HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTBusiness & Prof
essiona.1 Regulation
�LLST7
Florida Deparnentof BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I searchProduct I
c User
Busines
Professi I ■ USER: PubuApproval
Regulation
Product Approval Menu > duct or Application Search > Application List > Application Detail
OFFICE OF THE FL SECP.ETARY# FL10450-R8
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived 0
Product Manufacturer Tarco Roofing
Address/Phone/Email One Information Way
Suite 225
Little Rock, AR 72202
(254) 913-7750
smohseen@tarcoroofing.com
Authorized Signature Shaik Mohseen
smohseen@tarcoroofing.com
Technical Representative Shaik Mohseen
Address/Phone/Email 2403 Taylors Valley Road
Belton, TX 76513
(254) 913-7750
smohseen@tarcoroofing.com
Quality Assurance Representative Shaik Mohseen
Address/Phone/Email 2403 Taylors Valley Road
Belton, TX 78717
(254) 939-3775 Ext 210
smohseen@tarcoroofing.com
Category
Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/13/2017
Validated By John W. Knezevich, PE
0 Validation Checklist - Hardcopy Received
Certificate of Independence FL10450 R8 COI 2016 01 COI Niemin n Ddf
Referenced Standard and Year (of Standard)
Standard
Year
ASTM D1970
2009
ASTM D226
2006
ASTM D3909
1997
ASTM D4869
2005
ASTM D6164
ASTM D6380
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
FM 4474 2004
FRSA/TRI April 2012 (04-12) 2012
TAS 103 1995
Method 1 Option D
04/18/2016
04/25/2016
06/08/2016
FL #
Model, Number or Name
Description
10450.1
Tarco Roof Underlayments
Roof underlayments for use in prepared roof assemblies
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10450 R8 II 2016 04 FINAL ER TARCO UNDERLAYMENTS FL10450-
R8.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-217.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure herein pertains to
Evaluation Reports
one particular bonded underlayment application
FL10450 R8 AE 2016 04 FINAL ER TARCO UNDERLAYMENTS FL10450-
R8.Ddf
for use beneath adhesive -set tile systems. Refer
to ER Section 5.6.2 for details, and other bonded
Created by Independent Third Party: Yes
underlayment systems. 2.) Refer to ER Section 5
for Limits of Use.
Back Next
Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an WEED employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record..If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
do M@Ell echeck,
securit mr, rocs
QOTRINITYIERD
EVALUATION REPORT
Tarco Roofing
One Information Way, Suite 225
Little Rock, AR 72202
RECEIVED^ `EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
JUN 2 0 2018 353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
T, W e County, Permitting I PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report 10880.07.08-R8
FL10450-R8
Date of Issuance: 07/11/2008
Revision 8: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Tarco Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 04/18/2016. This does not serve as an electronically signed
document. Signed, sealed hardcoples have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
-,I TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Tarco, have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2004
1507.2.3, 1507.3.3, 1507.5.3,
Physical Properties
ASTM D226
2006
1507.7.3, 1507.8.3, 1507.9.3
1507.2.3, 1507.2.8, 1507.4.5.1,
Physical Properties
ASTM D4869
2005
1507.4.5.2, 1507.5.3, 1507.5.3.2,
1507.7.3, 1507.7.3.2, 1507.8.3,
1507.8.3.2, 1507.9.3, 1507.9.3.2
1507.2.4, 1507.2.9.2, 1507.5.3,
Physical Properties
ASTM D1970
2009
1507.7.3
1507.2.9.2
Physical Properties
ASTM D3909
1997
1507.2.9.2, 1507.3.3
Physical Properties
ASTM D6380
2003
1507.3.3
Installation Practice
FRSA/TRI April 2012 (04-12)
2012
1507.11.2
Physical Properties
ASTM D6164
2005
1523.6.5.2.1
Physical Properties
