR SHALL PROVIDE ADDITIONAL INFORMATION PER AHJ NEED -WHICH INCLUDES SKETCH SHOWING LOCATIONS: ELECTRIC SERVICE ENTRANCE, MAIN DISTRIBUTION PANEL, PV MODULE ROOF LAYOUT, INVERTER, and PV DISCONNECT, GRID CONNECTION, & OEM DATASHEETS/MANUALS. O1 ENGINEERING NOTES. Sr : Ms - _J 1 ' d f,, J- RAIL APPEARANCE MAY VARY f _ 3/8-16x3/4J HEX HEAD BOLT OEM STANDARD 3/8-16 o OR FOR 7-IN ;- : _ •. -J _.� FLANGE BOLT) J L-FOOT. o FOR " =' GALVANIZED MIN. 4 #14 X 2" PLATE I SMS-SS 1 PER ATTACHMENT I� 4„ r 1 EPDM GASKET �, _�-3/8" SS BOLT 02 SHEETING -ONLY, SELF -FLASHING ROOF ATTACHMENT SCALE: mS GROUNDING PV MODULE GROUNDING MID -CLAMP MID -CLAMP PV RAIL 3/8 - 16 x 3/4 ROOF HEX HEAD BOLT TILE PV RAIL 3/8-16 FLANGE BOLT L-FOOT SS METAL PLATE, SQUARE OR ROUND ROOF SHEETING EXIST.ROOF FOAM EXISTING ASPH.SHINGLE FLORIDA PRODUCT ADHESIVE FRAMING ROOFING APPROVED SEALANT EXISTING FOUR-#4 CRS SCREWS FOUR-#4 CRS SCREWS UNDERLAYMENT BOTTOM 1-IN. BEYOND BOTTOM OF DE KOND OF DECK SHINGLE, TILE, SINGLE PLY 03 SCALE: Nrs FLAT TILE ROOF ATTACHMNET 04 SCALE: an PV RAIL APPEARANCE MAY VARY. MID -CLAMP MID -CLAMP g - 16 x j HEX HEAD BOLT PV RAIL - 16 FLANGE BOLT EXIST PV MODULE PV RAIL ROOF TILE — — — EXIST. METAL DECKING SERRATED L ON ROOF ROOF MOUNT SHEETING ROOF MEMBRANE WATER OPTIONAL PROOFING TILE ROOF FILL CAVITY WITH STANDOFF DOW TILE FOAM EXISTING FRAMING MIN. 4 #14 X 2" SMS -SS WATER PROOFING WITH SONOUISTIC 5/16" CRS. LAG W/ 3" NP-1 OR EQUAL THREAD EMBEDMENT POLYURETHANE CAULK IN BLOCKING, JOIST, OR TRUSS FRAMING -METAL ROOF ATTACHMENT; OS BARRE06 ROOF COVERING COULD BE SHINGLE,TILE, OR SINGLE -PLY. SCALE: N7LTILE ROOF ATTACHMNET S SCALE: NTs Flat Roof Hip Roof (7' < B S 27') Gable Roof (B57°) Gableoo'<0!5 5n PZ1: ROOF INTERIOR PZ3: OUTSIDE CORNERS PZ2: ROOF PERIMETER L & W = PZ2 (MIN. 3' & LEAST OF 40 % EAVE a = PZ2 WIDTH. HEIGHT OR 10% BUILDING LAW. h = EAVE HEIGHT. i, ASCE 7-10 COMPONENT & CLADDING WIND PRESSURE ZONES. TYPICAL SHEETING -ONLY, COMPLETED LOSLOPE SELF -FLASHING, SOLAR ROOF ATTACHMENTVI-OPTIONAL ATTACHMENT WITH OPTIONAL, REDUNDANT WP TARGET REDUNDANT WATERPROOFING. APPEARANCE MAV VARY -DIM/SQRJRND/EfC. DS SELF FLASHING ATTACHMENT PHOTOS SCALE: NR I � O ACE CLAMP TRA MOUNTING CLAMP C1 APPROVED STANDING SEAM ( 10 RAQ COMPOSITION SHINGLE ROOF RACIONG scAIE: NTs PROPER FRAMING ROOF ATTACHMENT PROPERLY INSTALLED FLASHING 11 SCALE: NR 12 SCALE: NTS 1 COMPLETED ADHERED BALLAST SYSTEM I TYPICAL END CLAMP -APPEARANCE MAY VARY 4.5" HDG 3/8' CARRIAGE BOI ADHERED BALLAST SOLAR ATTACHMENT SYSTEM ADHERED BALLAST LAZI L3 TYPICAL GROUNDING IMIDCLAMP.APPEARANCE .d! MAY VARY. �PV RAIL SYSTEM, ORIENTATION OTIONAL 4' x8' x16'CONCRETE BLOCK �DOW TILE BOND OR EQUAL OPTIONAL TARGET 4° X4" PLATE ,,---DECK SCREWS IF NEEDED �TPO ROOF MEMBRANE INSULATION 1 FBC 2017 (6-EDITION FLORIDA BUILDING CODE) ENGINEER ALLEN GEZELMAN 16502 HANNA RD. LUTZ, FLORIDA 33649 PH.813 9D9 1956 Allen@GezelmanPE.com www.GezelmanPE.com PE 59180 MAY 07 2.918 F�LFCTIt 1 PLANSSTwLDIflLA� E D1._.A4 PAPEA PUNS _ BEM SIGNANRF&pgISEDSFAL hung/caelmann,:.com/ref ncc/ FBPF: si—t— sump onipial approsA.PJf DRAFTSMAN: ALPER ICELI alpericeli@mailmsf.edu Z J >^ Q {Z W > U Z � � � ''^^ VJ CONTRACTOR: CORONADO SOLAR 3001 Cedora Terrace Sebring, FI.33870 Tel. 863-381-6083 Fax 863-385-2406 www.CoronadoSolar.net E [A1-USPV_R'jAQ (07.JAN.18) F 9 1 8 1 7 1 6 1 5 1 4 ri 2 1 4 MONO POLY HELIENE 720 GUARANTEED POSITIVE POWER SORTING: [-0 : +4.99 WP] DESIGNED FOR 1500V DC APPLICATIONS MANUFACTURED ACCORDING TO INTERNATIONAL QUALITY SYSTEM STANDARDS: IS09001 H-BLACK INTEGRATION AVAILABLE (ALL -BLACK MODULE) LINEAR PERFORMANCE GUARANTEE ADDED ■Heliene Inc. VA(UFfROMHfIIE Nf$IINEARWARRgIyTY Indusaysratldera 720 emm nm e ,o ,e zo 7s m u w ns so vmnm FCE tt 4,tatek Intatek DATA (STC) _ELECTRICAL Peak Rated Power ry P(W) 350 {� 345 -34D 335 1 Ti s Maximum Power Voltage ? VRmv IV) ( 39.13 — 38.84 38.50 38.21tl �330 j 37.96 > 9 _ , } Y, Maximum Power Currentt iA) 9.01i 8 95 {' 8 E9�T8 83 p n Cucuit Voltage �V (V) ( 47.57 47.2fi 46 95 ` 4fi 64 46.31 Shot Circuit Current ter, Ise (A) 9.65 9 57 9.49 i 9.41i 9.34 ^ ' -11.8 Module Efficiency * i Eff (%) 18.3 i 18.0 j 17.5 17.3 PawerOutputTolerance - � z-- 1-0,+4.991Wp IiL s STC - Standard Test Conditions: Irradiation 100D W/m2 - Air mass AM 1.5 - Cell temperature 25 °C * Calculated using maximum power based on full positive output tolerance [-0 , +4.991 Wp MECHANICAL DATA CERTIFICATIONS UL Listed t� t ULG/ORD-Cl 703-1, UL1703 UL1703 Fire Classification Type i IEC Listed _ i IEC 61215, IEC 6173D i All Heliene modules are certified under the California Energy Commisfon (CEC) Listing Report TEMPERATURE RATINGS _PACKAGING CONFIGURATION Nominal Operating Celia- w_ -� Modules per box 25 pieces Temperature(NOCT) 5C(+2C);k -Modules per 53' trailer:150pieces ! Temperature Coefficient of P_ 0.39%iC �_- TemperatureCoefficientofV¢ -�_ ..w.Y. Temperature Coefficient of j MAXIMUM RATINGS___ Operational Temperature 1 -40*C -+85°C $ Max System Voltage—j „1500V (UL/ IEC) J (€ Max Series Fuse Rating j� 15 A i 1 ( i A WARRANTY ! =; tOYearManufacturer'sWorkmanshipWarran�! � :" 125 Year Linear Power Guarantee (Refer to product warranty page for details) I ! • CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Rj ® © 2016 Heliene Inc. All rights reserved. Specifications included in this datasheet are subject to HELIENE J 0 change without notice. 5-UN f MY Value -Added Improvements Reduced Labor Unmatched Flexibility Trouble -Free Servicing • Superior, integration with SMA's New Installation Assistant with SMA'sproprietary OptTrac7m Two-part enclosure concept MLPE Power+ Solution direct access via smortphone Global Peak technology mitigates allows for simple, expedited • World's first Secure Power Supply'' minimizes time in the field shade with ease servicing now offers up to 2,000 W Integrated disconnect simplifies Multiple independent MPPTs Enhanced AFCI technology reduces • Full grid management capabilities equipment stocking and speeds accommodate hundreds of false tripping while improving ensure a utility -compliant solution installation stringing possibilities sensitivity in real arcs for any market SUNNY BOY 3.0-US / 3.8-US / 5.0-US / 6.0-US / 7.0-US / 7.7-US Reduce costs across your entire residential business model The residential PV market is changing rapidly. Your bottom line matters more than ever -so we've designed a superior residential solution to help you decrease costs at every stage of your business operations. The Sunny Boy 3.0-US/3.8- US/5.0-US/6.0-US/7.0-US/7.7-US join the SMA lineup of field -proven solar technology backed by the world's #1 service team, along with a wealth of improvements. Simple design, improved stocking and ordering, value -driven sales support and streamlined installation are just some of the ways that SMA helps your business operate more efficiently. And, Sunny Boy's superior integration with the innovative Power+ Solution means installers have even more flexibility in addressing their toughest challenges. www.SMA-America.com Sunny Boy 3.0-US Sunny Boy 3:8-US Sunny Boy 5.0-us Technical data 108 v 24D V 208 V 240 V 208 V 240 V Input (DC) Max. usable DC power 3100 W 3100 W 3450 W 4000 W 5150 W 5150 W Max. DC voltage 600 V Rated MPP voltage range 155 - 480 V 195 - 480 V 220 - 480 V MPPT operating *voltage range 100 - 550 V Min. be voltage / start voltage 100 V / 125 V Max. operating input current per MPPT 10 A Max. short circuit current per MPPT 18 A Number of MPPT tracker / string per MPPT hacker 2/1 3/1 output (AC) AC nominal power" 3000 W- 3000 W 3330 W 3800 W 5000 W 5000 W -Max. AC apparent power 3000 VA 3000 VA 3330 VA 9800 VA 5000 VA 5000 VA Nominal voltage / adjustable 208 V / 0 240 V / • 208 V / • 240 V / • 268 V / • 240. V AC voltage range 1 BI- 229 V 211 - 264 V 183 - 229 V , - 211 - 264 V 183 - 229 V 211 - 264 V AC grid frequency 60 Hz / 50 Hz Max. output current 14.5 A 12.5 A 16.0 A 16.0 A 24.0 A ,- 2.4.0 A _ Power foctor (cos p) 1 Output phases / line connections 1/2 Harmonics - <4 Efficiency Max. efficiency 97.2 %, 97.6 % 97.2 % 97.5 % - 97.2 6 97.5 CEC efficiency 96 % 96.5 % . 96.5 % 96.5. % 96.5 % 97"% Protection devices DC disconnect device •- , DC reverse polariy protection - - - Ground fault monitoring / Grid monitoring • AC short circuit protection • Allpole sensitive residual current monitoring unit (RCMU) Arc fault circuit interrupter (AFCI) • Protection class / overvoltoge category I / IV _ - General data Dimensions (W / H / D)-in mm (in) , 535 x 730 x 196 (21.1 x 28.5 x 7.8) Packaging dimensions (W / H / D) in mm (in) 600 x 800 x 300 123.6x 31.5 x 11.8) Weight/ packaging weight 26 kg (57lb) / 30 kg (66 lb) Operating temperature range __ -25°C..+60•C Noise emission (typical) _ - Internal power consumption at night Topology Transformedess _ Cooling concept _ .. ,.Convection - - Features Ethernet ports 2 Secure Power Supply Display (2 x 16 characters) • WLAN .. • Sensor madule/ bdemal WLAN antenna 0/0 Warranty: 10 / 15 / 20years •/0/O _ Certificates and approvals UL 1741, UL 1998, UL.1699B, IEEE1547, FCC Part 15 (Class A $ B), CAN/CSA V22.2 107.1-1 • Stanrd features O Optional features - Not available Data at nominal conditions da NOTE: US inverters ship with gray lids. ` Not functional with Power+ Solution Typedesignation SBICOSP-US40" SB3.8.1SP-USd0 - SB5.04SP-US,40 Accessories q 1, 'Sensor module MD.SMUS40 "mal WIAN ontenao EXTANTa1S40 , � SMA Rooftop Communication Ku 7 ! ROOFCOMMM."Jis r•-------------•j Efficiency curve SUNNY BOY 6.0-1SP-US-40 ---•--•--- 98 -.................................... I� 92- F - -- I i •,�-, t ! ;EE 90--___-- I W i Eb -2zovl 96 i I 89 ...._.- -- Eta (V„-375V) ! i 86. _ .-__ -.. Et.[V„-480V)." i 0.0 0.2 0.4 0.6 0.8 1.0 Output power / Rated power I Technical data Sunny Boy 6.0•US Sunny Boy 7.0-US Sunny Boy 7.7-US _ 208 V 240 V 208 V 240 V 208 V 240 V Input (DC) Max,usable DC power 5400 W 6200 W 6900 W 7200 W 6900 W 7950 W Max. DC Voltage, 600 V Rated MPP Voltage range 220 - 480 V 245 - 480 V 270 - 480 V MPFT operating voltage range 100 - 550 V Min. DC voltage / start voltage 100 V / 125 V Max. operating input current per MPPT 10 A Max. short circuit current per MPPT • 18 A Number 'of MPPT tracker/ string per MPPT tracker 3/1 Output (AC) AC nominal pourer 5200 W 6000 W 6660 W. 7000 W 6660 W 7680 W Max. AC.apparent power 5200 VA 6000 VA 6660 VA 7000 VA 6660 VA 7680 VA Nominal voltage / adjustable- 208 V / • 240 V / • 208 V / !11 240 V / • 208 V / iiii 240 V / • At voltage range 183 - 229 V 211 - 264 V '183 - 229 V 211 - 264 V 183 - 229 V - 211 - 264 V _AC grid frequency 60 Hz / 50 Hz Max. output current 25.0 A , 25.0 A 32.0 A 29.2 A - 32:0 A 32.0 A Power factor (cos 9) 1 Output phases / line connections 1/2 Harmonics < 4 % Efficiency Max. efficiency 97.2 % 97.6 % 97.1 % 97.5 % 97.1 % 97.5 %. CEC efficiency 96.5 % 97,% 96.5 % 97 % 96.5 % 97 % Protection devices DC disconnect device • DC reverse polarity protection Ground fault monitoring / Grid monitoring AC short circuit protection 4110 Allpole sensitive residual current monitoring unit (RCMU) 0 Arc faun circuit Interrupter (AFCI) _ • Protection class / overvoltage category I / IV General data Dimensions (W / H / D) in mm lin)- 535 x 730 x 198.(21.1 x 28.5 x 7.8) Packaging Dimensions (W / H / D) in mm (in) 600 x 800 x 300 (23.6 x 31.5 x 11.8) Weight/ packaging weight - 26 kg (57lb) / 3D kg (46 lb) , Operating temperature range - 25°C.-+60°C Noise emission (typical) 39 dB(A) 45.dBIA) Internal power consumption at night <5 W - , Topology_ Transformerless Cooling concept Convection Fan Features Ethernet ports 2 Secure Power Supply - •' Display (2 x 16.characters) - •. WLAN • Sensor module / External WLAN antenna o / o Warranty: 10 / 15 / 20 years •/c /o Certificates and approvals UL 1741, UL 1998, UL 1699B, IEEE1547, FCC Part 15 (Class A & B), CAN/CSA V22.2 107.1-1 • Standard features O Optional features — Not available Data at nominal conditions NOTE: US inverters ship with gray lids.. ' Not functional with Power+ Solution Type. designation SB&0.I SP-US40 SB7.04 SP-US-40 S87.7-1 SP-USd0 POWER+ SOLUTION The SMA Power+ Solution combines legendary SMA inverter performance and intelligent DC module -level electronics in one cost-effective, comprehensive package. This means that you can achieve maximum solar power production for your customers while also realizing significant installation savings. Unlike conventional microinverter and DC optimizer systems, Power+ is faster to install, provides more flexibility, boasts logistical advantages, and reduces service risk. Visit www.SMA-America.com for more information. F Ld� 8........................................................... ................. Speed the completion of customer proposals and maximize the efficiency of your design team with the Sunny Boy -US series, which provides a new level of flexibility in system design by offering: » Hundreds of stringing configurations and multiple independent MPPTs » SMA's proprietary OptiTrocTm Global Peak shade mitigation technology » Diverse application options including on- and off -grid compatibility fVALUE-DRIVEN SALES �' 1 ENABLEMENT v. F. .................................................................. :; •: . SMA wants to enable your sales team by arming them with an abundance of feature/ benefit support. Show your customers the value of the Sunny Boy -US series by utilizing: » Secure Power Supply, now with 2,000 W of opportunity power in the event of a grid outage, as an increased value -add or upsell opportunity » SMA's 35 year history and status as the #1 global inverter manufacturer instills homeowners with peace of mind and the long-term security they demand from a PV investment SAGA An economical solution for shade mitigation and the challenges of complex roofs w'......................................................................................................................... #1 INVERTER ' IMPROVED• • rr....................................... I ..................... . Ensure that your back office business operations run smoothly and succinctly while mitigating potential errors. The Sunny Boy -US series can help achieve cost savings in these areas by providing: » An integrated DC disconnect that simplifies equipment stocking and allows for a single inverter part number » All communications integrated into the inverter, eliminating the need to order additional equipment ..........................................................................................................................: INSTALLATIONSTREAMLINED • • ............................ Expedite your operations in the field by taking advantage of the new Sunny Boy's installer -friendly feature set including: » Direct access via smartphone and utilization of SMA's Installation Assistant, which minimizes time/labor spent in the field and speeds the path to commissioning » Improved communication —no need to install additional equipment » Integrated DC disconnect that simplifies onsite logistics and eliminates the need to install a separate disconnect unit, speeding overall installation time .......................................................................................................................... . SMA understands the factors that contribute to lifetime PV ownership cost that's why the Sunny Boy -US series was designed for maximum reliability and backstopped by an unmatched service offering. Benefit from: » The new Sunny Boy's two-part enclosure concept that separates the connection unit from the power unit, which allows for simple, expedited servicing » The #1 service team in the PV industry, as recognized by IMS research, with experience servicing an installed base of more than 55 GW ............... ................... ........................ ........................................................ L Srr IRONRIDGE Built for solar's toughest roofs. Datasheet Flush Mount System IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. PE Certified Pre -stamped engineering letters available in most states. Design Assistant Online software makes it simple to create, share, and price projects. 20-Year Warranty Twice the protection offered by competitors. XR Rails O XR10 Rail A low -profile mounting rail for regions with light snow.- • 6' spanning capability • Moderate toad capability • Clear & black anod. finish Clamps & Grounding O UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear & black finish Attachments O FlashFoot2 U71 Flash and mount XR Rails with superior waterproofing. • Twist -on Cap eases install • Wind -driven rain tested • Mill & black finish Resources XR100 Rail XR1000 Rail 1, �•• "" {------------ The ultimate residential solar mounting rail. • 8' spanning capability • Heavy load capability • Clear & black anod. finish Stopper Sleeves Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • 6 different sizes • Clear & black anod. finish Slotted L-Feet A heavyweight mounting rail for commercial projects. • 12' spanning capability • Extreme load capability • Clear anodized finish Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Bonding Hardware Drop -in design for rapid rail Bond and attach XR Rails attachment. to