TAS 103
1995
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
ASTM D6164
T6470.08.07-R1
08/30/2007
ERD (TST6049)
FM 4474
T6460.06.07-R1
10/09/2007
ERD (TST6049)
ASTM D1970
T30160.08.09
08/14/2009
ERD (TST6049)
TAS 103
T33190.08.10
08/06/2010
ERD (TST6049)
ASTM D1970
T32530.08.10
08/17/2010
ERD (TST6049)
FM 4474
T37610.07.11
06/29/2011
ERD (TST6049)
ASTM D3909
T40780.04.12
04/06/2012
ERD (TST6049)
ASTM D6380
T40790.04.12
04/06/2012
ERD (TST6049)
TAS 103
T35410.04.12
04/18/2012
ERD (TST6049)
ASTM D1970
T45250.04.13-R2
04/23/2013
ERD (TST6049)
Physical Properties
T43930.09.13-R2
09/11/2013
ERD (TST6049)
Physical Properties
TAR-SC9480.15
07/02/2015
ERD (TST6049)
Wind - FM4470/4474
TAR-SC5670.14
12/03/2015
ERD (TST6049)
Wind - FM4470/4474
TAR-SC8020.14
12/03/2015
PRI(TST5878)
ASTM D1970
BRY-018-02-01
08/11/2003
PRI(TST5878)
ASTM D1970
BRY-017-02-01
08/11/2003
PRI(TST5878)
ASTM D226
TOT-014-02-02
05/18/2004
PRI(TST5878)
ASTM D226
TOT-015-02-02
05/24/2004
PRI(TST5878)
ASTM D6380
TOT-029-02-01
07/05/2005
PRI(TST5878)
ASTM D4869
TOT-009-02-01
09/14/2004
PRI(TST5878)
ASTM D4869
TOT-009-02-02
09/14/2004
PRI(TST5878)
ASTM D226
TOT-041-02-01
05/24/2006
Miami -Dade (CER1592)
FBC HVHZ Certification
12-0420.02
10/03/2013
Tarco Roofing
Adhesive compound
Affidavit
12/15/2015
UL, LLC. (QUA9625)
Quality Assurance
Service Confirmation
Exp. 10/13/2017
Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-118
Certijlcate ojAuthorizatlon #9503 FL10450-R8
Revision 8: 04/18/2016
Page 2 of 10
r
\l TRINITY ERD
4. PRODUCT DESCRIPTION:
4.1 Self -Adhering Underlavments:
LeakBarrier Fast90 Self -adhering Tile Underlayment is an asphalt -saturated organic felt coated on both
sides with asphalt and surfaced on the top side with mineral granules and on the underside with a self -
adhering compound and release film.
LeakBarrier MS300 Ice and Water Armor is a self -adhering, glass mat reinforced, mineral surfaced, SBS
modified roof underlayment.
VoeLeakBarrier PS200HT Ice and Water Armor is a self -adhering, glass mat reinforced, fabric surfaced, SBS
modified roof underlayment.
LeakBarrier PS200mu Ice and Water Armor is a self -adhering,. glass mat reinforced, smooth poly film
surfaced, SBS modified roof underlayment.
LeakBarrier NR500"T is a self -adhering, plastic film surfaced, modified underlayment.
LeakBarrier SS400 Ice and Water Armor is a self -adhering, fiberglass reinforced, smooth surfaced
modified underlayment.
4.2 Mechanically Fastened Underlavments:
Tarco 15 is an ASTM D226 Type I, 15 lb asphalt -saturated organic felt
Tarco 30 is an ASTM D226 Type II, 30 lb asphalt -saturated organic felt
Tarco NO 30 is an ASTM D4869 Type II asphalt -saturated organic felt
LeakBarrier EasyLay is an asphalt -coated polyester fabric roof underlayment.
4.3 Mechanically Fastened and/or Bonded Underlavments:
Fiberglass Mineral Surfaced Roll Roofing is an ASTM D3909, glass -fiber -reinforced, asphalt -coated,
granule surfaced underlayment used as a valley liner.
ASTM Organic Mineral Surface Tile Underlayment is an ASTM D6380, Class M asphalt -saturated organic
roll roofing sheet.
LeakBarrier EasyMop'm SBS is a polyester reinforced, SBS modified bitumen roofing underlayment.
4.4 Mechanically Fastened Base Sheets:
LeakBarrier EasyLay UDL 15 consists of a woven -polymeric scrim with a textured fabric on the top
surface. Within this Evaluation Report, it is used as a base sheet in multi -ply underlayment systems. See
FBC File No. FL16884 use as a stand-alone roof underlayment.
LeakBarrier EasyLay UDL Basic consists of a woven -polymeric scrim with a textured fabric on the top
surface. Within this Evaluation Report, it is used as a base sheet in multi -ply underlayment systems. See
FBC File No. FL16884 use as a stand-alone roof underlayment.