certified attachments. • Secure rail connections • Slot for vertical adjusting • Clear & black anod. finish • T & Square Bolt options • Nut uses 7/16" socket • Assembled & lubricated Datasheet Bonded Splices All rails use internal splices for seamless connections. • Self -drilling screws • Varying versions for rails • Forms secure bonding Microinverter Kits Mount Mls or POs to XR Rails. • Bonds devices to rails • Kit comes assembled • Listed to UL 2703 Flush Standoffs Raise Flush Mount System to various heights. • Works with vent flashing • 4" and 7" lengths • Ships assembled Design Assistant �r pR, NABCEP Certified Training — -� - Go from rough layout to fully a' Earn free continuing education credits, NABCEP engineered system. For free. while learning more about our systems. Go to IronRidge.com/design Go to IronRfdge.corn/training © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.20 1495 Zephyr Avenue /%r I RON RI DGE Hayward, CA 94544 1-800-227-9523 IronRidge.com Attn: Corey Geiger, VP New Markets, IronRidge Inc. Date: December 20th, 2017 Re: Structural Certification and Span Tables for IronRidge Flush Mount System This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof attachment with 3/8" stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core components are shown in Exhibit EX-0015. The IronRidge Flush Mount System is designed and certified to the structural requirements of the following reference standards for the load conditions and configurations tabulated in the attached span tables: ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures (ASCE 7-10) 2015 International Building Code (IBC-2015) Florida Building Code 6th Edition (2017) Building 2015 Aluminum Design Manual (ADM-2015) The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D, roof zones 1, 2 & 3, and roof slopes from 00 to 450. The span tables are applicable provided that the following conditions are met: 1. Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener) 2. The underlying roof pitch, measured between roof surface and horizontal plane, is 450 or less. 3. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet. 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module width shall not exceed 40°. 5. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount installation manual and other applicable standards for general roof construction practice. RON RI DGE 1495 Zephyr Avenue Hayward, CA 94544 1-800-227-9523 IronRidge.com The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. ot�tt4stRlfl+ae�s Sincerely, �.�` C,���C; ';(JA e No 80599 Gang Xuan, PE, LEED AP i ItIc1 111t;6Ngo`` Senior Structural Engineer © 2017 IronRidge, Inc. FL Flush Mount System Certification Letter -1 © 2017 IronRidge, Inc. FL Flush Mount System Certification Letter - 3 ®lr I RON RI DGE Background All roofing products are tested and classified for their ability to resist fire. Recently, these fire resistance standards were expanded to include solar equipment as part of the roof system. Specifically, this requires the modules, mounting hardware and roof covering to be tested together as a system to ensure they achieve the same fire rating as the original roof covering. These new requirements are being adopted throughout the country in 2016. IronRidge Certification IronRidge was the first company to receive a Class A Fire Rating —the highest possible rating —from Intertek Group pic., a Nationally Recognized Testing Laboratory. IronRidge Flush Mount and Tilt Mount Systems were tested on sloped and flat roofs in accordance with the new UL 1703 & UL 2703 test standards.. The testing evaluated the system's ability to resist flame spread, burning material and structural damage to the roof. Refer to the table below to determine the requirements for achieving a Class A Fire Rating on your next project. Class A Fire Rating Test Setup Solar Modules Solar modules are given a Type classification based on their materials and construction. Mounting System Mounting is tested as part of a system that includes type -tested modules and fire -rated roof covering. Roof Covering Roof covering products are given a Fire Class Rating of A, B or C based on their tested fire resistance. Burnin A burning wooden block is placed on module as a fan blows at 12 mph. Flame cannot be