LeakBarrier EasyLay UDL 50 consists of a woven -polymeric scrim with a non -woven fabric on the top
surface and a rubberized polymeric coating on the back surface. Within this Evaluation Report, it is used
as a base sheet in multi -ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof
underlayment.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
Evaluation Report 10880.07.08-118
FL10450-R8
Revision 8: 04/18/2016
Page 3 of 10
,l TRINITY ERD
5.4 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop Tarco underlayments are follows:
TABLE 1: ROOF COVER OPTIONS
Asphalt
wood Shakes
Underlayment
Shingles
Nail -On Tile
Foam -On Tile
Metal
&Shingles
Slate
LeakBarrierFast90
Yes
Yes
Yes
No
Yes
Yes
See
5.LeakBarrier
MS300
Yes
No
No
No
Yes
Yes
ALeakBarrierPS200"T
Yes
Yq§
Yes
Yes
Yes
�See55.2
_
LeakBarrier P5200mu
Yes
No
No
Yes
Yes
Yes
Yes
LeakBarrier NR500HT
Yes
No
No
(No copper or
Yes
Yes
zinc)
LeakBarrierSS400
Yes
No
No
No
Yes
Yes
Yes
Yes
LeakBarrier EasyLay
Yes
(as base sheet in
(as base sheet in
Yes
Yes
Yes
multi -ply system)
multi -ply system)
LeakBarrier EasyLay
Yes
Yes
Yes
Yes
Yes
Yes
UDL 15, UDL Basic or
(See FL36884)
(as base sheet in
(as base sheet in
(See FL36884)
(See FL36884)
(See FL16884)
UDL 50
multi -ply system)
multi -ply system)
Tarco 15
Yes
No
No
Yes
Yes
No
Yes
Yes
Tarco 30
Yes
(as base sheet in
(as base sheet in
Yes
Yes
Yes
multi -ply system)
multi -ply system)
Tarco NO 30
Yes
No
No
Yes
Yes
Yes
(double layer)
(double layer)
(double layer)
(double layer)
Fiberglass Mineral
Yes
Valley Liner per
No
No
No
No
No
Surfaced Roll Roofing
1507.2.9:2 (2)
ASTM Organic Mineral
Yes
Surface Tile
Yes
Yes
No
Yes
Yes
Underlayment
See 55.2
LeakBarrier EasyMop
Yes
Yes
Yes
No
Yes
Yes
SBS
See 5.5.2
5.5.1 Tarco 15, Tarco 30, Tarco NO 30 and EasyLay may be used as a mechanically attached base layer followed
by a LeakBarrier self -adhering top layer or asphalt -applied ASTM Organic Mineral Surface Tile
Underlayment or LeakBarrier EasyMop SBS with allowable roof covers noted above for the respective top
layer underlayments.
5_ S_•� "Foam -On Tile" is limited to use of 3M 2-Component Foam Roof Tile Adhesive AH-160 (FL6332)
applications unless tensile adhesion / long term aging data from an accredited testing laboratory is
provided.
Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-118
Certificate of Authorization #9503 FL10450-RB
Revision 8: 04/18/2016
Page 4 of 10
\I I �NITYIERD
5.6 Allowable Substrates:
5.6.1 LeakBarrier self -adhering direct -bond to deck:
➢ New untreated plywood (unprimed or primed with ASTM D41 primer);
➢ Existing plywood (unprimed or primed with ASTM D41 primer);
➢ New or existing OSB (unprimed or primed with ASTM D41 primer);
➢ Structural concrete (unprimed or primed with ASTM D41 primer).
Note: Tarco does not require priming of new or existing plywood or OSB sheathing. New or existing
plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of LeakBarrier
membranes.
ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMoD SBS Direct -Bond to Deck:
➢ ASTM D41 primed structural concrete.
Note: Refer to 5.6.4 for uplift limitations associated with direct -deck underlayment installations where the
overlying roof cover is foam -on tile roofing.
5.6.2 Bond to Mechanically Attached Base Sheet:
LeakBarrier self -adhered to:
➢ ASTM D226, Type I or II felt;
➢ ASTM D4869 felt;
➢ LeakBarrier EasyLay, LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier
EasyLay UDL 50.
ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS in hot asphalt to:
➢ ASTM D226, Type I or II felt;
➢ ASTM D4601, Type II base sheet.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on the systems, base layer shall be attached
per minimum requirements of FRSA/TRI April 2012 (04-12).
5.6.3 LeakBarrier Self -Adhering Bond to Other Substrate Types:
➢ ASTM D41 primed metal (flashing metal, valley metal, etc.)