seen on underside of roof within 90 minutes. Snread of Flame Test Flame at southern edge of roof is aimed up the roof as a fan blows at 12 mph. The flame -cannot spread 6 feet or more in 10 minutes. Well I Roof Slope Fire Rating* 7FIus�h�Mount Any Slope Type 1, 2, & 3 Class A Tilt Mount ts 6 Degrees Type 1, 2, & 3 Class A 'Class A rated PV systems can be installed on Class A, B, and C roots Frequently Asked Questions What is a "module type"? The new UL1703 standard introduces the concept of a PV module type, based on 4 construction parameters and 2 fire performance parameters. The purpose of this classification is to certify mounting systems without needing to test it with every module. What roofing materials are covered? All fire rated roofing materials are covered within this certification including composition shingle, clay and cement tile, metal, and membrane roofs. What if 1 have a Class C roof, but the jurisdiction now requires Class A or B? Generally, older roofs will typically be "grandfathered in", and will not require re -roofing. However, if 50% or more of the roofing material is replaced for the solar installation the code requirement will be enforced. Where is the new fire rating requirement code listed? 20121BC: 1509.7.2 Fire classification. Rooftop mounted photovoltaic systems shall have the same fire classification as the roof assembly required by Section 1505. Where is a Class A Fire Rating required? The general requirement for roofing systems in the IBC refers to a Class C fire rating. Class A or B is required for areas such as Wildland Urban Interface areas (WUI) and for very high fire severity areas. Many of these areas are found throughout the western United States. California has the most Class A and B roof fire rating requirements, due to wild fire concerns. Are standard mid clamps covered? Mid clamps and end clamps are considered part of the PV "system", and are covered in the certification. More Resources Installation Manuals Visit our website for manuals that include UL 2703 Listing and Fire Rating Classification. Intertek Go to IronRidge.com What attachments and flashings are deemed compatible with Class A? Attachments and their respective flashings are not constituents of the rating at this time. All code -compliant flashing methods are acceptable from a fire rating standpoint. What mounting height is acceptable? UL fire testing was performed with a gap of 5", which is considered worst case in the standard. Therefore, the rating is applicable to any module to roof gap. Am 1 required to install skirting to meet the fire code? No, IronRidge achieved a Class Afire rating without any additional racking components. What determines Fire Classification? Fire Classification refers to a fire -resistance rating system for roof covering materials based on their ability to withstand fire exposure. Class A - effective against severe fire exposure Class B - effective against moderate fire exposure Class C - effective against light fire exposure What if the roof covering is not Class A rated? The IronRidge Class A rating will not diminish the fire rating of the roof, whether Class A, B, or C. What tilts is the tilt mount system fire rated for? The tilt mount system is rated for 1 degrees and up and any roof to module gap, or mounting height. Engineering Certification Letters We offer complete engineering resources and pre -stamped certification letters. Go to IronRidge.com i The Flush Mount System may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "xxx" refers to the module power rating and both black and silver frames are included in the certification. Modules with 35, 40, or 45mm frames and model identifier aaSM66yyPzz-xxx; where "aa" is CH Astronergy Solar or A; "yy" is either 10 or 12; and "zz" is blank or (BL). Frameless modules with model identifier CHSM661 OP(DG)-xxx. Modules with 35 or 40mm frames and model identifier AC-xxxY/aa-ZZ; where "Y" is M or P; "aa" is 125 Axitec or 156; and "ZZ" is 54S, 60S or 72S. Modules with 35 and 40mm frames and model identifier CSbY xxxZ; where "b" can be 1, 3 or 6; "Y" can be K, P, U, V, or X; and "Z" can be M, P, AG, MS, PX , M-SD, P-AG, P-FG or P-SD, MS -AG, MS-FG, or Canadian Solar MS -SD. Frameless modules with model identifier CSbY xxx-FG; where b can be 3 or 