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on the systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has
already been applied). Refer to FBC 1609 for determination of design wind loads.
5.6.4.1 Maximum Design Pressure = -75.0 Dsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ
Primer: (Optional) ASTM D41
Base Ply: (Optional) LeakBarrier PS200mu, self -adhered.
Underlayment: LeakBarrier PS200HT, self -adhered.
5.6.4.2 Maximum Design Pressure = -120.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ
Primer: (Optional) ASTM D41
Joint Treatment: Plywood joints are covered with 4-inch wide strips of LeakBarrier PS200"'� or LeakBarrier EasyBase,
rolled into place to create continuous bond
Base Ply: (Optional) LeakBarrier P5200Mu, self -adhered
Underlayment: LeakBarrier P5200HT, self -adhered.
Exterior Research and Design, U.C. Evaluation Report 10880.07.08-RB
Certificate of Authorization #9503 FL10450-RB
Revision 8: 04/18/2016
Page 5 of 10
TRINITY I ERD
5.6.4.3 Maximum Design Pressure = -217.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: (Optional) ASTM D41
Base Ply: (Optional) LeakBarrier PS200mu, self -adhered
Underlayment: LeakBarrier PS200HTI self -adhered.
5.6.4.4 All other direct -deck, adhered Tarco underlayment systems beneath foam -on tile systems carry a
Maximum Design Pressure of -45 psf.
5.6.4.5 Maximum Design Pressure = -45.0 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50 (48" wide
roils); See FBC FL16884.
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 6" o.c. at the 4-inch wide side laps and 8" o.c. at three (3) equally spaced, staggered center rows.
Base Ply: (Optional) LeakBarrier PS20eU, self -adhered
Underlayment: LeakBarrier PS200"T, self -adhered.
5.6.4.6 Maximum Design Pressure = -60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 7" o.c. at the 4-inch wide side laps and 7" o.c. at three (3) equally spaced, staggered center rows.
Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered
Underlayment: LeakBarrier PS200HTI self -adhered.
5.6.4.7 Maximum Design Pressure = -60.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50 (48" wide
rolls); See FBC FL16884.
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 6' o.c. at the 4-inch wide side laps and 6' o.c. at four (4) equally spaced, staggered center rows.
Base Ply: (Optional) LeakBarrier PS200mu, self -adhered
Underlayment: LeakBarrier PS200"T, self -adhered.
5.6.4.8 Maximum Design Pressure = -82.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8" o.c. at the 4-inch wide side laps and 8" o.c. at four (4) equally spaced, staggered center rows.
Base Ply: (Optional) LeakBarrier PS200mu, self -adhered
Underlayment: LeakBarrier PS200"T, self -adhered.
5.6.4.9 Maximum Design Pressure = -120.0 DO:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 4" o.c. at the 4-inch wide side laps and 4" o.c. at four (4) equally spaced, staggered center rows.
Base Ply: (Optional) LeakBarrier PS200mu, self -adhered
Underlayment: LeakBarrier PS200"T, self -adhered.
Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-RS
Certif sate of Authorization #9503 F1.10450-118
Revision 8: 04/18/2016
Page 6 of 10
\I TRINITY I ERD
5.6.4.10 For mechanically attached base sheet in a multi -ply system, the maximum design pressure for the selected
assembly shall, at a minimum, meet or exceed the Zone 1 design pressure determined in accordance with
FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609. Zones 2 and 3 shall employ an attachment
density designed by a qualified design professional to resist the elevated pressure criteria. Commonly
used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD1. Assemblies above marked with an
asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements.
5.7 Exposure Limitations:
LeakBarrier EasyLay, FAST 90, ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier EasyMop
SBS shall not be left exposed for longer than 180-days after installation.
LeakBarrier PS200"T shall not be left exposed for longer than 120-days after installation.
LeakBarrier MS300, NR500"T, PS200'u or SS400 shall not be left exposed for longer than 30-days after
installation.
Tarco 15, Tarco 30 and Tarco NO 30 shall be covered as soon as possible after installation; exposure for
more than 24 hours after installation could adversely affect performance.
6. INSTALLATION:
6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and primed the substrate (if applicable).
6.3 LeakBarrier® Fast90® Self -Adhering Tile Underlavment:
6.3.1 EasyLay shall be installed in compliance with the requirements for 90# felt underlayment (except the
product is self -adhered) in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile Applications:
Cut the Fast90 roll into 12' to 16' sections for workability and allow to relax prior to application.