6; Y is K, X, or P; and "Z" can be M-FG or P-FG. Modules with 35,, 40, or 50mm frames and model identifier ET Y6ZZxxxAA; where "Y" is P, L, or M; "ZZ" ET Solar is 60 or 72; and AA is WB, WW, BB, WBG, WWG, WRAC, WBCO, WWCO, WWBCO or BBAC. Modules with 35, 40, or 50mm frames and model identifier FXS-xxxYY ZZ; where ")W' is the module Flex power rating; "YY" is BB or BC; and "ZZ" is MAA1 B, MAA1 W, MAB1 W, SAA1 B, SAA1 W, SAC1 B, SACl W, SAD1 W, SBA1B, SBA1 W, SBC1 B, or SBC1 W. Modules with 35 and 40mm frames and and model identifier GCL-a6/YY xxx; where "a" can be M or P; GCL and "YY" can be 60, 72, or 72H. GigaWatt Solar Modules with 40mm frames and model identifier GWxxxYY; where "YY" is either PB or MB. Modules with 40, 45, or 50mm frames and model identifier HSLaaP6-YY 1-xxxZ; where "aa" is either 60 Hanwha Solar or 72; YY is PA or PB; and Z is blank or B. Modules with 32, 35, 40, and 42mm frames and model identifier aaYY ZZ-xxx; where "aa" can be Q. or B.;."YY" can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, or PEAK DUO; and 7z' can be G3, G3.1, G4, G4.1, L-132, L-G2.3, L-G3, L-G3.1, L-G3y, L-G4, L-G4.2, L-G4y, LG4.2/TAA, BFR-G3, BLK-G3, Hanwha Q CELLS BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1/SC, G4.1/TAA, G4.1/ MAX, BFR G4.1/TAA, BFR G4.1/MAX, BLK G4.1/TAA, BLK G4.1/SC, EC-G4.4, G5, BLK-G5, L-G5.2, or L-G5.2/H. Modules with 40mm frames and model identifier YYZZxxx; where "YY" is 36, 60, 72, or 96; and "ZZ" is Heliene M, P, or MBLK. Modules with 35, 40 and 50mm frames and model identifier HIS-YxxxZZ; where "Y" can be M or S; and Hyundai "ZZ!' can be MI, ME MG, SG, RI, RG(BF), RG(BK), TI, or TG. Modules with 40 or 50mm frames and model identifier IT-xxx-YY; where "YY" is blank, HE, or SE, or Itek SE72. Modules with 35, 40 and 45mm frames and model identifier JAyyzz-bb-xxx/aa; where "yy" can be M, P, M6 or P6; "zz" can be blank, (K), (L), (R), (V), (BK), (FA), (TG), (FA)(R), (L)(BK), (L)(TG), (R)(BK), (R) JA Solar (TG), (V)(BK), (BK)(TG), or (L)(BK)(TG); "bb" can be 48, 60, 72, 60SO1 or 72S01; and "aa" can be MP, SI, SC, PR, RE, 313131, 4BB, 4BB/RE, 5BB. Modules with 40mm frames and model identifier JKMYxxxZZ-aa; where "Y" is blank or S; "ZZ" is P, Jinko PP, M; and "aa" is 60, 6013, 60- J4, 6013-J4, 60(Plus), 604, 72, or 724 Frameless modules with model identifier JKMxxxPP-DV. Modules with 46mm frames and model identifier KYxxxZZ-AA; where "Y" is D or U; "ZZ" is blank, GX, or Kyocera SX; and "AA" is LPU, LFU, UPU, LPS, LPB, LFB, LFBS, LFB2, LPB2, 3AC, 3BC, 3FC, 4AC, 4131C, 4FC, 4UC, 5AC, 513C, 5FC, 5UC, 6BC, 6FC, 8131C, 6MCA, or 6MPA. Modules with 35, 40, and 46mm frames and model identifier LGxxxYaZ-bb; where "Y" is A, E, N, Q, S; LG a is 1 or 2; Z' is C, K, T, or W; and bb is A3, A5, B3, G3, G4, or K4. Longi Modules with 40mm frames and model identifier LR6-YY)=M; where "YY" can be 60, 72, or 72HV. Modules with 40mm frames and model identifier MSExxxZZaa; where "ZZ" can be MM, SE, SO or SQ; Mission Solar and as can be 1J, 4J, 4S, 5K, 5T, 6J, 6S, or 6W. 0 2018, IRONRIDGE, INC. VERSION 1.60 FLUSH MOUNT INSTALLATION MANUAL - 9 .,RJ MODULECOMPATIBILITYMODELSMAKE ��- Modules with 46mm frames and model identifier PV MYYxxxZZ; where "YY" is LE or JE; and "ZZ" Mitsubishi is either HD, HD2, or FB. Motech IM and XS series modules with 40, 45, or 50mm frames. Modules with 35mm frames and model identifier D6YxxxZZaa; where "Y" can be M or P;'77 can Neo Solar Power be 83A, B4A, E3A, E4A, H3A, H4A; and "aa' can be blank, (TF), ME or ME (TF). Modules with 35 or 40mm frames and model identifier VBHNxxxYYzz; where "YY" is SA or KA; and Panasonic zz' is 01, 02, 03, 04, 06, 06B, 11, 11 B, 15, 15B, 16, 16B,17, or 18. Modules with 35, 40, or 45mm frames and model identifier PSxxxY ZZIA; where "Y" is M or P; "ZZ" Phono Solar is 20 or 24; and A is F, T or U. Prism Solar Frameless modules with model identifier BiYY xxxBSTC; where "YY" is 48 or 60. Modules with 30, 38 and 45mm frames and model identifier RECxxxYYZZ; where "YY" is M, PE, REC Solar TP, or TP2S; and "ZZ" is blank, BLK, SLV, or 72. Modules with 35, 40 or 50mm frames and model identifier JC)=Y-ZZ; where "Y" is F, M or S; and Renesola ZZ' is Ab, Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, or Db-b. Renogy Modules with 40 or 50mm frames and model identifier RNG-xxxY; where "Y" is D or P. Modules with 40mm frames and model identifier SNxxxY ZZ; where "Y" is M or P; and "=' is 10, or S-Energy 15. Modules with 40mm frames and model identifier SEG-6YY-xxxZZ; where "YY" can be MA, MB, PA, Seraphim Energy Group PB; and "ZZ" can be BB, WB, or WW. Modules with 40 and 50mm frames and model identifier SRP-xxx-6YY; where "YY" can be MA, MB, Seraphim USA PA, PB, QA-XX-XX, and QB-XX-XX. Sharp Modules with 35 or 40mm frames and model identifier NUYYxxx; where "YY" is SA or SC. Modules with 38mm frames and model identifier SYY-Z-xxx; where "YY" is SA or LA; SG or LG; and Silfab "Z" is M, P, or X. Modules with 40mm frames and model identifier PowerXT xxxY-ZZ; where "Y" can be R or C; and Solaria ZZ is BX, BY, PX, PZ, WX or WZ. SolarTech Modules with 42mm frames and model identifier STU-xxxYY; where "YY" can be PERC or HJT. Sunmodule Plus, Protect, XL, Bisun, Bisun XL, maybe followed by mono, poly or duo and/or black SolarWorld or bk; modules with 31, 33 or 46mm frames and model identifier SW-xxx. Thin film modules with 35mm frames and model identifier STO-xxx or STO-xxxA. Thin film Stion frameless modules with model identifier STL-xxx or STL-xxxA. Modules with 35, 40, or 50mm frames and model identifier SE-YxxxZABCDE; where "Y" is B, F, H, SunEdison P, R, or Z; "Z" is 0 or 4; "A" is B, C, D, E, H, I, J, K, L, M, or N, "B" is B or W; "C" is A or C; "D" is 3, 7, 8, or 9; and "E" is 0, 1 or 2. Modules with 35, 38, 40, 46, or 50mm frames and model identifiers OPTxxx-AA-B-YYY Z Suniva or MVXxxx-AA-B-YYY-Z; where "AA" is either 60 or 72; "B" is either 4 or 5; "YYY" is either 100,101,700,1BO, or 11311; and "Z" is blank or B. Modules with model identifierAb-xxx-YY and standard (G3) or InvisiMount (G5) 46mm frame; Sunpower where "A" is either E, P or X; "b" can be 17, 18, 19, 20, 21, or 22; and "YY" can be blank, NE, BLK, COM, C-AC, D-AC, BLK-C-AC, or BLK-D-AC. Sunpreme Frameless modules with model identifier GXB-xxxYY; where "YY" is blank or SL. Suntech Vd, Vem, Wdb, Wde, and Wd series modules with 35, 40, or 50mm frames. Modules with 35, 40 or 46mm frames and model identifier TSM-xxxYYZZ; where "YY" is PA05, PC05, PD05, PA14, PC14, PD14, PE14, or DD05; and "ZZ" is blank, A, A.05, A.08, A.10, A.18, .05, Trina .08, .10, .18, .08D, .18D, 0.82, A.082(II), .002, .00S, 05S, 08S, A(II), A.08(11), A.05(II), A.10(II), or A.18(II). Frameless modules with model identifier TSM-xxxYY; and "YY" is either PEGS, PEG5.07, PEG14, DEG5(II), DEG5.07(11), or DEG14(11). Modules with 35 or 40mm frames and model identifier Wsy-xxxz6; where "y" is either P or T, and Winaico z is either M or P. Yingli Panda, YGE, and YGE-U series modules with 35, 40, or 50 mm frames. W 74 N W g N O CD D Z --- X z --- rT-`- - O? IT! ILL-_ m 0 N � � D m � !�Ozn O 17oOm o m �m Z' m DOT 00 N cKlrmy " A a1 ~ �jmZ _ OD m, A 0b w O O 00O cn D-i = -mD D OZZ m O I o m 7D N (J D H TILZJ{; ID �m D mi rnfrTl !i D i 1- 70 O Om aI Z o CZ i"mid z; n D o0 pZ Z r v C CD N w BASE MOUNT ASSEMBLY SOLD SEPARATELY (QMTR-BM)— o FI �;imVa ; I D i n' 9) D aj mm y7 rS;..o i. o.l 3: iO Orn I TI i 0 c 91 zn <, O "I Z I .. .. 1. __ _.- �.... ........... ..__ .. ..., .. ___. _.._.._ gCLUDED TOWARDS RIDGE O J v0 P N P O 11 EM NO. DESCRIPTION QTY. I CAP SCREW, SERRATED FLANGE, HEX HEAD, I I. 1 5/16"-18 X 1" UNC-2A, GRADE 8, ZINC i 2 POST, 1.25" OD X 4", 6063-T5/6063-T6, MILL 1 3 WASHER, SEALING, 5/16" ID X 1-I/4" OD, 1 EPDM BONDED SS 4 FLASHING, REPLACEMENT TILE, W-TILE, .625" I CONE, ALUMINUM, MILL 5 COLLAR, COUNTER FLASHING, 1-1/4" ID 1 EPDM 6 WASHER, FENDER, 5/16" ID X I" OD, 18-8 SS I 7 WASHER, SPLIT -LOCK, 5/16" ID, 18-8 SS 1 8 CAP SCREW, HEX HEAD, 5/16'-18 X 1" UNC- 1 2A, 18-8 SS AVAILABLE IN MILL, AND BLACK FINISHES Q -ick Mauna PV; TITLE: QMTR-W4: TILE REPLACEMENT, W-TILE, 4" POST UNLESSOTHERWISESPEC IFIE J i -� - DIMENSIONSAREI IINCHE$ SIZE i DRAWN BY: RAD REV TOLERANCES: e I FRACTIONALt 1/8 i /� I DATE: 6/9/2017 3 tlottlflAlr AND coNHDEMIAI TWO PLACE DECIMAL t.19- THEINFOARYANDCONTAINEO WTHLS DRAWINGLS 7HESOIF: PROPE3ifYOF QUICK MOUMPV. ANY REPRODUC110N MPART OR ASA WHOLE WDHOUT THE I DO NOT SCALE DRAWING THREE PLACE DECIMAL 2.094 1SCALE:1:5 IWEIGHT.2.93 iSHEET IOFI wRMENPERML=N OF QUICK MOUNT PV IS PROHMED. COPYRIGHT 02016 QUICK MOUNT PV ____--___.._. :.J