Chalk a plumb line 36" from all outside perimeters; then chalk plumb lines 32" apart, upslope to the ridge
line.
Membrane Application:
➢ Place a full width piece of Fast90 on the prepared substrate, parallel to the eave edge of the roof, with
the selvedge edge positioned upslope and in -line with the 15L chalk line.
➢ Fold back half the sheet and remove the exposed release film, taking care not to displace the
membrane
➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles
and ridges, and repeat for the other half of the sheet.
➢ Remove selvage release film, if present, and install capped or tin tagged nails 6" o.c. in the center of the
selvedge edge.
➢ install the subsequent sheets in the same manner, with upslope selvedge edges in -line with chalk lines,
with 4" side laps and 8" end laps.
➢ Seal all 8" end laps 1/16" thick application of asphalt plastic cement and stagger all end laps minimum
36".
➢ Roll the entire surface with a weighted roller, paying particular attention to side laps, end laps and eave
/ rake areas to ensure a complete bond.
6.3.4 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Wait a minimum of 24 hours prior to loading roof tiles.
Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-R8
Certificate of Authorization #9503 FL10450-R8
Revision 8: 04/18/2016
Page 7 of 10
. N �
V I �Nlli ERD
All tiles shall be staged four tiles perpendicular to slope, six tiles on top, parallel to slope; not to exceed 10
tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to be left in a
staged condition for more than 30 days, tiles shall be staged two tiles perpendicular to slope, four tiles on
top, parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for
lugged tiles.
At roof pitch in excess of those noted above, the tiles shall be staged behind a nominal 1 x 2 horizontal
batten.
6.4 LeakBarrier® MS300 PS200"T PS200Mu NRS00"T or SS400 Ice and Water Armor:
6.4.1 MS 300, PS200"TPS200MU, NR500"T or SS400 shall be installed in compliance with the requirements for
ASTM D1970 und,erlayment in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.4.2 Non -Tile Applications:
Cut MS 300, PS200 "T, PS200MU, NR500"T or SS400 to manageable sections and allow to relax prior to
application.
Membrane Application:
➢ Place a full width piece on the prepared substrate, aligned parallel to the eave edge and extend
approximately 3/8" over the eave and rake with the selvedge edge positioned upslope.
➢ Fold back the upslope half of the sheet and remove the exposed release film, taking care not to displace
the membrane
➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles
and ridges
➢ Apply a 1/16" thick layer of asphalt plastic cement over the eave and rake metal, extending 2" to 3"
onto the deck surface.
➢ Fold back the downslope half of the sheet, remove the release film and roll the membrane onto the
substrate from the centerline out.
➢ Seal all 6" end laps with a 1/16" thick application of asphalt plastic cement and stagger all end laps
minimum 36".
➢ Remove selvage release film, if present, and install second and subsequent courses in a similar manner.
➢ Install capped or tin -tagged nails 6" o.c. along the centerline of the laps.
➢ At all T-joints, where an end -lap and the next overlapping course intersect, apply a bead of roofing laps
cement before the overlapping course is laid.
➢ Roll the entire surface with a weighted roller, paying particular attention to side laps, end laps and eave
/ rake areas to ensure a complete bond.
6.4.3 Tile Applications (PS200"T only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Wait a minimum of 24 hours prior to loading roof tiles.
All tiles shall be staged four tiles perpendicular to slope, six tiles on top, parallel to slope; not to exceed 10
tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to be left in a
staged condition for more than 30 days, tiles shall be staged two tiles perpendicular to slope, four tiles on
top, parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for
lugged tiles.
At roof pitch in excess of those noted above, the tiles shall be staged behind a nominal 1 x 2 horizontal
batten.
Exterior Research and Design, LLC. Evaluation Report 10880.07.08-118
Certificate of Authorization #9503 FL10450-R8
Revision 8: 04/18/2016
Page 8 of 10
TRINITY J ERD
6.4.4 Multi -Ply Underlayment Systems:
LeakBarrier® SS400 Ice and Water Armor followed by LeakBarrier® SS400 Ice and Water Armor (direct -to -
deck per 5.6.1 or over mechanically attached base sheet per 5.6.2) is allowable for use under mechanically
attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not
a requirement, but is allowable if a multi -ply underlayment system is desired.
6.5 Tarco 15 and 30:
6.5.1 Tarco 15 and 30 shall be installed in compliance with the requirements for ASTM D226, Type I and II
underlayments, respectively, in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.5.2 Non -Tile Applications:
Reference is made to the current edition of the NRCA Steep -slope Roofing Manual.
6.5.3 Tile Applications, base laver in multi -ply system (Tarco 30 only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein.
6.6 Tarco NO 30:
6.6.1 Tarco NO 30 shall be installed in compliance with the requirements for ASTM D4869, Type II underlayment
in FBC Sections 1507 for the type of prepared roof covering to be installed; 1507.4.5.2 (1), 1507.5.3.2 (1),
1507.7.3.2 (1), 1507.8.3.2 (1) or 1507.9.3.2 (1).
6.7 LeakBarrier EasyLay:
6.7.1 EasyLay shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in
FBC Sections 1507 for the type of prepared roof covering to be installed.
6.7.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application.
6.7.3 Non -Tile Applications:
Place a full width section of EasyLay, parallel to the eave edge of the roof and unroll 2 to 3 feet with the lay
lines facing up, and position to the edge of the eave and rake. Install a few fasteners at the top, near the
rake, and roll out the sheet to a manageable length. Pull, straighten and align the sheet so that any
wrinkles are eliminated and the sheet is even with the eave edge. Fasten with 3/8" headed roofing nails or
1" capped (plastic or metal) nails, driven by hand or pneumatically, spaced 6" o.c. at all laps in the center
of the seam area, and two staggered rows fastened 12" o.c. in the field of the sheet. Install nails such that
the head of the nail is flush with the surface, without cutting into the surface. Fasten from the top to
avoid walking or kneeling on unsecured sheet. Continue to the end of the substrate and fasten down.
Align the next roll over the preceding sheet so as to form a minimum 4", water -shedding lap, and install
per instructions above. Apply subsequent sheets in the same manner, with minimum 4" water -shedding
laps and minimum 8" end -laps, which are staggered minimum 36" fro the preceding course.
For double layer applications, follow the instructions noted above, but using a minimum 19", water -
shedding side lap.
Allow for minimum 6" up the vertical transitions and minimum 6" over hips and ridges.
At valleys, first install a vertical length of EasyLay down the center of the valley, then start at the low point
and work to the high point, rolling the membrane from the center outward in each direction, ensuring no
wrinkles or tears. Covered with valley -metal or other valley lining material in accordance with NRCA
recommendations.
Apply a thin coat of asphalt plastic cement to waterproof areas where any cuts or tears have occurred.
Seams or joints that require adhesive or sealant can be treated with high quality plastic cement (asbestos
free).
Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-R8
Certificate of Authorization #9503 FL10450-R8
Revision 8: 04/18/2016
Page 9 of 10
r .
7
Y
TRINITY I ERD
6.7.4 Tile Applications, base laver in multi -ply system:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein.
6.8 ASTM Organic Mineral Surface Tile Underlavment:
6.8.1 Shall be installed in compliance with the requirements for ASTM D6380, Class M sheets in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.8.2 Non -Tile Applications:
Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA
recommendations for installing shingle underlayments and flashings.
6.8.3 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. Tile shall be
loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
6.9 LeakBarrier'"° EasyMop SBS:
6.9.1 Shall be installed in compliance with current Tarco published installation requirements, subject to the
limitations herein.
6.9.2 Non -Tile Applications:
For mechanically attached applications: Secure LeakBarrier EasyMop SBS using 3/8-inch headed roofing
nails or 1-inch diameter cap -nails spaced 9-inch o.c. within the 4-inch wide side laps and 12-inch o.c. in two
(2) equally spaced, staggered center rows in the center of the sheet. End -laps shall be minimum 6-inch
wide, and offset end -laps minimum 3-feet from course to course. Seal end laps in accordance with Tarco
requirements.
For bonded applications: Fully adhere LeakBarrier EasyMop SBS in hot -asphalt to the substrates noted in
Section 5.5. Side laps shall be minimum 4-inch and end -laps minimum 6-inch wide, and offset end -laps
minimum 3-feet from course to course. Side and end -laps shall be fully adhered in a complete mopping of
hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. Consult Tarco
instructions regarding back -nailing requirements.
6.9.3 Tile Applications:
Refer to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. Tile shall be loaded and
staged in a manner that prevents tile slippage and/or damage to the underlayment.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements
9. QUALITY ASSURANCE ENTITY:
UL, LLC. — QUA9625; (847) 664-3281
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
Evaluation Report 10880.07.08-118
FL10450-RB
Revision 8: 04/18/2016
Page 10 of 10